955 resultados para Experimental evidence


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nanofabrication has allowed the development of new concepts such as magnetic logic and race-track memory, both of which are based on the displacement of magnetic domain walls on magnetic nanostripes. One of the issues that has to be solved before devices can meet the market demands is the stochastic behaviour of the domain wall movement in magnetic nanostripes. Here we show that the stochastic nature of the domain wall motion in permalloy nanostripes can be suppressed at very low fields (0.6-2.7 Oe). We also find different field regimes for this stochastic motion that match well with the domain wall propagation modes. The highest pinning probability is found around the precessional mode and, interestingly, it does not depend on the external field in this regime. These results constitute an experimental evidence of the intrinsic nature of the stochastic pinning of domain walls in soft magnetic nanostripes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The obtaining of multiferroicBiFeO3 as a pure single-phase product is particularly complex since the formation of secondary phases seems to be unavoidable. The process by which these secondary impurities are formed is studied by analyzing the diffusion and solidstate reactivity of the Bi2O3–Fe2O3 system. Experimental evidence is reported which indicates that the progressive diffusion of Bi3+ ions into the Fe2O3 particles governs the solidstatesynthesis of the perovskite BiFeO3 phase. However a competition is established between the diffusion process which tends to complete the formation of BiFeO3, and the crystallization of stable Bi2Fe4O9 mullite crystals, which tend to block that formation reaction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

While negation has been a very active área of research in logic programming, comparatively few papers have been devoted to implementation issues. Furthermore, the negation-related capabilities of current Prolog systems are limited. We recently presented a novel method for incorporating negation in a Prolog compiler which takes a number of existing methods (some modified and improved by us) and uses them in a combined fashion. The method makes use of information provided by a global analysis of the source code. Our previous work focused on the systematic description of the techniques and the reasoning about correctness and completeness of the method, but provided no experimental evidence to evalúate the proposal. In this paper, we report on an implementation, using the Ciao Prolog system preprocessor, and provide experimental data which indicates that the method is not only feasible but also quite promising from the efficiency point of view. In addition, the tests have provided new insight as to how to improve the proposal further. Abstract interpretation techniques are shown to offer important improvements in this application.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

While negation has been a very active área of research in logic programming, comparatively few papers have been devoted to implementation issues. Furthermore, the negation-related capabilities of current Prolog systems are limited. We recently presented a novel method for incorporating negation in a Prolog compiler which takes a number of existing methods (some modified and improved) and uses them in a combined fashion. The method makes use of information provided by a global analysis of the source code. Our previous work focused on the systematic description of the techniques and the reasoning about correctness and completeness of the method, but provided no experimental evidence to evalúate the proposal. In this paper, after proposing some extensions to the method, we provide experimental data which indicates that the method is not only feasible but also quite promising from the efficiency point of view. In addition, the tests have provided new insight as to how to improve the proposal further. Abstract interpretation techniques (in particular those included in the Ciao Prolog system preprocessor) have had a significant role in the success of the technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta memoria está basada en el crecimiento y caracterización de heteroestructuras Al(Ga)N/GaN y nanocolumnas ordenadas de GaN, y su aplicación en sensores químicos. El método de crecimiento ha sido la epitaxia de haces moleculares asistida por plasma (PAMBE). En el caso de las heteroestructuras Al(Ga)N/GaN, se han crecido barreras de distinto espesor y composición, desde AlN de 5 nm, hasta AlGaN de 35 nm. Además de una caracterización morfológica, estructural y eléctrica básica de las capas, también se han fabricado a partir de ellas dispositivos tipo HEMTs. La caracterización eléctrica de dichos dispositivos (carga y movilidad de en el canal bidimensional) indica que las mejores heteroestructuras son aquellas con un espesor de barrera intermedio (alrededor de 20 nm). Sin embargo, un objetivo importante de esta Tesis ha sido verificar las ventajas que podían tener los sensores basados en heteroestructuras AlN/GaN (frente a los típicos basados en AlGaN/GaN), con espesores de barrera muy finos (alrededor de 5 nm), ya que el canal de conducción que se modula por efecto de cambios químicos está más cerca de la superficie en donde ocurren dichos cambios químicos. De esta manera, se han utilizado los dispositivos tipo HEMTs como sensores químicos de pH (ISFETs), y se ha comprobado la mayor sensibilidad (variación de corriente frente a cambios de pH, Ids/pH) en los sensores basados en AlN/GaN frente a los basados en AlGaN/GaN. La mayor sensibilidad es incluso más patente en aplicaciones en las que no se utiliza un electrodo de referencia. Se han fabricado y caracterizado dispositivos ISFET similares utilizando capas compactas de