881 resultados para Channel Block


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The epithelial sodium channel (ENaC) is composed of three homologous subunits α, ß, and γ. This channel is involved in the regulation of sodium balance, which influences the periciliary liquid level in the lung, and blood pressure via the kidney. ENaC expressed in Xenopus laevis oocytes is preferentially and rapidly assembled into heteromeric αßγ complexes. Expression of homomeric α or heteromeric αß and αγ complexes lead to channel expression at the cell surface wíth low activities. Recent studies have demonstrated that α and γ (but not ß) ENaC subunits undergo proteolytic cleavage by endogenous proteases (i.e. furin) correlating with increased channel activity. We therefore assayed the full-length subunits and their cleavage products at the cell surface, as well as in the intracellular pool for all homo- and heteromeric combínations (α, ß, γ, ßγ, αß, αγ, ßγ and αßγ) and measured the corresponding channel activities as amiloride-sensitive sodíum transport (INa). We showed that upon assembly, cleavage of the y ENaC subunit ís responsible for increasing INa. We further demonstrated that in disease states such as cystic fibrosis (CF) where there is disequilibrium in the proteaseprotease inhibitor balance, ENaC is over-activated by the serine protease elastase (NE). We demonstrated that elevated NE concentrations can cleave cell surface expressed γ ENaC (but not α, or ß ENaC), suggesting a causal relationship between γ ENaC cleavage and ENaC activation, taking place at the plasma membrane. In addition, we demonstrated that the serine protease inhibitor (serpin) serpinH1, which is co-expressed with ENaC in the distal nephron is capable of inhibiting the channel by preventing cleavage of the γ ENaC subunit. Aldosterone mediated increases in INa aze known to be inhibted by TGFß. TGFß is also known to increase serpinHl expression. The demonstrated inhibition of γ ENaC cleavage and channel activation by serpinH1 may be responsible for the effect of TGFß on aldosterone stimulation in the distal nephron. In summary, we show that cleavage of the γ subunit, but not the α or ß subunit is linked to channel activation in three seperate contexts. Résumé Le canal épithélial à sodium (ENaC) est constitué de trois sous-unités homologues α, ß, and γ. Ce canal est impliqué dans le maintien de la balance sodique qui influence le niveau du liquide périciliaire du poumon et la pression sanguine via le rein. Dans les ovocytes de Xenopus laevis ENaC est préférentiellement et rapidement exprimé en formant un complexe hétéromérique αßγ. En revanche, l'expression homomérique de α ou hétéromérique des complexes αß et αγ conduit à une expression à la surface cellulaire d'un canal ENaC ne possédant qu'une faible activité. Des études récentes ont mis en évidence que les sous-unités α et γ d'ENaC (mais pas ß) sont coupées par des protéases endogènes (les farines) et que ces clivages augmentent l'activité du canal. Nous avons donc analysé, aussi bien à la surface cellulaire que dans le cytoplasme, les produits des clivages de combinaison homo- et hétéromérique des sous-unités d'ENaC (α, ß, γ, ßγ, αß, αγ, ßγ et αßγ). En parallèle, nous avons étudié l'activité correspondante à ces canaux par la mesure du transport de sodium sensible à l'amiloride (INa). Nous avons montré que lors de l'assemblage des sous-unités d'ENaC, le clivage de γ correspond à l'augmentation de INa. Nous avons également mis en évidence que dans une maladie telle que la fibrose cystique (CF) caractérisée par un déséquilibre de la balance protéase-inhibiteur de protéase, ENaC est suractivé par une sérine protéase nommée élastase (NE). L'augmentation de la concentration de NE clive γ ENaC exprimé à la surface cellulaire (mais pas α, ni ß ENaC) suggérant une causalité entre le clivage d'ENaC et son activation à la membrane plasmique. De plus, nous avons démontré que l'inhibiteur de sérine protéase (serpin) serpinH1, qui est co-exprimé avec ENaC dans le néphron distal, inhibe l'activité du canal en empêchant le clivage de la sous-unité γ ENaC. Il est connu que le INa induit par l'aldostérone peut être inhibé par TGFß. Or TGFß augmente l'expression de serpinH1. L'inhibition du clivage de γ ENaC et de l'activation du canal par la serpinH1 que nous avons mis en évidence pourrait ainsi être responsable de l'effet de TGFß sur la stimulation du courant par l'aldostérone dans le néphron distal. En résumé, nous avons montré que le clivage de la sous-unité γ, mais pas des sous-unités α et ß, est lié à l'activation du canal dans trois contextes distincts. Résumé tout public Le corps humain est composé d'environ 10 000 milliards de cellules et d'approximativement 60% d'eau. Les cellules du corps sont les unités fondamentales de la vie et elles sont dépendantes de certains nutriments et molécules. Ces nutriments et molécules sont dissous dans l'eau qui est présente