998 resultados para Cs complexation method
Resumo:
A comparison of the Etest and the reference broth macrodilution susceptibility test for fluconazole, ketoconazole, itraconazole and amphotericin B was performed with 59 of Candida species isolated from the oral cavities of AIDS patients. The Etest method was performed according to the manufacturer's instructions, and the reference method was performed according to National Committee for Clinical Laboratory Standards document M27-A guidelines. Our data showed that there was a good correlation between the MICs obtained by the Etest and broth dilution methods. When only the MIC results at ± 2 dilutions for both methods were considered, the agreement rates were 90.4% for itraconazole, ketoconazole and amphotericin B and 84.6% for fluconazole of the C. albicans tested. In contrast, to the reference method, the Etest method classified as susceptible three fluconazole-resistant isolates and one itraconazole-resistant isolate, representing four very major errors. These results indicate that Etest could be considered useful for antifungal sensitivity evaluation of yeasts in clinical laboratories.
Resumo:
O crescimento populacional esperado para os próximos anos conduzirá à necessidade de aumentar a produção agrícola de modo a satisfazer o aumento da procura. Nos últimos anos tem-se assistido a uma evolução tecnológica nos sistemas de produção que tem permitido aumentar a produtividade agrícola, por vezes à custa de elevados consumos de energia e com práticas nem sempre ambientalmente corretas. Os desafios que se colocam atualmente são no sentido de melhorar a conservação de recursos escassos, como o solo e a água, de aumentar a eficiência de uso de fatores de produção, de encontrar novas culturas, do desenvolvimento da biotecnologia, da diminuição dos consumos energéticos e de melhorar ainda mais as tecnologias associadas à produção. De maneira a responder aos desafios emergentes da procura por alimentos, da escassez de terrenos agrícolas aráveis bem como da existência de pragas de insetos e de ervas daninhas, os pesticidas tem vindo a ser usados com maior frequência, tendo-se assistido a uma contaminação dos solos e águas subterrâneas, causando deste modo um risco para a saúde dos seres vivos. Neste sentido, vários fabricantes de pesticidas estão a desenvolver novas formulações contendo pesticidas encapsulados em nanopartículas como modo de aumentar a sua solubilidade em água, biodisponibilidade, volatilidade, estabilidade e eficácia. tendo por objetivo um desenvolvimento sustentável. Neste trabalho, procedeu-se ao estudo do encapsulamento do herbicida Oxadiargil (5-terc-butil-3-[2,4-dicloro-5-(2-propiniloxi)fenil]-1,3,4-oxadiazol-2(3H)-ona) com a 2-hidroxipropil-β-ciclodextrina (HP-β-CD). O estudo da formação do complexo de inclusão Oxadiargil - HP-β-CD foi realizado em diferentes meios, água desionizada, tampão acetato pH = 3,46 e pH = 5,34 e tampão fosfato pH = 7,45, com o objetivo de determinar e comparar a sua constante de estabilidade. Verificou-se, em qualquer dos casos, a ocorrência de uma relação linear entre o aumento da solubilidade do Oxadiargil e o aumento da concentração de HP-β-CD, com um declive inferior a um, o que indicia a formação de um complexo na proporção estequiométrica de 1:1. Os resultados obtidos permitiram concluir que o processo de complexação Oxadiargil - HP-β-CD não é muito influenciado pela constituição e pelo pH do meio. De facto, as constantes de estabilidade obtidas para a água desionizada e soluções-tampão pH = 3,46, pH = 5,34 e pH = 7,45 foram de 919 ± 25, 685 ± 13, 623 ± 17 e 753 ± 9, respetivamente. A solubilidade do complexo obtido nos estudos realizados, em diferentes meios, é cerca de 23 a 32 vezes superior à observada para o Oxadiargil livre. De forma a caracterizar o complexo Oxadiargil - HP-β-CD procedeu-se à sua síntese utilizando o método de “kneading”. O composto obtido foi caracterizado por Ressonância Magnética Nuclear (RMN) tendo-se confirmado a formação de um complexo de inclusão na proporção estequiométrica de 1:1. O complexo obtido é mais solúvel e porventura mais estável quimicamente. O encapsulamento permite uma redução da aplicação dos pesticidas diminuindo assim os custos e o impacto negativo no ambiente. Com a nanotecnologia é possível a libertação controlada dos pesticidas, aumentando a sua eficácia e fornecendo os meios necessários para um desenvolvimento sustentável.
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.
Resumo:
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.
Resumo:
The local fractional Poisson equations in two independent variables that appear in mathematical physics involving the local fractional derivatives are investigated in this paper. The approximate solutions with the nondifferentiable functions are obtained by using the local fractional variational iteration method.
Resumo:
Cryptococcus neoformans detection was optimized using PCR technique with the objective of application in the clinical laboratory diagnosis. The amplification area was ITS and 5,6S which encodes the ribosomal RNA (rRNA). A total of 72 cerebrospinal fluid (CSF) samples were used, obtained from cases with and without AIDS. The patients had cryptococcal meningitis (n = 56) and meningitis caused by other agents (n = 16). The results demonstrated that PCR test had the highest sensitivity rates, superior to culture (85.7%) and to India ink test (76.8%). PCR was found to be sensitive in detecting 1 cell/mL and highly specific since it did not amplify other fungal DNA. The comparative analysis of the methods showed that PCR is more sensitive and specific and is applicable as an important laboratorial resource for neurocryptococcosis diagnosis.
