874 resultados para Automated Hazard Analysis
Resumo:
BACKGROUND: Published work assessing psychosocial stress (job strain) as a risk factor for coronary heart disease is inconsistent and subject to publication bias and reverse causation bias. We analysed the relation between job strain and coronary heart disease with a meta-analysis of published and unpublished studies. METHODS: We used individual records from 13 European cohort studies (1985-2006) of men and women without coronary heart disease who were employed at time of baseline assessment. We measured job strain with questions from validated job-content and demand-control questionnaires. We extracted data in two stages such that acquisition and harmonisation of job strain measure and covariables occurred before linkage to records for coronary heart disease. We defined incident coronary heart disease as the first non-fatal myocardial infarction or coronary death. FINDINGS: 30?214 (15%) of 197?473 participants reported job strain. In 1·49 million person-years at risk (mean follow-up 7·5 years [SD 1·7]), we recorded 2358 events of incident coronary heart disease. After adjustment for sex and age, the hazard ratio for job strain versus no job strain was 1·23 (95% CI 1·10-1·37). This effect estimate was higher in published (1·43, 1·15-1·77) than unpublished (1·16, 1·02-1·32) studies. Hazard ratios were likewise raised in analyses addressing reverse causality by exclusion of events of coronary heart disease that occurred in the first 3 years (1·31, 1·15-1·48) and 5 years (1·30, 1·13-1·50) of follow-up. We noted an association between job strain and coronary heart disease for sex, age groups, socioeconomic strata, and region, and after adjustments for socioeconomic status, and lifestyle and conventional risk factors. The population attributable risk for job strain was 3·4%. INTERPRETATION: Our findings suggest that prevention of workplace stress might decrease disease incidence; however, this strategy would have a much smaller effect than would tackling of standard risk factors, such as smoking. FUNDING: Finnish Work Environment Fund, the Academy of Finland, the Swedish Research Council for Working Life and Social Research, the German Social Accident Insurance, the Danish National Research Centre for the Working Environment, the BUPA Foundation, the Ministry of Social Affairs and Employment, the Medical Research Council, the Wellcome Trust, and the US National Institutes of Health.
Resumo:
OBJECTIVE: To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorithm in a defibrillator determine rapidly circulatory arrest and facilitate prompt initiation of external cardiac massage?
DESIGN: Clinical study.
SETTING: University hospital.
PATIENTS: Phase 1 patients attended for myocardial perfusion imaging. Phase 2 patients were recruited during cardiac arrest. This group included nonarrest controls.
INTERVENTIONS: The impedance cardiogram was recorded through defibrillator/electrocardiographic pads oriented in the standard cardiac arrest position.
MEASUREMENTS AND MAIN RESULTS: Phase 1: Stroke volumes from gated myocardial perfusion imaging scans were correlated with parameters from the impedance cardiogram system (dZ/dt(max) and the peak amplitude of the Fast Fourier Transform of dZ/dt between 1.5 Hz and 4.5 Hz). Multivariate analysis was performed to fit stroke volumes from gated myocardial perfusion imaging scans with linear and quadratic terms for dZ/dt(max) and the Fast Fourier Transform to identify significant parameters for incorporation into a cardiac arrest diagnostic algorithm. The square of the peak amplitude of the Fast Fourier Transform of dZ/dt was the best predictor of reduction in stroke volumes from gated myocardial perfusion imaging scans (range = 33-85 mL; p = .016). Having established that the two pad impedance cardiogram system could detect differences in stroke volumes from gated myocardial perfusion imaging scans, we assessed its performance in diagnosing cardiac arrest. Phase 2: The impedance cardiogram was recorded in 132 "cardiac arrest" patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with sensitivities and specificities (+/- exact 95% confidence intervals) of 89.1% (85.4-92.1) and 99.6% (99.4-99.7; training) and 81.1% (77.6-84.3) and 97% (96.7-97.4; validation).
CONCLUSIONS: The impedance cardiogram algorithm is a significant marker of circulatory collapse. Automated defibrillators with an integrated impedance cardiogram could improve emergency care by lay persons, enabling rapid and appropriate initiation of external cardiac massage.
Resumo:
PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).
METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.
RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.
CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.
