858 resultados para FRACTURE MECHANICS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to develop a hip screening tool that combines relevant clinical risk factors (CRFs) and quantitative ultrasound (QUS) at the heel to determine the 10-yr probability of hip fractures in elderly women. The EPISEM database, comprised of approximately 13,000 women 70 yr of age, was derived from two population-based white European cohorts in France and Switzerland. All women had baseline data on CRFs and a baseline measurement of the stiffness index (SI) derived from QUS at the heel. Women were followed prospectively to identify incident fractures. Multivariate analysis was performed to determine the CRFs that contributed significantly to hip fracture risk, and these were used to generate a CRF score. Gradients of risk (GR; RR/SD change) and areas under receiver operating characteristic curves (AUC) were calculated for the CRF score, SI, and a score combining both. The 10-yr probability of hip fracture was computed for the combined model. Three hundred seven hip fractures were observed over a mean follow-up of 3.2 yr. In addition to SI, significant CRFs for hip fracture were body mass index (BMI), history of fracture, an impaired chair test, history of a recent fall, current cigarette smoking, and diabetes mellitus. The average GR for hip fracture was 2.10 per SD with the combined SI + CRF score compared with a GR of 1.77 with SI alone and of 1.52 with the CRF score alone. Thus, the use of CRFs enhanced the predictive value of SI alone. For example, in a woman 80 yr of age, the presence of two to four CRFs increased the probability of hip fracture from 16.9% to 26.6% and from 52.6% to 70.5% for SI Z-scores of +2 and -3, respectively. The combined use of CRFs and QUS SI is a promising tool to assess hip fracture probability in elderly women, especially when access to DXA is limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research has been focused at the development of a tuned systematic design methodology, which gives the best performance in a computer aided environment and utilises a cross-technological approach, specially tested with and for laser processed microwave mechanics. A tuned design process scheme is also presented. Because of the currently large production volumes of microwave and radio frequency mechanics even slight improvements of design methodologies or manufacturing technologies would give reasonable possibilities for cost reduction. The typical number of required iteration cycles could be reduced to one fifth of normal. The research area dealing with the methodologies is divided firstly into a function-oriented, a performance-oriented or a manufacturability-oriented product design. Alternatively various approaches can be developed for a customer-oriented, a quality-oriented, a cost-oriented or an organisation-oriented design. However, the real need for improvements is between these two extremes. This means that the effective methodology for the designers should not be too limited (like in the performance-oriented design) or too general (like in the organisation-oriented design), but it should, include the context of the design environment. This is the area where the current research is focused. To test the developed tuned design methodology for laser processing (TDMLP) and the tuned optimising algorithm for laser processing (TOLP), seven different industrial product applications for microwave mechanics have been designed, CAD-modelled and manufactured by using laser in small production series. To verify that the performance of these products meets the required level and to ensure the objectiveness ofthe results extensive laboratory tests were used for all designed prototypes. As an example a Ku-band horn antenna can be laser processed from steel in 2 minutes at the same time obtaining a comparable electrical performance of classical aluminium units or the residual resistance of a laser joint in steel could be limited to 72 milliohmia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The questions studied in this thesis are centered around the moment operators of a quantum observable, the latter being represented by a normalized positive operator measure. The moment operators of an observable are physically relevant, in the sense that these operators give, as averages, the moments of the outcome statistics for the measurement of the observable. The main questions under consideration in this work arise from the fact that, unlike a projection valued observable of the von Neumann formulation, a general positive operator measure cannot be characterized by its first moment operator. The possibility of characterizing certain observables by also involving higher moment operators is investigated and utilized in three different cases: a characterization of projection valued measures among all the observables is given, a quantization scheme for unbounded classical variables using translation covariant phase space operator measures is