InN. Estos sensores presentan peor estabilidad que los basados en Al(Ga)N/GaN, aunque la sensibilidad superficial al pH era la misma (Vgs/pH), y su sensibilidad en terminos de corriente de canal (Ids/pH) arroja valores intermedios entre los ISFET basados en AlN/GaN y los valores de los basados en AlGaN/GaN. Para continuar con la comparación entre dispositivos basados en Al(Ga)N/GaN, se fabricaron ISFETs con el área sensible más pequeña (35 x 35 m2), de tamaño similar a los dispositivos destinados a las medidas de actividad celular. Sometiendo los dispositivos a pulsos de voltaje en su área sensible, la respuesta de los dispositivos de AlN presentaron menor ruido que los basados en AlGaN. El ruido en la corriente para dispositivos de AlN, donde el encapsulado no ha sido optimizado, fue tan bajo como 8.9 nA (valor rms), y el ruido equivalente en el potencial superficial 38.7 V. Estos valores son más bajos que los encontrados en los dispositivos típicos para la detección de actividad celular (basados en Si), y del orden de los mejores resultados encontrados en la literatura sobre AlGaN/GaN. Desde el punto de vista de la caracterización electro-química de las superficies de GaN e InN, se ha determinado su punto isoeléctrico. Dicho valor no había sido reportado en la literatura hasta el momento. El valor, determinado por medidas de “streaming potential”, es de 4.4 y 4 respectivamente. Este valor es una importante característica a tener en cuenta en sensores, en inmovilización electrostática o en la litografía coloidal. Esta última técnica se discute en esta memoria, y se aplica en el último bloque de investigación de esta Tesis (i.e. crecimiento ordenado). El último apartado de resultados experimentales de esta Tesis analiza el crecimiento selectivo de nanocolumnas ordenadas de GaN por MBE, utilizando mascaras de Ti con nanoagujeros. Se ha estudiado como los distintos parámetros de crecimiento (i.e. flujos de los elementos Ga y N, temperatura de crecimiento y diseño de la máscara) afectan a la selectividad y a la morfología de las nanocolumnas. Se ha conseguido con éxito el crecimiento selectivo sobre pseudosustratos de GaN con distinta orientación cristalina o polaridad; templates de GaN(0001)/zafiro, GaN(0001)/AlN/Si, GaN(000-1)/Si y GaN(11-20)/zafiro. Se ha verificado experimentalmente la alta calidad cristalina de las nanocolumnas ordenadas, y su mayor estabilidad térmica comparada con las capas compactas del mismo material. Las nanocolumnas ordenadas de nitruros del grupo III tienen una clara aplicación en el campo de la optoelectrónica, principalmente para nanoemisores de luz blanca. Sin embargo, en esta Tesis se proponen como alternativa a la utilización de capas compactas o nanocolumnas auto-ensambladas en sensores. Las nanocolumnas auto-ensambladas de GaN, debido a su alta razón superficie/volumen, son muy prometedoras en el campo de los sensores, pero su amplia dispersión en dimensiones (altura y diámetro) supone un problema para el procesado y funcionamiento de dispositivos reales. En ese aspecto, las nanocolumnas ordenadas son más robustas y homogéneas, manteniendo una alta relación superficie/volumen. Como primer experimento en el ámbito de los sensores, se ha estudiado como se ve afectada la emisión de fotoluminiscencia de las NCs ordenadas al estar expuestas al aire o al vacio. Se observa una fuerte caída en la intensidad de la fotoluminiscencia cuando las nanocolumnas están expuestas al aire (probablemente por la foto-adsorción de oxigeno en la superficie), como ya había sido documentado anteriormente en nanocolumnas auto-ensambladas. Este experimento abre el camino para futuros sensores basados en nanocolumnas ordenadas. Abstract This manuscript deals with the growth and characterization of Al(Ga)N/GaN heterostructures and GaN ordered nanocolumns, and their application in chemical sensors. The growth technique has been the plasma-assisted molecular beam epitaxy (PAMBE). In the case of Al(Ga)N/GaN heterostructures, barriers of different thickness and composition, from AlN (5 nm) to AlGaN (35 nm) have been grown. Besides the basic morphological, structural and electrical characterization of the layers, HEMT devices have been fabricated based on these layers. The best electrical characteristics (larger carriers concentration and mobility in the two dimensional electron gas) are those in AlGaN/GaN heterostructures with a medium thickness (around 20 nm). However, one of the goals of this Thesis has been to verify the advantages that sensors based on AlN/GaN (thickness around 7 nm) have compared to standard AlGaN/GaN, because the conduction channel to be modulated by chemical changes is closer to the sensitive area. In this way, HEMT devices have been used as chemical pH sensors (ISFETs), and the higher sensitivity (conductance change related to pH changes, Ids/pH) of AlN/GaN based sensors has been proved. The higher sensibility is even more obvious in application without reference electrode. Similar ISFETs devices have been fabricated based on InN compact layers. These devices show a poor stability, but its surface sensitivity to pH (Vgs/pH) and its sensibility (Ids/pH) yield values between the corresponding ones of AlN/GaN and AlGaN/GaN heterostructures. In order to a further comparison between Al(Ga)N/GaN based devices, ISFETs with smaller sensitive area (35 x 35 m2), similar to the ones used in cellular activity record, were fabricated and characterized. When the devices are subjected to a voltage pulse through the sensitive area, the response of AlN based devices shows lower noise than the ones based on AlGaN. The noise in the current of such a AlN based device, where the encapsulation has not been optimized, is as low as 8.9 nA (rms value), and the equivalent noise to the surface potential is 38.7 V. These values are lower than the found in typical devices used for cellular activity