956 resultados para Aperture height index


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fish research institutes in Europe have made considerable effort in developing rapid, objective sensory methods for evaluation of fish freshness. The Quality Index Method(QIM) has been recommended for a European initiative regarding standardisation and harmonisation of sensory evaluation of fish. QIM-schemes have been developed for various common European fish species. Research has now provided the industry with a convenient, objective and powerful tool for measuring freshness of fish kept in ice Further research is needed to evaluate the applicability of QIM for fish handled, stored and processed under different conditions. However, for progress and development of QIM it is now very important that the fish sector implements QIM in fish auctions and the quality management system of the fish processing plants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first part of direct numerical simulation (DNS) of double-diffusive convection in a slim rectangular enclosure with horizontal temperature and concentration gradients. We consider the case with the thermal Rayleigh number of 10^5, the Pradtle number of 1, the Lewis number of 2, the buoyancy ratio of composition to temperature being in the range of [0,1], and height-to-width aspect ration of 4. A new 7th order upwind compact scheme was developed for approximation of convective terms, and a three-stage third-order Runge-Kutta method was employed for time advancement. Our DNS suggests that with the buoyancy ratio increasing form 0 to 1, the flow of transition is a complex series changing fromthe steady to periodic, chaotic, periodic, quasi-periodic, and finally back to periodic. There are two types of periodic flow, one is simple periodic flow with single fundamental frequency (FF), and another is complex periodic flow with multiple FFs. This process is illustrated by using time-velocity histories, Fourier frequency spectrum analysis and the phase-space rajectories.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Human Security Index (HIS) enumerating 200 countries was introduced in 2008. A community-level HSI is under development in the USA. Coastal communities face large disparities in components of human security. How can a HSI support improved policies/services (such as environmental or public health forecasts or warnings) for improving lives? Several issues are discussed. (PDF contains 4 pages)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a scheme for realizing negative refractive index in a four-level atomic system. It is shown that such a system can simultaneously exhibit negative permittivity and negative permeability in an optical frequency range. Furthermore, by analysing the dispersion property of the left-handed material, we find that the probe beam can be controlled from superluminal to subluminal or vice versa via choosing appropriate parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used the technique of non-redundant masking at the Palomar 200-inch telescope and radio VLBI imaging software to make optical aperture synthesis maps of two binary stars, β Corona Borealis and σ Herculis. The dynamic range of the map of β CrB, a binary star with a separation of 230 milliarcseconds is 50:1. For σ Her, we find a separation of 70 milliarcseconds and the dynamic range of our image is 30:1. These demonstrate the potential of the non-redundant masking technique for diffraction-limited imaging of astronomical objects with high dynamic range.

We find that the optimal integration time for measuring the closure phase is longer than that for measuring the fringe amplitude. There is not a close relationship between amplitude errors and phase errors, as is found in radio interferometry. Amplitude self calibration is less effective at optical wavelengths than at radio wavelengths. Primary beam sensitivity correction made in radio aperture synthesis is not necessary in optical aperture synthesis.

The effects of atmospheric disturbances on optical aperture synthesis have been studied by Monte Carlo simulations based on the Kolmogorov theory of refractive-index fluctuations. For the non-redundant masking with τ_c-sized apertures, the simulated fringe amplitude gives an upper bound of the observed fringe amplitude. A smooth transition is seen from the non-redundant masking regime to the speckle regime with increasing aperture size. The fractional reduction of the fringe amplitude according to the bandwidth is nearly independent of the aperture size. The limiting magnitude of optical aperture synthesis with τ_c-sized apertures and that with apertures larger than τ_c are derived.

Monte Carlo simulations are also made to study the sensitivity and resolution of the bispectral analysis of speckle interferometry. We present the bispectral modulation transfer function and its signal-to-noise ratio at high light levels. The results confirm the validity of the heuristic interferometric view of image-forming process in the mid-spatial-frequency range. The signal-to- noise ratio of the bispectrum at arbitrary light levels is derived in the mid-spatial-frequency range.