presented, and, finally, a mathematically rigorous description is obtained for the measurements of rotated quadratures and phase space observables via the high amplitude limit in the balanced homodyne and eight-port homodyne detectors, respectively. In addition, the structure of the covariant phase space operator measures, which is essential for the above quantization, is analyzed in detail in the context of a (not necessarily unimodular) locally compact group as the phase space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to determine the impact of trabecular bone score on the probability of fracture above that provided by the clinical risk factors utilized in FRAX. We performed a retrospective cohort study of 33,352 women aged 40-99 years from the province of Manitoba, Canada, with baseline measurements of lumbar spine trabecular bone score (TBS) and FRAX risk variables. The analysis was cohort-specific rather than based on the Canadian version of FRAX. The associations between trabecular bone score, the FRAX risk factors and the risk of fracture or death were examined using an extension of the Poisson regression model and used to calculate 10-year probabilities of fracture with and without TBS and to derive an algorithm to adjust fracture probability to take account of the independent contribution of TBS to fracture and mortality risk. During a mean follow-up of 4.7 years, 1754 women died and 1639 sustained one or more major osteoporotic fractures excluding hip fracture and 306 women sustained one or more hip fracture. When fully adjusted for FRAX risk variables, TBS remained a statistically significant predictor of major osteoporotic fractures excluding hip fracture (HR/SD 1.18, 95 % CI 1.12-1.24), death (HR/SD 1.20, 95 % CI 1.14-1.26) and hip fracture (HR/SD 1.23, 95 % CI 1.09-1.38). Models adjusting major osteoporotic fracture and hip fracture probability were derived, accounting for age and trabecular bone score with death considered as a competing event. Lumbar spine texture analysis using TBS is a risk factor for osteoporotic fracture and a risk factor for death. The predictive ability of TBS is independent of FRAX clinical risk factors and femoral neck BMD. Adjustment of fracture probability to take account of the independent contribution of TBS to fracture and mortality risk requires validation in independent cohorts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPORTANCE: Associations between subclinical thyroid dysfunction and fractures are unclear and clinical trials are lacking. OBJECTIVE: To assess the association of subclinical thyroid dysfunction with hip, nonspine, spine, or any fractures. DATA SOURCES AND STUDY SELECTION: The databases of MEDLINE and EMBASE (inception to March 26, 2015) were searched without language restrictions for prospective cohort studies with thyroid function data and subsequent fractures. DATA EXTRACTION: Individual participant data were obtained from 13 prospective cohorts in the United States, Europe, Australia, and Japan. Levels of thyroid function were defined as euthyroidism (thyroid-stimulating hormone [TSH], 0.45-4.49 mIU/L), subclinical hyperthyroidism (TSH <0.45 mIU/L), and subclinical hypothyroidism (TSH ≥4.50-19.99 mIU/L) with normal thyroxine concentrations. MAIN OUTCOME AND MEASURES: The primary outcome was hip fracture. Any fractures, nonspine fractures, and clinical spine fractures were secondary outcomes. RESULTS: Among 70,298 participants, 4092 (5.8%) had subclinical hypothyroidism and 2219 (3.2%) had subclinical hyperthyroidism. During 762,401 person-years of follow-up, hip fracture occurred in 2975 participants (4.6%; 12 studies), any fracture in 2528 participants (9.0%; 8 studies), nonspine fracture in 2018 participants (8.4%; 8 studies), and spine fracture in 296 participants (1.3%; 6 studies). In age- and sex-adjusted analyses, the hazard ratio (HR) for subclinical hyperthyroidism vs euthyroidism was 1.36 for hip fracture (95% CI, 1.13-1.64; 146 events in 2082 participants vs 2534 in 56,471); for any fracture, HR was 1.28 (95% CI, 1.06-1.53; 121 events in 888 participants vs 2203 in 25,901); for nonspine fracture, HR was 1.16 (95% CI, 0.95-1.41; 107 events in 946 participants vs 1745 in 21,722); and for spine fracture, HR was 1.51 (95% CI, 0.93-2.45; 17 events in 732 participants vs 255 in 20,328). Lower TSH was associated with higher fracture rates: for TSH of less than 0.10 mIU/L, HR was 1.61 for hip fracture (95% CI, 1.21-2.15; 47 events in 510 participants); for any fracture, HR was 1.98 (95% CI, 1.41-2.78; 44 events in 212 participants); for nonspine fracture, HR was 1.61 (95% CI, 0.96-2.71; 32 events in 185 participants); and for spine fracture, HR was 3.57 (95% CI, 1.88-6.78; 8 events in 162 participants). Risks were similar after adjustment for other fracture risk factors. Endogenous subclinical hyperthyroidism (excluding thyroid medication users) was associated with HRs of 1.52 (95% CI, 1.19-1.93) for hip fracture, 1.42 (95% CI, 1.16-1.74) for any