997 resultados para Continuum removal technique
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2013
Resumo:
Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2015
Resumo:
To study changes in survival, in biological activities and behavior of planorbids submitted to increased hydrostatic pressure, we developed a technique using two transparent chambers and a hydraulic piston. The apparatus permitted renewal of the liquid medium without substantial variations in pressure, thus eliminating excretion products and maintaining the desired O2 level and thereby permitting us to evaluate the effects of pressure independently of the occurrence of anoxia. Pressure was maintained without any contact of the liquid medium with compressed air, a situation which reproduced with relative fidelity what occurs in nature and assured the presence of the same amounts of gases in the two observation chambers (Control and Experimental). Biomphalaria glabrata was found to be able to survive at least 48 hours when submitted to 49.02 x 10**4 Pa (equivalent to a water depth of 48.8 m), continuing to day egg masses and showing few behavioral changes when compared with the control group.
Resumo:
SUMMARY: Coil displacement during endovascular coiling procedures may require coil retrieval in the context of flow limitation or thromboembolic risk. No standard recommended method of coil retrieval exists. We present a consecutive series of 14 patients with displaced coil during aneurysm coiling in whom the complication was effectively managed with the use of a stent retriever system. Two illustrative cases from the 14 are described, and technical notes are detailed regarding use of the technique. The use of stent retrievers presents a simple, safe, and effective choice for removal of prolapsed coils during aneurysm coiling.
Resumo:
Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.
Resumo:
A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.
Resumo:
In this paper, we consider an exchange economy µa la Shitovitz (1973), with atoms and an atomless set. We associate with it a strategic market game of the kind first proposed by Lloyd S. Shapley and known as the Shapley window model. We analyze the relationship between the set of the Cournot-Nash equilibrium allocations of the strategic market game and the Walras equilibrium allocations of the exchange economy with which it is associated. We show, with an example, that even when atoms are countably in¯nite, any Cournot-Nash equilibrium allocation of the game is not a Walras equilibrium of the underlying exchange economy. Accordingly, in the original spirit of Cournot (1838), we par- tially replicate the mixed exchange economy by increasing the number of atoms, without a®ecting the atomless part, and ensuring that the measure space of agents remains finite. We show that any sequence of Cournot-Nash equilibrium allocations of the strategic market games associated with the partially replicated exchange economies approximates a Walras equilibrium allocation of the original exchange economy.
Resumo:
BACKGROUND AND OBJECTIVE: Standardization of surgical technique helps to reproduce excellent clinical outcomes, especially in teaching institutions. We aim to describe in detail our established approach for oncological right colectomy. TECHNIQUE: The right colon is mobilized in a five-step latero-inferior approach starting off with (1) the terminal ileum, visualizing the duodenum and the head of pancreas. (2) The ascending colon is dissected from the retroperitoneum, and takedown of the hepatic flexure is completed coming retrograde from the transverse colon (3). (4) Transection of the remaining retroperitoneal attachments completes exposure of the duodenum and mobilization of the right colon. (5) Ileocolic vessels are dissected out and divided close to their origin, and the mesocolon is divided. We then establish intestinal continuity by use of a side-to-side stapled technique. (1) The arms of a linear cutting stapler are inserted via transverse incisions at the anti-mesenteric sides of the terminal ileum and the transverse colon (tenia) and fired. (2) The enterotomy site is closed by removal of the specimen using a second transverse firing of the linear cutting stapler. An important final step is the (3) reinforcement of the anastomotic ends and the crossing of the staple lines; an omental patch and closure of the mesenteric window are optional. CONCLUSION: The suggested standardized five-step lateral-to-medial dissection of the right colon and the three-step side-to-side stapled technique for ileo-colonic anastomosis are easy to learn and to reproduce. Careful adherence to pivotal technical details will help to obtain an optimal oncological outcome and a consistently low leak rate around 2 %.
Resumo:
Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.
Resumo:
A consecutive series of 353 patients who underwent Lichtenstein mesh repair for inguinal hernia from the 1st of July 1994 to the 30th of July 1995 were studied. We analysed our indication, technique, complications, follow-up and outcome. Special consideration was given to the advantages and acceptance of day-case surgery. Our results suggest that the Lichtenstein repair should be considered as a new standard procedure, especially outside of hernia centres.
Resumo:
Passage of malaria infected blood through a two-layered column composed of acid-washed glass beads and CF 11 cellulose removes white cells from parasitized blood. However, because use of glass beads and CF 11 cellulose requires filtration of infected blood separately through these two resins and the addition of ADP, the procedure is time-consuming and may be inapropriate for use in the field, especially when large numbers of blood samples are to be treated. Our modification of this process yields parasitized cells free of contaminating leukocytes, and because of its operational simplicity, large numbers of blood samples can be processed. Our procedure also compares well with those using expensive commercial Sepacell resins in its ability to separate leukocytes from whole blood. As a test of usefulness in molecular biologic investigations, the parasites obtained from the blood of malaria-infected patients using the modified procedure yield genomic DNA whose single copy gene, the circumsporozite gene, efficiently amplifies by polymerase chain reaction.