dans et hors des cellules. Le maintien d'une concentration adéquate - de ces nutriments et de ces molécules dans l'eau à l'intérieur et à l'extérieur des cellules est -..essentiel pour leur survie. L'eau hors des cellules est nommée le fluide extracellulaire et peut être subdivisée en fluide interstitiel, qui se trouve autour des cellules, et en plasma, qui est le fluide des vaisseaux sanguins. Les fluides, les nutriments et les molécules sont constamment échangés entre les cellules, le fluide interstitiel, et le plasma. Le plasma circule dans le système circulatoire afin de distribuer les nutriments et molécules dans tout le corps et afin d'enlever les déchets cellulaires. Le rein joue un rôle essentiel dans la régulation du volume et de la concentration du plasma en éliminant sélectivement les nutriments et les molécules via la formation de l'urine. L'être humain possède deux reins, constitués chacun d'environ 1 million de néphrons. Ces derniers sont responsables de réabsorber et de sécréter sélectivement les nutriments et les molécules. Le canal épithélial à sodium (ENaC) est localisé à la surface cellulaire des néphrons et est responsable de la réabsorption du sodium (Na+). Le Na+ est présent dans quasiment toute la nourriture que nous mangeons et représente, en terme de molécule, 50% du sel de cuisine. Si trop de sodium est consommé, ENaC est inactif, si bien que le Na+ n'est pas réabsorbé et quitte le corps par l'urine. Ce mécanisme permet d'éviter que la concentration plasmatique de Na+ ne devienne trop grande, ce qui résulterait en une augmentation de la pression sanguine. Si trop peu de Na+ est consommé, ENaC réabsorbe le Na+ de l'urine primaire ce qui permet de conserver la concentration de Na+ et de prévenir une diminution de la pression sanguine par une perte de Na+. ENaC est aussi présent dans les cellules des poumons qui sont les organes permettant la respiration. La respiration est aussi essentielle pour la survie des cellules. Les poumons ne doivent pas contenir trop de liquide afin de permettre la respiration, mais en même temps ils ne doivent pas non plus être trop secs. En effet, ceci tuerait les cellules et empêcherait aussi la respiration. ENaC permet de maintenir un niveau d'humidité approprié dans les poumons en absorbant du Na+ ce qui entraîne un mouvement osmotique d'eau. L'absorption de sodium par ENaC ~ est augmentée par les protéases (in vitro et ex vivo). Les protéases sont des molécules qui peuvent couper d'autres molécules à des endroits précis. Nous avons démonté que certaines protéases augmentent l'absorption de Na+ en coupant ENaC à des endroits spécifiques. L'inhibition de ces protéases diminue le transport de Na+ et empêche le clivage d'ENaC. Dans certaines maladies telle que la mucoviscidose, des protéases sont suractivées et augmentent l'activité d'ENaC de manière inappropriée conduisant à une trop forte absorption de Na+ et à un déséquilibre de la muqueuse des poumons. Cette étude est donc particulièrement importante dans le cadre de la recherche thérapeutique de ce genre de maladie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date, published studies of alluvial bar architecture in large rivers have been restricted mostly to case studies of individual bars and single locations. Relatively little is known about how the depositional processes and sedimentary architecture of kilometre-scale bars vary within a multi-kilometre reach or over several hundreds of kilometres downstream. This study presents Ground Penetrating Radar and core data from 11, kilometre-scale bars from the Rio Parana, Argentina. The investigated bars are located between 30km upstream and 540km downstream of the Rio Parana - Rio Paraguay confluence, where a significant volume of fine-grained suspended sediment is introduced into the network. Bar-scale cross-stratified sets, with lengths and widths up to 600m and thicknesses up to 12m, enable the distinction of large river deposits from stacked deposits of smaller rivers, but are only present in half the surface area of the bars. Up to 90% of bar-scale sets are found on top of finer-grained ripple-laminated bar-trough deposits. Bar-scale sets make up as much as 58% of the volume of the deposits in small, incipient mid-channel bars, but this proportion decreases significantly with increasing age and size of the bars. Contrary to what might be expected, a significant proportion of the sedimentary structures found in the Rio Parana is similar in scale to those found in much smaller rivers. In other words, large river deposits are not always characterized by big structures that allow a simple interpretation of river scale. However, the large scale of the depositional units in big rivers causes small-scale structures, such as ripple sets, to be grouped into thicker cosets, which indicate river scale even when no obvious large-scale sets are present. The results also show that the composition of bars differs