recording (based on Si), and in the range of the best published results on AlGaN/GaN. From the point of view of the electrochemical characterization of GaN and InN surfaces, their isoelectric point has been experimentally determined. Such a value is the first time reported for GaN and InN surfaces. These values are determined by “streaming potential”, being pH 4.4 and 4, respectively. Isoelectric point value is an important characteristic in sensors, electrostatic immobilization or in colloidal lithography. In particular, colloidal lithography has been optimized in this Thesis for GaN surfaces, and applied in the last part of experimental results (i.e. ordered growth). The last block of this Thesis is focused on the selective area growth of GaN nanocolumns by MBE, using Ti masks decorated with nanoholes. The effect of the different growth parameters (Ga and N fluxes, growth temperature and mask design) is studied, in particular their impact in the selectivity and in the morphology of the nanocolumns. Selective area growth has been successful performed on GaN templates with different orientation or polarity; GaN(0001)/sapphire, GaN(0001)/AlN/Si, GaN(000- 1)/Si and GaN(11-20)/sapphire. Ordered nanocolumns exhibit a high crystal quality, and a higher thermal stability (lower thermal decomposition) than the compact layers of the same material. Ordered nanocolumns based on III nitrides have a clear application in optoelectronics, mainly for white light nanoemitters. However, this Thesis proposes them as an alternative to compact layers and self-assembled nanocolumns in sensor applications. Self-assembled GaN nanocolumns are very appealing for sensor applications, due to their large surface/volume ratio. However, their large dispersion in heights and diameters are a problem in terms of processing and operation of real devices. In this aspect, ordered nanocolumns are more robust and homogeneous, keeping the large surface/volume ratio. As first experimental evidence of their sensor capabilities, ordered nanocolumns have been studied regarding their photoluminiscence on air and vacuum ambient. A big drop in the intensity is observed when the nanocolumns are exposed to air (probably because of the oxygen photo-adsortion), as was already reported in the case of self-assembled nanocolumns. This opens the way to future sensors based on ordered III nitrides nanocolumns.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tradicionalmente, la fabricación de materiales compuestos de altas prestaciones se lleva a cabo en autoclave mediante la consolidación de preimpregnados a través de la aplicación simultánea de altas presiones y temperatura. Las elevadas presiones empleadas en autoclave reducen la porosidad de los componentes garantizando unas buenas propiedades mecánicas. Sin embargo, este sistema de fabricación conlleva tiempos de producción largos y grandes inversiones en equipamiento lo que restringe su aplicación a otros sectores alejados del sector aeronáutico. Este hecho ha generado una creciente demanda de sistemas de fabricación alternativos al autoclave. Aunque estos sistemas son capaces de reducir los tiempos de producción y el gasto energético, por lo general, dan lugar a materiales con menores prestaciones mecánicas debido a que se reduce la compactación del material al aplicar presiones mas bajas y, por tanto, la fracción volumétrica de fibras, y disminuye el control de la porosidad durante el proceso. Los modelos numéricos existentes permiten conocer los fundamentos de los mecanismos de crecimiento de poros durante la fabricación de materiales compuestos de matriz polimérica mediante autoclave. Dichos modelos analizan el comportamiento de pequeños poros esféricos embebidos en una resina viscosa. Su validez no ha sido probada, sin embargo, para la morfología típica observada en materiales compuestos fabricados fuera de autoclave, consistente en poros cilíndricos y alargados embebidos en resina y rodeados de fibras continuas. Por otro lado, aunque existe una clara evidencia experimental del efecto pernicioso de la porosidad en las prestaciones mecánicas de los materiales compuestos, no existe información detallada sobre la influencia de las condiciones de procesado en la forma, fracción volumétrica y distribución espacial de los poros en los materiales compuestos. Las técnicas de análisis convencionales para la caracterización microestructural de los materiales compuestos proporcionan información en dos dimensiones (2D) (microscopía óptica y electrónica, radiografía de rayos X, ultrasonidos, emisión acústica) y sólo algunas son adecuadas para el análisis de la porosidad. En esta tesis, se ha analizado el efecto de ciclo de curado en el desarrollo de los poros durante la consolidación de preimpregnados Hexply AS4/8552 a bajas presiones mediante moldeo por compresión, en paneles unidireccionales y multiaxiales utilizando tres ciclos de curado diferentes. Dichos ciclos fueron cuidadosamente diseñados de acuerdo a la caracterización térmica y reológica de los preimpregnados. La fracción volumétrica de poros, su forma y distribución espacial se analizaron en detalle mediante tomografía de rayos X. Esta técnica no destructiva ha demostrado su capacidad para analizar la microestructura de materiales compuestos. Se observó, que la porosidad depende en gran medida de la evolución de la viscosidad dinámica a lo largo del ciclo y que la mayoría de la porosidad inicial procedía del aire atrapado durante el apilamiento de las láminas de preimpregnado. En el caso de los laminados multiaxiales, la porosidad también se vio afectada por la secuencia de apilamiento. En general, los poros tenían forma cilíndrica y se estaban orientados en la dirección de las fibras. Además, la proyección de la población de poros a lo largo de la dirección de la fibra reveló la existencia de una estructura celular de un diámetro aproximado