669 resultados para ELECTROGENERATED CHEMILUMINESCENCE BIOSENSOR
Resumo:
Biosensors for determination of carbamates in vegetables based on five different cholinesterases as biorecognition elements and a screen-printed electrode system as an amperometric transducer were developed. Measurements were simply performed by dropping solutions (either sample or substrate) directly on the biosensor. The response of biosensors to selected carbamates (aldicarb, carbaryl, carbofuran, methomyl and propoxur) was characterized. The performance was evaluated on extracts of potatoes and carrots, the results from the AChE biosensor and a standard HPLC procedure were compared. Finally, the biosensor was used for the direct analysis of vegetable juices without any pretreatment steps. In this case, 10 mu g/L levels of added carbofuran and propoxur were reliably identified. The whole procedure takes less than 20 min including 10 min incubation with samples. The concentrations of carbamates determined with biosensor agreed well for carbofuran. Lower response was observed for propoxur.
Resumo:
Ferric and copper hexacyanoferrates (PB and CuHCF, respectively) were electrodeposited on glassy carbon electrodes providing a suitable catalytic surface for the amperometric detection of hydrogen peroxide. Additionally glucose oxidase was immobilized on top of these electrodes to form glucose biosensors. The biosensors were made by casting glucose oxidase-Nafion layers onto the surface of the modified electrodes. The operational stability of the films and the biosensors were evaluated by injecting a standard solution (5 mu M H2O2 for PB, 5 mM H2O2 for CuHCF and 1.5 mM glucose for both) over 5-10 h in a now-injection system with the electrodes polarized at - 50 (PB) and -200 mV (CuHCF) versus Ag/AgCl, respectively. The glucose biosensors demonstrated suitability for glucose determination: 0.0-2.5 mM (R-2 = 0.9977) for PB and 0.0-10 mM (R-2 = 0.9927) for CuHCF, respectively. The visualization of the redox catalyst modifiers (PB and CuHCF films) was presented by scanning electron micrographs. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
The generation of active chlorine on Ti/Sn(1-x)Ir (x) O-2 anodes, with different compositions of Ir (x = 0.01, 0.05, 0.10 and 0.30 ), was investigated by controlled current density electrolysis. Using a low concentration of chloride ions (0.05 mol L-1) and a low current density (5 mA cm(-2)) it was possible to produce up to 60 mg L-1 of active chlorine on a Ti/Sn0.99Ir0.01O2 anode. The feasibility of the discoloration of a textile acid azo dye, acid red 29 dye (C.I. 16570), was also investigated with in situ electrogenerated active chlorine on Ti/Sn(1-x)Ir (x) O-2 anodes. The best conditions for 100% discoloration and maximum degradation (70% TOC reduction) were found to be: NaCl pH 4, 25 mA cm(-2) and 6 h of electrolysis. It is suggested that active chlorine generation and/or powerful oxidants such as chlorine radicals and hydroxyl radicals are responsible for promoting faster dye degradation. Rate constants calculated from color decay versus time reveal a zero order reaction at dye concentrations up to 1.0 x 10(-4) mol L-1. Effects of other electrolytes, dye concentration and applied density currents also have been investigated and are discussed.
Resumo:
A label-free electrochemical detection method for DNA hybridization based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes is reported. Synthetic single-stranded 27-mer oligonucleotides (probe) have been immobilized at 2,5-bis(2-thienyl)-N-(3-phosphorylpropyl)pyrrole film formed by electropolymerization on the previously formed polypyrrole layer. The 27- or 18-mer target oligonucleotides were monitored via the electrochemically driven anion exchange of the inner polypyrrole film. The performance of the miniaturized DNA biosensor system was studied in respect to selectivity, sensitivity, reproducibility, and regeneration of the sensor. Control experiments were performed with a noncomplementary target of 27-mer DNA and 12 base-pair mismatched 18-mer sequences, respectively, and did not show any unspecific binding. Under optimized experimental conditions, the label-free electrochemical biosensor enabled the detection limits of 0.16 and 3.5 fmol for the 18- and 2 7-mer DNA strand, respectively. Furthermore, we demonstrate reusability of the electrochemical DNA biosensor after successful recovery of up to 100% of the original signal by regenerating the DNA label-free electrode with 50 mM HCl at room temperature.
