989 resultados para Free Software Movement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Architectural (bad) smells are design decisions found in software architectures that degrade the ability of systems to evolve. This paper presents an approach to verify that a software architecture is smellfree using the Archery architectural description language. The language provides a core for modelling software architectures and an extension for specifying constraints. The approach consists in precisely specifying architectural smells as constraints, and then verifying that software architectures do not satisfy any of them. The constraint language is based on a propositional modal logic with recursion that includes: a converse operator for relations among architectural concepts, graded modalities for describing the cardinality in such relations, and nominals referencing architectural elements. Four architectural smells illustrate the approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The goal of the present study was to develop a strategy for three-dimensional (3D) volume acquisition along the major axes of the coronary arteries. BACKGROUND: For high-resolution 3D free-breathing coronary magnetic resonance angiography (MRA), coverage of the coronary artery tree may be limited due to excessive measurement times associated with large volume acquisitions. Planning the 3D volume along the major axis of the coronary vessels may help to overcome such limitations. METHODS: Fifteen healthy adult volunteers and seven patients with X-ray angiographically confirmed coronary artery disease underwent free-breathing navigator-gated and corrected 3D coronary MRA. For an accurate volume targeting of the high resolution scans, a three-point planscan software tool was applied. RESULTS: The average length of contiguously visualized left main and left anterior descending coronary artery was 81.8 +/- 13.9 mm in the healthy volunteers and 76.2 +/- 16.5 mm in the patients (p = NS). For the right coronary artery, a total length of 111.7 +/- 27.7 mm was found in the healthy volunteers and 79.3 +/- 4.6 mm in the patients (p = NS). Comparing coronary MRA and X-ray angiography, a good agreement of anatomy and pathology was found in the patients. CONCLUSIONS: Double-oblique submillimeter free-breathing coronary MRA allows depiction of extensive parts of the native coronary arteries. The results obtained in patients suggest that the method has the potential to be applied in broader prospective multicenter studies where coronary MRA is compared with X-ray angiography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El present projecte se centrarà en l'aplicació dels SIG a la prevenció dels incendis forestals a Catalunya. En concret en la localització de zones òptimes per a la instal lació de tallafocs, mitjançant la utilització dels programes lliures gvSIG i Sextant, a més de la base de dades (BDD) espacial PostgreeSQL / PostGIS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hazard mapping in mountainous areas at the regional scale has greatly changed since the 1990s thanks to improved digital elevation models (DEM). It is now possible to model slope mass movement and floods with a high level of detail in order to improve geomorphologic mapping. We present examples of regional multi-hazard susceptibility mapping through two Swiss case studies, including landslides, rockfall, debris flows, snow avalanches and floods, in addition to several original methods and software tools. The aim of these recent developments is to take advantage of the availability of high resolution DEM (HRDEM) for better mass movement modeling. Our results indicate a good correspondence between inventories of hazardous zones based on historical events and model predictions. This paper demonstrates that by adapting tools and methods issued from modern technologies, it is possible to obtain reliable documents for land planning purposes over large areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors developed a free-breathing black-blood coronary magnetic resonance (MR) angiographic technique with a potential for exclusive visualization of the coronary blood pool. Results with the MR angiographic technique were evaluated in eight healthy subjects and four patients with coronary disease identified at conventional angiography. This MR angiographic technique accurately depicted luminal disease in the patients and permitted visualization of extensive continuous segments of the native coronary tree in both the healthy subjects and the patients. Black-blood coronary MR angiography provides an alternative source of contrast enhancement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El departament d’electrònica i telecomunicacions de la Universitat de Vic ha dissenyat un conjunt de plaques entrenadores amb finalitat educativa. Perquè els alumnes puguin utilitzar aquestes plaques com a eina d’estudi, és necessari disposar d’un sistema de gravació econòmic i còmode. La major part dels programadors, en aquest cas, no compleixen amb aquests requeriments. L’objectiu d’aquest projecte és dissenyar un sistema de programació que utilitzi la comunicació sèrie i que no requereixi d'un hardware ni software específics. D’aquesta manera, obtenim una placa autònoma i un programador gratuït, de muntatge ràpid i simple d’utilitzar. El sistema de gravació dissenyat s’ha dividit en tres blocs. Per una banda, un programa que anomenem “programador” encarregat de transferir codi de programa des de l’ordinador al microcontrolador de la placa entrenadora. Per altra banda, un programa anomenat “bootloader”, situat al microcontrolador, permet rebre aquest codi de programa i emmagatzemar-lo a les direccions de memòria de programa corresponents. Com a tercer bloc, s’implementa un protocol de comunicació i un sistema de control d’errors per tal d’assegurar una correcta comunicació entre el “programador” i el “bootloader”. Els objectius d’aquest projecte s’han complert i per les proves realitzades, el sistema de programació ha funcionat correctament.