de 1 mm. Las paredes de las celdas correspondían con regiones con mayor densidad de fibra mientras que los poros se concentraban en el interior de las celdas. Esta distribución de la porosidad es el resultado de una consolidación no homogenea. Toda esta información es crítica a la hora de optimizar las condiciones de procesado y proporcionar datos de partida para desarrollar herramientas de simulación de los procesos de fabricación de materiales compuestos fuera de autoclave. Adicionalmente, se determinaron ciertas propiedades mecánicas dependientes de la matriz termoestable con objeto de establecer la relación entre condiciones de procesado y las prestaciones mecánicas. En el caso de los laminados unidireccionales, la resistencia interlaminar depende de la porosidad para fracciones volumétricas de poros superiores 1%. Las mismas tendencias se observaron en el caso de GIIc mientras GIc no se vio afectada por la porosidad. En el caso de los laminados multiaxiales se evaluó la influencia de la porosidad en la resistencia a compresión, la resistencia a impacto a baja velocidad y la resistencia a copresión después de impacto. La resistencia a compresión se redujo con el contenido en poros, pero éste no influyó significativamente en la resistencia a compresión despues de impacto ya que quedó enmascarada por otros factores como la secuencia de apilamiento o la magnitud del daño generado tras el impacto. Finalmente, el efecto de las condiciones de fabricación en el proceso de compactación mediante moldeo por compresión en laminados unidireccionales fue simulado mediante el método de los elementos finitos en una primera aproximación para simular la fabricación de materiales compuestos fuera de autoclave. Los parámetros del modelo se obtuvieron mediante experimentos térmicos y reológicos del preimpregnado Hexply AS4/8552. Los resultados obtenidos en la predicción de la reducción de espesor durante el proceso de consolidación concordaron razonablemente con los resultados experimentales. Manufacturing of high performance polymer-matrix composites is normally carried out by means of autoclave using prepreg tapes stacked and consolidated under the simultaneous application of pressure and temperature. High autoclave pressures reduce the porosity in the laminate and ensure excellent mechanical properties. However, this manufacturing route is expensive in terms of capital investment and processing time, hindering its application in many industrial sectors. This fact has driven the demand of alternative out-of-autoclave processing routes. These techniques claim to produce composite parts faster and at lower cost but the mechanical performance is also reduced due to the lower fiber content and to the higher porosity. Corrient numerical models are able to simulate the mechanisms of void growth in polymer-matrix composites processed in autoclave. However these models are restricted to small spherical voids surrounded by a viscous resin. Their validity is not proved for long cylindrical voids in a viscous matrix surrounded by aligned fibers, the standard morphology observed in out-of-autoclave composites. In addition, there is an experimental evidence of the detrimental effect of voids on the mechanical performance of composites but, there is detailed information regarding the influence of curing conditions on the actual volume fraction, shape and spatial distribution of voids within the laminate. The standard techniques of microstructural characterization of composites (optical or electron microscopy, X-ray radiography, ultrasonics) provide information in two dimensions and are not always suitable to determine the porosity or void population. Moreover, they can not provide 3D information. The effect of curing cycle on the development of voids during consolidation of AS4/8552 prepregs at low pressure by compression molding was studied in unidirectional and multiaxial panels. They were manufactured using three different curing cycles carefully designed following the rheological and thermal analysis of the raw prepregs. The void volume fraction, shape and spatial distribution were analyzed in detail by means of X-ray computed microtomography, which has demonstrated its potential for analyzing the microstructural features of composites. It was demonstrated that the final void volume fraction depended on the evolution of the dynamic viscosity throughout the cycle. Most of the initial voids were the result of air entrapment and wrinkles created during lay-up. Differences in the final void volume fraction depended on the processing conditions for unidirectional and multiaxial panels. Voids were rod-like shaped and were oriented parallel to the fibers and concentrated in channels along the fiber orientation. X-ray computer tomography analysis of voids along the fiber direction showed a cellular structure with an approximate cell diameter of 1 mm. The cell walls were fiber-rich regions and porosity was localized at the center of the cells. This porosity distribution within the laminate was the result of inhomogeneous consolidation. This information is critical to optimize processing parameters and to provide inputs for virtual testing and virtual processing tools. In addition, the matrix-controlled mechanical properties of the panels were measured in order to establish the relationship between processing conditions and mechanical performance. The interlaminar shear strength (ILSS) and the interlaminar toughness (GIc and GIIc) were selected to evaluate the effect of porosity on the mechanical performance of unidirectional panels. The ILSS was strongly affected by the porosity when the void contents was higher than 1%. The same trends were observed in the case of GIIc while GIc was insensitive to the void volume fraction. Additionally, the mechanical performance of multiaxial panels in compression, low velocity impact and