492 resultados para Aerospike nozzle
Resumo:
The application technology shows many parameters related to the quality of the application, one is the droplet spectrum, which is influenced by the spray nozzles and the adjuvant used. Therefore, the objective of this work was estimate the behavior of the droplet spectrum generated with different nozzles and different adjuvants. The experiment was installed containing four solutions from different type adjuvant dilution, as vegetal oil, mineral oil, surfactant and drift reduction, which were applied with two nozzle, one pre-orifice flat fan (DG 8003 VS) and other of air induction flat fan (AI 8003 VS), totaling 8 treatments with 3 repetitions. The experiment was realized in ideal weather conditions for spraying. The treatments averages were compared using Confidence Interval at 95% probability and the correlations between variables were analyzed using Pearson at 5% of probability. The analysis of droplet spectrum showed different behavior for each adjuvant and nozzle. The surfactant treatment showed VMD superior for all treatments when sprayed with AI nozzles. For the %vol.<100 µm the lowest value found was for the AI nozzle in combination with the surfactant. The significant correlations found for the nozzles AI and DG were negative between VMD and %vol.<100 µm. It can be concluded that the values of DMV and %vol.<100 µm showed that the nozzle with pre-orifice have droplet spectrum more prone to drift. The surfactant showed to be the best drift reduction technique when combined with the AI nozzle.
Resumo:
This study aimed to verify the influence of adjuvants on the droplet spectrum of an air induction nozzle. The experiment used nine spray solutions, one including only water and eight containing adjuvants: Nimbus® (mineral oil), Óleo vegetal Nortox (vegetal oil), Li-700® (a mixture of lecithin and propionic acid), Agral® (nonyl phenoxy poly ethanol), In-Tec® (nonyl phenol ethoxylate), Antideriva (nonyl phenol ethoxylate), Silwet® L-77 Ag (copolymer polyester and silicon) and TA 35 (sodium lauryl ether sulfate). A flat fan air induction nozzle Hypro® Guardian Air 110 03 was used for the droplet spectrum evaluation. The study was conducted at the Laboratory for Particle Size Analysis (Lapar), at FCAV/UNESP, Jaboticabal/SP - Brazil. The determination of the droplet spectrum characteristics (Volume Median Diameter/VMD, percentage of droplets smaller than 100 micrometers and span) was carried out by a particle size analyzer by laser diffraction Mastersizer S (Malvern Instruments). For statistical analysis the mean values were compared using Confidence Interval at 95% (CI 95%). The results showed that for the Hypro® GA air induction nozzle the oil based adjuvants (Óleo Vegetal Nortox e Nimbus®) increased the VMD. The percentage of droplets smaller than 100 micrometers was lower for the Agral®, Antideriva, In-Tec® e TA 35, in comparison with the Óleo Vegetal Nortox and Li-700®. The span was higher for the oil based adjuvants (Óleo Vegetal Nortox e Nimbus®) and lower for the TA 35 (sodium lauryl ether sulfate), showing that the TA 35 adjuvant has a potential to improve the quality of the droplet spectrum of the Hypro® GA 11003 nozzle.
Resumo:
The aim of this study was to build and validate a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) to apply a spray solutions containing water plus a food dye (Blue FDC) at 0,6% m v-1 mixed with two adjuvants: a polymer based anti drift formulation at 0,06% m v-1 and a sodium lauryl ether sulfate based surfactant at 0,2% v v-1. After a 10-second application the drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The wind tunnel had low levels of turbulence and high repeatability of the data, which means that the flow was uniform and able to be used for carrying out measures to estimate drift. The validation results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk potential under those spray technologies. The use of an adjuvant based on a polymer reduced the amount of drift from the nozzle compared to the surfactant.
Resumo:
The aim of this work was to evaluate the effect of the addition of different surfactants in physical and chemical properties of spray solutions, droplets spectra and drift potential on agricultural spraying. The surfactants and concentrations (v v-1) were: Haiten (0.1%), Antideriva and Intec (0.05% and 0.1%). The following characteristics were analyzed: surface tension, viscosity, density and electric conductivity. The droplet size spectrum was determined by a laser particle analyzer (Mastersizer S®, version 2.15) including measurements of volume medium diameter (VMD), the percent of droplets below 50 and 100 μm (V50 e V100) and index span. In order to estimate the drift potential, a series of wind tunnel tests were performed with a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) used to apply the spray solutions containing water, the adjuvants and a food color dye (Brilliant blue FD & C no 1) at 0,6% m v-1. The drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The results showed that the addition of adjuvants changed physical and chemical properties of spray solutions in different magnitudes according to the surfactant. Surfactants changed the droplet spectrum and drift potential, indicating that higher VMD and smaller V100 induced higher percentage of drift.
