926 resultados para Compact Dual Frequency rnicrostrip antennas


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have demonstrated a switchable dual wavelength fiber ring laser with a high degree of polarization output by using an intracavity 3-stage all fiber Lyot filter. The filter is formed by concatenating four 45° tilted fiber gratings separated by polarization maintaining fibers with a length ratio of 1:2:4 (20, 40, and 80 cm), giving a compact integrated configuration with reduced bandwidth. Switchable dual wavelength or single wavelength output at 1533.5 and 1563.3 nm has been achieved. The output lasing is considerably stable owing to the in-phase mode-selecting function of the multistage Lyot filter, and has a very high degree of polarization higher than 99.9%. © 1989-2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For the development of communication systems such as Internet of Things, integrating communication with power supplies is an attractive solution to reduce supply cost. This paper presents a novel method of power/signal dual modulation (PSDM), by which signal transmission is integrated with power conversion. This method takes advantage of the intrinsic ripple initiated in switch mode power supplies as signal carriers, by which cost-effective communications can be realized. The principles of PSDM are discussed, and two basic dual modulation methods (specifically PWM/FSK and PWM/PSK) are concluded. The key points of designing a PWM/FSK system, including topology selection, carrier shape, and carrier frequency, are discussed to provide theoretical guidelines. A practical signal modulation-demodulation method is given, and a prototype system provides experimental results to verify the effectiveness of the proposed solution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

∗ Supported by Research grants GAUK 190/96 and GAUK 1/1998

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An approach to realizing simultaneous measurement of refractive index (RI) and temperature based on a microfiber-based dual inline Mach-Zehnder interferometer (MZI) is proposed and demonstrated. Due to different interference mechanisms, as one interference between the core mode and the lower order cladding mode in the sensing single-mode fiber and the other interference between the fundamental mode and the high-order mode in the multimode microfiber, the former interferometer achieves RI sensitivity of -23.67 nm/RIU and temperature sensitivity of 81.2 pm/oC, whereas those of the latter are 3820.23 nm/RIU, and -465.7 pm/oC, respectively. The large sensitivity differences can provide a more accurate demodulation of RI and temperature. The sensor is featured with multiparameters measurement, compact structure, high sensitivity, low cost, and easy fabrication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For the first time we demonstrate simultaneous suppression of phase distortion on two independent 10.7 Gbit/s DPSK modulated signal wavelengths using semiconductor optical amplifiers, realizing a compact phase sensitive amplifier with low power consumption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A compact and low cost fiber sensor based on microfiber with Fresnel reflection is proposed and demonstrated for simultaneous measurement of refractive index (RI) and temperature with high sensitivities. © OSA 2015.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The innovation of optical frequency combs (OFCs) generated in passive mode-locked lasers has provided astronomy with unprecedented accuracy for wavelength calibration in high-resolution spectroscopy in research areas such as the discovery of exoplanets or the measurement of fundamental constants. The unique properties of OCFs, namely a highly dense spectrum of uniformly spaced emission lines of nearly equal intensity over the nominal wavelength range, is not only beneficial for high-resolution spectroscopy. Also in the low- to medium-resolution domain, the OFCs hold the promise to revolutionise the calibration techniques. Here, we present a novel method for generation of OFCs. As opposed to the mode-locked laser-based approach that can be complex, costly, and difficult to stabilise, we propose an all optical fibre-based system that is simple, compact, stable, and low-cost. Our system consists of three optical fibres where the first one is a conventional single-mode fibre, the second one is an erbium-doped fibre and the third one is a highly nonlinear low-dispersion fibre. The system is pumped by two equally intense continuous-wave (CW) lasers. To be able to control the quality and the bandwidth of the OFCs, it is crucial to understand how optical solitons arise out of the initial modulated CW field in the first fibre. Here, we numerically investigate the pulse evolution in the first fibre using the technique of the solitons radiation beat analysis. Having applied this technique, we realised that formation of higherorder solitons is supported in the low-energy region, whereas, in the high-energy region, Kuznetsov-Ma solitons appear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose and demonstrate a microfiber Fabry-Perot interferometer (MFPI) fabricated by taper-drawing microfiber at the center of a uniform fiber Bragg grating (FBG). The MFPI employing the two separated sections of FBG as reflectors and a length of microfiber as its cavity is derived. Theoretic study shows that the reflection spectrum of such MFPI is consisted of two parts-interference fringes induced by multi-beam interference and reflection spectrum envelope induced by FBGs. Temperature affects both interference fringes and reflection wavelength of FBGs while ambient refractive index (RI) only influences the interference fringes, i.e., MFPI has different response to temperature and RI. Therefore, MFPI for simultaneous sensing of RI and temperature is experimentally demonstrated by tracking a reflection peak of interference fringes and the Bragg wavelength of the FBGs, which are respectively assisted by frequency domain processing and Gaussian fitting of the optical spectrum. Consequently, wavelength measurement resolution of 0.5 pm is realized. © 1983-2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