between the studied reaches upstream and downstream of the confluence with the Rio Paraguay. Relative to other controls on downstream fining, the tributary input of fine-grained suspended material from the Rio Paraguay causes a marked change in the composition of the bar deposits. Compared to the upstream reaches, the sedimentary architecture of the downstream reaches in the top ca 5m of mid-channel bars shows: (i) an increase in the abundance and thickness (up to metre-scale) of laterally extensive (hundreds of metres) fine-grained layers; (ii) an increase in the percentage of deposits comprised of ripple sets (to >40% in the upper bar deposits); and (iii) an increase in bar-trough deposits and a corresponding decrease in bar-scale cross-strata (<10%). The thalweg deposits of the Rio Parana are composed of dune sets, even directly downstream from the Rio Paraguay where the upper channel deposits are dominantly fine-grained. Thus, the change in sedimentary facies due to a tributary point-source of fine-grained sediment is primarily expressed in the composition of the upper bar deposits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimation of the dimensions of fluvial geobodies from core data is a notoriously difficult problem in reservoir modeling. To try and improve such estimates and, hence, reduce uncertainty in geomodels, data on dunes, unit bars, cross-bar channels, and compound bars and their associated deposits are presented herein from the sand-bed braided South Saskatchewan River, Canada. These data are used to test models that relate the scale of the formative bed forms to the dimensions of the preserved deposits and, therefore, provide an insight as to how such deposits may be preserved over geologic time. The preservation of bed-form geometry is quantified by comparing the Alluvial architecture above and below the maximum erosion depth of the modem channel deposits. This comparison shows that there is no significant difference in the mean set thickness of dune cross-strata above and below the basal erosion surface of the contemporary channel, thus suggesting that dimensional relationships between dune deposits and the formative bed-form dimensions are likely to be valid from both recent and older deposits. The data show that estimates of mean bankfull flow depth derived from dune, unit bar, and cross-bar channel deposits are all very similar. Thus, the use of all these metrics together can provide a useful check that all components and scales of the alluvial architecture have been identified correctly when building reservoir models. The data also highlight several practical issues with identifying and applying data relating to cross-strata. For example, the deposits of unit bars were found to be severely truncated in length and width, with only approximately 10% of the mean bar-form length remaining, and thus making identification in section difficult. For similar reasons, the deposits of compound bars were found to be especially difficult to recognize, and hence, estimates of channel depth based on this method may be problematic. Where only core data are available (i.e., no outcrop data exist), formative flow depths are suggested to be best reconstructed using cross-strata formed by dunes. However, theoretical relationships between the distribution of set thicknesses and formative dune height are found to result in slight overestimates of the latter and, hence, mean bankfull flow depths derived from these measurements. This article illustrates that the preservation of fluvial cross-strata and, thus, the paleohydraulic inferences that can be drawn from them, are a function of the ratio of the size and migration rate of bed forms and the time scale of aggradation and channel migration. These factors must thus be considered when deciding on appropriate length:thickness ratios for the purposes of object-based modeling in reservoir characterization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present experiments in which the laterally confined flow of a surfactant film driven by controlled surface tension gradients causes the subtended liquid layer to self-organize into an inner upstream microduct surrounded by the downstream flow. The anomalous interfacial flow profiles and the concomitant backflow are a result of the feedback between two-dimensional and three-dimensional microfluidics realized during flow in open microchannels. Bulk and surface particle image velocimetry data combined with an interfacial hydrodynamics model explain the dependence of the observed phenomena on channel geometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää, kokevatko matkapuhelinalalla toimivat kanavapartnerit heitä varten suunnitellun asiakassuhdehallintajärjestelmän lisäarvopalveluna vaiko eivät. Työ toteutettiin asiakastyytyväisyystutkimuksen avulla, jossa mitattiin erilaisten partnereiden asennetta palvelua kohtaan. Työn tuloksena ilmeni, että palvelussa