985 resultados para ventricular tachycardia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Heart transplant rejection originates slow and fragmented conduction. Signal-averaged ECG (SAECG) is a stratification method in the risk of rejection. Objective: To develop a risk score for rejection, using SAECG variables. Methods: We studied 28 transplant patients. First, we divided the sample into two groups based on the occurrence of acute rejection (5 with rejection and 23 without). In a second phase, we divided the sample considering the existence or not of rejection in at least one biopsy performed on the follow-up period (rejection pm1: 18 with rejection and 10 without). Results: On conventional ECG, the presence of fibrosis was the only criterion associated with acute rejection (OR = 19; 95% CI = 1.65-218.47; p = 0.02). Considering the rejection pm1, an association was found with the SAECG variables, mainly with RMS40 (OR = 0.97; 95% CI = 0.87-0.99; p = 0.03) and LAS40 (OR = 1.06; 95% IC = 1.01-1.11; p = 0.03). We formulated a risk score including those variables, and evaluated its discriminative performance in our sample. The presence of fibrosis with increasing of LAS40 and decreasing of RMS40 showed a good ability to distinguish between patients with and without rejection (AUC = 0.82; p < 0.01), assuming a cutoff point of sensitivity = 83.3% and specificity = 60%. Conclusion: The SAECG distinguished between patients with and without rejection. The usefulness of the proposed risk score must be demonstrated in larger follow-up studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Accurate placement of an external ventricular drain (EVD) for the treatment of hydrocephalus is of paramount importance for its functionality and in order to minimize morbidity and complications. The aim of this study was to compare two different drain insertion assistance tools with the traditional free-hand anatomical landmark method, and to measure efficacy, safety and precision. METHODS: Ten cadaver heads were prepared by opening large bone windows centered on Kocher's points on both sides. Nineteen physicians, divided in two groups (trainees and board certified neurosurgeons) performed EVD insertions. The target for the ventricular drain tip was the ipsilateral foramen of Monro. Each participant inserted the external ventricular catheter in three different ways: 1) free-hand by anatomical landmarks, 2) neuronavigation-assisted (NN), and 3) XperCT-guided (XCT). The number of ventricular hits and dangerous trajectories; time to proceed; radiation exposure of patients and physicians; distance of the catheter tip to target and size of deviations projected in the orthogonal plans were measured and compared. RESULTS: Insertion using XCT increased the probability of ventricular puncture from 69.2 to 90.2 % (p = 0.02). Non-assisted placements were significantly less precise (catheter tip to target distance 14.3 ± 7.4 mm versus 9.6 ± 7.2 mm, p = 0.0003). The insertion time to proceed increased from 3.04 ± 2.06 min. to 7.3 ± 3.6 min. (p < 0.001). The X-ray exposure for XCT was 32.23 mSv, but could be reduced to 13.9 mSv if patients were initially imaged in the hybrid-operating suite. No supplementary radiation exposure is needed for NN if patients are imaged according to a navigation protocol initially. CONCLUSION: This ex vivo study demonstrates a significantly improved accuracy and safety using either NN or XCT-assisted methods. Therefore, efforts should be undertaken to implement these new technologies into daily clinical practice. However, the accuracy versus urgency of an EVD placement has to be balanced, as the image-guided insertion technique will implicate a longer preparation time due to a specific image acquisition and trajectory planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'hypertrophie ventriculaire pathologique chez les nouveau-nés des mères diabétiques une étude rétrospective RESUME Objectif L'incidence du diabète chez les femmes enceintes ne cesse de croître, de même que les