916 resultados para CHRONIC HEART-FAILURE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To consensually validate the operational definitions of the nursing diagnoses activity intolerance, excessive fluid volume, and decreased cardiac output in patients with decompensated heart failure. Method Consensual validation was performed in two stages: analogy by similarity of defining characteristics, and development of operational definitions and validation with experts. Results A total of 38 defining characteristics were found. Operational definitions were developed and content-validated. One hundred percent of agreement was achieved among the seven experts after five rounds. Ascites was added in the nursing diagnosis excessive fluid volume. Conclusion The consensual validation improves interpretation of human response, grounding the selection of nursing interventions and contributing to improved nursing outcomes. Implications for Practice Support the assessment of patients with decompensated heart failure. Objetivos Realizar a validacAo consensual das definicoes operacionais dos diagnosticos de enfermagem Intolerancia a atividade, Volume de liquidos excessivo e Debito cardiaco diminuido em pacientes com insuficiencia cardiaca descompensada. Metodo ValidacAo consensual em duas etapas: Analogia de semelhanca das caracteristicas definidoras e desenvolvimento de definicoes operacionais e validacAo com expertst. Resultados Foram encontradas 38 caracteristicas definidoras para os diagnosticos de enfermagem. Suas definicoes operacionais foram desenvolvidas e seu conteudo validado. Os resultados mostram que houve 100% de concordancia entre os sete experts apos cinco rodada. As definicoes operacionais foram classificadas com base no nivel de concordanica. Ascite foi acrescentada ao diagnostico Volume de liquidos excessivo. ConclusAo A validacAo consensual melhora a interpretacAo das respostas humanas, embasando a selecAo de intervencoes de enfermagem e contribuindo para melhorar os resultados. Implicacoes Para A Pratica Apoio a avaliacAo dos pacientes com insuficiencia cardiaca descompensada.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Studies have investigated the influence of neuromuscular electrostimulation on the exercise/muscle capacity of patients with heart failure (HF), but the hemodynamic overload has never been investigated. The aim of our study was to evaluate the heart rate (HR), systolic and diastolic blood pressures in one session of strength exercises with and without neuromuscular electrostimulation (quadriceps) in HF patients and in healthy subjects. Methods: Ten (50% male) HF patients and healthy subjects performed three sets of eight repetitions with and without neuromuscular electrostimulation randomly, with one week between sessions. Throughout, electromyography was performed to guarantee the electrostimulation was effective. The hemodynamic variables were measured at rest, again immediately after the end of each set of exercises, and during the recovery period. Results: Systolic and diastolic blood pressures did not change during each set of exercises among either the HF patients or the controls. Without electrostimulation: among the controls, the HR corresponding to the first (85 ± 13 bpm, p = 0.002), second (84 ± 10 bpm, p < 0.001), third (89 ± 17, p < 0.001) sets and recuperation (83 ± 16 bpm, p = 0.012) were different compared to the resting HR (77 bpm). Moreover, the recuperation was different to the third set (0.018). Among HF patients, the HR corresponding to the first (84 ± 9 bpm, p = 0.041) and third (84 ± 10 bpm, p = 0.036) sets were different compared to the resting HR (80 ± 7 bpm), but this increase of 4 bpm is clinically irrelevant to HF. With electrostimulation: among the controls, the HR corresponding to the third set (84 ± 9 bpm) was different compared to the resting HR (80 ± 7 bmp, p = 0.016). Among HF patients, there were no statistical differences between the sets. The procedure was well tolerated and no subjects reported muscle pain after 24 hours. Conclusions: One session of strength exercises with and without neuromuscular electrostimulation does not promote a hemodynamic overload in HF patients. (Cardiol J 2011; 18, 1: 39-46)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)