537 resultados para Ankle sprain
Resumo:
The treatment of the Cerebral Palsy (CP) is considered as the “core problem” for the whole field of the pediatric rehabilitation. The reason why this pathology has such a primary role, can be ascribed to two main aspects. First of all CP is the form of disability most frequent in childhood (one new case per 500 birth alive, (1)), secondarily the functional recovery of the “spastic” child is, historically, the clinical field in which the majority of the therapeutic methods and techniques (physiotherapy, orthotic, pharmacologic, orthopedic-surgical, neurosurgical) were first applied and tested. The currently accepted definition of CP – Group of disorders of the development of movement and posture causing activity limitation (2) – is the result of a recent update by the World Health Organization to the language of the International Classification of Functioning Disability and Health, from the original proposal of Ingram – A persistent but not unchangeable disorder of posture and movement – dated 1955 (3). This definition considers CP as a permanent ailment, i.e. a “fixed” condition, that however can be modified both functionally and structurally by means of child spontaneous evolution and treatments carried out during childhood. The lesion that causes the palsy, happens in a structurally immature brain in the pre-, peri- or post-birth period (but only during the firsts months of life). The most frequent causes of CP are: prematurity, insufficient cerebral perfusion, arterial haemorrhage, venous infarction, hypoxia caused by various origin (for example from the ingestion of amniotic liquid), malnutrition, infection and maternal or fetal poisoning. In addition to these causes, traumas and malformations have to be included. The lesion, whether focused or spread over the nervous system, impairs the whole functioning of the Central Nervous System (CNS). As a consequence, they affect the construction of the adaptive functions (4), first of all posture control, locomotion and manipulation. The palsy itself does not vary over time, however it assumes an unavoidable “evolutionary” feature when during growth the child is requested to meet new and different needs through the construction of new and different functions. It is essential to consider that clinically CP is not only a direct expression of structural impairment, that is of etiology, pathogenesis and lesion timing, but it is mainly the manifestation of the path followed by the CNS to “re”-construct the adaptive functions “despite” the presence of the damage. “Palsy” is “the form of the function that is implemented by an individual whose CNS has been damaged in order to satisfy the demands coming from the environment” (4). Therefore it is only possible to establish general relations between lesion site, nature and size, and palsy and recovery processes. It is quite common to observe that children with very similar neuroimaging can have very different clinical manifestations of CP and, on the other hand, children with very similar motor behaviors can have completely different lesion histories. A very clear example of this is represented by hemiplegic forms, which show bilateral hemispheric lesions in a high percentage of cases. The first section of this thesis is aimed at guiding the interpretation of CP. First of all the issue of the detection of the palsy is treated from historical viewpoint. Consequently, an extended analysis of the current definition of CP, as internationally accepted, is provided. The definition is then outlined in terms of a space dimension and then of a time dimension, hence it is highlighted where this definition is unacceptably lacking. The last part of the first section further stresses the importance of shifting from the traditional concept of CP as a palsy of development (defect analysis) towards the notion of development of palsy, i.e., as the product of the relationship that the individual however tries to dynamically build with the surrounding environment (resource semeiotics) starting and growing from a different availability of resources, needs, dreams, rights and duties (4). In the scientific and clinic community no common classification system of CP has so far been universally accepted. Besides, no standard operative method or technique have been acknowledged to effectively assess the different disabilities and impairments exhibited by children with CP. CP is still “an artificial concept, comprising several causes and clinical syndromes that have been grouped together for a convenience of management” (5). The lack of standard and common protocols able to effectively diagnose the palsy, and as a consequence to establish specific treatments and prognosis, is mainly because of the difficulty to elevate this field to a level based on scientific evidence. A solution aimed at overcoming the current incomplete treatment of CP children is represented by the clinical systematic adoption of objective tools able to measure motor defects and movement impairments. A widespread application of reliable instruments and techniques able to objectively evaluate both the form of the palsy (diagnosis) and the efficacy of the treatments provided (prognosis), constitutes