complications chez leurs nouveau-nés. C'est pourquoi, nous avons étudié la population de mères diabétiques suivies dans notre établissement entre les années 2003-2005 dans le but d'analyser spécifiquement le problème d'hypertrophie ventriculaire pathologique (HVP) chez les nouveau-nés de cette population. Méthode et résultats Dans notre étude rétrospective comprenant 87 grossesses de femmes diabétiques (92 nouveau-nés), 16 présentaient un diabète de type 1, 17 de type 2 et 54 ont développé un diabète gestationnel (DG). Le médian des hémoglobines glycquées (HbAlc) pour cette population est de 5.8% (5.3-6.5) : 17 avaient une HbAlc au-dessus de la norme, dont 2 souffrant d'une cardiomyopathie congénitale (CMC) et six d'une HVP. Un total de 75 nouveaux-nés étaient normaux, cinq avaient une CMC et 12 une HVP (1/12 décédé post-natalement, 1/12 mort-né, 2/12 nécessitant un accouchement prématuré, 8/12 normaux). Les 16 mères avec un diabète de type 1 accouchèrent de trois nouveau-nés avec une CMC et de 50% avec une HVP, comprenant un enfant décédé et un prématuré né par césarienne à cause d'une HVP. Dans le groupe des 17 nouveau-nés issus d'une mère connue pour un diabète de type 2, un cas présentait une CMC et 25% des cas une HVP. Parmi les 54 grossesses avec un DG, on dénombre un cas de CMC et un cas de HVP. Conclusion Les grossesses de mères souffrant d'un diabète de type 1 et de type 2 comportent toutes deux un risque augmenté de développement d'une HVP comparées à celles de mères ayant développé un diabète gestationnel. Les contrôles glycémiques sont insuffisants pour éviter la survenue d'une HVP. Comme aucun autre paramètre prédictif n'a pu été défini jusqu'alors, nous concluons qu'un suivi échographique rapproché de ces grossesses peut prévenir des complications périnatales sévères.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Manifestations of external ventricular drain (EVD) - associated infections overlap with those of the underlying neurosurgical conditions. We analyzed characteristics of EVD-associated infections. METHODS: We included patients aged ≥18 years with EVD-associated infections from 1997 to 2008, using modified CDC criteria for nosocomial infections. Hospital charts were reviewed retrospectively and the in-hospital outcome was evaluated. RESULTS: Forty-eight patients with EVD-associated infections were included (median age, 52 years, range 20-74 years). The median EVD-indwelling time was 7 days (range, 1-39 days) and EVD-associated infection occurred 6 days after insertion (range, 1-17 days). In 23% of patients, meningitis occurred 1-10 days after EVD removal. Fever >38 °C was present in 79% of patients, but Glasgow Coma Scale (GCS) scores were reduced in only 29%, and headache, vomiting and/or neck stiffness were present in only 31%. The median cerebrospinal fluid (CSF) leukocyte count was higher at onset of EVD-associated infection than at EVD insertion (175 × 10(6)/l versus 46 × 10(6)/l, p = 0.021), but other CSF parameters did not differ significantly. The most commonly implicated organisms were coagulase-negative staphylococci (63%) and Propionibacterium acnes (15%). CONCLUSIONS: Fever and increased CSF leukocytes should raise the suspicion of EVD-associated infection, which may occur up to 10 days after removal of EVD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Surgical correction of complete atrio-ventricular septal defect (AVSD) achieves satisfactory results with low morbidity and mortality, but may require reoperation. Our recent operative results at mid-term were followed-up. METHODS: From June 2000 to December 2007, 81 patients (Down syndrome; n=60), median age 4.0 months (range 0.7-118.6) and weight 4.7kg (range 2.2-33), underwent complete AVSD correction. Patch closure for the ventricular septal defect (VSD; n=69) and atrial septal defect (ASD; n=42) was performed with left atrio-ventricular valve (LAVV) cleft closure (n=76) and right atrio-ventricular valve (RAVV) repair (n=57). Mortality, morbidity, and indications for reoperation