994 resultados para CE-merkintä
Resumo:
A review about the state-of-the-art of flow injection analysis (FIA) -- capillary electrophoresis (CE) systems is presented. The basic principles of flow injection and capillary electrophoresis are briefly revised. The main aspects of the FIA-CE hybridization, including advantages and shortcomings, are discussed. Some applications involving all different designs are also presented. This review covers the literature from 1997 up to 2000.
Resumo:
El artículo tiene como objetivo analizar el modelo social incorporado en la Directiva 2004/38/CE en el marco de la jurisprudencia del Tribunal de Justicia. El artículo está dividido en dos partes. En la primera se describe la evolución del modelo de coordinación social de la Unión Europea y los avances propuestos por el TJCE a partir de la ciudadanía europea sobre el acceso a las prestaciones sociales (Martínez Sala, Grzelczyk y Collins). La segunda parte del artículo describe el modelo social incorporado en la Directiva 2004/38/ CE y los cambios que éste supuso para la jurisprudencia que venía dictando el TJCE. El artículo concluye que la Directiva 2004/38/CE tuvo un papel de contención frente los pasos dados por el Tribunal para incluir los derechos sociales en la ciudadanía de la Unión; además, la Directiva fragmentó la interpretación del principio de no discriminación para los ciudadanos no económicamente activos.
Resumo:
An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.
Resumo:
Simulations have been carried out on the bromate - oxalic acid - Ce(IV) - acetone oscillating reaction, under flow conditions, using Field and Boyd's model (J. Phys. Chem. 1985, 89, 3707). Many different complex dynamic behaviors were found, including simple periodic oscillations, complex periodic oscillations, quasiperiodicity and chaos. Some of these complex oscillations can be understood as belonging to a Farey sequence. The many different behaviors were systematized in a phase diagram which shows that some regions of complex patterns were nested with one inside the other. The existence of almost all known dynamic behavior for this system allows the suggestion that it can be used as a model for some very complex phenomena that occur in biological systems.
Resumo:
CE-MS has been increasingly used for analysis of a vast array of compounds. This article reviews the different electrophoretic modes, interfaces and mass analyzers that are commonly used in the CE-MS coupling, as well as the technique advantages and performance characteristics. A large compilation of CE-MS applications is also presented. Therefore, this review is both a guide for beginners and a collection of key references for people who are familiar to the technique. Furthermore, this is the first CE-MS review published in a Brazilian journal and marks the installation of the first two commercial CE-MS units in Sao Paulo State.
Resumo:
Capillary electrophoresis has become a well-established and routine-based separation technique. It is based on the differences between charged analyte mobility in aqueous or organic electrolytes. Its major limitation is the sensitivity due to small sample injection volumes and the narrow diameter of the capillaries, especially when UV detection is used. There are a number of ways to increase the concentration sensitivity. This report shows some on-line preconcentration strategies to perform it in free solution capillary electrophoresis that are based on manipulation of the analyte electrophoretic velocity during the sample introduction (stacking, field amplification and transient isotachophoresis).
Resumo:
A capillary electrophoresis (CE) method was developed and validated for determination of cetirizine dihydrochloride in tablets and compounded capsules. The electrophoretic separation was performed in an uncoated fused-silica capillary (40 cm x 50 μm i.d.) using 20 mmol L-1 sodium tetraborate buffer (pH 9.3) as background electrolyte, a hydrodinamic sample injection at 50 mBar for 5 s, 20 KV applied voltage at 25 °C, and detection at 232 nm. The proposed method was compared with the high performance liquid chromatographic (HPLC) method previously validated for this drug, and statistical analysis showed no significant difference between the techniques.
Resumo:
Arkit: 1 arkintunnukseton lehti, A4 C2.
Resumo:
Ce-promoted Ni-catalysts from hydrotalcites were obtained. The effect of calcination temperature on the chemical and physical properties of the catalysts was studied. Several techniques were used to determine the chemical and physical characteristics of oxides. The apparent activation energies of reduction were determined. Catalytic experiments at 48 L g-1h-1 without pre-reduction in CO2 reforming of methane were performed. The spinel-like phase in these oxides was only formed at 1000 ºC. The reduction of Ni2+ in the oxides was clearly affected by the calcination temperature which was correlated with catalytic performance. The catalyst calcined at 700 ºC showed the greatest activity.
Resumo:
A preliminary study was conducted to determine the residue levels of prochloraz in ginger samples treated with Sportak 450 CE® (prochloraz as active ingredient) under laboratory conditions and cold-storage for 15 days at 10°C and 89% RH. Sampling was carried out at 10 and 15 days after Sportak 450 CE® dip treatment (450 and 900 µg mL-1). Pesticide residues were determined by GCECD. During the study, residue levels in ginger ranged between 3.6 and 10.6 mg Kg-1 for prochloraz.
Resumo:
Soitinnus: piano.
Resumo:
kuv., 9 x 12 cm
Resumo:
OBJETIVO: Verificar a associação entre complicações maternas e tipo de parto em gestantes cardiopatas, assim como identificar os possíveis fatores clínicos e obstétricos, implicados na determinação da via de parto. MÉTODOS: Estudo retrospectivo e descritivo analisando prontuários médicos das gestantes cardiopatas internadas em Hospital de Referência terciário no município de Fortaleza, Ceará, no período de 2006 a 2007. A população do estudo incluiu todas as gestantes com diagnóstico anteparto de cardiopatias admitidas para realização do parto e excluiu as gestantes que tiveram o diagnóstico de cardiopatia após o parto, independente da idade e semana gestacional. Utilizou-se um questionário semiestruturado com variáveis demográficas, clínicas e obstétricas. Realizou-se, inicialmente, uma análise descritiva por meio de frequências simples e proporções das variáveis sociodemográficas, clínicas e obstétricas. Em seguida foram analisadas possíveis associações entre os aspectos clínicos, obstétricos e tipo de parto, verificando associação entre complicações maternas e tipo de parto. Para isso, foi aplicado o teste Exato de Fischer, considerando p<0,05 para o estabelecimento da significância estatística. Os dados coletados foram processados e analisados utilizando o software Epi-InfoTM, versão 6.04, Atlanta, USA. RESULTADOS: Foram incluídas 73 gestantes cardiopatas. Dentre as congênitas, a comunicação interatrial foi a mais observada (11,0%) e entre as adquiridas, a estone mitral a mais freqüente (24,6%). A proporção de partos cesáreos foi maior do que entre os vaginais, exceto para mulheres com cardiopatia adquirida. Foi encontrada associação entre tipo de cardiopatia e tipo de parto (p=0,01). Houve 13 complicações maternas (17,8%). Dentre as complicações, dez (76,9%) ocorreram por parto cesáreo e três por via vaginal. Não foi encontrada associação entre complicações maternas e tipo de parto em gestantes cardiopatas (p=0,74). CONCLUSÕES: Não houve associação entre a ocorrência de complicações maternas e a via de parto em gestantes cardiopatas.