940 resultados para Catheter Ablation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hibernation patterns were monitored continuously for 2.5 years in female squirrels that were neurologically intact or in which the hypothalamic suprachiasmatic nucleus (SCN) was completely ablated (SCNx). The number of hibernation bouts in SCNx squirrels increased by 159%, total hibernation time increased by 58%, and periodic arousals from hibernation were 47% longer in SCNx than in control squirrels; the duration of individual torpor bouts was 2 days shorter and far more variable in SCNx than in control animals. Some SCNx squirrels cycled through bouts of torpor continuously for nearly 2 years. The SCN appears to be part of the mechanism that controls the duration of the hibernation season and the temporal structure of individual torpor bouts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Localization of the central rhythm generator (CRG) of spontaneous consummatory licking was studied in freely moving rats by microinjection of tetrodotoxin (TTX) into the pontine reticular formation. Maximum suppression of spontaneous water consumption was elicited by TTX (1 ng) blockade of the oral part of the nucleus reticularis gigantocellularis (NRG), whereas TTX injections into more caudal or rostral locations caused significantly weaker disruption of drinking. To verify the assumption that TTX blocked the proper CRG of licking rather than some relay in its output, spontaneously drinking thirsty rats were intracranially stimulated via electrodes chronically implanted into the oral part of the NRG. Lick-synchronized stimulation (a 100-ms train of 0.1-ms-wide rectangular pulses at 100 Hz and 25-150 microA) applied during continuous licking (after eight regular consecutive licks) caused a phase shift of licks emitted after stimulus delivery. The results suggest that the stimulation has reset the CRG of licking without changing its frequency. The reset-inducing threshold current was lowest during the tongue retraction and highest during the tongue protrusion period of the lick cycle. It is concluded that the CRG of licking is located in the oral part of NRG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gastric mucosa of mammalian stomach contains several differentiated cell types specialized for the secretion of acid, digestive enzymes, mucus, and hormones. Understanding whether each of these cell lineages is derived from a common stem cell has been a challenging problem. We have used a genetic approach to analyze the ontogeny of progenitor cells within mouse stomach. Herpes simplex virus 1 thymidine kinase was targeted to parietal cells within the gastric mucosa of transgenic mice, and parietal cells were ablated by treatment of animals with the antiherpetic drug ganciclovir. Ganciclovir treatment produced complete ablation of parietal cells, dissolution of gastric glands, and loss of chief and mucus-producing cells. Termination of drug treatment led to the reemergence of all major gastric epithelial cell types and restoration of glandular architecture. Our results imply the existence of a pluripotent stem cell for the gastric mucosa. Parietal cell ablation should provide a model for analyzing cell lineage relationships within the stomach as well as mechanisms underlying gastric injury and repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Surveillance programmes have become the most effective tool for controlling catheter-related bloodstream infections (CRBSI). However, few studies have investigated programmes covering all hospital settings. Aim: To describe the results of a control and prevention programme for CRBSI based on compliance with recommendations for insertion and maintenance, using annual burden of disease in a tertiary level hospital. Methods: A CRBSI control and prevention programme involving all hospital settings was implemented. The programme consisted of CRBSI surveillance, direct observation of insertion and maintenance of catheters to determine performance, and education for healthcare workers. Findings: In total, 2043 short-term catheters were inserted in 1546 patients for 18,570 catheter-days, and 279 long-term catheters were inserted in 243 patients for 40,440 catheter-days. The annual incidence density was 5.98 (first semester 6.40, second semester 5.64) CRBSI per 1000 catheter-days for short-term catheters, and 0.57 (first semester 0.66, second semester 0.43) CRBSI per 1000 catheter-days for long-term catheters. One hundred and forty insertion procedures were observed, with an average insertion time of 13 (standard deviation 7) min. Compliance with recommendations was as follows: hand hygiene, 86.8%; use of alcoholic chlorhexidine solution for skin disinfection, 35.5%; use of mask, 93.4%; use of gloves, 98.7%; use of gown, 75.0%; use of sterile cloth, 93.8%; use of cap, 92.2%; bandage application, 62.7%; and use of aseptic technique, 89.5%. Forty-five maintenance procedures were observed, and compliance rates were as follows: hand hygiene, 42.1%; use of gloves, 78.1%; and port disinfection with alcoholic chlorhexidine solution, 32.5%. Conclusion: The CRBSI control and prevention programme implemented at the study hospital has decreased the rate of CRBSI, provided important information about the total burden of disease, and revealed possible ways to improve interventions in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Radiofrequency ablation (RFA) from the epicardial space for ventricular arrhythmias is limited or impossible in some cases. Reasons for epicardial ablation failure and the effect on outcome have not been systematically analyzed. METHODS AND RESULTS We assessed reasons for epicardial RFA failure relative to the anatomic target area and the type of heart disease and assessed the effect of failed epicardial RFA on outcome after ablation procedures for ventricular arrhythmias in a large single-center cohort. Epicardial access was attempted during 309 ablation procedures in 277 patients and was achieved in 291 procedures (94%). Unlimited ablation in an identified target region could be performed in 181 cases (59%), limited ablation was possible in 22 cases (7%), and epicardial ablation was deemed not feasible in 88 cases (28%). Reasons for failed or limited ablation were unsuccessful epicardial access (6%), failure to identify an epicardial target (15%), proximity to a coronary artery (13%), proximity to the phrenic nerve (6%), and complications (<1%). Epicardial RFA was impeded in the majority of cases targeting the left ventricular summit region. Acute complications occurred in 9%. The risk for acute ablation failure was 8.3× higher (4.5-15.0; P<0.001) after no or limited epicardial RFA compared with unlimited RFA, and patients with unlimited epicardial RFA had better recurrence-free survival rates (P<0.001). CONCLUSIONS Epicardial RFA for ventricular arrhythmias is often limited even when pericardial access is successful. Variability of success is dependent on the target area, and the presence of factors limiting ablation is associated with worse outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performing organization (under Contract or Grant no. F33615-71-C-1215): Aerotherm Division/Acurex Corporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Preprint copy."