674 resultados para ELUTING STENTS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examined the longitudinal changes of VEGF levels after percutaneous coronary intervention for predicting major adverse cardiac events (MACE) in coronary artery disease (CAD) patients. VEGF was measured in 94 CAD patients' serum before revascularization, 1-month and 1-year after. Independently of clinical presentation, patients had lower VEGF concentration than a cohort of healthy subjects (median, IQ: 15.9, 9.0-264 pg/mL versus 419, 212-758 pg/mL; P < 0.001) at baseline. VEGF increased to 1-month (median, IQ: 276, 167-498 pg/mL; P < 0.001) and remained steady to 1-year (median, IQ: 320, 173-497 pg/mL; P < 0.001) approaching control levels. Drug eluting stent apposition and previous medication intake produced a less steep VEGF evolution after intervention (P < 0.05). Baseline VEGF concentration <40.8 pg/mL conveyed increased risk for MACE in a 5-year follow-up. Results reflect a positive role of VEGF in recovery and support its importance in CAD prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Morbid obesity is an epidemic and complex disease which imposes a multidisciplinary approach. Laparoscopic sleeve gastrectomy has become a frequent procedure given its effi- cacy and safety compared to other surgical options. However, it isn’t free from complications. Lax gastric fixation or incorrect positioning of the stomach during surgery can result in early gastric outlet obstruction caused by a volvulus-like mechanism by rotation of the stomach around its anatomic axes. This report refers to two cases of post sleeve gastric torsion resulting in persisting vomiting after initiating oral intake. The diagnosis was confirmed by upper gastrointestinal-contrast study and gastroscopy. In both cases, a fully covered self-expandable metallic stentwas insertedwhich prompted the gastric lumen to become permeable resulting in symptomatic resolution. The stents were removed endoscopically aftertwo and three months. Beyond more than three years offollow-up,the patients remain asymptomatic and no recurring ‘‘stenosis’’ was noticed.In these cases the use offully covered self-expandable metallic stents demonstrated to be effective and safe in the treatment of post sleeve gastric torsion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Descrevem-se dois casos de angioplastia transluminal coronária (ATC) com implante de stents em bifurcação de coronária descendente anterior (DA) com artéria diagonal (DI), destacando-se as técnicas utilizadas. No caso 1, implantou-se na DA um flexistent Gianturco-Roubin (GR) e através de suas hastes, um Palmaz-Schatz (PS) no óstio de DI, com sucesso. O reestudo angiográfico em sete meses mostrou ausência de reestenose. No caso 2, implantou-se metade de um stent PS em DA e outro PS em DI, nesta ordem, também com sucesso. No seguimento clínico de seis meses, paciente encontra-se assintomático.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar retrospectivamente, implante de stent (IS) em paciente com doença arterial coronária (DAC), realizado em 7 hospitais do Rio de Janeiro. MÉTODOS: De junho/94 a dezembro/96, foram realizados 2.220 procedimentos, e desses, analisados 783 IS em 660 (29,7%) pacientes, através da coronariografia sem subtração digital. Os diversos tipos de stent, mais freqüentemente, usados foram: Palmaz-Schatz (40,9%), Gianturco-Roubin (29,1%) e NIR (22,0%). As indicações para o IS foram: lesão de novo, 67,9%; lesão reestenótica, 16,0%; lesão com resultado subótimo da angioplastia transluminal coronária (ATC), 8,2%; oclusão aguda ou provável pós-ATC, 4,9%; oclusão crônica, 3,0%. Todos os stents foram implantados com alta pressão, sem controle pelo ultra-som intracoronário. A prevenção da trombose subaguda, na maioria dos pacientes (87,8%), foi feita com o uso de ticlopidina e ácido acetil-salicílico. RESULTADOS: Evolução imediata: a) sucesso no IS em 770 lesões: 98,0% em 646 (97,9%) pacientes; b) sucesso clínico em 634 (96,0%) casos; c) complicações maiores: infarto agudo do miocárdio (IAM) - 1,1%; cirurgia de revascularização miocárdica (CRM) - 1,4% e óbito - 0,8%; d) complicações vasculares com correção cirúrgica e/ou sangramento - 3,0%. Evolução tardia: a) dos 399 (60,4%) pacientes acompanhados clinicamente, a coronariografia de 121 (30,3%) mostrou retorno da lesão no IS em 79 (19,8%) casos; b) freqüência de outros eventos: IAM - 1,5%; CRM - 2,3%; óbito -1,0% e outra ATC ou procedimento similar - 12,5%. CONCLUSÃO: O estudo multicêntrico mostrou que o IS na DAC pode ser realizado com segurança, alto