972 resultados para Air Pollution, Indoor
Resumo:
Foliar analysis of biochemical parameters were carried out in order to investigate the influence of air pollutants on two tropical tree species (Licania tomentosa (Benth.) and Bauhinia forfícata (Link.)). Special attention was given to tropospheric ozone due to the fact that concentration levels in the region were found to be up to 140 µg m-3 for a 4 h average time, which is well above the value that can cause injuries to orchides and tobacco (59 µg m-3). Other pollutants such as nitrogen and sulphur oxides were measured and their ambient concentrations were also associated to biochemical alterations in the investigated species.
Resumo:
Perchloroethylene (also known as tetrachloroethylene) is a solvent that has been a mainstay of the dry cleaning industry for decades. Since 1995 the International Agency for Research on Cancer considers that dry cleaning entails exposures that are possibly carcinogenic to humans (Group 2B). Meanwhile, the same institution classified perchloroethylene as probably carcinogenic to humans (Group 2A). Some industries have begun using alternative cleaning methods that do not require the use of perchloroethylene. However, in Portugal this solvent is still the most common dry-cleaning agent. An exploratory study was developed that aimed to find the occupational exposure to perchloroethylene in four Portuguese dry-cleaning stores. Activities involving higher exposure and variables that promote exposure were also investigated. Real-time measurements of volatile organic compounds concentrations were performed using portable equipment (MultiRAE, RAE Systems model – calibrated by isobutylene).
Resumo:
A descriptive study was developed to compare air and surfaces fungal contamination in ten hospitals’ food units and two food units from companies. Fifty air samples of 250 litres through impaction method were collected from hospitals’ food units and 41 swab samples from surfaces were also collected, using a 10 by 10 cm square stencil. Regarding the two companies, ten air samples and eight surface samples were collected. Air and surface samples were collected in food storage facilities, kitchen, food plating and canteen. Outdoor air was also collected since this is the place regarded as a reference. Simultaneously, temperature, relative humidity and meal numbers were registered. Concerning air from hospitals’ food units, 32 fungal species were identified, being the two most commonly isolated genera Penicillium sp.
Resumo:
A preocupação sobre a qualidade do ar nas zonas industriais confere aos estudos sobre a qualidade do ar uma importância acrescida. Este trabalho teve como objectivo saber qual a contribuição dos principais poluentes provenientes do tráfego automóvel para a qualidade do ar na zona do parque industrial da Sapec, da Península da Mitrena, concelho de Setúbal, recorrendo ao modelo meteorológico e de qualidade do ar, TAPM (The Air Pollution Model). Neste trabalho analisaram-se dados da estação de monitorização da qualidade do ar, mais próxima da zona de estudo (Subestação) por forma a caracterizar-se a zona em causa, a nível meteorológico e da qualidade do ar. Os dados metereológico desta estação também foram utilizados com o objectivo de se validar os resultados meteorológicos obtidos pelo modelo. Na avaliação da contribuição do tráfego para a qualidade do ar, recorreu-se a um estudo de tráfego realizado pela Estradas de Portugal (EP) em 2004. Este estudo realizou a contagem dos veículos que se dirigiram ao parque industrial nos dias 14 e 15 de Dezembro, num período de 24 horas. A partir dessa contagem e de factores de emissão foi possível determinar a contribuição, de cada classe de veículo, para as concentrações atmosféricas de PM10 (resultantes de processos de combustão e ressuspensão), NOx, CO e HC. A comparação entre os dados meteorológicos simulados e medidos mostram que o modelo teve um bom comportamento, isto é, as discrepâncias entre os valores simulados e medidos foram mínimas. Relativamente à contribuição de cada categoria de veículos para a qualidade do ar, verificou-se que a classe de pesados de mercadorias foi aquela que mais contribui para as emissões de PM10, NOx e HC, enquanto que para as emissões de CO foram os veículos ligeiros de passageiros que tiveram uma maior contribuição. As classes dos motociclos e ciclomotores foram aquelas que tiveram uma menor contribuição para as concentrações atmosféricas de poluentes. Comparando as emissões de PM10 provenientes dos processos de combustão e de ressuspensão conclui-se que a maior percentagem provem da ressuspensão.
Resumo:
Cooking was found to be a main source of submicrometer and ultrafine aerosols from gas combustion in stoves. Therefore, this study consisted of the determination of the alveolar deposited surface area due to aerosols resulting from common domestic cooking activities (boiling fish, vegetables, or pasta, and frying hamburgers and eggs). The concentration of ultrafine particles during the cooking events significantly increased from a baseline of 42.7 μm2/cm3 (increased to 72.9 μm2/cm3 due to gas burning) to a maximum of 890.3 μm2/cm3 measured during fish boiling in water, and a maximum of 4500 μm2/cm3 during meat frying. This clearly shows that a domestic activity such as cooking can lead to exposures as high as those of occupational exposure activities.
