911 resultados para Automated Guideway Transit (AGT)
Resumo:
This study aimed to evaluate whether equine serum amyloid A (SAA) concentrations could be reliably measured in plasma with a turbidimetric immunoassay previously validated for equine SAA concentrations in serum. Paired serum and lithium-heparin samples obtained from 40 horses were evaluated. No difference was found in SAA concentrations between serum and plasma using a paired t test (P=0.48). The correlation between paired samples was 0.97 (Spearman's rank P<0.0001; 95% confidence interval 0.95-0.99). Passing-Bablok regression analyses revealed no differences between paired samples. Bland-Altman plots revealed a positive bias in plasma compared to serum but the difference was not considered clinically significant. The results indicate that lithium-heparin plasma samples are suitable for measurement of equine SAA using this method. Use of either serum or plasma allows for greater flexibility when it comes to sample collection although care should be taken when comparing data between measurements from different sample types.
Resumo:
The successful management of cancer with radiation relies on the accurate deposition of a prescribed dose to a prescribed anatomical volume within the patient. Treatment set-up errors are inevitable because the alignment of field shaping devices with the patient must be repeated daily up to eighty times during the course of a fractionated radiotherapy treatment. With the invention of electronic portal imaging devices (EPIDs), patient's portal images can be visualized daily in real-time after only a small fraction of the radiation dose has been delivered to each treatment field. However, the accuracy of human visual evaluation of low-contrast portal images has been found to be inadequate. The goal of this research is to develop automated image analysis tools to detect both treatment field shape errors and patient anatomy placement errors with an EPID. A moments method has been developed to align treatment field images to compensate for lack of repositioning precision of the image detector. A figure of merit has also been established to verify the shape and rotation of the treatment fields. Following proper alignment of treatment field boundaries, a cross-correlation method has been developed to detect shifts of the patient's anatomy relative to the treatment field boundary. Phantom studies showed that the moments method aligned the radiation fields to within 0.5mm of translation and 0.5$\sp\circ$ of rotation and that the cross-correlation method aligned anatomical structures inside the radiation field to within 1 mm of translation and 1$\sp\circ$ of rotation. A new procedure of generating and using digitally reconstructed radiographs (DRRs) at megavoltage energies as reference images was also investigated. The procedure allowed a direct comparison between a designed treatment portal and the actual patient setup positions detected by an EPID. Phantom studies confirmed the feasibility of the methodology. Both the moments method and the cross-correlation technique were implemented within an experimental radiotherapy picture archival and communication system (RT-PACS) and were used clinically to evaluate the setup variability of two groups of cancer patients treated with and without an alpha-cradle immobilization aid. The tools developed in this project have proven to be very effective and have played an important role in detecting patient alignment errors and field-shape errors in treatment fields formed by a multileaf collimator (MLC). ^
Resumo:
BACKGROUND & AIMS: Refractory ascites (RA) affects 10% of patients with advanced cirrhosis and ascites. Usual therapy includes large volume paracentesis, and in selected patients, a transjugular portosystemic shunt (TIPS). These therapies may be associated with increased morbidity: paracentesis may induce circulatory dysfunction and impair quality of life and TIPS may induce encephalopathy and is associated with increased mortality in patients with severe liver dysfunction. We present the results of a multicenter, non-randomized trial to assess the safety and efficacy of a new automated pump system for treatment of RA. METHODS: Forty patients at 9 centers (February 2010-June 2011) received an implanted pump for the automated removal of ascites from the peritoneal cavity into the bladder, from where it was eliminated through normal urination. Patients were followed-up for 6months. The primary study outcome was safety. Secondary outcomes included recurrence of tense ascites and pump performance. RESULTS: Surgical complications occurred early in the study and became less frequent. The pump system removed 90% of the ascites and significantly reduced the median number of large volume paracentesis per month [3.4 (range 1-6) vs. 0.2 (range 0-4); p <0.01]. Cirrhosis-related adverse events decreased along follow-up. CONCLUSIONS: The automated pump seems an efficacious tool to move out ascites from the peritoneal cavity to the bladder. Its safety is still moderate, but a broad use in different countries will improve the surgical technique as well as the medical surveillance. A prospective randomized clinical trial vs. large volume paracentesis is underway to confirm these preliminary results.
