853 resultados para Cleaning validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE: An objective and simple prognostic model for patients with pulmonary embolism could be helpful in guiding initial intensity of treatment. OBJECTIVES: To develop a clinical prediction rule that accurately classifies patients with pulmonary embolism into categories of increasing risk of mortality and other adverse medical outcomes. METHODS: We randomly allocated 15,531 inpatient discharges with pulmonary embolism from 186 Pennsylvania hospitals to derivation (67%) and internal validation (33%) samples. We derived our prediction rule using logistic regression with 30-day mortality as the primary outcome, and patient demographic and clinical data routinely available at presentation as potential predictor variables. We externally validated the rule in 221 inpatients with pulmonary embolism from Switzerland and France. MEASUREMENTS: We compared mortality and nonfatal adverse medical outcomes across the derivation and two validation samples. MAIN RESULTS: The prediction rule is based on 11 simple patient characteristics that were independently associated with mortality and stratifies patients with pulmonary embolism into five severity classes, with 30-day mortality rates of 0-1.6% in class I, 1.7-3.5% in class II, 3.2-7.1% in class III, 4.0-11.4% in class IV, and 10.0-24.5% in class V across the derivation and validation samples. Inpatient death and nonfatal complications were <or= 1.1% among patients in class I and <or= 1.9% among patients in class II. CONCLUSIONS: Our rule accurately classifies patients with pulmonary embolism into classes of increasing risk of mortality and other adverse medical outcomes. Further validation of the rule is important before its implementation as a decision aid to guide the initial management of patients with pulmonary embolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: People suffering from mental illness are exposed to stigma. However, only few tools are available to assess stigmatization as perceived from the patient's perspective. The aim of this study is to adapt and validate a French version of the Stigma Scale (King et al., 2007 [8]). This self-report questionnaire has a three-factor structure: discrimination, disclosure and positive aspects of mental illness. Discrimination subscale refers to perceived negative reactions of others. Disclosure subscale refers mainly to managing disclosure to avoid discrimination and finally positive aspects subscale taps into how patients are becoming more accepting, more understanding toward their illness. METHOD: In the first step, internal consistency, convergent validity and test-retest reliability of the French adaptation of the 28-item scale were assessed in a sample of 183 patients. Results of confirmatory factor analyses (CFA) did not confirm the hypothesized structure. In the light of the failed attempts to validate the original version, an alternative 9-item short-form version of the Stigma Scale, maintaining the integrity of the original model, was developed based on results of exploratory factor analyses in the first sample and cross-validated in a new sample of 234 patients. RESULTS: Results of CFA did not confirm that the data fitted well to the three-factor model of the 28-item Stigma Scale (χ(2)/df=2.02, GFI=0.77, AGFI=0.73, RMSEA=0.07, CFI=0.77 and NNFI=0.75). Cronbach's α was excellent for discrimination (0.84) and disclosure (0.83) subscales but poor for potential positive aspects (0.46). External validity was satisfactory. Overall Stigma Scale total score was negatively correlated with the score on Rosenberg's Self-Esteem Scale (r=-0.49), and each subscale was significantly correlated with a visual analogue scale that referred to the specific aspect of stigma (0.43≤|r|≤0.60). Intraclass correlation coefficients between 0.68 and 0.89 indicated good test-retest reliability. The results of the CFA demonstrated that the items chosen for the short version of the Stigma Scale have the expected fit properties (χ(2)/df=1.02, GFI=0.98, AGFI=0.98, RMSEA=0.01, CFI=1.0 and NNFI=1.0). Considering the small number (three) of items in each subscale of the short version of the Stigma Scale, α coefficients for discrimination (0.57), disclosure (0.80) and potential positive aspects subscales (0.62) are considered as good. CONCLUSION: Our results suggest that the 9-item French short version of the Stigma Scale is a useful, reliable and valid self-report questionnaire to assess perceived stigmatization in people suffering from mental illness. The time of completion is really short and questions are well understood and accepted by the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In response to an increasing need for ever-shorter personality instruments, Gosling, Rentfrow, and Swann (2003) developed the Ten-Item-Personality Inventory (TIPI), which measures the dimensions of the Five Factor Model (FFM) using 10 items (two for each dimension) and can be administered in about one minute. In two studies and using a multi-judge (self and observer) and multi-instrument design, we develop Spanish (Castilian) and Catalan versions of the TIPI and evaluate them in terms of internal consistency, test-retest reliability, convergent, discriminant, and content validity, as well as self-observer correlations. Test-retest correlations were strong, and convergence with the NEO-PI-R factors was significant. There were also strong correlations between observer ratings and the participants’ self-ratings. Despite some inconsistencies with respect to the Agreeableness scale, the Catalan translation and both translations into Spanish of the original TIPI