Resumo:
Reagent pre-storage in a microfluidic chip can enhance operator convenience, simplify the system design, reduce the cost of storage and shipment, and avoid the risk of cross-contamination. Although dry reagents have long been used in lateral flow immunoassays, they have rarely been used for nucleic acid-based point-of-care (POC) assays due to the lack of reliable techniques to dehydrate and store fragile molecules involved in the reaction. In this study, we describe a simple and efficient method for prolonged on-chip storage of PCR reagents. The method is based on gelification of all reagents required for PCR as a ready-to-use product. The approach was successfully implemented in a lab-on-a-foil system, and the gelification process was automated for mass production. Integration of reagents on-chip by gelification greatly facilitated the development of easy-to-use lab-on-a-chip (LOC) devices for fast and cost-effective POC analysis.
Resumo:
A novel multiplexed immunoassay for the analysis of phycotoxins in shellfish samples has been developed. Therefore, a regenerable chemiluminescence (CL) microarray was established which is able to analyze automatically three different phycotoxins (domoic acid (DA), okadaic acid (OA) and saxitoxin (STX)) in parallel on the analysis platform MCR3. As a test format an indirect competitive immunoassay format was applied. These phycotoxins were directly immobilized on an epoxy-activated PEG chip surface. The parallel analysis was enabled by the simultaneous addition of all analytes and specific antibodies on one microarray chip. After the competitive reaction, the CL signal was recorded by a CCD camera. Due to the ability to regenerate the toxin microarray, internal calibrations of phycotoxins in parallel were performed using the same microarray chip, which was suitable for 25 consecutive measurements. For the three target phycotoxins multi-analyte calibration curves were generated. In extracted shellfish matrix, the determined LODs for DA, OA and STX with values of 0.5±0.3 µg L(-1), 1.0±0.6 µg L(-1), and 0.4±0.2 µg L(-1) were slightly lower than in PBS buffer. For determination of toxin recoveries, the observed signal loss in the regeneration was corrected. After applying mathematical corrections spiked shellfish samples were quantified with recoveries for DA, OA, and STX of 86.2%, 102.5%, and 61.6%, respectively, in 20 min. This is the first demonstration of an antibody based phycotoxin microarray.
Resumo:
There is a requirement for better integration between design and analysis tools, which is difficult due to their different objectives, separate data representations and workflows. Currently, substantial effort is required to produce a suitable analysis model from design geometry. Robust links are required between these different representations to enable analysis attributes to be transferred between different design and analysis packages for models at various levels of fidelity.
This paper describes a novel approach for integrating design and analysis models by identifying and managing the relationships between the different representations. Three key technologies, Cellular Modeling, Virtual Topology and Equivalencing, have been employed to achieve effective simulation model management. These technologies and their implementation are discussed in detail. Prototype automated tools are introduced demonstrating how multiple simulation models can be linked and maintained to facilitate seamless integration throughout the design cycle.
Resumo:
Background: Many patients and healthcare professionals believe that work-related psychosocial stress, such as job strain, can make asthma worse, but this is not corroborated by empirical evidence. We investigated the associations between job strain and the incidence of severe asthma exacerbations in working-age European men and women. Methods: We analysed individual-level data, collected between 1985 and 2010, from 102 175 working-age men and women in 11 prospective European studies. Job strain (a combination of high demands and low control at work) was self-reported at baseline. Incident severe asthma exacerbations were ascertained from national hospitalization and death registries. Associations between job strain and asthma exacerbations were modelled using Cox regression and the study-specific findings combined using random-effects meta-analyses. Results: During a median follow-up of 10 years, 1 109 individuals experienced a severe asthma exacerbation (430 with asthma as the primary diagnostic code). In the age- and sex-adjusted analyses, job strain was associated with an increased risk of severe asthma exacerbations defined using the primary diagnostic code (hazard ratio, HR: 1.27, 95% confidence interval, CI: 1.00, 1.61). This association attenuated towards the null after adjustment for potential confounders (HR: 1.22, 95% CI: 0.96, 1.55). No association was observed in the analyses with asthma defined using any diagnostic code (HR: 1.01, 95% CI: 0.86, 1.19). Conclusions: Our findings suggest that job strain is probably not an important risk factor for severe asthma exacerbations leading to hospitalization or death.