Resumo:
The pathogenesis of the renal lesion upon envenomation by snakebite has been related to myolysis, hemolysis, hypotension and/or direct venom nephrotoxicity caused by the venom. Both primary and continuous cell culture systems provide an in vitro alternative for quantitative evaluation of the toxicity of snake venoms. Crude Crotalus vegrandis venom was fractionated by molecular exclusion chromatography. The toxicity of C. vegrandis crude venom, hemorrhagic, and neurotoxic fractions were evaluated on mouse primary renal cells and a continuous cell line of Vero cells maintained in vitro. Cells were isolated from murine renal cortex and were grown in 96 well plates with Dulbecco's Modified Essential Medium (DMEM) and challenged with crude and venom fractions. The murine renal cortex cells exhibited epithelial morphology and the majority showed smooth muscle actin determined by immune-staining. The cytotoxicity was evaluated by the tetrazolium colorimetric method. Cell viability was less for crude venom, followed by the hemorrhagic and neurotoxic fractions with a CT50 of 4.93, 18.41 and 50.22 µg/mL, respectively. The Vero cell cultures seemed to be more sensitive with a CT50 of 2.9 and 1.4 µg/mL for crude venom and the hemorrhagic peak, respectively. The results of this study show the potential of using cell culture system to evaluate venom toxicity.
Resumo:
OBJECTIVE: Venous aneurysms of the lower limbs are rare. When they involve the deep venous system, they can be associated with deep venous thrombosis and pulmonary embolism. The authors report the case of a 63-year-old women evaluated by duplex imaging and venography, in the context of a pulmonary embolism, and detected bilateral large aneurysms of the femoral veins (5 cm in the right femoral vein and 4 cm in the left femoral vein). The aneurysms were located at the bifurcation of the common femoral vein with the superficial and profound veins. METHOD: The right aneurysm was partially thrombosed. The patient was asymptomatic in the lower-limb extremities. After a period of anticoagulation, the authors proceeded to surgically excise the right aneurysm and replaced the venous system using a polytetrafluoroethylene (PTFE) graft with the construction of an a-v fistula. RESULT: The patient had no complications in the postoperative period and her 8-month follow-up examination revealed no symptoms, not even leg edema. The duplex scan showed patency of the graft. She continued with oral anticoagulation. The histologic examination revealed an eosinophilic inflammatory reaction of the vein wall, compatible with the diagnosis of Churg-Strauss syndrome. CONCLUSION: The authors conclude that they have probably described the first case in the international literature of a venous aneurysm with a Churg-Strauss syndrome and pulmonary embolism.
Resumo:
This work presents an automatic calibration method for a vision based external underwater ground-truth positioning system. These systems are a relevant tool in benchmarking and assessing the quality of research in underwater robotics applications. A stereo vision system can in suitable environments such as test tanks or in clear water conditions provide accurate position with low cost and flexible operation. In this work we present a two step extrinsic camera parameter calibration procedure in order to reduce the setup time and provide accurate results. The proposed method uses a planar homography decomposition in order to determine the relative camera poses and the determination of vanishing points of detected lines in the image to obtain the global pose of the stereo rig in the reference frame. This method was applied to our external vision based ground-truth at the INESC TEC/Robotics test tank. Results are presented in comparison with an precise calibration performed using points obtained from an accurate 3D LIDAR modelling of the environment.
Resumo:
Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.
Resumo:
An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.
Resumo:
In this study a citrate-buffered version of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method for determination of 14 organochlorine pesticides (OCPs) residues in tamarind peel, fruit and commercial pulp was optimized using gas chromatography (GC) coupled with electron-capture detector (ECD) and confirmation by GC tandem mass spectrometry (GC–MS/MS). Five procedures were tested based on the original QuEChERS method. The best one was achieved with increased time in ultrasonic bath. For the extract clean-up, primary secondary amine (PSA), octadecyl-bonded silica (C18) and magnesium sulphate (MgSO4) were used as sorbents for tamarind fruit and commercial pulp and for peel was also added graphitized carbon black (GCB). The samples mass was optimized according to the best recoveries (1.0 g for peel and fruit; 0.5 g for pulp). The method results showed the matrix-matched calibration curve linearity was r2 > 0.99 for all target analytes in all samples. The overall average recoveries (spiked at 20, 40 and 60 μg kg−1) have been considered satisfactory presenting values between 70 and 115% with RSD of 2–15 % (n = 3) for all analytes, with the exception of HCB (in peel sample). The ranges of limits of detection (LOD) and quantification (LOQ) for OCPs were for peel (LOD: 8.0–21 μg kg−1; LOQ: 27–98 μg kg−1); for fruit (LOD: 4–10 μg kg−1; LOQ: 15–49 μg kg−1) and for commercial pulp (LOD: 2–5 μg kg−1; LOQ: 7–27 μg kg−1). The method was successfully applied in tamarind samples being considered a rapid, sensitive and reliable procedure.