compression after impact (CAI) was measured to address the effect of processing conditions. The compressive strength decreased with porosity and ply-clustering. However, the porosity did not influence the impact resistance and the coompression after impact strength because the effect of porosity was masked by other factors as the damage due to impact or the laminate lay-up. Finally, the effect of the processing conditions on the compaction behavior of unidirectional AS4/8552 panels manufactured by compression moulding was simulated using the finite element method, as a first approximation to more complex and accurate models for out-of autoclave curing and consolidation of composite laminates. The model parameters were obtained from rheological and thermo-mechanical experiments carried out in raw prepreg samples. The predictions of the thickness change during consolidation were in reasonable agreement with the experimental results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The obtaining of multiferroic BiFeO3 as a pure single-phase product is particularly complex since the formation of secondary phases seems to be unavoidable. The process by which these secondary impurities are formed is studied by analyzing the diffusion and solid state reactivity of the Bi2O3?Fe2O3 system. Experimental evidence is reported which indicates that the progressive diffusion of Bi3+ ions into the Fe2O3 particles governs the solid state synthesis of the perovskite BiFeO3 phase. However a competition is established between the diffusion process which tends to complete the formation of BiFeO3, and the crystallization of stable Bi2Fe4O9 mullite crystals, which tend to block that formation reaction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The impedance-based stability-assessment method has turned out to be a very effective tool and its usage is rapidly growing in different applications ranging from the conventional interconnected dc/dc systems to the grid-connected renewable energy systems. The results are sometime given as a certain forbidden region in the complex plane out of which the impedance ratio--known as minor-loop gain--shall stay for ensuring robust stability. This letter discusses the circle-like forbidden region occupying minimum area in the complex plane, defined by applying maximum peak criteria, which is well-known theory in control engineering. The investigation shows that the circle-like forbidden region will ensure robust stability only if the impedance-based minor-loop gain is determined at the very input or output of each subsystem within the interconnected system. Experimental evidence is provided based on a small-scale dc/dc distributed system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Wide experimental evidence of the phosphorus diffusion gettering beneficial effect on solar grade silicon is found by measuring electron effective lifetime and interstitial iron concentration in as-grown and post processed samples from two ingots of upgraded metallurgical grade silicon produced by Ferrosolar. Results after two different P-diffusion processes are compared: P emitter diffusion at 850ºC followed by fast cool-down (called “standard process”) or followed by slow cool-down (called “extended process”). It is shown that final lifetimes of this low cost material are in the range of those obtained with conventional material. The extended process can be beneficial for wafers with specific initial distribution and concentration of iron, e.g. materials with high concentration of big Fe precipitates, while for other cases the standard process is enough efficient. An analysis based on the comparison of measured lifetime and dissolved iron concentration with theoretical calculations helps to infer the initial iron distribution and concentration, and according to that, choose the more effective type of gettering.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las estructuras de hormigón son susceptibles de sufrir los efectos asociados a las acciones de fatiga cuando estas se ven sometidas a un elevado número de cargas repetidas. Muchas de estas estructuras no requieren armadura transversal para cumplir los condicionantes de dimensionamiento estático como por ejemplo las losas superiores de tableros de puentes, los muros de contención, las losas de transición de puentes, las torres eólicas o las estructuras marítimas. La mayor parte de los códigos de diseño vigentes no incluyen una comprobación específica del nivel de seguridad a cortante de estas estructuras para acciones de fatiga, y aquellas que lo hacen prefieren utilizar expresiones de tipo empírico basadas en curvas S-N que relacionan el número de ciclos resistentes con el valor de la carga aplicada. A pesar de que el empleo de curvas S-N es de gran utilidad desde un punto de vista práctico, estas curvas no permiten comprender el proceso de rotura por cortante para cargas repetidas. El objetivo principal de esta Tesis es el de estudiar el comportamiento a cortante de elementos de hormigón armado sin cercos sometidos a fatiga. Además, el análisis es ampliado al estudio del comportamiento transversal de los voladizos de las losas superiores de tableros de puentes de hormigón que de forma habitual son diseñados sin armadura de cortante. De forma habitual estos elementos se diseñan atendiendo a criterios de dimensionamiento estáticos sin tener en cuenta la resistencia a cortante cuando se ven sometidos a cargas cíclicas. A pesar de que las cargas de fatiga son inferiores a aquellas que producen el fallo estático, es importante tener en cuenta el comportamiento de estos elementos ante cargas repetidas. Los trabajos experimentales existentes en vigas de hormigón armado sin cercos evidenciaron diferencias significativas entre los modos de fallo ante cargas estáticas y cíclicas. Estos trabajos llegaron a la conclusión de que estos