índice de sucesso imediato, poucas complicações e baixa taxa de eventos cardíacos na evolução tardia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mulher de 60 anos, com angina progressiva e revascularização do miocárdio, há oito anos, com ponte de veia safena para coronária direita e anastomose de artéria mamaria esquerda para artéria descendente anterior. Submetida a implante de stent Gianturco-Roubin II em terço proximal da ponte de veia safena para artéria coronária direita, com resultado insatisfatório pela persistência de lesão residual, provavelmente, decorrente de prolapso para dentro da luz de material aterosclerótico através dos coils. Foi implantado outro stent (Palmaz-Schatz biliar) dentro do stent GRII com sucesso e ótimo resultado angiográfico. Um 2º stent Palmaz-Schatz biliar foi implantado em lesão distal no corpo da ponte, ultrapassando os dois stents, anteriormente implantados, com sucesso. Em algumas situações, implante de stent dentro de outro stent é recurso útil para otimização de resultado angiográfico do implante de um stent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Relatar os resultados das intervenções coronárias percutâneas, no Brasil, no biênio 1996-97, comparando-os com os do biênio 1992-93. MÉTODOS: Foram coletados dados relativos a angioplastia com balão (ATC), aterectomia direcionada (AD), aterectomia rotacional (AR), angioplastia com laser (L) e stents coronários (ST). Estes dados foram comparados aos equivalentes, do Registro 1992-93. RESULTADOS: Participaram do registro atual 79% dos sócios titulares da SBHCI, de 127 hospitais, em 1996-97. Foram incluídos 22.025 pacientes, sendo 60,67% submetidos à ATC; 36,57% a ST; 2,3% a AR; 0,06% à AD e 0,4% ao L. A ATC foi o procedimento mais executado, observando-se um aumento relativo do implante de ST, de 1996 para 1997 de 35% (31,1 para 42,1%, p= 0,0001), com concomitante queda na utilização do balão (65,7% para 55,8%, p= 0,0001). A despeito da população de coronarianos tratados, em 1996-97 ser de maior complexidade clínica e anatômica, que a de 1992-93, verificaram-se maiores índices de sucesso do procedimento (89,7% x 92,8%, p= 0,000001), com menor lesão residual (22% x 19%, p= 0,001). Além disto, houve menores índices de complicações maiores: infarto agudo (2,5% x 1,2%, p<0,01), cirurgia de emergência (0,8% x 0,5%, p= 0,002) e óbito (1,8% x 1,4%, p= 0,0003). CONCLUSÃO: Os procedimentos mais executados no último biênio foram: o balão (60,67%) e os stents coronários (36,57%); verificam-se elevados índices de sucesso (92,3%) e baixas taxas de complicações maiores, confirmando o desempenho de excelência da Cardiologia Intervencionista brasileira.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ag and AgxO thin films were deposited by non-reactive and reactive pulsed DC magnetron sputtering, respectively, with the final propose of functionalizing the SS316L substrate with antibacterial properties. The coatings were characterized chemically, physically and structurally. The coatings nanostructure was assessed by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), while the coatings morphology was determined by scanning electron microscopy (SEM). The XRD and XPS analyses suggested that Ag thin film is composed by metallic Ag, which crystallizes in fcc-Ag phase, while the AgxO thin film showed both metallic Ag and Ag-O bonds, which crystalize in fcc-Ag and silver oxide phases. The SEM results revealed that Ag thin film formed a continuous layer, while AgxO layer was composed of islands with hundreds of nanometers surrounded by small nanoparticles with tens of nanometers. The surface wettability and surface tension parameters were determined by contact angle measurements, being found that Ag and AgxO surfaces showed very similar behavior, with all the surfaces showing a hydrophobic character. In order to verify the antibacterial behavior of the coatings, halo inhibition zone tests were realized for Staphylococcus epidermidis and Staphylococcus aureus. Ag coatings did not show antibacterial behavior, contrarily to AgxO coating, which presented antibacterial properties against the studied bacteria. The presence of silver oxide phase along with the development of different morphology were pointed as the main factors in the origin of the antibacterial effect found in AgxO thin film. The present study demonstrated that AgxO coating presented antibacterial behavior and its application in cardiovascular stents is promising.