999 resultados para índice de fluxo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas chromatography coupled with mass spectrometry (GC-MS) is widely used for the characterization of volatile compounds. However, due to the complexity of the soluble coffee matrix, a complete identification of the components should not be based on mass spectra interpretation only. The linear index of retention (LRI) is frequently used to give support to mass spectra. The aim of this work is to investigate the characterization of the volatile compounds in soluble coffee samples by GC-MS using LRI values found with a HP-INNOWAX column. The method used allows a significant increase of the reliability of identifying compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL) comparable to that of a 1-cm conventional cell (80 µL). Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999). The increase in sensitivity (30.4-fold) in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The psychometric properties of the Personal Wellbeing Index are analyzed on a Spanish and Portuguese adolescent sample. We test the reliability of the scale using Cronbach’s alpha. And complementarily we analyze the item-total correlations in the different wellbeing domains included. We execute an exploratory factor analysis (principal components) and a multigroup Confirmatory Factor Analysis (CFA). The results show that Cronbach’s alpha is 0.79 for the Chilean version and in the Brazilian version is 0.78 confirming adequate levels of reliability found in previous studies. Correlations between fields of well-being shows values ranging between 0.224 and 0.496 for Chile and from 0.24 to 0.46 for Brazil. The results are similar to those obtained in other countries. The monofactorial structure of the scale is cinfirmed, also the adjustment to the scale structure to the data of the two samples and the comparability of means of global indices. The results suggest the existence of other well-being domains that had not been considered in the original proposal of the scale

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first computational implementation that automates the procedures involved in the calculation of infrared intensities using the charge-charge flux-dipole flux model is presented. The atomic charges and dipoles from the Quantum Theory of Atoms in Molecules (QTAIM) model was programmed for Morphy98, Gaussian98 and Gaussian03 programs outputs, but for the ChelpG parameters only the Gaussian programs are supported. Results of illustrative but new calculations for the water, ammonia and methane molecules at the MP2/6-311++G(3d,3p) theoretical level, using the ChelpG and QTAIM/Morphy charges and dipoles are presented. These results showed excellent agreement with analytical results obtained directly at the MP2/6-311++G(3d,3p) level of theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multicommuted method for determination of chlorine in water samples using a 100-cm cell was developed. In this method, orto-Tolidine reacts with chlorine and the product was monitored at 438 nm. The analytical curve for chlorine was linear in concentration range from 1.34x10-6 to 2.01x10-5 mol L-1 with a detection limit of 9.40x10-8 mol L-1. A sampling rate of 45 h-1and a RSD of 1.0 % (n = 15) were obtained. The method was applied with success for chlorine determination in six water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A binary sampling flow analysis system equipped with gas diffusion cell was developed for NH4+ and/or NH2Cl determination in wastewater and disinfection products samples based on the Berthelot reaction of the NH2Cl diffused through the semi-permeable PTFE membrane. The effect of the analytical conditions related to the reaction and flow parameters were evaluated and N-NH4+ and N-NH2Cl were determined in concentration ranges from 0.17 to 5 mg L-1 and from 0.5 to 14.5 mg L-1, respectively. Limits of detection (3σ) of 50 and 140 µg L-1 for N-NH4+ and N-NH2Cl were calculated, respectively, and RSD of 5 and 2% were calculated for 10 consecutive determinations of N-NH4+ (1 and 3 mg L-1) and N-NH2Cl (3 and 9 mg L-1), respectively with 30 determinations h-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection chemiluminescence method for the determination of paracetamol in pharmaceutical formulations is described. It is based on the consumption of the sodium hypochlorite by paracetamol and decreases of the analytical signal. The analytical curve was linear in the paracetamol concentration range from 5.0 x 10-6 to 5.0 x 10-5 mol L-1, with a detection limit of 1.8 x 10-6 mol L-1. The RSDs were 2.0 and 1.2% respectively for 2.0 x 10-5 and 4.0 x 10-5 mol L-1 paracetamol solutions (n = 10) and a sampling frequency of 180 h-1 was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, accurate and precise flow-injection turbidimetric procedure for the determination of fluoxetine hydrochloride in pharmaceutical formulations is reported. The procedure is based on the precipitation of chloride of fluoxetine hydrochloride with silver nitrate solution and the yielded insoluble AgCl(s) was monitored at 420 nm. The analytical curve was linear in the fluoxetine hydrochloride concentration range 3.0 x 10-5 - 5.0 x 10-4 mol L-1 with a detection limit of 10 µmol L-1 and, a sample throughout of 60 h-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes a low-cost electrochemical "wall-jet" detector for flow analysis. The electrolytic solution enters into the cell through a tube of stainless steel (200 to 300 µm i.d), reaching to the center of the working electrode perpendicularly and then being mixed to the remaining solution in the cell, which flows under atmospheric pressure into a waste reservoir. The proposed electrochemical detector can be used with any type of working electrode, from commercial to home-made, such as glassy carbon and metallic electrodes (modified or unmodified), which enlarge the applications of the electrochemical detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, robust, versatile, high analytical frequency method was proposed to check if a sample of wine is within the range of standards set by the manufacturer, using the UV-VIS spectroscopy, multivariate analysis and a flow-batch analyzer. Two hundred and fifty-two samples of wines were analyzed. The results from the application of Hierachical Cluster Analysis (HCA) to the matrix of the data involving all samples show the formation of fifteen types of wine. A Soft Independent Modelling of Class Analogy (SIMCA) model was constructed and used to classify the samples of the overall forecast. As a result, it is observed that the prediction was performed with a success rate of 99.2% for a confidence level of 95%. This shows that the proposed methodology can be used as an effective tool for classifying of samples of wines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a study of electrochemical degradation of the chloramphenicol antibiotic in aqueous medium using a flow-by reactor with DSA® anode. The process efficiency was monitored by chloramphenicol concentration analysis with liquid chromatography (HPLC) during the experiments. Analysis of Total Organic Carbon (TOC) was performed to estimate the degradation degree and Ion Chromatography (IC) was performed to determinate inorganic ions formed during the eletrochemical degradation process. In electrochemical flow-by reactor, 52% of chloramphenicol was degraded, with 12% TOC reduction. IC analysis showed the production of chloride ions (25 mg L-1), nitrate ions (6 mg L-1) and nitrite ions (4.5 mg L-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the growth of corundum crystals by the flux method. The main objective was the evaluation of versatility, effectiveness and real possibilities of the flux method to the synthesis and doping of monocrystals with impurities of particular interest. In this work the chosen impurities were i) Cr and ii) Fe and Ti, aiming the synthesis of rubies and sapphires, respectively. The crystals were grown by heating a mixture of Al2O3:Cr or Al2O3:Fe:Ti and flux (MoO3). The maximum crystal size obtained was 1.0 mm, all transparent, presenting well developed faces, bipiramidal hexagonal shape, and showing a typical red (ruby) and/or light blue (sapphire) color. EDX and XPD experiments were performed in order to characterize some of the synthesized crystals. All crystallized specimens presented the α-alumina atomic structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The decomposition of detergent powder samples in a microwave oven and autoclave was evaluated. To establish the best experimental conditions a 2(5) factorial design was performed, varying the conditions in autoclave and microwave digestion and flow system parameters for the determination of phosphorus. The best composition was: 0.2 mL sulfuric acid; 500 W power and a 2 min time interval; 6 mmol L-1 of ascorbic acid and 16 mmol L-1 of molybdate to flow system. This factor levels use less reagents than the reference method. No statistically significant differences were found between the autoclave and microwave oven responses at the 95% confidence level.