Resumo:
Aflatoxin B1 (AFB1) has been recognized to produce cancer in human liver. In addition, epidemiological and laboratory studies demonstrated that the respiratory system was a target for AFB1. Exposure occurs predominantly through the food chain, but inhalation represents an additional route of exposure. The present study aimed to examine AFB1 exposure among poultry workers in Portugal. Blood samples were collected from a total of 31 poultry workers from six poultry farms. In addition, a control group (n = 30) was included comprised of workers who undertook administrative tasks. Measurement of AFB1 in serum was performed by enzyme-linked immunosorbent assay (ELISA). For examining fungi contamination, air samples were collected through an impaction method. Air sampling was obtained in pavilion interior and outside the premises, since this was the place regarded as the reference location. Using molecular methods, toxicogenic strains (aflatoxin-producing) were investigated within the group of species belonging to Aspergillus flavus complex. Eighteen poultry workers (59%) had detectable levels of AFB1 with values ranging from <1 ng/ml to4.23 ng/ml and with a mean value of 2 ± 0.98ng/ml. AFB1 was not detected in the serum sampled from any of the controls. Aspergillus flavus was the fungal species third most frequently found in the indoor air samples analyzed (7.2%) and was the most frequently isolated species in air samples containing only Aspergillus genus (74.5%). The presence of aflatoxigenic strains was only confirmed in outdoor air samples from one of the units, indicating the presence of a source inside the building in at least one case. Data indicate that AFB1 inhalation represents an additional risk in this occupational setting that needs to be recognized, assessed, and prevented.
Resumo:
Dust is a complex mixture of particles of organic and inorganic origin and different gases absorbed in aerosol droplets. In a poultry unit include dried faecal matter and urine, skin flakes, ammonia, carbon dioxide, pollens, feed and litter particles, feathers, grain mites, fungi spores, bacteria, viruses and their constituents. Dust particles vary in size and differentiation between particle size fractions is important in health studies in order to quantify penetration within the respiratory system. A descriptive study was developed in order to assess exposure to particles in a poultry unit during different operations, namely routine examination and floor turn over. Direct-reading equipment was used (Lighthouse, model 3016 IAQ). Particle measurement was performed in 5 different sizes (PM0.5; PM1.0; PM2.5; PM5.0; PM10). The chemical composition of poultry litter was also determined by neutron activation analysis. Normally, the litter of poultry pavilions is turned over weekly and it was during this operation that the higher exposure of particles was observed. In all the tasks considered PM5.0 and PM10.0 were the sizes with higher concentrations values. PM10 is what turns out to have higher values and PM0.5 the lowest values. The chemical element with the highest concentration was Mg (5.7E6 mg.kg-1), followed by K (1.5E4 mg.kg-1), Ca (4.8E3 mg.kg-1), Na (1.7E3 mg.kg-1), Fe (2.1E2 mg.kg-1) and Zn (4.2E1 mg.kg-1). This high presence of particles in the respirable range (<5–7μm) means that poultry dust particles can penetrate into the gas exchange region of the lung. Larger particles (PM10) present a range of concentrations from 5.3E5 and 3.0E6 mg/m3.
Resumo:
Mestrado em Engenharia Química
Resumo:
Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.
Resumo:
Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.
Resumo:
Considering vehicular transport as one of the most health‐relevant emission sources of urban air, and with aim to further understand its negative impact on human health, the objective of this work was to study its influence on levels of particulate‐bound PAHs and to evaluate associated health risks. The 16 PAHs considered by USEPA as priority pollutants, and dibenzo[a, l]pyrene associated with fine (PM2.5) and coarse (PM2.5–10) particles were determined. The samples were collected at one urban site, as well as at a reference place for comparison. The results showed that the air of the urban site was more seriously polluted than at the reference one, with total concentrations of 17 PAHs being 2240% and 640% higher for PM2.5 and PM2.5–10, respectively; vehicular traffic was the major emission source at the urban site. PAHs were predominantly associated with PM2.5 (83% to 94% of ΣPAHs at urban and reference site, respectively) with 5 rings PAHs being the most abundant groups of compounds at both sites. The risks associated with exposure to particulate PAHs were evaluated using the TEF approach. The estimated value of lifetime lung cancer risks exceeded the health‐based guideline levels, thus demonstrating that exposure to PM2.5‐bound PAHs at levels found at urban site might cause potential health risks. Furthermore, the results showed that evaluation of benzo[a] pyrene (regarded as a marker of the genotoxic and carcinogenic PAHs) alone would probably underestimate the carcinogenic potential of the studied PAH mixtures.
