904 resultados para unintentional injection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml"* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h"^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l'l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml'l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of sample solvent composition and the injection volume, on the chromatographic peak profiles of two carbamate derivatives, methyl 2-benzimidazolecarbamate (MBC) and 3-butyl-2,4-dioxo[1,2-a]-s-triazinobenzimidazole (STB), were studied using reverse phase high performance liquid chromatograph. The study examined the effects of acetonitrile percentage in the sample solvent from 5 to 50%, effects of methanol percentage from 5 to 50%, effects of pH increase from 4.42 to 9.10, and effect of increasing buffer concentration from ° to 0.12M. The effects were studied at constant and increasing injection mass and at four injection volumes of 10, 50, 100 and 200 uL. The study demonstrated that the amount and the type of the organic solvents, the pH, and the buffer strength of the sample solution can have a pronounced effect on the peak heights, peak widths, and retention times of compounds analysed. MBC, which is capable of intramolecular hydrogen bonding and has no tendency to ionize, showed a predictable increase .in band broadening and a decrease in retention times at higher eluting strengths of the sample solvent. STB, which has a tendency to ionize or to strongly interact with the sample solvent, was influenced in various ways by the changes in ths sample solvent composition. The sample solvent effects became more pronounced as the injection volume increased and as the percentage of organic solvent in the sample solution became greater. The peak height increases for STB at increasing buffer concentrations became much more pronounced at higher analyte concentrations. It was shown that the widely accepted procedure of dissolving samples in the mobile phase does not yield the most efficient chromatograms. For that reason samples should be dissolved in the solutions with higher aqueous content than that of the mobile phase whenever possible. The results strongly recommend that all the samples and standards, regardless whether the standards are external or internal, be analysed at a constant sample composition and a constant injection volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I - Fluorinated Compounds A method has been developed for the extraction, concentration, and determination of two unique fluorinated compounds from the sediments of Lake Ontario. These compounds originated from a common industrial landfill, and have been carried to Lake Ontario by the Niagara River. Sediment samples from the Mississauga basin of Lake Ontario have been evaluated for these compounds and a depositional trend was established. The sediments were extracted by accelerated solvent extraction (ASE) and then underwent clean-up, fractionation, solvent exchange, and were concentrated by reduction under nitrogen gas. The concentrated extracts were analyzed by gas chromatography - electron capture negative ionization - mass spectrometry. The depositional profile determined here is reflective of the operation of the landfill and shows that these compounds are still found at concentrations well above background levels. These increased levels have been attributed to physical disturbances of previously deposited contaminated sediments, and probable continued leaching from the dumpsite. Part II - Polycyclic Aromatic Hydrocarbons Gas chromatography/mass spectrometry is the most common method for the determination of polycyclic aromatic hydrocarbons (PAHs) from various matrices. Mass discrimination of high-boiling compounds in gas chromatographic methods is well known. The use of high-boiling injection solvents shows substantial increase in the response of late-eluting peaks. These solvents have an increased efficiently in the transfer of solutes from the injector to the analytical column. The effect of I-butanol, I-pentanol, cyclopentanol, I-hexanol, toluene and n-octane, as injection solvents, was studied. Higher-boiling solvents yield increased response for all PAHs. I -Hexanol is the best solvent, in terms of P AH response, but in this solvent P AHs were more susceptible to chromatographic problems such as peak splitting and tailing. Toluene was found to be the most forgiving solvent in terms of peak symmetry and response. It offered the smallest discrepancies in response, and symmetry over a wide range of initial column temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias de la Ingeniería Eléctrica con Especialidad en Control Automático) UANL, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ce document est la pré-publication d'un article paru dans AIDS and Behavior 2011; 15(1): 75-85 url: http://link.springer.com/journal/volumesAndIssues/10461

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ce manuscrit est une pré-publication d'un article paru dans International Journal of Drug Policy 2010; 21(1): 49-55.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ce manuscrit est une pré-publication d'un article paru dans International Journal of Drug Policy 2010; 21(6): 477-484.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ce manuscrit est une pré-publication d'un article paru dans Addiction 2012; 107(7): 1318-1327 url: http://www.addictionjournal.org/

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ce manuscrit est une pré-publication d'un article paru dans The American Journal on Addictions 2010; 19(3): 231-237 url: http://onlinelibrary.wiley.com/doi/10.1111/ajad.2010.19.issue-3/issuetoc