a valuable method able to validate care protocols, establish the efficacy of classification systems and assess the validity of definitions. Since the ‘80s, instruments specifically oriented to the analysis of the human movement have been advantageously designed and applied in the context of CP with the aim of measuring motor deficits and, especially, gait deviations. The gait analysis (GA) technique has been increasingly used over the years to assess, analyze, classify, and support the process of clinical decisions making, allowing for a complete investigation of gait with an increased temporal and spatial resolution. GA has provided a basis for improving the outcome of surgical and nonsurgical treatments and for introducing a new modus operandi in the identification of defects and functional adaptations to the musculoskeletal disorders. Historically, the first laboratories set up for gait analysis developed their own protocol (set of procedures for data collection and for data reduction) independently, according to performances of the technologies available at that time. In particular, the stereophotogrammetric systems mainly based on optoelectronic technology, soon became a gold-standard for motion analysis. They have been successfully applied especially for scientific purposes. Nowadays the optoelectronic systems have significantly improved their performances in term of spatial and temporal resolution, however many laboratories continue to use the protocols designed on the technology available in the ‘70s and now out-of-date. Furthermore, these protocols are not coherent both for the biomechanical models and for the adopted collection procedures. In spite of these differences, GA data are shared, exchanged and interpreted irrespectively to the adopted protocol without a full awareness to what extent these protocols are compatible and comparable with each other. Following the extraordinary advances in computer science and electronics, new systems for GA no longer based on optoelectronic technology, are now becoming available. They are the Inertial and Magnetic Measurement Systems (IMMSs), based on miniature MEMS (Microelectromechanical systems) inertial sensor technology. These systems are cost effective, wearable and fully portable motion analysis systems, these features gives IMMSs the potential to be used both outside specialized laboratories and to consecutive collect series of tens of gait cycles. The recognition and selection of the most representative gait cycle is then easier and more reliable especially in CP children, considering their relevant gait cycle variability. The second section of this thesis is focused on GA. In particular, it is firstly aimed at examining the differences among five most representative GA protocols in order to assess the state of the art with respect to the inter-protocol variability. The design of a new protocol is then proposed and presented with the aim of achieving gait analysis on CP children by means of IMMS. The protocol, named ‘Outwalk’, contains original and innovative solutions oriented at obtaining joint kinematic with calibration procedures extremely comfortable for the patients. The results of a first in-vivo validation of Outwalk on healthy subjects are then provided. In particular, this study was carried out by comparing Outwalk used in combination with an IMMS with respect to a reference protocol and an optoelectronic system. In order to set a more accurate and precise comparison of the systems and the protocols, ad hoc methods were designed and an original formulation of the statistical parameter coefficient of multiple correlation was developed and effectively applied. On the basis of the experimental design proposed for the validation on healthy subjects, a first assessment of Outwalk, together with an IMMS, was also carried out on CP children. The third section of this thesis is dedicated to the treatment of walking in CP children. Commonly prescribed treatments in addressing gait abnormalities in CP children include physical therapy, surgery (orthopedic and rhizotomy), and orthoses. The orthotic approach is conservative, being reversible, and widespread in many therapeutic regimes. Orthoses are used to improve the gait of children with CP, by preventing deformities, controlling joint position, and offering an effective lever for the ankle joint. Orthoses are prescribed for the additional aims of increasing walking speed, improving stability, preventing stumbling, and decreasing muscular fatigue. The ankle-foot orthosis (AFO), with a rigid ankle, are primarily designed to prevent equinus and other foot deformities with a positive effect also on more proximal joints. However, AFOs prevent the natural excursion of the tibio-tarsic joint during the second rocker, hence hampering the natural leaning progression of the whole body under the effect of the inertia (6). A new modular (submalleolar) astragalus-calcanear orthosis, named OMAC, has recently been proposed with the intention of substituting the prescription of AFOs in those CP children exhibiting a flat and valgus-pronated foot. The aim of this section is thus to present the mechanical and technical features of the OMAC by means of an accurate description