906 resultados para wastewater irrigation
Resumo:
This study investigated the effects of electrolytic treatment using Dimensionally Stable Anode (DSA, 70%TiO2/30%RuO2) type electrodes in simulated wastewater containing aromatic amine n-phenyl-n'-1,3-dimethylbutyl-p-phenylenediamine (Flexzone 7P). A low direct current density of 0.025 A cm(-2) was applied for periods up to 60 minutes and a 52.6% decrease in Flexzone 7P concentration was observed. Ultraviolet-visible spectra, gas chromatography, toxicity and biodegradation tests were carried out with the aim of verifying the toxic by-products that were formed. Ultraviolet-visible spectra of simulated wastewater exhibited changes in the aromatic amine's molecular structure. Additionally, based on the S. cerevisiae toxicity test, it was observed that detoxification of the wastewater occurred after 15 minutes of electrolysis. It was also observed that five minutes of treatment were sufficient to improve the biodegradation rate, determined through the respirometric Bartha method.
Resumo:
The aim of this work was to observe the interaction between soil moisture and irrigation time intervals on the germination of sugarcane cv. RB785148 sets in semi-controlled conditions. One-bud sets of the variety RB785148 were germinated in ceramic pots filled with soil under a transparent PVC cover using soil humidity levels of 22, 25 and 30%, that were restored at intervals of 7, 14 and 21 days. The experiment was carried out at three different periods of the year: May-June/94; Oct.-Nov./94; and Mar.-Apr./95. The results indicate that the germination decreased mainly in function of the decrease in soil humidity, whereas irrigation interval have no statistical effect on germination. An interaction between humidity level and irrigation interval was observed. A variation of the timecourse of the germination could be observed when the results of the experiments installed at different dates were compared.
Resumo:
A viability study of an electrolytic process for the transformation of organic matter and free sulphide contained in wastewater from a fowl slaughterhouse in order to minimise odours was carried out Cast iron and aluminium electrodes were tried at 7.09 mA/cm2, under strong agitation, at 297 K. Conductivity, pH, chemical oxygen demand (COD), amount of settleable solids, and sulphide content were monitored with electrolysis duration. The cast iron electrodes were found to be viable for the elimination of soluble sulphides in the wastewater, leading to the elimination of its strong odour after short times of electrolysis. A significant decrease in COD was also attained.
Resumo:
It is presented two study cases about the approach in root analysis at field and laboratory conditions based on digital image analysis. Grapevine (Vitis vinifera L.) and date palm (Phoenix dactylifera L.) root systems were analyzed by both the monolith and trench wall method aided by digital image analysis. Correlation between root parameters and their fractional distribution over the soil profile were obtained, as well as the root diameter estimation. Results have shown the feasibility of digital image analysis for evaluation of root distribution.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to carry out a scanning electron microscopic (SEM) analysis of the cleaning qualities and smear layer removal from root canal walls, instrumented and irrigated with 2.5% NaOCl, 2.0% chlorhexidine and saline solutions. Fifty extracted teeth were used in this study. All teeth were radiographed to determine the existence of a single canal. The crowns were cut at the cervical limit and the root canals were instrumented with K-type files up to size 45. During root canal preparation, irrigations were made with the different solutions being evaluated: Group 1: 2.5% NaOCl (10 roots); Group 2: 2.5% NaOCl and 17% EDTA for 2 minute (10 roots); Group 3: 2.0% chlorhexidine (10 roots); Group 4: 2.0% chlorhexidine and 17% EDTA for 2 minutes (10 roots); Group 5: saline solution (5 roots); Group 6: saline solution and 17% EDTA for 2 minutes (5 roots). After instrumentation, the canals were irrigated with each one of the solutions and the roots were cut in the buccolingual direction for SEM analysis, at the cervical, middle and apical thirds, to ascertain the presence or absence of smear layer and debris. SEM analysis was performed by three calibrated examiners and scores were submitted to Kruskal-Wallis test at the significance level of p = 5%. Results showed that the use of 17% EDTA decreased the smear layer significantly (p < 0.05) for all evaluated solutions in all thirds. When EDTA was not used, a significantly higher quantity of smear layer on the apical third was observed only in the NaOCl groups. The use of 17% EDTA was significant for debris removal except for the chlorhexidine groups. The following conclusion could be drawn: the use of 17% EDTA was necessary to enhance cleanness of the root canals.
Resumo:
Objective. To assess the potential for contamination of wastewaters from pig farming. Methods. Wastewaters from pig farming were stored in a tank. After 0, 30, 60, 90, and 120 days of hydraulic retention, they were added to lysimeters filled with argillaceous, sandy, or medium soil. Finally, these lysimeters were submitted to simulations of either a rainy season or a dry season. The number of colony-forming units (CFUs) of total coliforms, fecal coliforms, and fecal streptococci was measured in the effluents of the storage tank (for the various periods of hydraulic retention), in the percolate from the lysimeters, and in the three types of soil. The microbiological analyses were carried out using the membrane filter technique. The pH analyses were done potentiometrically. Results. For the three microorganisms, the largest decrease in bacterial counts in the storage tanks occurred with 90 or 120 days of retention. There was a marked decrease in the bacterial count in the percolates of the three soils. For the three soil types the greatest reduction in bacterial counts was found in medium soil, due to its acidity (pH < 7.0). Hydraulic retention was not sufficient to ensure the sanitary adequacy of the wastewaters and their use for irrigation, given that fecal coliform values were above 1 000 CFU per 100 mL. Therefore, adding the residues to the soil was considered a second stage of treatment. Conclusions. The retention of wastewaters followed by adding them to soil was effective in minimizing the contaminating effect of pig farming residues. The storage time for wastewaters from pig farming could be decreased from 120 to 90 days.