elementos diseñados para tener un fallo dúctil por flexión pueden llegar a desarrollar un tipo de fallo frágil por cortante cuando se ven sometidos a cargas repetidas. El proceso de rotura por cortante en elementos de hormigón armado sin cercos sometidos a fatiga es un proceso complejo que debe ser estudiado en profundidad debido al carácter frágil de este tipo de fallo. Los trabajos experimentales permitieron comprobar que el origen de este fallo tiene lugar tras la formación de una fisura de cortante a partir de una fisura de flexión formada durante los primeros ciclos en el vano de cortante. Tras la formación de esta fisura, esta se va propagando hacia la cabeza de compresión hasta que finalmente se produce el fallo como consecuencia de la destrucción de la cabeza de compresión cuando la altura alcanzada por esta es insuficiente para resistir la fuerza de compresión aplicada en esta zona. Por otra parte, la propagación de esta fisura diagonal puede desarrollarse por completo en el instante en el que esta se forma derivando en un tipo de fallo por cortante más frágil que el anterior. El proceso de fatiga es estudiado en esta Tesis mediante un modelo mecánico. Por una parte, se propone un modelo predictivo para determinar el número de ciclos acumulados hasta que se forma la fisura diagonal en función del estado tensional que se tiene en la punta de una fisura crítica de flexión formada en los primeros ciclos. Por otra parte, la resistencia a fatiga tras la formación de la fisura diagonal se analiza teniendo en cuenta el daño por fatiga acumulado en la cabeza de compresión y las variables que afectan a la propagación de esta fisura de cortante. Para la evaluación de la resistencia a fatiga tras la formación de la fisura crítica de cortante en este tipo de elementos, se plantea un modelo teórico basado en conceptos de Mecánica de la Fractura adaptados al hormigón. Este modelo puede ser aplicado a vigas de hormigón armado sin cercos de canto constante o variable siguiendo diferentes procedimientos. Una campaña experimental ha sido llevada a cabo con el objetivo de estudiar el comportamiento a cortante de vigas de hormigón armado sin cercos de canto variable sometidas a cargas estáticas y de fatiga. Se han desarrollado un total de diez ensayos estáticos y de fatiga para diferentes niveles de carga y esbelteces de cortante, teniendo lugar diferentes modos de fallo. Estos elementos fueron diseñados para reproducir, a escala real y de forma simplificada, los voladizos laterales de las losas superiores de tableros de puentes de carretera de hormigón. Los resultados experimentales demostraron que el tipo de fallo desarrollado depende de varios parámetros como por ejemplo el nivel de carga máxima, el nivel de oscilación de tensiones en la armadura longitudinal, la esbeltez de cortante o la calidad del hormigón utilizado entre otros. Para valores similares de esbeltez de cortante, los ensayos de fatiga realizados permitieron comprobar que la rotura por cortante de estos elementos está asociada a niveles de carga máxima elevados, mientras que el fallo por fatiga de la armadura longitudinal tiene mayor probabilidad de ocurrir en elementos sometidos a elevados niveles de oscilación de tensiones en esta armadura. Además, estos ensayos han sido analizados a través del modelo propuesto para tratar de comprender el comportamiento resistente de estos elementos sometidos a cargas de fatiga. Concrete structures are able to suffer fatigue when they are subjected to high number of cyclic loads. Many of these need not shear reinforcement to satisfy static design requirements, such as bridge deck slabs, retaining walls, bridge approach slabs, wind towers or maritime structures among others. Many codes of practice do not include a verification of the shear fatigue safety. Moreover, those which include it still prefer empirical S-N-based approaches that provide the number of cycles as a function of applied forces. S-N models are practical but they do not provide information to understand the shear fatigue process. The main objective of this Thesis is to study shear behaviour of reinforced concrete elements without stirrups subjected to fatigue loads. In addition, the analysis is extended in order to study the transverse behaviour of cantilever slabs of concrete bridges that traditionally are designed without shear reinforcement. These elements usually are designed on the basis of static strength and it is unusual that codes consider fatigue strength of concrete in shear. Accordingly, it is important to take into account the fatigue behaviour of structural members subjected to cyclic loads although these loads are lower than those which produce the static failure. Existing experimental works show important differences between the static and cyclic failure modes of reinforced concrete beams without stirrups. These works concluded that beams without transverse reinforcement, designed to have a ductile failure mode in flexure, can submit a brittle shear failure mode when they are subjected to repeated loads. Shear fatigue failure of reinforced concrete beams without stirrups is a rather complex process from the mechanical viewpoint. Since it leads to a brittle failure mode it should be better understood. Experimental evidence indicates that a diagonal crack first develops from the inclination of flexural cracks in the shear span. Thereafter, the diagonal crack propagates into the compression zone. Failure normally takes place by the destruction of the compression zone when its depth is too small to resist the applied force. The propagation of the diagonal crack can also be instantaneous, leading to sudden diagonal cracking fatigue failure rather than shear-compression failure. Fatigue process is studied in this Thesis on a mechanical basis. On the one hand, a predictive model is derived to obtain the number of cycles up to diagonal