976 resultados para Fire protection districts


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyphosphate esters containing ferrocene structures were synthesized from 1,1′-bis (p-hydroxyphenylamido) ferrocene and 1,1′-bis (p-hydroxyphenoxycarbonyl) ferrocene with aryl phosphorodichloridates by interfacial polycondensation using a phase transfer catalyst. The polymers were characterized by infrared, 1H-, 13C-, and 31-NMR spectroscopy. The molecular weights were determined by end group analysis using 31P-NMR spectral data. The thermal stability and fire retardancy were respectively determined by thermogravimetry and limiting oxygen index (LOI) measurements. The polyamide-phosphate esters showed better thermal stability and higher LOI values than the polyester-phosphate esters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire is an important driver of the boreal forest ecosystem, and a useful tool for the restoration of degraded forests. However, we lack knowledge on the ecological processes initiated by prescribed fires, and whether they bring about the desired restoration effects. The purpose of this study was to investigate the impacts of low-intensity experimental prescribed fires on four ecological processes in young commercial Scots pine (Pinus sylvestris) stands eight years after the burning. The processes of interest were tree mortality, dead wood creation, regeneration and fire scar formation. These were inventoried in twelve study plots, which were 30 m x 30 m in size. The plots belonged to two different stand age classes: 30-35 years or 45 years old at the time of burning. The study was partly a follow-up of study plots researched by Sidoroff et al. (2007) one year after burning in 2003. Tree mortality increased from 183 stems ha-1 in 2003 to 259 stems ha-1 in 2010, corresponding to 15 % and 21 % of stem number respectively. Most mortality was experienced in the stands of the younger age class, in smaller diameter classes and among species other than Scots pine. By 2010, the average mortality of Scots pine per plot was 18%, but varied greatly ranging from 0% to 63% of stem number. Delayed mortality, i.e. mortality that occurred between 2 and 8 years after fire, seemed to become more important with increasing diameter. The input of dead wood also varied greatly between plots, from none to 72 m3 ha-1, averaging at 12 m3 ha-1. The amount of fire scarred trees per plot ranged from none to 20 %. Four out of twelve plots (43 %) did not have any fire scars. Scars were on average small: 95% of scars were less than 4 cm in width, and 75% less than 40 cm in length. Owing to the light nature of the fire, the remaining overstorey and thick organic layer, regeneration was poor overall. The abundance of pine and other seedlings indicated a viable seed source existed, but the seedlings failed to establish under dense canopy. The number of saplings ranged from 0 to 12 333 stems ha-1. The results of this study indicate that a low intensity fire does not necessarily initiate the ecological processes of tree mortality, dead wood creation and regeneration in the desired scale. Fire scars, which form the basis of fire dating in fire history studies, did not form in all cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kävelykadut ovat tunnustettu tapa elävöittää keskusta-alueiden kauppaa. Aluksi moni kauppias epäilee kävelykadun tuomia muutoksia, mutta kokemus osoittaa, että kävelykadut ovat olleet menestyksekkäitä ja nostavat siellä olevien yritysten myyntiä. Jotkut yritykset eivät kuitenkin hyödy kävelykaduista, kun taas toiset hyötyvät paljon kun katu muuttuu kävelykaduksi. Tämä pro gradu -tutkielma tutkii kävelykatujen kaupallista rakennetta, jotta saataisiin selville minkätyyppiset yritykset löytyvät kävelykadulta. Tuloksia verrataan sen kaupallisen keskusvyöhykkeen kaupalliseen rakenteeseen missä kävelykatu sijaitsee. Näin saadaan selville erot kaupallisessa rakenteessa. Pro gradu tutkii myös miten tavallisia ketjuyritykset ovat kävelykaduilla ja kaupallisissa keskusvyöhykkeissä. Tutkimusaineisto koottiin kaupallisen inventoinnin avulla, joka suoritettiin kolmessa suomalaisessa kaupungissa: Tammisaaressa, Keravalla ja Porissa. Saatu aineisto luokiteltiin ja tulokset piirrettiin