demonstrated sufficient psychometric properties to warrant use as a Five Factor personality measure when the use of longer instruments is not convenient or possible. Furthermore, as the first translation of a brief standard Big Five Instrument into Catalan, this work should facilitate future research on personality in the Catalan-speaking population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to validate microsatellite markers associated with resistance to soybean cyst nematode (Heterodera glycines Ichinohe) races 3 and 14, in soybean (Glycine max L.) genotypes, for use in marker-assisted selection (MAS) programs. Microsatellites of soybean linkage groups A2, D2 and G were tested in two populations, and their selection efficiencies were determined. The populations were 65 F2:3 families from Msoy8001 (resistant) x Conquista (susceptible) cross, and 66 F2:3 families of S5995 (resistant) x Renascença (susceptible) cross, evaluated for resistance to races 3 and 14, respectively. Families with female index up to 30% were considered moderately resistant. Markers of A2 and G linkage groups were associated with resistance to race 3. Markers Satt309 and GMENOD2B explained the greatest proportion of phenotypic variance in the different groups. The combinations Satt309+GMENOD2B and Satt309+Satt187 presented 100% selection efficiency. Resistance to race 14 was associated with markers of G linkage group, and selection efficiency in the Satt309+Satt356 combination was 100%. The selection differential obtained by phenotypic and marker assisted selection showed that both can result in similar gains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fondement L'appréciation objective du résultat des actes chirurgicaux fait partie de la démarche d'évaluation des pratiques professionnelles, notamment en chirurgie orthopédique pour le résultat des prothèses articulaires. Dans cette optique, les questionnaires « auto-administrés » par les patients offrent une solution séduisante, mais peu utilisée en France. Le questionnaire anglais Oxford Hip Score en 12 questions (OHS-12) a été sélectionné pour cette étude en raison de sa facilité d'utilisation. Hypothèse Le but de ce travail était de valider la traduction française du score d'autoévaluation Oxford-12 et d'en confronter les résultats à ceux des scores fonctionnels de références, de Harris (HHS) et de Merle d'Aubigné (PMA). Matériel et méthode À partir d'une série clinique de 242 patients candidats à une arthroplastie de hanche, une validation de la traduction en langue française de ce questionnaire a été réalisée, ainsi qu'une évaluation de sa cohérence par confrontation des données obtenues en préopératoire avec celles provenant des deux scores cliniques de référence. Résultats La traduction a été validée selon le processus de traduction inverse du français à l'anglais avec correction de toute déviation ou contresens après comparaison systématisée avec le questionnaire original anglais. La moyenne du score global OHS-12 était de 43,8 points (22 à 60 points) avec une bonne distribution de la valeur globale des trois scores comparés. La corrélation était excellente entre OHS et HHS, mais une corrélation de niveau identique entre OHS et PMA n'a été obtenue que pour l'association des paramètres douleur et fonction, après exclusion du critère mobilité relativement surreprésenté dans le score PMA. Discussion et conclusion Le recours à des questionnaires subjectifs qui apportent une appréciation personnelle du résultat de l'arthroplastie par le patient est facilement applicable à grande échelle. Ce travail permet de mettre à la disposition des chirurgiens orthopédistes français une version traduite et validée d'un score d'autoévaluation fiable et internationalement reconnu. Les résultats obtenus nous incitent à privilégier l'utilisation de ce questionnaire en complément des scores et méthodes d'évaluation classiques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report is submitted in compliance with Administrative Rule 761-401.18(3), Discontinuance, and discusses seven special registration plates established by the legislature in 2011. This rule requires the department to report to the legislature if any of the special registration plates subject to this rule have not been placed into production because the department has not received the minimum number of paid applications (250) required to produce the plates under Iowa Code section 321.34, subsections 20C, 25 and 26 as amended by 2011 Iowa Acts, House File 651, section 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, notably because of lack of validated tools, in accordance with recognized psychometric criteria. The Spinal Function Sort (SFS), developed according to actual standards, was only validated in English. The aim of this study is to translate, adapt and validate the French and German version of the SFS.Method and material: The translation and cross-cultural adaptation were performed following the methodology proposed by the American Association of Orthopedist Surgeon. A total of 344 patients, presenting varied back complaints (especially degenerative and traumatic), took part in this study in a tertiary French- (n=87; mean age 44y; 17 women) and German-speaking (n=257; mean age 41y; 53 women) center. Test-retest reliability was quantified using the intraclass correlation coefficient (ICC) and construct validity was assessed by estimating the Pearson's correlation with the SF-36 physical and mental scales, the Visual Analogue Scale for Pain Intensity (VAS), and subscales of the Hospital Anxiety and Depression Scale (HADS).Results: Respectively for the French and German version, ICC were 0.98 and 0.94. Correlations 