Resumo:
An algorithm based only on the impedance cardiogram (ICG) recorded through two defibrillation pads, using the strongest frequency component and amplitude, incorporated into a defibrillator could determine circulatory arrest and reduce delays in starting cardiopulmonary resuscitation (CPR). Frequency analysis of the ICG signal is carried out by integer filters on a sample by sample basis. They are simpler, lighter and more versatile when compared to the FFT. This alternative approach, although less accurate, is preferred due to the limited processing capacity of devices that could compromise real time usability of the FFT. These two techniques were compared across a data set comprising 13 cases of cardiac arrest and 6 normal controls. The best filters were refined on this training set and an algorithm for the detection of cardiac arrest was trained on a wider data set. The algorithm was finally tested on a validation set. The ICG was recorded in 132 cardiac arrest patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with a sensitivity of 81.1% (77.6-84.3) and specificity of 97.1% (96.7-97.4) for the validation set (95% confidence intervals). Automated defibrillators with integrated ICG analysis have the potential to improve emergency care by lay persons enabling more rapid and appropriate initiation of CPR and when combined with ECG analysis they could improve on the detection of cardiac arrest.
Resumo:
In this paper we propose a novel automated glaucoma detection framework for mass-screening that operates on inexpensive retinal cameras. The proposed methodology is based on the assumption that discriminative features for glaucoma diagnosis can be extracted from the optical nerve head structures,
such as the cup-to-disc ratio or the neuro-retinal rim variation. After automatically segmenting the cup and optical disc, these features are feed into a machine learning classifier. Experiments were performed using two different datasets and from the obtained results the proposed technique provides
better performance than approaches based on appearance. A main advantage of our approach is that it only requires a few training samples to provide high accuracy over several different glaucoma stages.
Resumo:
Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.
Resumo:
Background: Primary results from the phase 3 ALSYMPCA trial showed that radium-223 dichloride (radium-223), a targeted α-emitter, improved overall survival compared with placebo and was well tolerated in patients with castration-resistant prostate cancer and symptomatic bone metastases. We did a prespecified subgroup analysis from ALSYMPCA to assess the effect of previous docetaxel use on the efficacy and safety of radium-223.
Methods: In the phase 3, randomised, double-blind ALSYMPCA trial, patients with symptomatic castration-resistant prostate cancer, at least two symptomatic bone metastases, no known visceral metastases, and who were receiving best standard of care were randomly assigned (2:1) via an interactive voice response system to receive six injections of radium-223 (50 kBq/kg intravenously) or matching placebo, with one injection given every 4 weeks. Patients had either received previous docetaxel treatment or were unsuitable for or declined docetaxel; previous docetaxel use (yes or no) was a trial stratification factor. We investigated the effect of previous docetaxel use on radium-223 treatment for the primary endpoint of overall survival, the main secondary efficacy endpoints, and safety. Efficacy analyses were done for the intention-to-treat population; safety analyses were done for the safety population. The trial has been completed and is registered with ClinicalTrials.gov, number NCT00699751.
Findings: Randomisation took place between June 12, 2008, and Feb 1, 2011. 526 (57%) of 921 randomly assigned patients had received previous docetaxel treatment (352 in the radium-223 group and 174 in the placebo group) and 395 (43%) had not (262 in the radium-223 group and 133 in the placebo group). Radium-223 prolonged median overall survival compared with placebo, irrespective of previous docetaxel use (previous docetaxel use, hazard ratio [HR] 0·70, 95% CI 0·56-0·88; p=0·002; no previous docetaxel use, HR 0·69, 0·52-0·92; p=0·01). The benefit of radium-223 compared with placebo was seen in both docetaxel subgroups for most main secondary efficacy endpoints; risk for time to time to first symptomatic skeletal event was reduced with radium-223 versus placebo in patients with previous docetaxel use, but the difference was not significant in those with no previous docetaxel use. 322 (62%) of 518 patients previously treated with docetaxel had grade 3-4 adverse events, compared with 205 (54%) of 383 patients without docetaxel. Patients who had previously been treated with docetaxel had a higher incidence of grade 3-4 thrombocytopenia with radium-223 than with placebo (31 [9%] of 347 patients vs five [3%] of 171 patients), whereas the incidence was similar between treatment groups among patients with no previous docetaxel use (seven [3%] of 253 patients vs one [1%] of 130 patients). The incidences of grade 3-4 anaemia and neutropenia were similar between the radium-223 and placebo groups within both docetaxel subgroups.
