550 resultados para Chichester
Resumo:
Tin-containing fluoride solutions can reduce erosive tissue loss, but the effects of the reaction between tin and enamel are still not clear. During a 10-d period, enamel specimens were cyclically demineralized (0.05 M citric acid, pH 2.3, 6 x 5 min d(-1)) and remineralized (between the demineralization cycles and overnight). In the negative-control group, no further treatment was performed. Three groups were treated (2 x 2 min d(-1)) with tin-containing fluoride solutions (400, 1,400 or 2,100 ppm Sn2+, all 1,500 ppm F-, pH 4.5). Three additional groups were treated with test solutions twice daily, but without demineralization. Tissue loss was determined profilometrically. Energy-dispersive X-ray spectroscopy was used to measure the tin content on and within three layers (10 mum each) beneath the surface. In addition, scanning electron microscopy was conducted. All test preparations significantly reduced tissue loss. Deposition of tin on surfaces was higher without erosion than with erosion, but no incorporation of tin into enamel was found without demineralization. Under erosive conditions, both highly concentrated solutions led to the incorporation of tin up to a depth of 20 mum; the less-concentrated solution led to small amounts of tin in the outer 10 mum. The efficacy of tin-containing solutions seems to depend mainly on the incorporation of tin into enamel.
Resumo:
AIM: The aim of this Case Series was to evaluate the radiographic quality of root fillings performed 5 years previously using the noninstrumentation technology (NIT)-obturation method and to assess radiographically the outcome of these root canal treatments. METHODOLOGY: Seventeen patients requiring root canal treatment participated in this study and were re-evaluated after 5 years. After instrumentation with K-Flexofiles, Calcium-Hydroxide inter-appointment dressing, re-entry and copious irrigation with NaOCl, the teeth were root filled using the NIT. RESULTS: Immediately after obturation the root fillings were (-0.78 +/- 0.11 mm) short when taking the radiographic apex as a reference point. After 60 months these values were -0.85 +/- 0.11 mm. No statistical difference was found (P > 0.05). In the periapical region, PAI rating 1 and 2 increased from 20.1% to 75.6% after 60 months. CONCLUSIONS: * This prospective Case Series demonstrated the performance of the NIT-obturation method in vivo. * Root canals filled by the reduced-pressure method using sealer combined with gutta-percha cones showed good radiographic quality. * Periapical healing after 5 years was comparable with conventional filling techniques.
Resumo:
OBJECTIVES: Wear of attachments leads to a loss of retention and potentially reduces the function of complete dentures. This study evaluated the retention force changes of different prefabricated attachment systems for implant-supported overdentures to estimate the wear constancy and applicability in clinical practice. METHODS: Four prefabricated attachment systems were tested [Group SG: retentive ball attachment (Straumann, Switzerland) with gold matrix, Group ST: retentive ball attachment (Straumann, Switzerland) with titanium spring matrix, Group IB: UNOR i-Ball with Ecco matrix (UNOR, Switzerland) and Group IMZ: IMZ-TwinPlus ball attachment with gold matrix (DENTSPLY Friadent, Germany)]. Ten samples of each system were subjected to 10,000 insertion-separation cycles. RESULTS: Results showed that all types of attachments showed wear, which led to a loss of retention force after an initial increase at the beginning of the wear simulation. Attachments with a plastic retention insert or gold matrices underwent the smallest changes in retention force. The titanium spring system showed the largest changes in retention force and a greater variation between the different cycles and specimen. This behaviour is probably caused by a large fitting tolerance of the titanium spring. CONCLUSIONS: Attachment systems which possess a male and female component of different material composition are preferable. They show smaller changes in the retention force. For retention force increase and wear compensation, an attachment system should be adjustable.