were retrospectively studied; the end point 'time to reoperation' was analyzed using Kaplan-Meier curves. Follow-up was complete except in two patients and spanned a median of 28 months (range 0.4-6.1 years). RESULTS: In-hospital mortality was 3.7% (n=3) and one late death occurred. Reoperation was required in 7/79 patients (8.9%) for LAVV insufficiency (n=4), for a residual ASD (n=1), for right atrio-ventricular valve insufficiency (n=1), and for subaortic stenosis (n=1). At last follow-up, no or only mild LAVV and RAVV insufficiency was present in 81.3% and 92.1% of patients, respectively, and 2/3 of patients were medication-free. Risk factors for reoperation were younger age (<3 months; p=0.001) and lower weight (<4kg; p=0.003), and a trend towards less and later reoperations in Down syndrome (p<0.2). CONCLUSIONS: Surgical correction of AVSD can be achieved with low mortality and need for reoperation, regardless of Down syndrome or not. Immediate postoperative moderate or more residual atrio-ventricular valve insufficiency will eventually require a reoperation, and could be anticipated in patients younger than 3 months and weighing <4kg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision. Methods: Retrospective analysis of 75 patients who received TPLVAD to treat cardiogenic shock (n = 49) or to facilitate high-risk percutaneous coronary intervention (PCI) (n = 26). Forty-two patients with cardiogenic shock and 16 patients with high-risk PCI received a TandemHeart and 7 patients and 10 patients, respectively, received an Impella Recover LP 2.5. Outcome and related complications up to 1 month are reported with reference to device depending function. Results: One-month survival was 53% in patients with shock and 96% in patients with PCI. Conclusion: TPLVADs can support the failing heart with acceptable risk. Outcome is better in prophylactic use than in patients with cardiogenic shock. (C) 2011 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our experience with the Sapien trans-apical aortic valve (Edwards Lifesciences Inc., Irvine, CA, USA) has been straightforward without per-procedural mortality except in 1/16 consecutive cases who developed non-apical haemorrhage early after valve implantation. We describe the case of an 84-year-old female carrying a very high operative risk (logistic EuroScore of 44%), who underwent a trans-apical stent-valve implantation for severe and symptomatic aortic valve stenosis (23 mm). Due to massive blood loss, an emergency sternotomy and cannulation for cardiopulmonary bypass resuscitation were necessary to treat (without success) an unusual and unexpected subaortic left ventricular free-wall rupture that occurred few minutes after the stent-valve positioning and implantation. To the best of our knowledge, this is the first described case of a left ventricular free-wall rupture occurring after an otherwise non-complicated standard catheter-based aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intracoronary injection of autologous bone marrow-derived mononucleated cells (BM-MNC) may improve LV function shortly after acute ST elevation myocardial infarction (STEMI), but little is known about the long-term durability of the treatment effect. METHODS: In a single-centre trial a total of 60 patients with acute anterior STEMI, successful reperfusion therapy and a left ventricular ejection fraction (LVEF) of <50% were screened for the study. 23 patients were actively treated with intracoronary infusion of BM-MNC within a median of 3 days. The open-label control group consisted of 19 patients who did not consent to undergo BM-MNC treatment but agreed to undergo regular clinical and echocardiographic follow-up for up to 5 years after AMI. RESULTS: Whereas at 4 months there was no significant difference between the increase in LVEF in the BM-MNC group and the control group (+7.0%, 95%CI 3.6; 10.4) vs. +3.9%, 95%CI -2.1; 10), the absolute increase at 5 years remained stable in the BM-MNC but not in the control group (+7.95%, 95%CI 3.5; 12.4 vs. -0.5%, 95%CI -5.4; 4.4; p for interaction between groups = 0.035). DISCUSSION: In this single-centre, open-labelled study, intracoronary administration of BM-MNC is feasible and safe in the short term. It is also associated with sustained improvement of left ventricular function in patients with acute myocardial infarction, encouraging phase III studies to examine the potential BM-MNC effect on clinical outcome.