0.63 and 0.67 with the SF-36 Physical Functioning subscale; 0.60 and 0.52 with the SF-36 Physical Summary Scale ; -0.33 and -0.51 with the VAS ; -0.08 and 0.25 with the SF-36 Mental Health scale; 0.01 and 0.28 with the SF-36 Mental Summary Scale; -0.26 and -0.42 with the HADS depression; -0.17 and -0.45 with the HADS anxiety.Discussion: For both the French and German version of the SFS, the reliability was excellent. Convergent construct validity with SF-36 physical scales is good, moderated with the VAS. We find out a low correlation with SF-36 mental scales (divergent construct validity). We find out a low correlation with HADS subscales in the French version, and a moderate one in the German version. Selection bias, chronicity of the complaints, as well as cultural differences could explain these results. In conclusion, both the French and German version of the SFS are valid and reliable for evaluation of perceived functional capacity for patients with back complaints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Social learning and the formation of traditions rely on the ability and willingness to copy one another. A central question is under which conditions individuals adapt behaviour to social influences. Here, we demonstrate that similarities in food processing techniques emerge on the level of matrilines (mother-offspring) but not on the group level in an experiment on six groups of wild vervet monkeys that involved grapes covered with sand. Monkeys regularly ate unclean grapes but also used four cleaning techniques more similarly within matrilines: rubbing in hands, rubbing on substrate, open with mouth, and open with hands. Individual cleaning techniques evolved over time as they converged within matrilines, stabilised at the end and remained stable in a follow-up session more than one year later. The similarity within matrilines persisted when we analyzed only foraging events of individuals in the absence of other matriline members and matriline members used more similar methods than adult full sisters. Thus, momentary conversion or purely genetic causation are unlikely explanations, favouring social learning as mechanism for within matriline similarities. The restriction of traditions to matriline membership rather than to the group level may restrict the development of culture in monkeys relative to apes or humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last five years, Deep Brain Stimulation (DBS) has become the most popular and effective surgical technique for the treatent of Parkinson's disease (PD). The Subthalamic Nucleus (STN) is the usual target involved when applying DBS. Unfortunately, the STN is in general not visible in common medical imaging modalities. Therefore, atlas-based segmentation is commonly considered to locate it in the images. In this paper, we propose a scheme that allows both, to perform a comparison between different registration algorithms and to evaluate their ability to locate the STN automatically. Using this scheme we can evaluate the expert variability against the error of the algorithms and we demonstrate that automatic STN location is possible and as accurate as the methods currently used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validation is the main bottleneck preventing theadoption of many medical image processing algorithms inthe clinical practice. In the classical approach,a-posteriori analysis is performed based on someobjective metrics. In this work, a different approachbased on Petri Nets (PN) is proposed. The basic ideaconsists in predicting the accuracy that will result froma given processing based on the characterization of thesources of inaccuracy of the system. Here we propose aproof of concept in the scenario of a diffusion imaginganalysis pipeline. A PN is built after the detection ofthe possible sources of inaccuracy. By integrating thefirst qualitative insights based on the PN withquantitative measures, it is possible to optimize the PNitself, to predict the inaccuracy of the system in adifferent setting. Results show that the proposed modelprovides a good prediction performance and suggests theoptimal processing approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Head space gas chromatography with flame-ionization detection (HS-GC-FID), ancl purge and trap gas chromatography-mass spectrometry (P&T-GC-MS) have been used to determine methyl-tert-butyl ether (MTBE) and benzene, toluene, and the ylenes (BTEX) in groundwater. In the work discussed in this paper measures of quality, e.g. recovery (94-111%), precision (4.6 - 12.2%), limits of detection (0.3 - 5.7 I~g L 1 for HS and 0.001 I~g L 1 for PT), and robust-ness, for both methods were compared. In addition, for purposes of comparison, groundwater samples from areas suffering from odor problems because of fuel spillage and tank leakage were analyzed by use of both techniques. For high concentration levels there was good correlation between results from both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chaque jour, le médecin utilise dans sa pratique des scores cliniques. Ces scores sont souvent des aides à la décision médicale. Les étapes de validation des scores cliniques sont par contre souvent méconnues du médecin. Cette revue rappelle les bases théoriques de la validation d'un score clinique et propose des exercices pratiques. [Abstract] Physicians are using clinical scores on a regular basis. These scores are generally helpful in making medical decisions. However, the process of validation of clinical scores is often unknown to the physicians. This paper reviews the theory of validation of clinical scores and proposes practical exercises.