Resumo:
GCTase production by a new strain of Bacillus alkalophillc CGII isolated from Brazilian wastewater of manioc flour industry was examined. The growth medium used was composed by 1.5% starch, 1.5% nitrogen and 1% Na 2CO3. Higher activity was obtained with starch, maltodextrin and galactose. When glucose was added to the medium, no enzyme production was observed. High enzyme activity and growth were reached when aeration was increased (88.6 U/mL). The enzyme characterization showed an optimum pH and temperature 8.0 and 55°C for starch hydrolyses, respectively. Mg+ and Ca++ showed small activation; however, Hg + and Cu+ showed a strong enzyme inhibition.
Resumo:
A Streptomyces was isolated from poultry plant wastewater, showed high keratinolytic activity when cultured on feather meal medium. Optimum keratinolytic activity was observed at 40°C and pH 8.0. The enzyme also showed to be stable between 40 and 60°C. The keratinolytic activity was not inhibited by EDTA, DMSO and Tween 80. On the other hand, CaCl2, ZnCl2, and BaCl2 slightly inhibited the keratinolytic activity. The Streptomyces isolated might be useful in leather, keratin waste treatment, animal feeding industry, and also cosmetic industry. © 2008 Academic Journals.
Resumo:
Physical and chemical variables of soil and water were measured to determine the effectiveness of a constructed wetland for wastewater treatment. Eight different macrophyte species, namely Eichhornia crassipes, Alternanthera philoxerodos, Heteranthera reniformis, Hydrocotyle umbeliferae, Lidwigia elegan, Ludwigia sericea, Myriophyllum aquaticum and Thypha domingensis, were transplanted. Inlet water and outlet water were the two sampling sites evaluated. There were significant differences (p < 0,05) when limnological characteristics between inlet and outlet water from the constructed wetland were compared. In general, dissolved oxygen was over 4 mg L-1, and conductivity was high, above 80 μS cm-1. Chlorophyll-a levels generally tended to decrease at the wetland outlet and were higher during the rainy period (fish growth period). Results show that ammonia, total phosphorus, BOD5, phosphorus and organic mattel in the sediment removals in the constructed wetland were higher, indicating that macrophytes played an important role in removing these variables. The use of constructed wetland is a viable technology for the biological treatment in aquaculture and swine wastewater.
Resumo:
In this work, the efficiency of two-stage upflow anaerobic sludge blanket (UASB) reactors was evaluated in bench scale, for treating a liquid effluent from coffee pulping. Hydraulic detention times (HDT) were 4.0; 5.2 and 6.2 days, resulting in organic loading rates (OLR) of 5.8; 3.6 and 3.0g total COD per (L-d) in the first reactor (Rl) and HDT of 2.0; 2.6 and 3.1 days with OLR of 5.8; 0.5 and 0.4 g total COD per (L-d) in the second reactor (R2). The medium values of total COD affluent varied from 15.440 to 23.040 mg O 2/L, and in the effluent to the reactors 1 and 2 were from l.lOO to 11.500 mg 0 2/L and 420 to 9.000 mg O 2/L, respectively. The medium values of removal efficiencies of total COD and TSS varied from 66 to 98% and 93 to 97%, respectively, in the system of treatment with the UASB reactors, in two stages. The content of methane in the biogas varied from 69 to 89% in the Rl and from 52 to 73% in the R2. The maximum volumetric methane production of 0.483 m 3 CH 4per (m 3 reactor d) was obtained with OLR of 3.6 g total COD per (L reactor d) and HDT of 6.2 days in the Rl. The volatile fatty acids concentration was kept below 100mg/L with HDT of 5.2 and 6.2 days in the Rl and HDT of 2.6 and 3.1 days in the R2.
Resumo:
This research aimed to compare the development of four grasses species irrigated by dripping with an effluent from a domestic wastewater station treatment in a small rural community, and supply water from Sabesp. For this purpose, an experiment was conducted in a greenhouse at the FCA/UNESP (Botucatu - SP) for 12 months in a completely randomized 4 × 3 factorial design, with four replications, totalizing 48 parcels. Grass species used in this experiment were: Santo Agostinho (Stenotaphrum secandatum (Walt.) Kuntze); Bermudas (Cynodum dactylon); Esmeralda (Zoysia japônica) and São Carlos (Axnopus sp). The treatments were: T1- Irrigation with re-use; T2- Irrigation with re-use + chemical fertilization and T3- Irrigation with supply water from Sabesp + chemical fertilization (control). Data were submitted to comparison of means by Tukey's test at 5 %. The results showed that nitrogen in the wastewater was enough for the good development of the grass species. However, its use caused higher potassium loss.
Resumo:
This paper aimed to determine the flow rate of drippers, their flow rate-pressure curve, their equation, their flow rate variation coefficient (VCq), as well as to evaluate the uniformity of water application of the Netafim drip pipe, Tiran 17 model, used for irrigation with domestic wastewater from treated household drain. After 1000 working hours, the blockage of some drippers decreased the uniformity of water application from 98% to lower than 60% and increased the flow variation coefficient to values higher than 0.29.