By tracing the beat frequency between two polarization modes generated from a DBR fiber laser, a novel human pulse monitoring device is demonstrated. The results show the device could be very useful for healthcare. © 2013 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Compact and tunable semiconductor terahertz sources providing direct electrical control, efficient operation at room temperatures and device integration opportunities are of great interest at the present time. One of the most well-established techniques for terahertz generation utilises photoconductive antennas driven by ultrafast pulsed or dual wavelength continuous wave laser systems, though some limitations, such as confined optical wavelength pumping range and thermal breakdown, still exist. The use of quantum dot-based semiconductor materials, having unique carrier dynamics and material properties, can help to overcome limitations and enable efficient optical-to-terahertz signal conversion at room temperatures. Here we discuss the construction of novel and versatile terahertz transceiver systems based on quantum dot semiconductor devices. Configurable, energy-dependent optical and electronic characteristics of quantum-dot-based semiconductors are described, and the resonant response to optical pump wavelength is revealed. Terahertz signal generation and detection at energies that resonantly excite only the implanted quantum dots opens the potential for using compact quantum dot-based semiconductor lasers as pump sources. Proof-of-concept experiments are demonstrated here that show quantum dot-based samples to have higher optical pump damage thresholds and reduced carrier lifetime with increasing pump power.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluorescence-enhanced optical imaging is an emerging non-invasive and non-ionizing modality towards breast cancer diagnosis. Various optical imaging systems are currently available, although most of them are limited by bulky instrumentation, or their inability to flexibly image different tissue volumes and shapes. Hand-held based optical imaging systems are a recent development for its improved portability, but are currently limited only to surface mapping. Herein, a novel optical imager, consisting primarily of a hand-held probe and a gain-modulated intensified charge coupled device (ICCD) detector, is developed towards both surface and tomographic breast imaging. The unique features of this hand-held probe based optical imager are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) reduce overall imaging time using a unique measurement geometry, and (iii) perform tomographic imaging for tumor three-dimensional (3-D) localization. Frequency-domain based experimental phantom studies have been performed on slab geometries (650 ml) under different target depths (1-2.5 cm), target volumes (0.45, 0.23 and 0.10 cc), fluorescence absorption contrast ratios (1:0, 1000:1 to 5:1), and number of targets (up to 3), using Indocyanine Green (ICG) as fluorescence contrast agents. An approximate extended Kalman filter based inverse algorithm has been adapted towards 3-D tomographic reconstructions. Single fluorescence target(s) was reconstructed when located: (i) up to 2.5 cm deep (at 1:0 contrast ratio) and 1.5 cm deep (up to 10:1 contrast ratio) for 0.45 cc-target; and (ii) 1.5 cm deep for target as small as 0.10 cc at 1:0 contrast ratio. In the case of multiple targets, two targets as close as 0.7 cm were tomographically resolved when located 1.5 cm deep. It was observed that performing multi-projection (here dual) based tomographic imaging using a priori target information from surface images, improved the target depth recovery over using single projection based imaging. From a total of 98 experimental phantom studies, the sensitivity and specificity of the imager was estimated as 81-86% and 43-50%, respectively. With 3-D tomographic imaging successfully demonstrated for the first time using a hand-held based optical imager, the clinical translation of this technology is promising upon further experimental validation from in-vitro and in-vivo studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a study of the integration of filters and microstrip antennas, yielding devices named as filtennas for applications in wireless communications systems. The design of these structures is given from the observation of filtennas based integration between horn antennas and frequency selective surfaces (FSS), used in the band X. The choice of microstrip line structures for the development of a new configuration filtennas justifies the wide application of these transmission lines, in recent decades, always resulting in the production of circuit structures with planar light-weight, compact size, low cost, easy to construct and particularly easy to integrate with other microwave circuits. In addition, the antenna structure considered for the composition of filtennas consists of a planar monopole microstrip to microstrip filters integrated in the feed line of the antenna. In particular, are considered elliptical monopole microstrip (operating in UWB UWB) microstrip filters and (in structures with associated sections in series and / or coupled). In addition, the monopole microstrip has a proper bandwidth and omnidirectional radiation pattern, such that its integration with microstrip filters results in decreased bandwidth, but with slight changes in the radiation pattern. The methods used in the analysis of monopoles, and filters were filtennas finite elements and moments by using commercial software Ansoft Designer and HFSS Ansoft, respectively. Specifically, we analyze the main characteristics of filtennas, such as radiation pattern, gain and bandwidth. Were designed, constructed and measures, several structures filtennas, for validation of the simulated results. Were also used computational tools (CAD) in the process of building prototypes of planar monopoles, filters and filtennas. The prototypes were constructed on substrates of glass-fiber (FR4). Measurements were performed at the Laboratory for Telecommunications UFRN. Comparisons were made between simulated and measured, and found good agreement in the cases considered