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The authors analyzed the 30-day and 6-month outcomes of 1,126 consecutive patients who underwent coronary stent implantation in 1996 and 1997. METHODS: The 30-day results and 6-month angiographic follow-up were analyzed in patients treated with coronary stents in 1996 and 1997. All patients underwent coronary stenting with high-pressure implantation (>12 atm) and antiplatelet drug regimen (aspirin plus ticlopidine). RESULTS: During the study period, 1,390 coronary stents were implanted in 1,200 vessels of 1,126 patients; 477 patients were treated in the year 1996 and 649 in 1997. The number of percutaneous procedures performed using stents increased significantly in 1997 compared to 1996 (64 % vs 48%, p=0.0001). The 30-day results were similar in both years; the success and stent thrombosis rates were equal (97% and 0.8%, respectively). The occurrence of new Q wave MI (1.3% vs 1.1%, 1996 vs 1997, p=NS), emergency coronary bypass surgery (1% vs 0.6%, 1996 vs 1997, p=NS) and 30-day death rates (0.2% vs 0.5%, 1996 vs 1997, p=NS) were similar. The 6-month restenosis rate was 25% in 1996 and 27% in 1997 (p= NS); the target vessel revascularization rate was 15% in 1996 and 16% in 1997 (p = NS). CONCLUSIONS: Intracoronary stenting showed a high success rate and a low incidence of 30-day occurrence of new major coronary events in both periods, despite the greater angiographic complexity of the patients treated with in 1997. These adverse variables did not have a negative influence at the 6-month clinical and angiographic follow-up, with similar rates of restenosis and ischemia-driven target lesion revascularization rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of in-stent restenosis. METHODS: Twenty-five patients with 33 incidents of in-stent restenosis treated with excimer laser coronary angioplasty (ELCA) were analyzed. Sixty-six percent were males, mean age of 73±11 years, and 83% were functional class III-IV (NYHA). ELCA was performed using 23 concentric and 10 eccentric catheters with a diameter of 1.6-2.2 mm, followed by balloon angioplasty (PTCA) and ultrasound monitoring. The procedure was performed in the following vessels: left anterior descending artery, 10; left circumflex artery, 8; right coronary artery, 6; left main coronary artery, 2; and venous bypass graft, 7. RESULTS: The ELCA was successful in 71% of the cases, and PTCA was 100% successful. The diameter of the treated vessels was 3.44±0.5mm; the minimal luminal diameter (MLD) increased from 0.30mm pre-ECLA to 1.97mm post-ELCA, and to 2.94mm post-PTCA (p<0.001). The percent stenosis was reduced from 91.4±9.5% before ECLA to 42.3±14.9% after ELCA and to 14.6 ± 9.3% after PTCA (p<0.001). Seventeen (68%) patients were asymptomatic at 6 months and 15 (60%) at 1 year. New restenosis rates were 8/33 (24.2%) at 6 months and 9 /33 (27.3%) at 12 months. CONCLUSION: ELCA is safe and effective for the treatment of in-stent restenosis. In the present sample, a slight increase in new restenotic lesions between 6 and 12 months was found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Comparative analysis of the in-hospital results after primary implantation of stents or coronary balloon angioplasty in patients with acute myocardial infarction (MI). METHODS: CENIC (National Center of Cardiovascular Interventions) gathered data on 3,924 patients undergoing coronary angioplasty (in the primary form, without the previous use of thrombolytic agents) in the first 24 hours after a MI, during the period of 1996-1998. From these 3,924 patients, 1,337 (34%) underwent stent implantation. We analyzed the success of the procedure and the occurrence of adverse cardiac events. RESULTS: In patients undergoing stent implantation there were more males (77% vs 69%, p=0.001), previous by pass surgery (6.3% vs. 4.5%, p=0.01), anterior MI and stent implantation in left descending artery (55% vs. 48% vs. p=0.009), and saphenous vein bypass grafts (3.3% vs. 1.9%). the procedure was more succesful in the group of stents (97% vs. 84%, p=0.001) and reinfarction rate (2.5 vs. 4%, p=0.002). The need for emergency revascularization was similar (1% vs. 1.1%, NS). Total in-hospital mortality was lower in stent group (3.4% vs. 7. 