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fractal mathematics has been used to characterize water and solute transport in porous media and also to characterize and simulate porous media properties. The objective of this study was to evaluate the correlation between the soil infiltration parameters sorptivity (S) and time exponent (n) and the parameters dimension (D) and the Hurst exponent (H). For this purpose, ten horizontal columns with pure (either clay or loam) and heterogeneous porous media (clay and loam distributed in layers in the column) were simulated following the distribution of a deterministic Cantor Bar with fractal dimension H" 0.63. Horizontal water infiltration experiments were then simulated using Hydrus 2D software. The sorptivity (S) and time exponent (n) parameters of the Philip equation were estimated for each simulation, using the nonlinear regression procedure of the statistical software package SAS®. Sorptivity increased in the columns with the loam content, which was attributed to the relation of S with the capillary radius. The time exponent estimated by nonlinear regression was found to be less than the traditional value of 0.5. The fractal dimension estimated from the Hurst exponent was 17.5 % lower than the fractal dimension of the Cantor Bar used to generate the columns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Amplified Fragment Length Polymorphisms (AFLPs) are a cheap and efficient protocol for generating large sets of genetic markers. This technique has become increasingly used during the last decade in various fields of biology, including population genomics, phylogeography, and genome mapping. Here, we present RawGeno, an R library dedicated to the automated scoring of AFLPs (i.e., the coding of electropherogram signals into ready-to-use datasets). Our program includes a complete suite of tools for binning, editing, visualizing, and exporting results obtained from AFLP experiments. RawGeno can either be used with command lines and program analysis routines or through a user-friendly graphical user interface. We describe the whole RawGeno pipeline along with recommendations for (a) setting the analysis of electropherograms in combination with PeakScanner, a program freely distributed by Applied Biosystems; (b) performing quality checks; (c) defining bins and proceeding to scoring; (d) filtering nonoptimal bins; and (e) exporting results in different formats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Peer-reviewed

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Softcatalà is a non-profit associationcreated more than 10 years ago to fightthe marginalisation of the Catalan languagein information and communicationtechnologies. It has led the localisationof many applications and thecreation of a website which allows itsusers to translate texts between Spanishand Catalan using an external closed-sourcetranslation engine. Recently,the closed-source translation back-endhas been replaced by a free/open-sourcesolution completely managed by Softcatalà: the Apertium machine translationplatform and the ScaleMT web serviceframework. Thanks to the opennessof the new solution, it is possibleto take advantage of the huge amount ofusers of the Softcatalà translation serviceto improve it, using a series ofmethods presented in this paper. In addition,a study of the translations requestedby the users has been carriedout, and it shows that the translationback-end change has not affected theusage patterns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tämän diplomityön tavoitteena on muodostaa sähköinen liiketoimintamalli kansainvälisen ohjelmistoyrityksen tarpeisiin. Ohjelmiston uusi ominaisuus antaa kolmansille osapuolille mahdollisuuden määritellä itse rakennusmallintamisessa tarvittavia komponentteja, mikä luo mahdollisuuden uuteen liiketoimintaan. Liiketoimintamallien teoria ja asiantuntijoiden haastattelut tulevat osoittamaan, että paras ratkaisu tässä tapauksessa on portaali, joka rakentuu komponenttimarkkinoista, e-kaupasta ja virtuaaliyhteisöstä. Komponenttimarkkinat on jaettu vapaaseen vaihdantaan ja sertifioitujen kehittäjien kaupankäyntiin. Tämä tarjoaa mahdollisuuksia kehittäjille valita sitoutuneisuutensa taso, samoin kuin motivoi heitä osallistumaan. E-kauppa on suunniteltu sovelluksille ja monimutkaisemmille komponenteille. Virtuaaliyhteisön kautta käyttäjät voivat keskustella mielipiteistään ja saada tukea ohjelmiston käyttämiseen sekä komponenttien kehittämiseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Desarrollo de una aplicación basada en la localización y creación de rutas para personas discapacitadas, mayores, con movilidad reducida, con Alzheimer o demencia senil y personas que no puedan comunicarse verbalmente. La función de la aplicación es saber siempre su ubicación y, en caso de sufrir alguna crisis, llamar a sus cuidadores o familiares.