Resumo:
The aim of this study was to evaluate the influence of fine and medium droplets in the performance of flutriafol and thiophanate methyl + flutriafol for the control of Asian Soybean Rust (Phakopsora pachyrhizi Sydow & Sydow). The experiment was a 2 x 2 factorial design (2 droplet sizes x 2 fungicides) resulting in four treatments with six replications. The experimental area was set up with 24 plots (50 x 21 m). In each plot there was a central assessment area with 10 x 20 m. To the each plot there was a non-treated area placed in opposed direction to the wind. The evaluations of rust control were made by of the calculation of incidence (percentage of plants with rust), severity (level of infection), defoliations and soybean yield. The results were analyzed by the calculation of the confidence interval at 90%. The study was set up in curative control conditions with average infestation of 68.6%, average severity in the lower part of the canopy was of 35.9% and on the upper parte it was 4.57%. The results of severity, defoliation and productivity did not show statistical difference among the treatments. However, it was observed that in general there was tendency of better results with the application of flutriafol alone comparing with thiophanate methyl + flutriafol, since there was a small difference between two commercial products in the flutriafol active ingredient content (62.5 g ha-1 to the flutriafol alone and 60 g ha-1 to the thiophanate methyl + flutriafol). There was no statistical difference between fine and medium droplets. This fact can be explained by the characteristics of systemic action of the flutriafol and by the type of control made (curative). The flutriafol, being a systemic fungicide is less sensitive to the better coverage provided by the smaller droplets and, on the curative control, the amount of product deposited can became more import than coverage, mainly on the superior part of the leaves. These leaves are healthier than the inferior leaves that in general are the first to become completely compromised by the rust, losing importance to the plant. By this reason, medium droplets appear to have offered similar performance even not offering advantages in the leaf coverage. This fact may become important because in the practical side of the use of medium droplets, since this may increase the amount of time to spray, mainly because the fine and very fine droplets have more limitations related to drift and evaporation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Herbicides application success depends, besides product correct choice, the observation of environmental conditions and application quality. The work aimed to quantify the effects of surfactant addition in spraying solution, in natural and artificial targets, associated to different nozzle boom angles in relation to application offset, by using distinct evaluation methods. Two experiments were conducted at NuPAM-FCA/UNESP, Botucatu County, São Paulo State, constituted by ten treatments, in factorial scheme 2 × 5, corresponding to two spraying solutions conditions (absence or presence of Aterbane BRTM (0.25% v/v) adjuvant) and five angles of spray nozzle in relation to offset application (-30°, -15°, 90°, +15° and +30°). In Ipomea grandifolia leaves, the distribution and drops deposition of a tracer solution were evaluated by using scores visual and spectrophotometer process. In hydro sensible papers, volumetric medium diameter (VMD), density (cm2 ) and drops medium diameter, covered area (%) and application fees (L ha-1) were evaluated through e-SprinkleTM software. Aterbane BRTM (0.25% v/v) presence or absence, associated or no, to spray nozzles offset did not provide significant differences in I. grandifolia spray deposition. The use of artificial targets presented applicative technical limitations in relation to the use of natural ones as study matrix. Deposit and distribution variables esteem distinct behaviours, independent of target nature.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work, the project of a new experimental facility to be installed at the Aerodynamics Division of the Institute of Aeronautics and Space is presented. This new facility will provide means to perform experimental campaigns to analyze the flow behavior at different rocket nozzle concepts using cold gas that will be obtained from a modification of the Pilot Transonic Wind Tunnel air system. The new installation will enable less expensive experiments in a more secure environment, since the cold gas experimental procedures do not demand fuel storage and burn and security procedures are much less severe. Furthermore, experiments can be carried with different types of sensors, commonly used in wind tunnel tests. Also, the optical access is facilitated enabling the use of optical techniques for the characterization of flow properties inside the nozzles, such as pressure and temperature sensitive painting. The full project design and the operation conditions will be showed, as also some technical considerations about the flor behavior in the facility