Resumo:
Every year European citizens become victims of devastating fires, which are especially disastrous for Southern European countries. Apart from the numerous health and economic consequences, fires generate hazardous pollutants that are introduced into the environment, thus representing serious risks for public health. In that regard, particulate matter (PM) is of amajor concern. Thus, the objectives of thisworkwere to characterize the trend of forest fire occurrences and burnt area during the period of 2005 and 2010 and to study the influence of forest fires on levels of particulatematter PM10 and PM2.5. In 2010, 22,026 forest fires occurred in Portugal. The northern region was the most affected by forest fires, with 27% of occurrences in Oporto district. The annual means of PM10 and PM2.5 concentrations at two urban background sites were 25±14 μg m−3 and 8.2±4.9 μg m−3, and 17±13 μg m−3 and 7.3±5.9 μg m−3, respectively. At both sites the highest levels of PMfractionswere observed during July and August of 2010, corresponding to the periods when majority (66%) of forest fires occurred. Furthermore, PM10 daily limit at the two sites was exceeded during 20 and 5 days, respectively; 56%, and respectively 60% of those exceedances occurred during the forest fire season. Considering that the risks of forest fire ignition and severity are enhanced with elevated temperatures, the climate change might increase the environmental impacts of forest fires.
Resumo:
Atmospheric pollution by motor vehicles is considered a relevant source of damage to architectural heritage. Thus the aim of this work was to assess the atmospheric depositions and patterns of polycyclic aromatic hydrocarbons (PAHs) in façades of historical monuments. Eighteen PAHs (16 PAHs considered by US EPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) were determined in thin black layers collected from façades of two historical monuments: Hospital Santo António and Lapa Church (Oporto, Portugal). Scanning electron microscopy (SEM) was used for morphological and elemental characterisation of thin black layers; PAHs were quantified by microwave-assisted extraction combined with liquid chromatography (MAE-LC). The thickness of thin black layers were 80–110 μm and they contained significant levels of iron, sulfur, calcium and phosphorus. Total concentrations of 18 PAHs ranged from 7.74 to 147.92 ng/g (mean of 45.52 ng/g) in thin black layers of Hospital Santo António, giving a range three times lower than at Lapa Church (5.44– 429.26 ng/g; mean of 110.25 ng/g); four to six rings compounds accounted at both monuments approximately for 80–85% of ΣPAHs. The diagnostic ratios showed that traffic emissions were significant source of PAHs in thin black layers. Composition profiles of PAHs in thin black layers of both monuments were similar to those of ambient air, thus showing that air pollution has a significant impact on the conditions and stone decay of historical building façades. The obtained results confirm that historical monuments in urban areas act as passive repositories for air pollutants present in the surrounding atmosphere.
Resumo:
OBJECTIVE: To estimate the prevalence of lead poisoning in children and to identify associated factors, as well as possible local sources of contamination. METHODS: A cross-sectional prevalence study conducted in 2006 with a random sample of 97 children age zero to five years from a neighborhood in Porto Alegre, Southern Brazil. Blood lead levels were measured and a questionnaire administered to collect information on sociodemographics, recycling and dwelling. A preliminary environmental evaluation was carried out with direct analysis of soil and indirect analysis of air pollution with bioindicators to identify possible sources of contamination. To analyze lead concentrations from the different collection sites, for each type of material studied, ANOVA was performed with a Brown-Forsythe adjustment for heteroscedasticity and with Dunnett's T3 procedure for multiple comparisons of unequal variances. RESULTS: Blood lead levels > 10.0 µg/dL was found in 16.5% of children. Recycling of waste at home, low father's education level, and increased age of children were associated with increase blood lead levels. High lead levels were found in soil, and there was little indication of lead air pollution. CONCLUSIONS: A high prevalence of lead poisoning was identified, and the potential sources of contamination in this community appear related to waste recylcing activities. Studies should be conducted with other populations of Brazilian children and evaluate potential sources of local and general contamination, to accurately characterize this issue in Brazil.
Resumo:
OBJECTIVE: To analyze the impact of intra-urban atmospheric conditions on circulatory and respiratory diseases in elder adults. METHODS: Cross-sectional study based on data from 33,212 hospital admissions in adults over 60 years in the city of São Paulo, southeastern Brazil, from 2003 to 2007. The association between atmospheric variables from Congonhas airport and bioclimatic index, Physiological Equivalent Temperature, was analyzed according to the district's socioenvironmental profile. Descriptive statistical analysis and regression models were used. RESULTS: There was an increase in hospital admissions due to circulatory diseases as average and lowest temperatures decreased. The likelihood of being admitted to the hospital increased by 12% with 1ºC decrease in the bioclimatic index and with 1ºC increase in the highest temperatures in the group with lower socioenvironmental conditions. The risk of admission due to respiratory diseases increased with inadequate air quality in districts with higher socioenvironmental conditions. CONCLUSIONS: The associations between morbidity and climate variables and the comfort index varied in different groups and diseases. Lower and higher temperatures increased the risk of hospital admission in the elderly. Districts with lower socioenvironmental conditions showed greater adverse health impacts.