2%, p=0.0001) and this effect was in patients Killip class III/V (19.5% vs. 32.5%, p= 0.002) because there was no difference in patients class I/II (1.7% vs. 2.8%, p=0.9). CONCLUSION: Primary stent implantation in acute myocardial infarction showed better early results than balloon angioplasty alome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Analysis of the in-hospital results, in progressively elderly patients who undergo primary percutaneous coronary intervention (PCI) in the first 24 hours of AMI. METHODS: The patients were divided into three different age groups (60/69, 70/79, and > or = 80 years) and were treated from 7/95 until 12/99. The primary success rate and the occurrence of major clinical events were analyzed at the end of the in-hospital phase. Coronary stent implantation and abciximab use were employed at the intervencionist discretion. RESULTS: We analyzed 201 patients with age ranging from 60 to 93 years, who underwent primary PCI. Patients with ages above 70 were more often female (p=.015). Those with ages above 80 were treated later with PCI (p=.054), and all of them presented with total occlusion of the infarct-related artery. Coronary stents were implanted in 30% of the patients. Procedural success was lower in > or = 80 year old patients (p=.022), and the death rate was higher in > or = 70 years olds (p=.019). Reinfarction and coronary bypass surgery were uncommon events. A trend occurred toward a higher combined incidence of major in-hospital events according to increased age (p=.064). CONCLUSION: Elderly patients ( > or = 70 years) presented with adverse clinical and angiographic profiles and patients > or = 80 years of age obtained reduced TIMI 3 flow success rates after primary PTCA, and those > or = 70 years had a higher death rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the feasibility and safety of coronary interventions performed through the radial artery. METHODS: We studied 103 patients with ages from 38 to 86 years (57±8.7), 90 (87%) males, and: radial pulse with a good amplitude, presence of ulnar pulse, a good collateral flow through the palmar arch assessed with the Allen's test. RESULTS: The vascular approach was obtained in 97 (94%) patients, 88 (91%) treated electively and 9 (9%) during acute myocardial infarction, for primary angioplasty; 56 (64%) unstable angina; 22 (25%) stable angina; 10 (11%) were asymptomatic, 6 referred for recanalization of chronic occlusion and 4 silent ischemia in the first week after acute myocardial infarction. We approached 107 arteries: anterior descending artery, 49 (46%); right coronary artery, 27 (25%); circumflex artery, 25 (23%); diagonal artery, 6 (6%); and 2 saphenous vein bypass grafts. We treated 129 lesions: 80 (62%) B2 type; 23 (18%) B1 type; 17 (13%) C type; and 9 (7%). A type. There were 70 stents , and 59 balloon angioplasties performed. Thirty-two (33%) patients used GP IIb/IIIa inhibitors. The mean duration of the elective procedure was 42.3±12.8 min. Success, correct stent deployment and residual lesion <20%, was reached in 100% of the lesions treated with stent implantation; arterial dilation with residual lesion <50% was obtained in 96% of the lesions treated with transluminal coronary angioplasty (TCA). Complications, were: 1 (1.0%) non-Q-wave acute myocardial infarction; 2 (2%) hematomas in the forearm; and 2 losses of radial pulse. CONCLUSION: Radial artery aproach is practical and safe for percutaneous coronary interventions there was a low incidence of complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We conducted a comparative analysis of the in-hospital outcomes of patients who underwent primary percutaneous transluminal angioplasty (PTCA) or stent implantation because of an acute myocardial infarction (AMI) related to an acute vein graft occlusion. METHODS: Since 1991 the Brazilian Society of Hemodynamic and Interventional Cardiology has maintained a large database (CENIC). From these, we selected all consecutive patients, who underwent primary PTCA or stenting in the first 24 hours of AMI, with the target vessel being an occluded vein graft. Immediate results and major coronary events occurring up until hospital discharge were analyzed. RESULTS: During this period, 5,932 patients underwent primary PTCA or stenting; 158 (3%) of the procedures were performed because of an acute vein graft occlusion. Stenting was performed in 74 (47%) patients. Patients treated with stents had a higher success rate and lower mean residual stenosis compared with those who underwent primary balloon PTCA. The incidence of reinfarction and death were similar for stenting and balloon PTCA. CONCLUSION: Primary percutaneous treatment of AMI related to acute vein graft occlusion is still an uncommon practice. Primary stenting improved luminal diameter and offered higher rates of success; however, this strategy did not reduce the in-hospital reinfarction and death rate, compared with that occurring with PTCA treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.