fracture, and 1.74 (95% CI, 1.01-2.99) for spine fracture. No association was found between subclinical hypothyroidism and fracture risk. CONCLUSIONS AND RELEVANCE: Subclinical hyperthyroidism was associated with an increased risk of hip and other fractures, particularly among those with TSH levels of less than 0.10 mIU/L and those with endogenous subclinical hyperthyroidism. Further study is needed to determine whether treating subclinical hyperthyroidism can prevent fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebral fracture assessments (VFAs) using dual-energy X-ray absorptiometry increase vertebral fracture detection in clinical practice and are highly reproducible. Measures of reproducibility are dependent on the frequency and distribution of the event. The aim of this study was to compare 2 reproducibility measures, reliability and agreement, in VFA readings in both a population-based and a clinical cohort. We measured agreement and reliability by uniform kappa and Cohen's kappa for vertebral reading and fracture identification: 360 VFAs from a population-based cohort and 85 from a clinical cohort. In the population-based cohort, 12% of vertebrae were unreadable. Vertebral fracture prevalence ranged from 3% to 4%. Inter-reader and intrareader reliability with Cohen's kappa was fair to good (0.35-0.71 and 0.36-0.74, respectively), with good inter-reader and intrareader agreement by uniform kappa (0.74-0.98 and 0.76-0.99, respectively). In the clinical cohort, 15% of vertebrae were unreadable, and vertebral fracture prevalence ranged from 7.6% to 8.1%. Inter-reader reliability was moderate to good (0.43-0.71), and the agreement was good (0.68-0.91). In clinical situations, the levels of reproducibility measured by the 2 kappa statistics are concordant, so that either could be used to measure agreement and reliability. However, if events are rare, as in a population-based cohort, we recommend evaluating reproducibility using the uniform kappa, as Cohen's kappa may be less accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistical properties of binary complex networks are well understood and recently many attempts have been made to extend this knowledge to weighted ones. There are, however, subtle yet important considerations to be made regarding the nature of the weights used in this generalization. Weights can be either continuous or discrete magnitudes, and in the latter case, they can additionally have undistinguishable or distinguishable nature. This fact has not been addressed in the literature insofar and has deep implications on the network statistics. In this work we face this problem introducing multiedge networks as graphs where multiple (distinguishable) connections between nodes are considered. We develop a statistical mechanics framework where it is possible to get information about the most relevant observables given a large spectrum of linear and nonlinear constraints including those depending both on the number of multiedges per link and their binary projection. The latter case is particularly interesting as we show that binary projections can be understood from multiedge processes. The implications of these results are important as many real-agent-based problems mapped onto graphs require this treatment for a proper characterization of their collective behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Walking in patients with chronic low back pain (cLBP) is characterized by motor control adaptations as a protective strategy against further injury or pain. The purpose of this study was to compare the preferred walking speed, the biomechanical and the energetic parameters of walking at different speeds between patients with cLBP and healthy men individually matched for age, body mass and height. METHODS: Energy cost of walking was assessed with a breath-by-breath gas analyser; mechanical and spatiotemporal parameters of walking were computed using two inertial sensors equipped with a triaxial accelerometer and gyroscope and compared in 13 men with cLBP and 13 control men (CTR) during treadmill walking at standard (0.83, 1.11, 1.38, 1.67 m s(-1)) and preferred (PWS) speeds. Low back pain intensity (visual analogue scale, cLBP only) and perceived exertion (Borg scale) were assessed at each walking speed. RESULTS: PWS was slower in cLBP [1.17 (SD = 0.13) m s(-1)] than in CTR group [1.33 (SD = 0.11) m s(-1); P = 0.002]. No significant difference was observed between groups in mechanical work (P ≥ 0.44), spatiotemporal parameters (P ≥ 0.16) and energy cost of walking (P ≥ 0.36). At the end of the treadmill protocol, perceived exertion was significantly higher in cLBP [11.7 (SD = 2.4)] than in CTR group [9.9 (SD = 1.1); P = 0.01]. Pain intensity did not significantly increase over time (P = 0.21). CONCLUSIONS: These results do not support the hypothesis of a less efficient walking pattern in patients with cLBP and imply that high walking speeds are well tolerated by patients with moderately disabling cLBP.