Resumo:
dThe detection of aromatic compounds from pesticides and industrial wastewater has become of great interest, since these compounds withstand chemical oxidation and biological degradation, accumulating in the environment. In this work, a highly sensitive biosensor for detecting catechol was obtained with the immobilization of Cl-catechol 1,2-dioxygenase (CCD) in nanostructured films. CCD layers were alternated with poly(amidoamine) generation 4 (PAMAM G4) dendrimer using the electrostatic layer-by-layer (LbL) technique. Circular dichroism (CD) measurements indicated that the immobilized CCD preserved the same conformation as in solution. The thickness of the very first CCD layers in the LbL films was estimated at ca. 3.6 nm, as revealed by surface plasmon resonance (SPR). PAMAM/CCD 10-bilayer films were employed in detecting diluted catechol solutions using either an optical or electrical approach. Due to the mild immobilization conditions employed, especially regarding the pH and ionic strength of the dipping solutions, CCD remained active in the films for periods longer than 3 weeks. The optical detection comprised absorption experiments in which the formation of cis-cis muconic acid, resulting from the reaction between CCD and catechol, was monitored by measuring the absorbance at 260 nm after film immersion in catechol solutions. The electrical detection was carried out using LbL films deposited onto gold-interdigitated electrodes immersed in aqueous solutions at different catechol concentrations. Using impedance spectroscopy in a broad frequency range (1Hz-1kHz), we could detect catechol in solutions at concentrations as low as 10(-10) M. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Different procedures for obtaining a needle biosensor for the determination of glucose to be inserted subcutaneously in vivo, have been compared. Platinum wires with a diameter of 75 mum, teflon-coated were inserted in hypodermic needles and fixed with a two-component epoxy resin. Using a dip-coating procedure, several layers were deposited on electrodes. The first coating was cellulose acetate, the second was immobilized glucose oxidase (GOD) mixed with bovine serum albumin (BSA) and glutaraldheyde, the third coating was a polyurethane coating obtained with commercially available products. A large number of electrodes have been tried and statistically evaluated but they seem to be affected by poor reproducibility evidenced by a large spreading in successive calibration curves. Then, the polyurethane coating has been replaced by a thin polycarbonate membrane salinized and fixed on the tip of the needle. Reproducible results were achieved and first results of in vivo measurements on rabbits are reported.
Resumo:
An amperometric biosensor based on cholinesterase (ChE) has been used for the determination of selected carbamate insecticides in vegetable samples. The linear range of the biosensor for the N-methylcarbamates (aldicarb, carbaryl, carbofuran, methomyl and propoxur) varied from 5 x 10(-5) to 50 mg kg(-1). Limits of detection were calculated on the basis that the ChE enzymes were 10% inhibited and varied, depending of the combination ChE (as acetyl- or butyrylcholinesterase) vs. inhibitor (pesticide), from 1 x 10(-4) to 3.5 mg kg(-1). The biosensor-based carbamate determination was compared to liquid chromatography/UV methods. Three vegetable samples were spiked with carbofuran and propoxur at 125 mu g kg(-1) followed by conventional procedures. Good correlations were observed for carbofuran in the vegetable extracts (79, 96 and 91% recoveries for potato, carrot and sweet pepper, respectively), whereas for propoxur unsatisfactory results were obtained. Potato and carrot samples were spiked with 10, 50 and 125 mu g kg(-1) carbofuran, followed by direct determination by the amperometric biosensor. The fortified sampler; resulted in very high inhibition values, and recoveries were: 28, 34 and 99% for potato, and 140, 90 and 101% for carrot, respectively, at these three fortification levels. (C) 1998 Elsevier B.V. B.V.
Resumo:
This paper reports the surface activity of phytase at the air-water interface, its interaction with lipid monolayers, and the construction of a new phytic acid biosensor on the basis of the Langmuir-Blodgett (LB) technique. Phytase was inserted in the subphase solution of dipalmitoylphosphatidylglycerol (DPPG) Langmuir monolayers, and its incorporation to the air-water interface was monitored with surface pressure measurements. Phytase was able to incorporate into DPPG monolayers even at high surface pressures, ca. 30 mN/m, under controlled ionic strength, pH, and temperature. Mixed Langmuir monolayers of phytase and DPPG were characterized by surface pressure-area and surface potential-area isotherms, and the presence of the enzyme provided an expansion in the monolayers ( when compared to the pure lipid at the interface). The enzyme incorporation also led to significant changes in the equilibrium surface compressibility (in-plane elasticity), especially in liquid-expanded and liquid-condensed regions. The dynamic surface elasticity for phytase-containing interfaces was investigated using harmonic oscillation and axisymmetric drop shape analysis. The insertion of the enzyme at DPPG monolayers caused an increase in the dynamic surface elasticity at 30 mN m(-1), indicating a strong interaction between the enzyme and lipid molecules at a high-surface packing. Langmuir-Blodgett (LB) films containing 35 layers of mixed phytase-DPPG were characterized by ultraviolet-visible and fluorescence spectroscopy and crystal quartz microbalance nanogravimetry. The ability in detecting phytic acid was studied with voltammetric measurements.