cracking, as a function of the stress state at the tip of a critical flexural crack. On the other hand, the residual fatigue strength after diagonal cracking is analyzed taking into account the fatigue damage accumulated by the compression zone and the variables affecting the propagation of the diagonal crack. In order to assess the residual fatigue strength after diagonal cracking of such elements, a theoretical model is proposed based on concepts from fracture mechanics adapted to concrete. This model can be successfully applied for straight or haunched reinforced concrete beams without stirrups following different procedures. In order to achieve a more advanced knowledge in this subject, an experimental campaign has been carried out with the aim of study the shear behaviour of reinforced concrete haunched beams without stirrups subjected to static and fatigue loads. A total of ten static and fatigue tests have been performed with distinct load levels and shear span-to-depth ratios, presenting different failures modes. These elements were designed to reproduce in a simplified form the cantilever slab of concrete bridges at real scale. Experimental results showed that the type of failure depends on several parameters as for example the maximum load level, the stress oscillation level on the longitudinal reinforcement, the shear span-to-depth ratio or the quality of the concrete used among others. For a similar value of the shear span-to-depth ratio, tests evidenced that shear fatigue failure is related to high maximum load levels, while steel fatigue failure is easier to occur in elements subjected to high stress oscillation level on the reinforcement bars. Besides, these tests have been analyzed through the proposed model in order to clarify the structural behaviour of such elements subjected to fatigue loads.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En este trabajo se estudia el comportamiento de elementos de hormigón estructural sometidos a deformaciones impuestas, en donde la fisuración se produce, general y fundamentalmente, en secciones en las que los esfuerzos, y por tanto las fisuras, debidos a las acciones exteriores son inexistentes o prácticamente inexistentes. Se estudia la fisuración producida, a edades tempranas, por las deformaciones debidas al calor de fraguado y la retracción autógena y a lo largo de la vida útil de la estructura, por los fenómenos reológicos del hormigón y la variación de temperatura. Se han estudiado los resultados experimentales disponibles. Se ha identificado un programa de elementos finitos, ATENA, que permite el estudio de fenómenos no lineales, especialmente la fisuración. Se ha contrastado este programa de forma detallada con los resultados experimentales disponibles. Se han estudiado las fuentes de deformaciones impuestas para su caracterización: calor de hidratación, fenómenos reológicos del hormigón y variaciones de temperaturas. Se han estudiado la evolución de las características mecánicas y de conductividad térmica del hormigón a lo largo del tiempo y especialmente a edades tempranas. Se han estudiado las evidencias experimentales disponibles y las estimaciones teóricas propuestas. Se han estudiado las recomendaciones de la CIRIA 660, que es el documento de referencia para tener en cuenta, desde el punto de vista del proyecto este tipo de fenómenos. Con el programa ATENA se han estudiado distintos ejemplos. El objetivo principal ha sido, por un lado, entender el fenómeno y, por otro, contrastar los criterios expuestos en la CIRA 660. This document studies the behavior of structural reinforced concrete structures subjected to imposed deformations, where the cracking occurs, mostly, in sections where the stresses, and thus cracks, due to the exterior actions are none-existent or practically zero. Early age cracking produced by the imposed deformations, due to heat of hydration and autogenous shrinkage, and long term effects, due to the drying shrinkage and the thermal variation, is studied. Available experimental results have been studied. A finite element program has been identified, ATENA, which allows the study of non-lineal phenomena, especially cracking. This software has been contrasted with the available experimental results. The imposed deformation sources have been studied for its characteristically sources: heat of hydration, concrete shrinkage and thermal variation. Also the evolution of the mechanical properties and the thermal conductivity of concrete in time and especially at early age have also been studied. The available experimental evidence and the proposal theoretical estimates have been studied. CIRIA 660 recommendations have been studied, which is the reference document to take into account, form the design point of view, this kind of phenomena. With the ATENA software different examples have been studied. On the one hand the main objective has been to understand the phenomena and, on the other, to contrast the CIRIA 660 proposal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las sondas eléctricas se emplean habitualmente en la diagnosis de plasmas. La presente tesis aborda la operación de las sondas colectoras y emisoras de Langmuir en plasmas fríos de baja densidad. El estudio se ha centrado en la determinación del potencial de plasma, Vsp, mediante el potencial flotante de una sonda emisora. Esta técnica consiste en la medida del potencial de la sonda correspondiente a la condición de corriente neta igual a cero, el cual se denomina potencial flotante, VF. Este potencial se desplaza hacia el potencial del plasma según aumenta la emisión termoiónica de la sonda, hasta que se satura cerca de Vsp. Los experimentos llevados a cabo en la pluma de plasma de un motor iónico y en un plasma de descarga de glow muestran que la corriente de electrones termoiónicos es mayor que la corriente de electrones recogidos para