Resumo:
BACKGROUND: Current international treatment guidelines recommending therapeutic exercise for people with symptomatic hip OA report are based on expert opinion only. OBJECTIVES: To determine whether land-based therapeutic exercise is beneficial for people with hip OA in terms of reduced joint pain and/or improved physical function. SEARCH STRATEGY: Five databases were searched from 1966 up until August 2008. SELECTION CRITERIA: All randomised controlled trials (RCTs) recruiting people with hip OA and comparing some form of land-based therapeutic exercise (as opposed to exercises conducted in the water) with a non-exercise group. DATA COLLECTION AND ANALYSIS: Three reviewers independently extracted data and assessed methodological quality. All analyses were conducted on continuous outcomes. MAIN RESULTS: Combining the results of the five included RCTs demonstrated a small treatment effect for pain, but no benefit in terms of improved self-reported physical function. Only one of these five RCTs exclusively recruited people with symptomatic hip OA. AUTHORS' CONCLUSIONS: The limited number and small sample size of the included RCTs restricts the confidence that can be attributed to these results. Adequately powered RCTs evaluating exercise programs specifically designed for people with symptomatic hip OA need to be conducted.
Resumo:
OBJECTIVES: In fetal ultrasound imaging, teaching and experience are of paramount importance to improve prenatal detection rates of fetal abnormalities. Yet both aspects depend on exposure to normal and, in particular, abnormal 'specimens'. We aimed to generate a number of simple virtual reality (VR) objects of the fetal central nervous system for use as educational tools. METHODS: We applied a recently proposed algorithm for the generation of fetal VR object movies to the normal and abnormal fetal brain and spine. Interactive VR object movies were generated from ultrasound volume data from normal fetuses and fetuses with typical brain or spine anomalies. Pathognomonic still images from all object movies were selected and annotated to enable recognition of these features in the object movies. RESULTS: Forty-six virtual reality object movies from 22 fetuses (two with normal and 20 with abnormal brains) were generated in an interactive display format (QuickTime) and key images were annotated. The resulting .mov files are available for download from the website of this journal. CONCLUSIONS: VR object movies can be generated from educational ultrasound volume datasets, and may prove useful for teaching and learning normal and abnormal fetal anatomy.
Resumo:
OBJECTIVE: To assess the types and numbers of cases, gestational age at specific prenatal diagnosis and diagnostic accuracy of the diagnosis of skeletal dysplasias in a prenatal population from a single tertiary center. METHODS: This was a retrospective database review of type, prenatal and definitive postnatal diagnoses and gestational age at specific prenatal diagnosis of all cases of skeletal dysplasias from a mixed referral and screening population between 1985 and 2007. Prenatal diagnoses were grouped into 'correct ultrasound diagnosis' (complete concordance with postnatal pediatric or pathological findings) or 'partially correct ultrasound diagnosis' (skeletal dysplasias found postnatally to be a different one from that diagnosed prenatally). RESULTS: We included 178 fetuses in this study, of which 176 had a prenatal ultrasound diagnosis of 'skeletal dysplasia'. In 160 cases the prenatal diagnosis of a skeletal dysplasia was confirmed; two cases with skeletal dysplasias identified postnatally had not been diagnosed prenatally, giving 162 fetuses with skeletal dysplasias in total. There were 23 different classifiable types of skeletal dysplasia. The specific diagnoses based on prenatal ultrasound examination alone were correct in 110/162 (67.9%) cases and partially correct in 50/162 (30.9%) cases, (160/162 overall, 98.8%). In 16 cases, skeletal dysplasia was diagnosed prenatally, but was not confirmed postnatally (n = 12 false positives) or the case was lost to follow-up (n = 4). The following skeletal dysplasias were recorded: thanatophoric dysplasia (35 diagnosed correctly prenatally of 40 overall), osteogenesis imperfecta (lethal and non-lethal, 31/35), short-rib dysplasias (5/10), chondroectodermal dysplasia Ellis-van Creveld (4/9), achondroplasia (7/9), achondrogenesis (7/8), campomelic dysplasia (6/8), asphyxiating thoracic dysplasia Jeune (3/7), hypochondrogenesis (1/6), diastrophic dysplasia (2/5), chondrodysplasia punctata (2/2), hypophosphatasia (0/2) as well as a further 7/21 cases with rare or unclassifiable skeletal dysplasias. CONCLUSION: Prenatal diagnosis of skeletal dysplasias can present a considerable diagnostic challenge. However, a meticulous sonographic examination yields high overall detection. In the two most common disorders, thanatophoric dysplasia and osteogenesis imperfecta (25% and 22% of all cases, respectively), typical sonomorphology accounts for the high rates of completely correct prenatal diagnosis (88% and 89%, respectively) at the first diagnostic examination.