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Malgré des taux d’efficacité comparable du traitement antiviral de l’hépatite C (VHC) entre utilisateurs de drogues par injection (UDIs) et non-UDIs, il y a encore d’importantes barrières à l’accessibilité au traitement pour cette population vulnérable. La méfiance des UDIs à l’égard des autorités médicales, ainsi que leur mode de vie souvent désorganisé ont un impact sur l’initiation du traitement. L’objectif de cette étude est d’examiner les liens entre l’initiation du traitement du VHC et l’utilisation des services de santé chez les UDIs actifs. Methode: 758 UDIs actifs et séropositifs aux anticorps anti-VHC ont été interrogés durant la période de novembre 2004 à mars 2011, dans la région de Montréal. Des questionnaires administrés par des intervieweurs ont fourni des informations sur les caractéristiques socio-économiques, ainsi que sur les variables relatives à l’usage de drogues et à l’utilisation des services de santé. Des échantillons sanguins ont été prélevés et testés pour les anticorps anti-VHC. Une régression logistique multivariée a permis de générer des associations entre les facteurs relatifs aux services de santé et l’initiation du traitement contre le VHC. Resultats: Parmi les 758 sujets, 55 (7,3%) avaient initié un traitement du VHC avant leur inclusion dans l’étude. Selon les analyses multivariées, les variables significativement associées à l’initiation du traitement sont les suivantes: avoir vu un médecin de famille dans les derniers 6 mois (Ratio de Cote ajusté (RCa): 1,96; Intervalle de Confiance à 95% (IC): 1,04-3,69); plus de 2 ans sous traitement de la dépendance à vie, sans usage actuel de méthadone (RCa: 2,25; IC: 1,12-4,51); plus de 2 ans sous traitement de la dépendance à vie, avec usage actuel de méthadone (RCa: 3,78; IC: 1,85-7,71); et avoir déjà séjourné en prison (RCa: 0,44; IC: 0,22-0,87). Conclusion: L’exposition à des services d’aide à la dépendance et aux services médicaux est associée à l’initiation du traitement du VHC. Ces résultats suggèrent que ces services jouent leur rôle de point d’entrée au traitement. Alternativement, les UDIs ayant initié un traitement du VHC, auraient possiblement adopté une attitude proactive quant à l'amélioration de leur santé globale. D’autre part, l’incarcération ressort comme un obstacle à la gestion de l’infection au VHC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research project aimed to conduct a strategic analysis of the implementation of a supervised injecting facility (SIF) in Montérégie. Using a mixed design, we first completed a portrait of the injection drug user (IDU) population. We then explored the perceptions of IDU and stakeholders with regard to the relevance of implementing a SIF in the region. Although some similarities were found with the IDU populations of Montreal and the province of Quebec, this population in Montérégie is characterized by a lower frequency of injections in public, less homeless people and lower rates of HIV and HCV infections. Despite these differences, the IDU population in Montérégie was found to have important physical and psychosocial needs. Although the relevance of a SIF in Montérégie is undeniable, improvements regarding the accessibility, continuity and appreciation of the actual services dedicated to IDU remain a priority.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis presented here unveils an experimental study of the hydrodynamic characteristics of swirling fluidized bed viz. pressure drop across the distributor and the bed, minimum fluidizing velocity, bed behaviour and angle of air injection. In swirling fluidized bed the air is admitted to the bed at an angle 'Ѳ' to the horizontal. The vertical component of the velocity v sin Ѳ causes fluidization and the horizontal component v cos Ѳ contributes to swirl motion of the bed material.The study was conducted using spherical particles having sizes 3.2 mm, 5.5 mm & 7.4 mm as the bed materials. Each of these particles was made from high density polyethylene, nylon and acetal having relative densities of 0.93, 1.05 and 1.47 respectively.The experiments were conducted using conidour type distributors having four rows of slits. Altogether four distributors having angles of air injection (Φ)- 0°, 5°, 10° & 15° were designed and fabricated for the study. The total number of slits in each distributor was 144. The area of opening was 6220 mm2 making the percentage area of opening to 9.17. But the percentage useful area of opening of the distributor was 96.The experiments on the variation of distributor pressure drop with superficial velocity revealed that the distributor pressure drop decreases with angle of air injection. Investigations related to bed hydrodynamics were conducted using 2.5 kg of bed material. The bed pressure drop measurements were made along the radial direction of the distributor at distances of 60 mm, 90 mm, 120 mm & 150 mm from the centre of the distributor. It was noticed that after attaining minimum fluidizing velocity, the bed pressure drop increases along the radial direction of the distributor. But at a radial distance of 90 mm from the distributor centre, after attaining minimum fluidizing velocity the bed pressure drop remains almost constant. It was also observed that the bed pressure drop varies inversely with particle size as well as particle density.An attempt was made to determine the effect of various parameters on minimum fluidizing velocity. It was noticed that the minimum fluidizing velocity varies directly with angle of air injection (Φ), particle size and particle density.The study on the bed behaviour showed that the superficial velocity required for initiating various bed phenomena (such as swirl motion and separation of particles from the cone at the centre) increase with increase in particle size as well as particle density. It was also observed that the particle size and particle density directly influence the superficial velocity required for various regimes of bed behaviour such as linear variation of bed pressure drop, constant bed pressure drop and sudden increase or decrease in bed pressure drop.Experiments were also performed to study the effect of angle of air injection (Φ). It was noticed that the bed pressure drop decreases with angle of air injection. It was also noticed that the angle of air injection directly influence the superficial velocity required for initiating various bed phenomena as well as the various regimes of bed behaviour.