Resumo:
This presentation is about young migrants’ journeys with low chances of receiving asylum or any other type of residence in Europe. These migrants exhibit a highly complex migration pattern. First, these migrants are frequently in durable “transit” across Europe, moving back and forth between different states. Second, transit migrants must exhibit a high degree of flexibility, as they have to respond to suddenly changing conditions, such as work opportunities, rejection of asylum claims, detention or deportation. Third, transit migrants often switch between different legal statuses, such as asylum seeker, rejected asylum seeker, illegal worker or detainee. This throws them into a general state of uncertainty and psychological distress. The experience of these young adults shows a deep ambivalence between a sense of autonomy, on the one hand, and of profound hope- and powerlessness, on the other. This presentation explores the “fragmented journeys” of these migrants, by way of a multi-sited ethnographic approach and biographical interviews. It focuses on the lived experiences and the strategies of irregular migrants to find a way to reside in Europe in the context of an increasingly restrictive migration management.
Resumo:
Manual counting of bacterial colony forming units (CFUs) on agar plates is laborious and error-prone. We therefore implemented a colony counting system with a novel segmentation algorithm to discriminate bacterial colonies from blood and other agar plates.A colony counter hardware was designed and a novel segmentation algorithm was written in MATLAB. In brief, pre-processing with Top-Hat-filtering to obtain a uniform background was followed by the segmentation step, during which the colony images were extracted from the blood agar and individual colonies were separated. A Bayes classifier was then applied to count the final number of bacterial colonies as some of the colonies could still be concatenated to form larger groups. To assess accuracy and performance of the colony counter, we tested automated colony counting of different agar plates with known CFU numbers of S. pneumoniae, P. aeruginosa and M. catarrhalis and showed excellent performance.
Resumo:
BACKGROUND Electrochemical conversion of xenobiotics has been shown to mimic human phase I metabolism for a few compounds. MATERIALS & METHODS Twenty-one compounds were analyzed with a semiautomated electrochemical setup and mass spectrometry detection. RESULTS The system was able to mimic some metabolic pathways, such as oxygen gain, dealkylation and deiodination, but many of the expected and known metabolites were not produced. CONCLUSION Electrochemical conversion is a useful approach for the preparative synthesis of some types of metabolites, but as a screening method for unknown phase I metabolites, the method is, in our opinion, inferior to incubation with human liver microsomes and in vivo experiments with laboratory animals, for example.
Resumo:
BACKGROUND Multiple breath washout (MBW) derived Scond is an established index of ventilation inhomogeneity. Time-consuming post hoc calculations of the expirogram's slope of alveolar phase III (SIII) and the lack of available software hampered widespread application of Scond. METHODS Seventy-two school-aged children (45 with cystic fibrosis; CF) performed 3 nitrogen MBW. We tested a new automated algorithm for Scond analysis (Scondauto ) which comprised breath selection for SIII detection, calculation and reporting of test quality. We compared Scondauto to (i) standard Scond analysis (Scondmanual ) with manual breath selection and to (ii) pragmatic Scond analysis including all breaths (Scondall ). Primary outcomes were success rate and agreement between different Scond protocols, and Scond fitting quality (linear regression R(2) ). RESULTS Average Scondauto (0.06 for CF and 0.01 for controls) was not different from Scondmanual (0.06 for CF and 0.01 for controls) and showed comparable fitting quality (R(2) 0.53 for CF and 0.13 for controls vs. R(2) 0.54 for CF and 0.13 for controls). Scondall was similar in CF and controls but with inferior fitting quality compared to Scondauto and Scondmanual . CONCLUSIONS Automated Scond calculation is feasible and produces robust results comparable to the standard manual way of Scond calculation. This algorithm provides a valid, fast and objective tool for regular use, even in children. Pediatr Pulmonol. © 2014 Wiley Periodicals, Inc.