of the device. In particular, the integral document of the deposited Italian patent, is provided. A preliminary validation of OMAC with respect to AFO is also reported as resulted from an experimental campaign on diplegic CP children, during a three month period, aimed at quantitatively assessing the benefit provided by the two orthoses on walking and at qualitatively evaluating the changes in the quality of life and motor abilities. As already stated, CP is universally considered as a persistent but not unchangeable disorder of posture and movement. Conversely to this definition, some clinicians (4) have recently pointed out that movement disorders may be primarily caused by the presence of perceptive disorders, where perception is not merely the acquisition of sensory information, but an active process aimed at guiding the execution of movements through the integration of sensory information properly representing the state of one’s body and of the environment. Children with perceptive impairments show an overall fear of moving and the onset of strongly unnatural walking schemes directly caused by the presence of perceptive system disorders. The fourth section of the thesis thus deals with accurately defining the perceptive impairment exhibited by diplegic CP children. A detailed description of the clinical signs revealing the presence of the perceptive impairment, and a classification scheme of the clinical aspects of perceptual disorders is provided. In the end, a functional reaching test is proposed as an instrumental test able to disclosure the perceptive impairment. References 1. Prevalence and characteristics of children with cerebral palsy in Europe. Dev Med Child Neurol. 2002 Set;44(9):633-640. 2. Bax M, Goldstein M, Rosenbaum P, Leviton A, Paneth N, Dan B, et al. Proposed definition and classification of cerebral palsy, April 2005. Dev Med Child Neurol. 2005 Ago;47(8):571-576. 3. Ingram TT. A study of cerebral palsy in the childhood population of Edinburgh. Arch. Dis. Child. 1955 Apr;30(150):85-98. 4. Ferrari A, Cioni G. The spastic forms of cerebral palsy : a guide to the assessment of adaptive functions. Milan: Springer; 2009. 5. Olney SJ, Wright MJ. Cerebral Palsy. Campbell S et al. Physical Therapy for Children. 2nd Ed. Philadelphia: Saunders. 2000;:533-570. 6. Desloovere K, Molenaers G, Van Gestel L, Huenaerts C, Van Campenhout A, Callewaert B, et al. How can push-off be preserved during use of an ankle foot orthosis in children with hemiplegia? A prospective controlled study. Gait Posture. 2006 Ott;24(2):142-151.
Resumo:
A main objective of the human movement analysis is the quantitative description of joint kinematics and kinetics. This information may have great possibility to address clinical problems both in orthopaedics and motor rehabilitation. Previous studies have shown that the assessment of kinematics and kinetics from stereophotogrammetric data necessitates a setup phase, special equipment and expertise to operate. Besides, this procedure may cause feeling of uneasiness on the subjects and may hinder with their walking. The general aim of this thesis is the implementation and evaluation of new 2D markerless techniques, in order to contribute to the development of an alternative technique to the traditional stereophotogrammetric techniques. At first, the focus of the study has been the estimation of the ankle-foot complex kinematics during stance phase of the gait. Two particular cases were considered: subjects barefoot and subjects wearing ankle socks. The use of socks was investigated in view of the development of the hybrid method proposed in this work. Different algorithms were analyzed, evaluated and implemented in order to have a 2D markerless solution to estimate the kinematics for both cases. The validation of the proposed technique was done with a traditional stereophotogrammetric system. The implementation of the technique leads towards an easy to configure (and more comfortable for the subject) alternative to the traditional stereophotogrammetric system. Then, the abovementioned technique has been improved so that the measurement of knee flexion/extension could be done with a 2D markerless technique. The main changes on the implementation were on occlusion handling and background segmentation. With the additional constraints, the proposed technique was applied to the estimation of knee flexion/extension and compared with a traditional stereophotogrammetric system. Results showed that the knee flexion/extension estimation from traditional stereophotogrammetric system and the proposed markerless system were highly comparable, making the latter a potential alternative for clinical use. A contribution has also been given in the estimation of lower limb kinematics of the children with cerebral palsy (CP). For this purpose, a hybrid technique, which uses high-cut underwear and ankle socks as “segmental markers” in combination with a markerless methodology, was proposed. The proposed hybrid technique is different than the abovementioned markerless technique in terms of the algorithm chosen. Results showed that the proposed hybrid technique can become a simple and low-cost alternative to the traditional stereophotogrammetric systems.