kartalle. Perustilastollisia menetelmiä käytettiin tulosten analysoimisessa. Tulokset eriteltiin kävelykadun, kauppakeskusten ja muiden paikkojen osalta ja luokiteltiin yleisluokkiin vähittäiskauppa, ravintola ja muu palvelu. Tulokset näyttävät, että on olemassa selkeitä eroja kun vertaa kävelykatuja ja kaupallisia keskusvyöhykkeitä. Kävelykaduilla on paljon enemmän vähittäiskauppoja, etenkin muotikauppoja, kuin muilla kaduilla. Kauppakeskuksilla on samantapainen kaupallinen rakenne kuin kävelykaduilla kun taas muilla kaduilla esiintyy vähemmän vähittäiskauppoja ja enemmän palveluyrityksiä. Ravintolat ovat melkein yhtä tavallisia koko kaupallisessa keskusvyöhykkeessä. Ketjuyritysten osalta tulokset ovat epäselviä. On olemassa osviittaa siitä, että ne ovat tavallisempia kävelykaduilla, etenkin suurissa kaupungeissa. Saatua tulosta ei ole kuitenkin tarpeeksi, jotta varmaa tietoa olisi saatu. Viimeisten 10–15 vuoden ajan Suomen kävelykadut ovat muuttuneet enemmän ravintolavaltaisiksi muiden palveluiden kustannuksella. Vähittäiskauppojen määrä on pysynyt vakaana. Suomalaiset kävelykadut eroavat kaupalliselta rakenteeltaan pohjoismaisista kävelykaduista, joilla on enemmän vähittäiskauppoja ja vähemmän palveluyrityksiä. Tapauskohtaisissa tuloksissa esiintyy paljon eroavaisuuksia. Paikalliset tekijät ovat usein voimakkaampia kuin yleiset teoriat kauppojen sijainnista kävelykaduilla. Yleisesti ottaen tulokset tukevat teoreettista viitekehystä. Tulokset antavat tarkempaa tietoa kävelykatujen ja kaupallisten keskusvyöhykkeiden kaupallisesta rakenteesta ja siitä, mitkä tekijät tähän vaikuttaa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutral point clamped (NPC), three level converters with insulated gate bipolar transistor devices are very popular in medium voltage, high power applications. DC bus short circuit protection is usually done, using the sensed voltage across collector and emitter (i.e., V-CE sensing), of all the devices in a leg. This feature is accommodated with the conventional gate drive circuits used in the two level converters. The similar gate drive circuit, when adopted for NPC three level converter protection, leads to false V-CE fault signals for inner devices of the leg. The paper explains the detailed circuit behavior and reasons, which result in the occurrence of such false V-CE fault signals. This paper also illustrates that such a phenomenon shows dependence on the power factor of the supplied three-phase load. Finally, experimental results are presented to support the analysis. It is shown that the problem can be avoided by blocking out the V-CE sense fault signals of the inner devices of the leg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The protective ability of cytotoxic T cells (CTL) raised in vitro against Japanese encephalitis virus (JEV) was examined by adoptive transfer experiments. Adoptive transfer of anti-JEV effecters by intracerebral (i.c.) but not by intraperitoneal (i.p.) or intravenous (i.v.) routes protected adult BALB/c mice against lethal i.c. JEV challenge. In contrast to adult mice, adoptive transfer of anti-JEV effecters into newborn (4-day-old) and suckling (8-14-day-old) mice did not confer protection. However, virus-induced death was delayed in suckling mice compared to newborn mice upon adoptive transfer. The specific reasons for lack of protection in newborn mice are not clear but virus load was found to be higher in newborn mice brains compared to those of adults and virus clearance was observed only in adult mice brains but not in newborn mice brains upon adoptive transfer. Specific depletion of Lyt 2.2(+), L3T4(+) or Thy-1(+) T cell populations before adoptive transfer abrogated the protective ability of transferred effecters. However, when Lyt 2.2(+) cell-depleted and L3T4(+) cell-depleted effecters were mixed and transferred into adult mice the protective activity was retained, demonstrating that both Lyt 2.2(+) and L3T4(+) T cells are necessary to confer protection. Although the presence of L3T4(+) T cells in adoptively transferred effector populations enhanced virus-specific serum neutralizing antibodies, the presence of neutralizing antibodies alone without Lyt 2.2(+) cells was not sufficient to confer protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design and development of a comprehensive digital protection scheme for applications in 25 KV a.c railway traction system. The scheme provides distance protection, detection of wrong phase coupling both in the lagging and leading directions, high set instantaneous trip and PT fuse failure. Provision is also made to include fault location and disturbance recording. The digital relaying scheme has been tried on two types of hardware platforms, one with PC/AT based hardware and the other with a custom designed standalone 16-bit microcontroller based card. Compared to the existing scheme, the operating time is around one cycle and the relaying algorithm has been optimised to minimise the number of computations. The prototype has been rigorously tested in the laboratory using a specially designed PC based relay test bench and the results are highly satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxidative damage, through increased production of free radicals, is believed to be involved in UV-induced cataractogenesis (eye lens opacification). The possibility of UVB radiation causing damage to important lenticular enzymes was assessed by irradiating 3 months old rat lenses (in RPMI-1640 medium) at 300 nm (100 mu Wcm(-2)) for 24 h, in the absence and presence of ascorbic acid, alpha-tocopherol acetate and beta-carotene. UVB irradiation resulted in decreased activities of hexokinase, glucose-6-phosphate dehydrogenase, aldose reductase, and Na, K- ATPase by 42, 40, 44 and 57% respectively. While endopeptidase activity (229%) and lipid peroxidation (156%) were increased, isocitrate dehydrogenase activity was not altered on irradiation. In the presence of externally added ascorbic acid, tocopherol and beta-carotene (separately) to the medium, the changes in enzyme activities (except endopeptidase) and increased lipid peroxidation, due to UVB exposure, were prevented. These results suggest that UVB radiation exerts oxidative damage on lens enzymes and antioxidants were protective against this damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents an adaptive Fourier filtering technique and a relaying scheme based on a combination of a digital band-pass filter along with a three-sample algorithm, for applications in high-speed numerical distance protection. To enhance the performance of above-mentioned technique, a high-speed fault detector has been used. MATLAB based simulation studies show that the adaptive Fourier filtering technique provides fast tripping for near faults and security for farther faults. The digital relaying scheme based on a combination of digital band-pass filter along with three-sample data window algorithm also provides accurate and high-speed detection of faults. The paper also proposes a high performance 16-bit fixed point DSP (Texas Instruments TMS320LF2407A) processor based hardware scheme suitable for implementation of the above techniques. To evaluate the performance of the proposed relaying scheme under steady state and transient conditions, PC based menu driven relay test procedures are developed using National Instruments LabVIEW software. The test signals are generated in real time using LabVIEW compatible analog output modules. The results obtained from the simulation studies as well as hardware implementations are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new technique is presented using principles of multisignal relaying for the synthesis of a universal-type quadrilateral polar characteristic. The modus operandi consists in the determination of the phase sequence of a set of voltage phasors and the provision of a trip signal for one sequence while blocking for the other. Two versions, one using ferrite-core logic and another using transistor logic, are described in detail. The former version has the merit of simplicity and has the added advantage of not requiring any d.c. supply. The unit is flexible, as it permits independent control of the characteristic along the resistance and reactance axis through suitable adjustments of replica impedance angles. The maximum operating time is about 20ms for all switching angles, and with faults within 95% of the protected section. The maximum transient overreach is about 8%.