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La insuficiencia pulmonar después de la reparación de la Tetralogía de Fallot ocasiona una dilatación del ventrículo derecho, IT y/o empeoramiento de la CF. El momento de la cirugía viene marcado por la presencia de la clínica y/o dilatación ventrículo derecho. El motivo del presente estudio es realizar una revisión de los pacientes sometidos a sustitución valvular pulmonar, un seguimiento clínico y ecocardiográfico. MÉTODOS Desde enero 2003 a enero 2009, 33 pacientes fueron sometidos a una cirugía de sustitución valvular pulmonar. El 41 % de los pacientes fueron mujeres y el 59 % varones. La edad media de los pacientes fue de 31,3 años, ( 18 - 63 a ). La edad media de la primera intervención fue a los 3,8 años ( 6 meses – 28 años ). Sólo un paciente no había sido sometido a ningún tipo de intervención en la infancia, realizándose una cirugía paliativa – correctora a los 28 años. La indicación de intervención quirúrgica vino marcada por la presencia de clínica en 11 pacientes ( 37 %) y por dilatación VD, ( única o asintomática) en 18 pacientes ( 62%). RESULTADOS No hubo mortalidad operatoria con una estancia media post IQ de 15,21 días ( 9- 27 días). Se analizan los resultados quirúrgicos de estos pacientes a tres niveles: Clínica y tolerancia al esfuerzo en postoperatorio inmediato y tardío. Eventos arrítmicos en el postoperatorio inmediato y seguimiento y Parámetros ecocardiográficos en postoperatorio inmediato y tardío. (Dimensiones cavidades derechas y función contráctil del VD ( TAPSE )).En el seguimiento al año de la intervención ningún paciente presentaba clínica de IP. El 67 % de los pacientes fueron intervenidos manteniéndose asintomáticos con un 37% ( 11 pacientes ) de eventos arrítmicos pre cirugía ( 9 ; 31 % pacientes) fueron sometidos a ablación precirugía y 3 pacientes ( 10 %) requirieron implante de un dispositivo DAI. Después de la cirugía el 86 % de los pacientes, 24 pacientes, se mantenían en CF I; 3 pacientes ( 10 %) continuaron presentando eventos arrítmicos y un solo paciente requirió implante de DAI. El remodelado del VD al año y medio de seguimiento presentó una reducción del 11 % respecto al diámetro teledistólico precirugía ( DTDV x 54,43 ( 41-70 mm), postcirugía ( DTDV x 44,29 ( 32-61), p ≤ 0,01; sin encontrar diferencias significativas en la reducción del dTS pre/postcirugía. La función del VD ( TAPSE pre IQ 16,35 ( 13-229;postcirugía inmediata 15,54 ( 11-23) y al año 17,5. El gradiente medio es inferior al 15 mmHg en el 84 % de los pacientes portadores de válvula biológica. 11 pacientes ≤ 11 mmHg ( 44 %); 10 pacientes ≤ 15 mm Hg ( 40 %). CONCLUSIONES En este estudio realizado en el Hospital Vall d’Hebron, la sustitución valvular pulmonar en pacientes afectos de una Tetralogía de Fallot mejora los diámetros ventriculares, la función contráctil y por lo tanto la capacidad funcional de los mismos. En los pacientes sometidos a Estudio electrofisiológicos que no presentaron inducción de eventos arrítmicos ventriculares, no han presentado episodios arrítmicos tras la cirugía de sustitución valvular pulmonar. Todos los pacientes se mantienen en Clase funcional I tras la cirugía y libres de reintervención con un seguimiento medio de 16,9 ( 5-33 ) meses. Los factores de riesgo para presentar una peor evolución son un retraso en la corrección inicial de la TOF y por lo tanto aparición de enfermedad pulmonar por hipertensión vascular subyacente, edad avanzada en el momento del PVR, deterioro funcional preoperatorio con Clase Funcional según NYHA ( III- IV), o bien aparición de eventos arrítmicos.