Resumo:
Located in the northeastern region of Italy, the Venetian Plain (VP) is a sedimentary basin containing an extensively exploited groundwater system. The northern part is characterised by a large undifferentiated phreatic aquifer constituted by coarse grain alluvial deposits and recharged by local rainfalls and discharges from the rivers Brenta and Piave. The southern plain is characterised by a series of aquitards and sandy aquifers forming a well-defined artesian multi-aquifer system. In order to determine origins, transit times and mixing proportions of different components in groundwater (GW), a multi tracer study (H, He/He, C, CFC, SF, Kr, Ar, Sr/Sr, O, H, cations, and anions) has been carried out in VP between the rivers Brenta and Piave. The geochemical pattern of GW allows a distinction of the different water origins in the system, in particular based on View the MathML source HCO3-,SO42-,Ca/Mg,NO3-, O, H. A radiogenic Sr signature clearly marks GW originated from the Brenta and Tertiary catchments. End-member analysis and geochemical modelling highlight the existence of a mixing process involving waters recharged from the Brenta and Piave rivers, from the phreatic aquifer and from another GW reservoirs characterised by very low mineralization. Noble gas excesses in respect to atmospheric equilibrium occur in all samples, particularly in the deeper aquifers of the Piave river, but also in phreatic water of the undifferentiated aquifers. He–H ages in the phreatic aquifer and in the shallower level of the multi-aquifer system indicate recharge times in the years 1970–2008. The progression of H–He ages with the distance from the recharge areas together with initial tritium concentration (H + Hetrit) imply an infiltration rate of about 1 km/y and the absence of older components in these GW. SF and Kr data corroborate these conclusions. H − He ages in the deeper artesian aquifers suggest a dilution process with older, tritium free waters. C Fontes–Garnier model ages of the old GW components range from 1 to 12 ka, yielding an apparent GW velocity of about 1–10 m/y. Increase of radiogenic He follows the progression of C ages. Ar, radiogenic He and C tracers yield model-dependent age-ranges in overall good agreement once diffusion of C from aquitards, GW dispersion, lithogenic Ar production, and He production-rate heterogeneities are taken into account. The rate of radiogenic He increase with time, deduced by comparison with C model ages, is however very low compared to other studies. Comparison with C and C data obtained 40 years ago on the same aquifer system shows that exploitation of GW caused a significant loss of the old groundwater reservoir during this time.
Resumo:
The cardiac late Na (+) current is generated by a small fraction of voltage-dependent Na (+) channels that undergo a conformational change to a burst-gating mode, with repeated openings and closures during the action potential (AP) plateau. Its magnitude can be augmented by inactivation-defective mutations, myocardial ischemia, or prolonged exposure to chemical compounds leading to drug-induced (di)-long QT syndrome, and results in an increased susceptibility to cardiac arrhythmias. Using CytoPatch™ 2 automated patch-clamp equipment, we performed whole-cell recordings in HEK293 cells stably expressing human Nav1.5, and measured the late Na (+) component as average current over the last 100 ms of 300 ms depolarizing pulses to -10 mV from a holding potential of -100 mV, with a repetition frequency of 0.33 Hz. Averaged values in different steady-state experimental conditions were further corrected by the subtraction of current average during the application of tetrodotoxin (TTX) 30 μM. We show that ranolazine at 10 and 30 μM in 3 min applications reduced the late Na (+) current to 75.0 ± 2.7% (mean ± SEM, n = 17) and 58.4 ± 3.5% ( n = 18) of initial levels, respectively, while a 5 min application of veratridine 1 μM resulted in a reversible current increase to 269.1 ± 16.1% ( n = 28) of initial values. Using fluctuation analysis, we observed that ranolazine 30 μM decreased mean open probability p from 0.6 to 0.38 without modifying the number of active channels n, while veratridine 1 μM increased n 2.5-fold without changing p. In human iPSC-derived cardiomyocytes, veratridine 1 μM reversibly increased APD90 2.12 ± 0.41-fold (mean ± SEM, n = 6). This effect is attributable to inactivation removal in Nav1.5 channels, since significant inhibitory effects on hERG current were detected at higher concentrations in hERG-expressing HEK293 cells, with a 28.9 ± 6.0% inhibition (mean ± SD, n = 10) with 50 μM veratridine.
Resumo:
INTRODUCTION Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location. METHODS AND MATERIALS Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used. RESULTS Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001). CONCLUSIONS 3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.