Resumo:
Limited information is available on the time-dependent or dosage-dependent cariostatic efficacy of highly concentrated fluoride compounds. This good clinical practice-conforming, double-blind, placebo-controlled, crossover in situ study tested the hypothesis that a 1.0% amine fluoride fluid is superior to a 0.5% amine fluoride fluid regarding fluoride retention and mineral change in initial caries enamel lesions over a period of 28 d. Fluoride retention was significantly higher after application of the two fluoride fluids compared with placebo but had decreased in both groups to similar levels after only 1 wk. Mineral gain was significantly higher for both verum groups compared with placebo. The use of 1% fluoride fluid resulted in significantly higher remineralization compared with the use of 0.5% fluoride fluid. For both fluoride fluids mineral gain followed a linear relationship with time during the experimental period, indicating a possible further uptake of mineral, even after 4 wk.
Resumo:
BACKGROUND: In this paper we present a landmark-based augmented reality (AR) endoscope system for endoscopic paranasal and transnasal surgeries along with fast and automatic calibration and registration procedures for the endoscope. METHODS: Preoperatively the surgeon selects natural landmarks or can define new landmarks in CT volume. These landmarks are overlaid, after proper registration of preoperative CT to the patient, on the endoscopic video stream. The specified name of the landmark, along with selected colour and its distance from the endoscope tip, is also augmented. The endoscope optics are calibrated and registered by fast and automatic methods. Accuracy of the system is evaluated in a metallic grid and cadaver set-up. RESULTS: Root mean square (RMS) error of the system is 0.8 mm in a controlled laboratory set-up (metallic grid) and was 2.25 mm during cadaver studies. CONCLUSIONS: A novel landmark-based AR endoscope system is implemented and its accuracy is evaluated. Augmented landmarks will help the surgeon to orientate and navigate the surgical field. Studies prove the capability of the system for the proposed application. Further clinical studies are planned in near future.
Resumo:
Sustained growth of solid tumours can rely on both the formation of new and the co-option of existing blood vessels. Current models suggest that binding of angiopoietin-2 (Ang-2) to its endothelial Tie2 receptor prevents receptor phosphorylation, destabilizes blood vessels, and promotes vascular permeability. In contrast, binding of angiopoietin-1 (Ang-1) induces Tie2 receptor activation and supports the formation of mature blood vessels covered by pericytes. Despite the intense research to decipher the role of angiopoietins during physiological neovascularization and tumour angiogenesis, a mechanistic understanding of angiopoietin function on vascular integrity and remodelling is still incomplete. We therefore assessed the vascular morphology of two mouse mammary carcinoma xenotransplants (M6378 and M6363) which differ in their natural angiopoietin expression. M6378 displayed Ang-1 in tumour cells but no Ang-2 in tumour endothelial cells in vivo. In contrast, M6363 tumours expressed Ang-2 in the tumour vasculature, whereas no Ang-1 expression was present in tumour cells. We stably transfected M6378 mouse mammary carcinoma cells with human Ang-1 or Ang-2 and investigated the consequences on the host vasculature, including ultrastructural morphology. Interestingly, M6378/Ang-2 and M6363 tumours displayed a similar vascular morphology, with intratumoural haemorrhage and non-functional and abnormal blood vessels. Pericyte loss was prominent in these tumours and was accompanied by increased endothelial cell apoptosis. Thus, overexpression of Ang-2 converted the vascular phenotype of M6378 tumours into a phenotype similar to M6363 tumours. Our results support the hypothesis that Ang-1/Tie2 signalling is essential for vessel stabilization and endothelial cell/pericyte interaction, and suggest that Ang-2 is able to induce a switch of vascular phenotypes within tumours.
Resumo:
Non-alcoholic fatty liver disease (NAFLD) is associated with features of the metabolic syndrome (MetS) and may be an expression of the syndrome within the liver. Using screening data from the Nateglinide And Valsartan in Impaired Glucose Tolerance Outcomes Research (NAVIGATOR) study (n = 42 149), we examined whether alanine aminotransferase (ALT), a biomarker for NAFLD, clustered with features of MetS and whether the clusters differed across global geographic regions.