Interpretation: Radium-223 is effective and well tolerated in patients with castration-resistant prostate cancer and symptomatic bone metastases, irrespective of previous docetaxel use.
Funding: Algeta ASA and Bayer HealthCare Pharmaceuticals.
Resumo:
This paper outlines the importance of robust interface management for facilitating finite element analysis workflows. Topological equivalences between analysis model representations are identified and maintained in an editable and accessible manner. The model and its interfaces are automatically represented using an analysis-specific cellular decomposition of the design space. Rework of boundary conditions following changes to the design geometry or the analysis idealization can be minimized by tracking interface dependencies. Utilizing this information with the Simulation Intent specified by an analyst, automated decisions can be made to process the interface information required to rebuild analysis models. Through this work automated boundary condition application is realized within multi-component, multi-resolution and multi-fidelity analysis workflows.
Resumo:
BACKGROUND: The prevalence of obesity is increasing globally and is associated with chronic kidney disease and premature mortality. However, the impact of recipient obesity on kidney transplant outcomes remains unclear. This study aimed to investigate the association between recipient obesity and mortality, death-censored graft loss and delayed graft function (DGF) following kidney transplantation.
METHODS: A systematic review and meta-analysis was conducted using Medline, Embase and the Cochrane Library. Observational studies or randomized controlled trials investigating the association between recipient obesity at transplantation and mortality, death-censored graft loss and DGF were included. Obesity was defined as a body mass index (BMI) of ≥30 kg/m(2). Obese recipients were compared with those with a normal BMI (18.5-24.9 kg/m(2)). Pooled estimates of hazard ratios (HRs) for patient mortality or death-censored graft loss and odds ratios (ORs) for DGF were calculated.
RESULTS: Seventeen studies including 138 081 patients were analysed. After adjustment, there was no significant difference in mortality risk in obese recipients [HR = 1.24, 95% confidence interval (CI) = 0.90-1.70, studies = 5, n = 83 416]. However, obesity was associated with an increased risk of death-censored graft loss (HR = 1.06, 95% CI = 1.01-1.12, studies = 5, n = 83 416) and an increased likelihood of DGF (OR = 1.68, 95% CI = 1.39-2.03, studies = 4, n = 28 847).
CONCLUSIONS: Despite having a much higher likelihood of DGF, obese transplant recipients have only a slightly increased risk of graft loss and experience similar survival to recipients with normal BMI.
Resumo:
OBJECTIVE: To investigate the impact of smoking and smoking cessation on cardiovascular mortality, acute coronary events, and stroke events in people aged 60 and older, and to calculate and report risk advancement periods for cardiovascular mortality in addition to traditional epidemiological relative risk measures.
DESIGN: Individual participant meta-analysis using data from 25 cohorts participating in the CHANCES consortium. Data were harmonised, analysed separately employing Cox proportional hazard regression models, and combined by meta-analysis.
RESULTS: Overall, 503,905 participants aged 60 and older were included in this study, of whom 37,952 died from cardiovascular disease. Random effects meta-analysis of the association of smoking status with cardiovascular mortality yielded a summary hazard ratio of 2.07 (95% CI 1.82 to 2.36) for current smokers and 1.37 (1.25 to 1.49) for former smokers compared with never smokers. Corresponding summary estimates for risk advancement periods were 5.50 years (4.25 to 6.75) for current smokers and 2.16 years (1.38 to 2.39) for former smokers. The excess risk in smokers increased with cigarette consumption in a dose-response manner, and decreased continuously with time since smoking cessation in former smokers. Relative risk estimates for acute coronary events and for stroke events were somewhat lower than for cardiovascular mortality, but patterns were similar.
CONCLUSIONS: Our study corroborates and expands evidence from previous studies in showing that smoking is a strong independent risk factor of cardiovascular events and mortality even at older age, advancing cardiovascular mortality by more than five years, and demonstrating that smoking cessation in these age groups is still beneficial in reducing the excess risk.