The non-redundant masking technique is suitable for imaging bright objects with high resolution and high dynamic range, while the faintest limit will be better pursued by speckle imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we briefly summarize two typical morphology characteristics of the self-organized void array induced in bulk of fused silica glass by a tightly focused femtosecond laser beam, such as the key role of high numerical aperture in the void array formation and the concentric-circle-like structure indicated by the top view of the void array. By adopting a physical model which combines the nonlinear propagation of femtosecond laser pulses with the spherical aberration effect (SA) at the interface of two mediums of different refractive indices, reasonable agreements between the simulation results and the experimental results are obtained. By comparing the fluence distributions of the case with both SA and nonlinear effects included and the case with only consideration of SA, we suggest that spherical aberration, which results from the refractive index mismatch between air and fused silica glass, is the main reason for the formation of the self-organized void array. (c) 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electric and magnetic responses of the medium to the probe field are analysed in a four-level loop atomic system by taking into account the relative phase of the applied fields. An interesting phenomenon is found: under suitable conditions, a change of the refractive index from positive to negative can occur by modulating the relative phase of the applied fields. Then the medium can be switched from a positive index material to a negative index material in our scheme. In addition, a negative index material can be realized in different frequency regions by adjusting the relative phase. It may give us a convenient way to obtain the desired material with positive or negative index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New parasitic lasing suppression techniques are developed and high gain amplification is demonstrated in a petawatt level Ti:sapphire amplifier based on the chirped pulse amplification (CPA) scheme. Cladding the large aperture Ti: sapphire with refractive-index matched liquid doped with absorber suppresses the transverse lasing. The acousto-optic programmable dispersive filter (AOPDF) is used to realize side-lobe suppression in the temporal profile of the compressed pulse. The 800 nm laser output with peak power of 0.89 PW and pulse width of 29.0 fs is demonstrated. (c) 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a scheme for realizing negative refractive index in a V-type four-level atomic system. It is shown that the negative refractive index can be achieved in a wide frequency band based on the effect of quantum coherence. It is also found that the frequency band of negative refractive index and the absorption property of left-handed material are manipulated by the pump and control fields. Furthermore, left-handed material with reduced absorption is possible by choosing appropriate parameters. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用几何光学方法对共焦系统扫描时产生的扫描深度与厚度失真进行了理论分析,对名义扫描深度与实际扫描深度之间的关系进行了研究.以若丹明6G薄膜与玻片组成的多层样品为模型,对其进行了模拟计算,得到了扫描深度与厚度失真与系统数值孔径、折射率和样品厚度之间的关系.在实验上分别采用单光子荧光和双光子荧光作为检测信号,在反射式共焦扫描系统上进行了纵向扫描实验,并与模拟计算的结果进行了比较和分析.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O crescimento do percentual de idosos na população ocorre mundialmente tornando necessário conhecer o impacto do processo de envelhecimento, neste contexto, do sistema respiratório. O desconhecimento do impacto do envelhecimento associado a diferentes graus de exposição a poluentes e a presença de comorbidade(s) dificulta a diagnose das pneumopatias acarretando aos idosos piora da qualidade de vida. São vantagens da Técnica de Oscilações Forçadas (FOT): alto potencial de aplicação em idosos, fácil realização, análise detalhada da mecânica respiratória, desempenho de papel complementar, bem como de alternativa na impossibilidade de realização dos exames tradicionais. Foi realizado um estudo experimental comparativo que objetivou investigar o impacto do envelhecimento no sistema respiratório pela FOT e pela espirometria entre grupos de diferentes faixas etárias, sendo a idade a variável independente e as variáveis dependentes, os parâmetros oscilométricos resistência em regime contínuo (R0) e das vias aéreas centrais (Rm), inclinação da resistência (S), frequência de ressonância (fr), reatância média (Xm), complacência dinâmica (Cdin,sr) e os parâmetros espirométricos (VEF1, CVF, VEF1/CVF e FEF/CVF). Foram realizados entrevista, exame clínico, radiografia torácica, avaliação da mecânica respiratória pela FOT e da função pulmonar pela espirometria. 255 indivíduos com idades entre 20 e 86 anos foram entrevistados. Destes, 175 foram excluídos, restando os 80 voluntários analisados, que foram divididos em 6 grupos de acordo com a faixa etária (A: 20 a 29 anos; B: 30 a 39 anos; C: 40 a 49 anos; D: 50 a 59 anos; E: 60 a 69 anos; F: 70 anos ou mais). Foram utilizados os testes de Shapiro-Wilkins, na avaliação da normalidade dos dados biométricos em cada grupo, Oneway ANOVA, na comparação entre os grupos, e Tukey HSD na comparação entre as classes subjacentes. A análise da associação entre duas variáveis foi realizada inicialmente pela regressão univariada entre os parâmetros oscilométricos, a idade e a altura. A regressão múltipla entre os parâmetros oscilométricos, idade e altura foi realizada em conjunto. Foi realizada a análise de confundimento ou modificação de efeito sobre o parâmetro altura na relação entre a idade e os parâmetros oscilométricos. A correção pelo fator altura foi realizada quando sua análise apresentava fator de confundimento. Quanto aos parâmetros resistivos, não foram observadas alterações em R0 e Rm com o envelhecimento enquanto que o declínio observado em S é discreto e não-significativo. Em relação aos parâmetros reativos, verificouse que Cdin,sr e Xm diminuem enquanto que fr aumenta com o processo de envelhecimento. Todas estas alterações são significativas. Todavia, a diminuição da Cdin,sr não apresenta relação com a idade e sim com a altura, que constituiu modificação do efeito. Nos demais parâmetros oscilométricos, a altura constituiu fator de confundimento. Quanto à espirometria, observou-se declínio significativo do VEF1, do VEF1/CVF e da CVF. O índice FEF/CVF apresentou declínio nãosignificativo. Concluindo, a resistência do sistema respiratório e a complacência dinâmica não se modificam enquanto a homogeneidade do sistema respiratório diminui com o processo de envelhecimento.