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work, the project of a new experimental facility to be installed at the Aerodynamics Division of the Institute of Aeronautics and Space is presented. This new facility will provide means to perform experimental campaigns to analyze the flow behavior at different rocket nozzle concepts using cold gas that will be obtained from a modification of the Pilot Transonic Wind Tunnel air system. The new installation will enable less expensive experiments in a more secure environment, since the cold gas experimental procedures do not demand fuel storage and burn and security procedures are much less severe. Furthermore, experiments can be carried with different types of sensors, commonly used in wind tunnel tests. Also, the optical access is facilitated enabling the use of optical techniques for the characterization of flow properties inside the nozzles, such as pressure and temperature sensitive painting. The full project design and the operation conditions will be showed, as also some technical considerations about the flor behavior in the facility
Resumo:
Period adding cascades have been observed experimentally/numerically in the dynamics of neurons and pancreatic cells, lasers, electric circuits, chemical reactions, oceanic internal waves, and also in air bubbling. We show that the period adding cascades appearing in bubbling from a nozzle submerged in a viscous liquid can be reproduced by a simple model, based on some hydrodynamical principles, dealing with the time evolution of two variables, bubble position and pressure of the air chamber, through a system of differential equations with a rule of detachment based on force balance. The model further reduces to an iterating one-dimensional map giving the pressures at the detachments, where time between bubbles come out as an observable of the dynamics. The model has not only good agreement with experimental data, but is also able to predict the influence of the main parameters involved, like the length of the hose connecting the air supplier with the needle, the needle radius and the needle length. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3695345]
Computational and experimental characterization of a low-cost piezoelectric valveless diaphragm pump
Resumo:
Flow pumps act as important devices in areas such as Bioengineering, Medicine, and Pharmacy, among other areas of Engineering, mainly for delivering liquids or gases at small-scale and precision flow rate quantities. Principles for pumping fluids based on piezoelectric actuators have been widely studied, since they allow the construction of pump systems for displacement of small fluid volumes with low power consumption. This work studies valveless piezoelectric diaphragm pumps for flow generation, which uses a piezoelectric ceramic (PZT) as actuator to move a membrane (diaphragm) up and down as a piston. The direction of the flow is guaranteed by valveless configuration based on a nozzle-diffuser system that privileges the flow in just one pumping direction. Most research efforts on development of valveless flow pump deal either with computational simulations based on simplified models or with simplified physical approaches based on analytical models. The main objective of this work is the study of a methodology to develop a low-cost valveless piezoelectric diaphragm flow pump using computational simulations, parametric study, prototype manufacturing, and experimental characterization. The parametric study has shown that the eccentricity of PZT layer and metal layer plays a key role in the performance of the pump.
Resumo:
Nanocomposite fibers based on multi-walled carbon nanotubes (MWCNT) and poly(lactic acid) (PLA) were prepared by solution blow spinning (SBS). Fiber morphology was characterized by scanning electron microscopy (SEM) and optical microscopy (OM). Electrical, thermal, surface and crystalline properties of the spun fibers were evaluated, respectively, by conductivity measurements (4-point probe), thermogravimetric analyses (TGA), differential scanning calorimetry (DSC), contact angle and X-ray diffraction (XRD). OM analysis of the spun mats showed a poor dispersion of MWCNT in the matrix, however dispersion in solution was increased during spinning where droplets of PLA in solution loaded with MWCNT were pulled by the pressure drop at the nozzle, producing PLA fibers filled with MWCNT. Good electrical conductivity and hydrophobicity can be achieved at low carbon nanotube contents. When only 1 wt% MWCNT was added to low-crystalline PLA, surface conductivity of the composites increased from 5 x 10(-8) to 0.46 S/cm. Addition of MWCNT can slightly influence the degree of crystallinity of PLA fibers as studied by XRD and DSC. Thermogravimetric analyses showed that MWCNT loading can decrease the onset degradation temperature of the composites which was attributed to the catalytic effect of metallic residues in MWCNT. Moreover, it was demonstrated that hydrophilicity slightly increased with an increase in MWCNT content. These results show that solution blow spinning can also be used to produce nanocomposite fibers with many potential applications such as in sensors and biosensors.