Resumo:
The aim of the present thesis was to investigate the influence of lower-limb joint models on musculoskeletal model predictions during gait. We started our analysis by using a baseline model, i.e., the state-of-the-art lower-limb model (spherical joint at the hip and hinge joints at the knee and ankle) created from MRI of a healthy subject in the Medical Technology Laboratory of the Rizzoli Orthopaedic Institute. We varied the models of knee and ankle joints, including: knee- and ankle joints with mean instantaneous axis of rotation, universal joint at the ankle, scaled-generic-derived planar knee, subject-specific planar knee model, subject-specific planar ankle model, spherical knee, spherical ankle. The joint model combinations corresponding to 10 musculoskeletal models were implemented into a typical inverse dynamics problem, including inverse kinematics, inverse dynamics, static optimization and joint reaction analysis algorithms solved using the OpenSim software to calculate joint angles, joint moments, muscle forces and activations, joint reaction forces during 5 walking trials. The predicted muscle activations were qualitatively compared to experimental EMG, to evaluate the accuracy of model predictions. Planar joint at the knee, universal joint at the ankle and spherical joints at the knee and at the ankle produced appreciable variations in model predictions during gait trials. The planar knee joint model reduced the discrepancy between the predicted activation of the Rectus Femoris and the EMG (with respect to the baseline model), and the reduced peak knee reaction force was considered more accurate. The use of the universal joint, with the introduction of the subtalar joint, worsened the muscle activation agreement with the EMG, and increased ankle and knee reaction forces were predicted. The spherical joints, in particular at the knee, worsened the muscle activation agreement with the EMG. A substantial increase of joint reaction forces at all joints was predicted despite of the good agreement in joint kinematics with those of the baseline model. The introduction of the universal joint had a negative effect on the model predictions. The cause of this discrepancy is likely to be found in the definition of the subtalar joint and thus, in the particular subject’s anthropometry, used to create the model and define the joint pose. We concluded that the implementation of complex joint models do not have marked effects on the joint reaction forces during gait. Computed results were similar in magnitude and in pattern to those reported in literature. Nonetheless, the introduction of planar joint model at the knee had positive effect upon the predictions, while the use of spherical joint at the knee and/or at the ankle is absolutely unadvisable, because it predicted unrealistic joint reaction forces.
Resumo:
PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.
Resumo:
OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.
Impact of long-term corticosteroid therapy on the distribution pattern of lower limb atherosclerosis
Resumo:
OBJECTIVE: Ectopic calcification and mediacalcinosis can be promoted by corticosteroid use. Aim of the present investigation is to describe macrovascular disease features in patients with long-term corticosteroid therapy and symptomatic lower limb peripheral arterial occlusive disease (PAD). METHODS: A consecutive series of 2783 patients undergoing clinical and angiographic work-up of PAD were screened for long-term (>5 years) corticosteroid use (group A). Comparison was performed to a randomly selected age-, sex- and risk factor-matched PAD control cohort from the same series without corticosteroid use (group B). Patients with diabetes mellitus or severe renal failure were excluded. Arterial calcification was evaluated by qualitative assessment on radiographic images. Severity of atherosclerotic lesions was analysed from angiographic images using a semi-quantitative score (Bollinger score). RESULTS: In general, 12 patients (5 males, mean age 78.5 +/- 9.0 years) with 15 ischaemic limbs qualified to be enrolled in group A and were compared to 23 matching control patients (6 2 males, mean age 79.5 +/- 6 years) with 32 ischaemic limbs. Incompressibility of ankle arteries determined by measurement of the ankle-brachial index was seen in 12 limbs (80%) in group A compared to 3 limbs (9%) in group B (p = 0.0009). No significant difference was found comparing group A and B for segmental calcification, whereas comparison of the atherosclerotic burden using the angiographic severity score showed a significantly higher score at the infragenicular arterial level in group A (p = 0.001). CONCLUSION: Findings suggest that the long-term corticosteroid therapy is associated with a distally accentuated, calcifying peripheral atherosclerosis inducing arterial incompressibility. This occlusion pattern is comparable to patients with renal failure or diabetes. Further research is required to support our observations.
Resumo:
OBJECTIVE: To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. METHODS: A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). RESULTS: Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P < .001 vs .010). Quality of life showed no difference between the treatment groups. In both groups, pain at 90 days had decreased by half, independent of completion of healing. Physical, social, and psychic impairment improved significantly in patients with healed ulcers only. CONCLUSION: Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was not different from that of compression with bandages. Both treatments alleviated pain promptly. Quality of life was improved only in patients whose ulcers had healed.
Resumo:
PURPOSE: To evaluate the use of covered stent-grafts in the endovascular treatment (ET) of popliteal artery aneurysms (PAAs). MATERIALS AND METHODS: A retrospective analysis was conducted over a period of 52 months in 18 consecutive patients (17 men; mean age +/- SD, 70 years +/- 11) undergoing ET of PAAs with the Viabahn endograft in a single center. Patient symptoms, aneurysm characteristics, technical outcomes, complications, and follow-up were assessed. RESULTS: Aneurysm diameters ranged from 12 to 51 mm with a mean of 30 mm (+/-11). Thirteen aneurysms (72.2%) were partially thrombosed and 12 patients (66.6%) had symptoms of lower limb ischemia at presentation (11 chronic and one acute). The technical success rate was 94%. Intraprocedural emboli and endoleak occurred in one and two patients, respectively. Fourteen patients were available for follow-up after successful treatment, with a mean follow-up time of 15 months (range, 7-37 months). All stent-grafts were patent after 1 month, with no mortality or limb loss. The primary patency rate with complete exclusion of the aneurysm at 6 months was 86%. Pre- and postprocedural noninvasive arterial studies were available in 10 patients, demonstrating improvement of the ankle-brachial index from 0.96 +/- 0.41 to 1.17 +/- 0.18, respectively (P = .06). CONCLUSIONS: Endovascular stent-graft repair of PAAs is a feasible treatment option. However, further follow-up studies regarding the durability of results are required.