una sonda polarizada por debajo del potencial del plasma, resultado inconsistente con la teoría tradicionalmente aceptada. Para investigar estos resultados se ha introducido el parámetro R, definido como el cociente entre la corriente de electrones emitidos y recogidos por la sonda. Este parámetro, que está relacionado con la diferencia de potencial VF - Vsp, también es útil para la descripción de los modos de operación de la sonda emisora (débil, fuerte y más allá del fuerte). Los resultados experimentales evidencian que, al contrario de lo que indica la teoría, R es mayor que la unidad. Esta discrepancia se puede solucionar introduciendo una población efectiva de electrones. Con dicha población, el nuevo modelo para la corriente total de la sonda reproduce los datos experimentales. El origen de este grupo electrónico es todavía una cuestión abierta, pero podría estar originada por una nueva estructura de potencial cerca de la sonda cuando ésta trabaja en el régimen de emisión fuerte. Para explicar dicha estructura de potencial, se propone un modelo unidimensional compuesto por un mínimo de potencial cerca de la superficie de la sonda. El análisis numérico indica que este pozo de potencial aparece para muy altas temperaturas de la sonda, reduciendo la cantidad de electrones emitidos que alcanzan el plasma y evitando así cualquier posible perturbación de éste. Los aspectos experimentales involucrados en el método del potencial flotante también se han estudiado, incluyendo cuestiones como las diferentes técnicas de obtención del VF, el cociente señal-ruido, el acoplamiento de la señal de los equipos utilizados para la obtención de las curvas I-V o la evidencia experimental de los diferentes modos de operación de la sonda. Estas evidencias empíricas se encuentran en todos los aspectos de operación de la sonda: la recolección de electrones, el potencial flotante, la precisión en las curvas I-V y la emisión electrónica. Ésta última también se estudia en la tesis, debido a que un fenómeno de super emisión tiene lugar en el régimen de emisión fuerte. En este modo de operación, las medidas experimentales indican que las corrientes termoiónicas de electrones son mayores que aquéllas predichas por la ecuación de Richardson-Dushman clásica. Por último, la diagnosis de plasmas usando sondas eléctrica bajo presencia de granos de polvo (plasmas granulares) en plasmas fríos de baja densidad también se ha estudiado, mediante la aplicación numérica de la técnica del potencial flotante de la sonda emisora en un plasma no convencional. Los resultados apuntan a que el potencial flotante de una sonda emisora se vería afectado por altas densidades de polvo o grandes partículas. ABSTRACT Electric probes are widely employed for plasma diagnostics. This dissertation concerns the operation of collecting and emissive Langmuir probes in low density cold plasmas. The study is focused on the determination of the plasma potential, Vsp, by means of the floating potential of emissive probes. This technique consists of the measurement of the probe potential, corresponding to the zero net probe current, which is the so-called floating potential, VF . This potential displaces towards the plasma potential as the thermionic electron emission increases, until it saturates near Vsp. Experiments carried out in the plasma plume of an ion thruster and in a glow discharge plasma show the thermionic electron current of the emissive Langmuir probe is higher than the collected electron current, for a probe with a bias potential below Vsp, which is inconsistent with the traditional accepted theory. To investigate these results, a parameter R is introduced as the ratio between the emitted and the collected electron current. This parameter, which is related to the difference VF - Vsp, is also useful for the description of the operation modes of the emissive Langmuir probe (weak, strong and beyond strong). The experimental results give an inconsistency of R > 1, which is solved by a modification of the theory for emissive probes, with the introduction of an effective electron population. With this new electron group, the new model for the total probe current agrees with the experimental data. The origin of this electron group remains an open question, but it might be originated by a new potential structure near the emissive probe when it operates in the strong emission regime. A simple one-dimension model composed by a minimum of potential near the probe surface is discussed for strongly emitting emissive probes. The results indicate that this complex potential structure appears for very high probe temperatures and the potential well might reduce the emitted electrons population reaching the plasma bulk. The experimental issues involved in the floating potential method are also studied, as the different obtaining techniques of VF, the signal-to-noise ratio, the signal coupling of the I-V curve measurement system or the experimental evidence of the probe operation modes. These empirical proofs concern all the probe operation aspects: the electron collection, the floating potential, the I-V curve accuracy as well as the electron emission. This last issue is also investigated in this dissertation, because a super emission takes place in the strong emission regime. In this operation mode, the experimental results indicate that the thermionic electron currents might be higher than those predicted by the classical Richardson-Dushman equation. Finally, plasma diagnosis using electric probes in the presence of dust grains (dusty plasmas) in low density cold plasmas is also addressed. The application of the floating potential technique of the emissive probe in a non-conventional complex plasma is numerically investigated, whose results point out the floating potential of the emissive probe might be shifted for high dust density or large dust particles.