Resumo:
The aim of the present work was to compare colonic mucosa and plasmatic oxidative stress measured concomitantly and with different degrees of injury in rats with colitis induced by trinitrobenzene sulfonic acid. Three groups were studied: control group, colitis group, and colitis exacerbated by diclofenac. Enzymatic markers of colon injury showed enhanced activity in both groups with colitis. The colitis group treated with diclofenac presented higher colonic damage score than the other groups. In both groups with colitis, higher values of tert butyl hydroperoxide-initiated-chemiluminescence and thiobarbituric acid-reactive substances in tissue and decreased total radical-trapping antioxidant potential (TRAP) levels in plasma were found. In conclusion, independently of the degree of colonic mucosa injury and inflammation, oxidative stress in tissue occurs as a consequence of pro-oxidants increase, and is not explained by a reduction of antioxidant defenses. In both conditions, TRAP determination decreases in plasma, but not in tissue.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The scientific question addressed in this work is: what hides beneath first order kinetic constant k (s(-1)) measured for hybridization of a DNA target on a biosensor surface. Kinetics hybridization curves were established with a 27 MHz quartz microbalance (9 MHz, third harmonic) biosensor, constituted of a 20-base probe monolayer deposited on a gold covered quartz surface. Kinetics analysis, by a known two-step adsorption-hybridization mechanism, is well appropriate to fit properly hybridization kinetics curves, for complementary 20-base to 40-base targets over two concentration decades. It was found that the K-1 (M-1) adsorption constant, relevant to the first step, concerns an equilibrium between non hybridized targets and hybridized pre-complex and increases with DNA target length. It was established that k(2) (s(-1)), relevant to irreversible formation of a stable duplex, varies in an opposite way to K-1 with DNA target length. (C) 2012 Published by Elsevier B.V.
Resumo:
The enzyme horseradish peroxidase HRP (EC:1.11.1.7), has both acid and basic isoenzymes, catalyses a wide range of reactions (acting as an oxiredutase or an oxidase) and is thought capable of one- or two-electrons oxidations depending on the substrate employed. Today, the methodology for these assay can be chemiluminescent reactions and enhanced chemiluminescent. The enhanced chemiluminescent assay with system HRP, luminol, peroxide and an enhancer has provided the basis for a convenient and sensitive assay for peroxidase and peroxidase conjugates, DNA probe and blotting assay. It is particularly more advantageous than the others, because is very rapid, more sensitive (attomoles), easy to do and technically simple, and is relatively specific for HRP (reduces the effect of the interference).
Resumo:
The history, the chemistry and the physic aspects of luminescence phenomenon are approached, essentially in relation to chemiluminescence, chemical reactions which emit light, discussing about its importance, definition, classification and application.
Resumo:
Chemically modified electrodes based on hexacyanometalate films are presented as a tool in analytical chemistry. Use of amperometric sensors and/or biosensors based on the metal-hexacyanoferrate films is a tendency. This article reviews some applications of these films for analytical determination of both inorganic (e.g. As3+, S2O3 2-) and organic (e.g. cysteine, hydrazine, ascorbic acid, gluthatione, glucose, etc.) compounds.
Resumo:
Proteins containing the classical nuclear localization sequences (NLSs) are imported into the nucleus by the importin-α/β heterodimer. Importin-α contains the NLS binding site, whereas importin-β mediates the translocation through the nuclear pore. We characterized the interactions involving importin-α during nuclear import using a combination of biophysical techniques (biosensor, crystallography, sedimentation equilibrium, electrophoresis, and circular dichroism). Importin-α is shown to exist in a monomeric autoinhibited state (association with NLSs undetectable by biosensor). Association with importin-β (stoichiometry, 1:1; K D = 1.1 × 10 -8 M) increases the affinity for NLSs; the importin-α/β complex binds representative monopartite NLS (simian virus 40 large T-antigen) and bipartite NLS (nucleoplasmin) with affinities (K D = 3.5 × 10 -8 M and 4.8 × 10 -8 M, respectively) comparable with those of a truncated importin-α lacking the autoinhibitory domain (T-antigen NLS, K D = 1.7 × 10 -8 M; nucleoplasmin NLS, K D = 1.4 × 10 -8 M). The autoinhibitory domain (as a separate peptide) binds the truncated importin-α, and the crystal structure of the complex resembles the structure of full-length importin-α. Our results support the model of regulation of nuclear import mediated by the intrasteric autoregulatory sequence of importin-α and provide a quantitative description of the binding and regulatory steps during nuclear import.