Resumo:
OBJECTIVE: Dual antiplatelet therapy with clopidogrel plus acetylsalicylic acid (ASA) is superior to ASA alone in patients with acute coronary syndromes and in those undergoing percutaneous coronary intervention. We sought to determine whether clopidogrel plus ASA conferred benefit on limb outcomes over ASA alone in patients undergoing below-knee bypass grafting. METHODS: Patients undergoing unilateral, below-knee bypass graft for atherosclerotic peripheral arterial disease (PAD) were enrolled 2 to 4 days after surgery and were randomly assigned to clopidogrel 75 mg/day plus ASA 75 to 100 mg/day or placebo plus ASA 75 to 100 mg/day for 6 to 24 months. The primary efficacy endpoint was a composite of index-graft occlusion or revascularization, above-ankle amputation of the affected limb, or death. The primary safety endpoint was severe bleeding (Global Utilization of Streptokinase and Tissue plasminogen activator for Occluded coronary arteries [GUSTO] classification). RESULTS: In the overall population, the primary endpoint occurred in 149 of 425 patients in the clopidogrel group vs 151 of 426 patients in the placebo (plus ASA) group (hazard ratio [HR], 0.98; 95% confidence interval [CI], 0.78-1.23). In a prespecified subgroup analysis, the primary endpoint was significantly reduced by clopidogrel in prosthetic graft patients (HR, 0.65; 95% CI, 0.45-0.95; P = .025) but not in venous graft patients (HR, 1.25; 95% CI, 0.94-1.67, not significant [NS]). A significant statistical interaction between treatment effect and graft type was observed (P(interaction) = .008). Although total bleeds were more frequent with clopidogrel, there was no significant difference between the rates of severe bleeding in the clopidogrel and placebo (plus ASA) groups (2.1% vs 1.2%). CONCLUSION: The combination of clopidogrel plus ASA did not improve limb or systemic outcomes in the overall population of PAD patients requiring below-knee bypass grafting. Subgroup analysis suggests that clopidogrel plus ASA confers benefit in patients receiving prosthetic grafts without significantly increasing major bleeding risk.
Resumo:
BACKGROUND: Peripheral artery disease (PAD) is common and imposes a high risk of major systemic and limb ischemic events. The REduction of Atherothrombosis for Continued Health (REACH) Registry is an international prospective registry of patients at risk of atherothrombosis caused by established arterial disease or the presence of 3 atherothrombotic risk factors. METHODS AND RESULTS: We compared the 2-year rates of vascular-related hospitalizations and associated costs in US patients with established PAD across patient subgroups. Symptomatic PAD at enrollment was identified on the basis of current intermittent claudication with an ankle-brachial index (ABI) <0.90 or a history of lower-limb revascularization or amputation. Asymptomatic PAD was diagnosed on the basis of an enrollment ABI <0.90 in the absence of symptoms. Overall, 25 763 of the total 68 236-patient REACH cohort were enrolled from US sites; 2396 (9.3%) had symptomatic and 213 (0.8%) had asymptomatic PAD at baseline. One- and cumulative 2-year follow-up data were available for 2137 (82%) and 1677 (64%) of US REACH patients with either symptomatic or asymptomatic PAD, respectively. At 2 years, mean cumulative hospitalization costs, per patient, were $7445, $7000, $10 430, and $11 693 for patients with asymptomatic PAD, a history of claudication, lower-limb amputation, and revascularization, respectively (P=0.007). A history of peripheral intervention (lower-limb revascularization or amputation) was associated with higher rates of subsequent procedures at both 1 and 2 years. CONCLUSIONS: The economic burden of PAD is high. Recurring hospitalizations and repeat revascularization procedures suggest that neither patients, physicians, nor healthcare systems should assume that a first admission for a lower-extremity PAD procedure serves as a permanent resolution of this costly and debilitating condition.