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Synchronous machines, widely used in energy generation systems, require constant voltage and frequency to obtain good quality of energy. However, for large load variati- ons, it is difficult to maintain outputs on nominal values due to parametric uncertainties, nonlinearities and coupling among variables. Then, we propose to apply the Dual Mode Adaptive Robust Controller (DMARC) in the field flux control loop, replacing the tradi- tional PI controller. The DMARC links a Model Reference Adaptive Controller (MRAC) and a Variable Structure Model Reference Adaptive Controller (VS-MRAC), incorpora- ting transient performance advantages from VS-MRAC and steady state properties from MRAC. Moreover, simulation results are included to corroborate the theoretical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A compact and low cost fiber sensor based on single multimode microfiber with Fresnel reflection is proposed and demonstrated for simultaneous measurement of refractive index and temperature. The sensor is fabricated with two simple steps including fiber tapering and then fiber endface cleaving. The reflection spectrum is an intensity modulated interference spectrum, as the tapered fiber generates interference pattern and the cleaved endface provides intensity modulation. By demodulating the fringe power and free spectrum range (FSR) of the spectrum, RI sensitivities of -72.247dB/RIU and 68.122nm/RIU, as well as temperature sensitivities of 0.0283dB/degrees C and -17pm/degrees C are obtained. Further, the sensing scheme could also provide the feasibility to construct a more compact sensing probe for dual-paramters measurement, which has great potential in bio/chemical detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presented are the design and results of a reconfigurable UWB filtenna with sharp dual bandnotch at WiMAX 3.5 GHz and WLAN 5.8 GHz bands. The filtenna is formed by placing three loop resonators in an UWB antenna. The resonators are fitted with Graphene based switches which introduce reconfigurability. The filtenna was simulated electromagnetically and with Graphene based switches in switches OFF and switches ON states. Presented results show a passband from 2.81–12.27 GHz in OFF state and ON state results in sharp dual bandnotch within the passband at 3.45 and 5.95 GHz at a return loss of 2–2.5 dB. The gain and efficiency in both states has also been given and is reduced in ON state at the dual bandnotch. The radiation patterns in E- and H-planes are stable.