olevan informaation määrällä ei ollut suurta vaikutusta asiakkaiden tyytyväisyyteen. Syyt ovat pikemminkin yleisissä asenteissa vastaavia palveluja kohtaan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chicken acid-sensing ion channel ASIC1 has been crystallized as a homotrimer. We address here the oligomeric state of the functional ASIC1 in situ at the cell surface. The oligomeric states of functional ASIC1a and mutants with additional cysteines introduced in the extracellular pore vestibule were resolved on SDS-PAGE. The functional ASIC1 complexes were stabilized at the cell surface of Xenopus laevis oocytes or CHO cells either using the sulfhydryl crosslinker BMOE, or sodium tetrathionate (NaTT). Under these different crosslinking conditions ASIC1a migrates as four distinct oligomeric states that correspond by mass to multiples of a single ASIC1a subunit. The relative importance of each of the four ASIC1a oligomers was critically dependent on the availability of cysteines in the transmembrane domain for crosslinking, consistent with the presence of ASIC1a homo-oligomers. The expression of ASIC1a monomers, trimeric or tetrameric concatemeric cDNA constructs resulted in functional channels. The resulting ASIC1a complexes are resolved as a predominant tetramer over the other oligomeric forms, after stabilization with BMOE or NaTT and SDS-PAGE/western blot analysis. Our data identify a major ASIC1a homotetramer at the surface membrane of the cell expressing functional ASIC1a channel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The membrane-bound serine protease CAP2/Tmprss4 has been previously identified in vitro as a positive regulator of the epithelial sodium channel (ENaC). To study its in vivo implication in ENaC-mediated sodium absorption, we generated a knockout mouse model for CAP2/Tmprss4. Mice deficient in CAP2/Tmprss4 were viable, fertile, and did not show any obvious histological abnormalities. Unexpectedly, when challenged with sodium-deficient diet, these mice did not develop any impairment in renal sodium handling as evidenced by normal plasma and urinary sodium and potassium electrolytes, as well as normal aldosterone levels. Despite minor alterations in ENaC mRNA expression, we found no evidence for altered proteolytic cleavage of ENaC subunits. In consequence, ENaC activity, as monitored by the amiloride-sensitive rectal potential difference (ΔPD), was not altered even under dietary sodium restriction. In summary, ENaC-mediated sodium balance is not affected by lack of CAP2/Tmprss4 expression and thus, does not seem to directly control ENaC expression and activity in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chest pain is a common presenting symptom in emergency departments, and a typical manifestation of acute myocardial infarction (AMI). Recognition of ECG changes in AMI is essential for timely diagnosis and treatment. Right bundle branch block (RBBB) may be an isolated sign of AMI, and was previously considered as a criterion for fibrinolytic therapy. Since the most recent European Society of Cardiology and American Heart Association guidelines in 2013, RBBB alone is no longer considered a diagnostic criterion of AMI, even if it occurs in the context of acute chest pain, as RBBB does not usually interfere with the interpretation of ST-segment alteration. Our case illustrates an acute septal myocardial infarction with an isolated RBBB, and thus the importance of recognising this pattern in order to permit timely diagnosis and treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS: A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS: Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'arthrose est une maladie dégénérative des articulations due à une dégradation progressive du cartilage. La calcification de l'articulation (essentiellement due à des dépôts de cristaux de phosphate de calcium basique -cristaux BCP-) est une caractéristique de cette maladie. Cependant, le rôle des cristaux BCP reste à déterminer. Nous avons tout d'abord déterminé en utilisant des cultures primaires de chondrocytes que les cristaux de BCP induisaient la production de la cytokine IL-6, via une signalisation intracellulaire implicant les kinase Syk, PI3 et Jak et Stat3. Les cristaux de BCP induisent également la perte de protéoglycanes et l'expression de IL-6 dans des explants de cartlage humain et ces deux effets peuvent être bloqués par un inhibiteur de IL-6, le Tocilizumab. Par ailleurs, nous avons trouvé que l'IL-6 ajouté à des chondrocytes, favorisait la formation de cristax de BCP et augmentait l'expression de gènes impliqués dans le processus de minéralisation : Ank (codant pour un transporteur de pyrophooshate), Annexin5 (codant pour un canal calcique) et Pit-1 (codant pour un transporteur de phoshate). In vivo, les cristaux de BCP injectés dans l'articulation de souris induisent une érosion du cartilage. Dans un modèle murin d'arthrose