Resumo:
Complaints of sensory loss and (painful) tingling in a stocking distribution are not uncommon in primary care. These symptoms are especially troublesome while getting asleep. Characteristically, ankle tendon reflexes and vibration perception are diminished. These are the hallmarks of distal-symmetric sensory polyneuropathy (PNP), with diabetes mellitus being the most common cause in our patient population. PNP presents itself only after years of suboptimal glycemic control in diabetes type 1. In patients with type 2, symptoms of PNP can precede formal diagnosis of diabetes! In this mini-review we present an algorithm for diagnosis and management of PNP's in general practice.
Resumo:
The concept of chronic critical limb ischaemia (CLI) emerged late in the history of peripheral arterial occlusive disease (PAOD). The historical background and changing definitions of CLI over the last decades are important to know in order to understand why epidemiologic data are so difficult to compare between articles and over time. The prevalence of CLI is probably very high and largely underestimated, and significant differences exist between population studies and clinical series. The extremely high costs associated with management of these patients make CLI a real public health issue for the future. In the era of emerging vascular surgery in the 1950s, the initial classification of PAOD by Fontaine, with stages III and IV corresponding to CLI, was based only on clinical symptoms. Later, with increasing access to non-invasive haemodynamic measurements (ankle pressure, toe pressure), the need to prove a causal relationship between PAOD and clinical findings suggestive of CLI became a real concern, and the Rutherford classification published in 1986 included objective haemodynamic criteria. The first consensus document on CLI was published in 1991 and included clinical criteria associated with ankle and toe pressure and transcutaneous oxygen pressure (TcPO(2)) cut-off levels <50 mmHg, <30 mmHg and <10 mmHg respectively). This rigorous definition reflects an arterial insufficiency that is so severe as to cause microcirculatory changes and compromise tissue integrity, with a high rate of major amputation and mortality. The TASC I consensus document published in 2000 used less severe pressure cut-offs (≤ 50-70 mmHg, ≤ 30-50 mmHg and ≤ 30-50 mmHg respectively). The thresholds for toe pressure and especially TcPO(2) (which will be also included in TASC II consensus document) are however just below the lower limit of normality. It is therefore easy to infer that patients qualifying as CLI based on TASC criteria can suffer from far less severe disease than those qualifying as CLI in the initial 1991 consensus document. Furthermore, inclusion criteria of many recent interventional studies have even shifted further from the efforts of definition standardisation with objective criteria, by including patients as CLI based merely on Fontaine classification (stage III and IV) without haemodynamic criteria. The differences in the natural history of patients with CLI, including prognosis of the limb and the patient, are thus difficult to compare between studies in this context. Overall, CLI as defined by clinical and haemodynamic criteria remains a severe condition with poor prognosis, high medical costs and a major impact in terms of public health and patients' loss of functional capacity. The major progresses in best medical therapy of arterial disease and revascularisation procedures will certainly improve the outcome of CLI patients. In the future, an effort to apply a standardised definition with clinical and objective haemodynamic criteria will be needed to better demonstrate and compare the advances in management of these patients.
Resumo:
Non-invasive vascular studies can provide crucial information on the presence, location, and severity of critical limb ischaemia (CLI), as well as the initial assessment or treatment planning. Ankle-brachial index with Doppler ultrasound, despite limitations in diabetic and end-stage renal failure patients, is the first-line evaluation of CLI. In this group of patients, toe-brachial index measurement may better establish the diagnosis. Other non-invasive measurements, such as segmental limb pressure, continuous-wave Doppler analysis and pulse volume recording, are of limited accuracy. Transcutaneous oxygen pressure (TcPO(2)) measurement may be of value when rest pain and ulcerations of the foot are present. Duplex ultrasound is the most important non-invasive tool in CLI patients combining haemodynamic evaluation with imaging modality. Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) are the next imaging studies in the algorithm for CLI. Both CTA and MRA have been proven effective in aiding the decision-making of clinicians and accurate planning of intervention. The data acquired with CTA and MRA can be manipulated in a multiplanar and 3D fashion and can offer exquisite detail. CTA results are generally equivalent to MRA, and both compare favourably with contrast angiography. The individual use of different imaging modalities depends on local availability, experience, and costs. Contrast angiography represents the gold standard, provides detailed information about arterial anatomy, and is recommended when revascularisation is needed.
Resumo:
A standard rheumatoid forefoot reconstruction consists of arthrodesis of the first metatarsophalangeal (MTP) joint and resection arthroplasty of the lesser metatarsal heads. However, preservation of the metatarsal heads has gained renewed interest since the medical treatment of rheumatoid arthritis has improved dramatically.