du genou induit par ménisectomie, nous avons observé la formation progressive de cristaux de BCP. Fait intéressant, la présence de ces cristaux dans l'articulation précédait la destruction du cartilage. Un agent susceptible de bloquer les calcifications tel que le sodium thiosulfate (STS), administré à des souris ménisectomisées, inhibait le dépôt intra-articulaire de ces cristaux ainsi que l'érosion du cartilage. Nous avons identifié ainsi un cercle vicieux dans l'arthrose, les cristaux induisant l'interleukine-6 et l'interleukine-6 induisant la formation de ces cristaux. Nous avons étudié si on pouvait bloquer cette boucle cristaux de BCP-IL6 soit par des agents décalcifiants, soit par des inhibiteurs d'IL-6. In vitro, des anticorps anti IL- 6 ou des inhibiteurs de signalisation, inhibaient significativement IL-6 et la minéralisation induite par IL-6. De même le STS inhibait la formation de ces cristaux et la production de l'IL-6. Tout récemment, nous avons trouvé que des inhibiteurs de la xanthine oxidoréductase étaient aussi capables d'inhiber à la fois la production d'IL-6 et la minéralization des chondrocytes. Finalement, nous avons pu exclure un rôle du système IL-1 dans le modèle d'arthrose induite par ménisectomie, les souris déficientes pour IL-1a/ß, MyD88 et l'inflammasome NLRP3 n'étant pas protégées dans ce modèle d'arthrose. L'ensemble de nos résultats montre que les cristaux BCP sont pathogéniques dans l'arthrose et qu'un inhibiteur de minéralisation tel que le STS ou un inhibiteur de l'interleukine-6 constitueraient des nouvelles thérapies pour l'arthrose. -- Osteoarthritis (OA), the most common degenerative disorder of the joints, results from an imbalance between the breakdown and repair of the cartilage and surrounding articular structures. Joint calcification (essentially due to basic calcium phosphate (BCP) crystal deposition) is a characteristic feature of OA. However, the role of BCP crystal deposition in the pathogenesis of OA remains unclear[1][1]. We first demonstrated that in primary murine chondrocytes exogenous BCP crystals led to IL-6 up-modulation and that BCP crystal signaling pathways involved Syk and PI3 kinases, and also gp130 associated molecules, Jak2 and Stat3. BCP crystals also induced proteoglycan loss and IL-6 expression in human cartilage expiants, (which were significantly reduced by an IL-6 inhibitor). In addition, we found that in chondrocytes exogenous IL-6 promoted calcium-containing crystal formation and up- regulation of genes codifying for proteins involved in the calcification process: the inorganic pyrophosphate transport channel Ank, the calcium channel Annexinö and the sodium/phosphate cotransporter Piti. In vivo, BCP crystals injected into murine knee joints induced cartilage erosion. In the menisectomy model, increasing deposits, identified as BCP crystals, were progressively observed around the joint before cartilage erosion. These deposits strongly correlated with cartilage degradation and IL-6 expression. These results demonstrated that BCP crystals deposition and IL-6 production are mutually reinforcing in the osteoarthritic pathogenic process. We then investigated if we could block the BCP-IL6 loop by either targeting IL-6 production or BCP crystal deposits. Treatment of chondrocytes with anti-IL-6 antibodies or inhibitors of IL-6- signaling pathway significantly inhibited IL-6-induced crystal formation. Similarly, sodium thiosulfate (STS), a well-known systemic calcification inhibitor, decreased crystal deposition as well as HA-induced IL-6 secretion in chondrocytes and, in vivo, it decreased crystal deposits size and cartilage erosion in menisectomized knees. Interestingly, we also found that xanthine-oxidoreductase (XO) inhibitors inhibited both IL-6 production and calcium crystal depositis in chondrocytes. We began to unravel the mechanisms involved in this coordinate modulation of IL-6 and mineralization. STS inhibited Reactive Oxygen Species (ROS) generation and we are currently investigating whether XO represents a major source of ROS in chondrocyte mineralization. Finally, we ruled out that IL-1 activation/signaling plays a role in the murine model of OA induced by menisectomy, as IL-1a/ß, the IL-1 R associated molecule MyD88 and NLRP3 inflammasome deficient mice were not protected in this model of OA. Moreover TLR-1, -2, -4,-6 deficient mice had a phenotype similar to that of wild-type mice. Altogether our results demonstrated a self-amplification loop between BCP crystals deposition and IL-6 production, which represents an aggravating process in OA pathogenesis. As currently prescribed OA drugs are addressing OA symptoms,our results highlight a potential novel treatment strategy whereby inhibitors of calcium- containing crystal formation and IL-6 could be combined to form the basis of a disease modifying treatment and alter the course of OA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure