895 resultados para time and movements
Resumo:
Introduction: The aim of this study was to assess the influence of curing time and power on the degree of conversion and surface microhardness of 3 orthodontic composites. Methods: One hundred eighty discs, 6 mm in diameter, were divided into 3 groups of 60 samples according to the composite used-Transbond XT (3M Unitek, Monrovia, Calif), Opal Bond MV (Ultradent, South Jordan, Utah), and Transbond Plus Color Change (3M Unitek)-and each group was further divided into 3 subgroups (n = 20). Five samples were used to measure conversion, and 15 were used to measure microhardness. A light-emitting diode curing unit with multiwavelength emission of broad light was used for curing at 3 power levels (530, 760, and 1520 mW) and 3 times (8.5, 6, and 3 seconds), always totaling 4.56 joules. Five specimens from each subgroup were ground and mixed with potassium bromide to produce 8-mm tablets to be compared with 5 others made similarly with the respective noncured composite. These were placed into a spectrometer, and software was used for analysis. A microhardness tester was used to take Knoop hardness (KHN) measurements in 15 discs of each subgroup. The data were analyzed with 2 analysis of variance tests at 2 levels. Results: Differences were found in the conversion degree of the composites cured at different times and powers (P < 0.01). The composites showed similar degrees of conversion when light cured at 8.5 seconds (80.7%) and 6 seconds (79.0%), but not at 3 seconds (75.0%). The conversion degrees of the composites were different, with group 3 (87.2%) higher than group 2 (83.5%), which was higher than group 1 (64.0%). Differences in microhardness were also found (P < 0.01), with lower microhardness at 8.5 seconds (35.2 KHN), but no difference was observed between 6 seconds (41.6 KHN) and 3 seconds (42.8 KHN). Group 3 had the highest surface microhardness (35.9 KHN) compared with group 2 (33.7 KHN) and group 1 (30.0 KHN). Conclusions: Curing time can be reduced up to 6 seconds by increasing the power, with a slight decrease in the degree of conversion at 3 seconds; the decrease has a positive effect on the surface microhardness.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The relationship between diastolic blood pressure and the variables total cumulative working time and age was examined by regression analysis. The study was carried out among 839 bus drivers and conductors, users of an occupational health center in Campinas, S. Paulo State, Brazil. The main results were a positive association between diastolic blood pressure and cumulative working time, as well as an interaction between this variable and the bus worker's age.
Resumo:
To analyse the associations between high screen time and overweight, poor dietary habits and physical activity in adolescents according to sex. The study comprised 515 boys and 716 girls aged 14-17 years from Londrina, Brazil. Nutritional status (normal weight or overweight/obese) was assessed by calculating the body mass index. Eating habits and time spent in physical activity were reported using a questionnaire. The measurement of screen time considered the time spent watching television, using a computer and playing video games during a normal week. Associations between high screen time and dependent variables (nutritional status, eating habits and physical activity levels) were assessed by binary logistic regression, adjusted for sociodemographic and lifestyle variables. Most adolescents (93.8% of boys and 87.2% of girls) spent more than 2 hours per day in screen-time activities. After adjustments, an increasing trend in the prevalence of overweight and physical inactivity with increasing time spent on screen activities was observed for both sexes. Screen times of >4 hours/day compared with <2 hours/day were associated with physical inactivity, low consumption of vegetables and high consumption of sweets only in girls and the consumption of soft drinks in both sexes. The frequency of overweight and physical inactivity increased with increasing screen time in a trending manner and independently of the main confounders. The relationship between high screen time and poor eating habits was particularly relevant for adolescent girls.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: To determine the micro-hardness profile of two dual cure resin cements (RelyX - U100 (R), 3M-ESPE and Panavia F 2.0 (R), Kuraray) used for cementing fiber-reinforced resin posts (Fibrekor (R) - Jeneric Pentron) under three different curing protocols and two water storage times. Material and methods: Sixty 16mm long bovine incisor roots were endodontically treated and prepared for cementation of the Fibrekor posts. The cements were mixed as instructed, dispensed in the canal, the posts were seated and the curing performed as follows: a) no light activation; b) light-activation immediately after seating the post, and; c) light-activation delayed 5 minutes after seating the post. The teeth were stored in water and retrieved for analysis after 7 days and 3 months. The roots were longitudinally sectioned and the microhardness was determined at the cervical, middle and apical regions along the cement line. The data was analyzed by the three-way ANOVA test (curing mode, storage time and thirds) for each cement. The Tukey test was used for the post-hoc analysis. Results: Light-activation resulted in a significant increase in the microhardness. This was more evident for the cervical region and for the Panavia cement. Storage in water for 3 months caused a reduction of the micro-hardness for both cements. The U100 cement showed less variation in the micro-hardness regardless of the curing protocol and storage time. Conclusions: The micro-hardness of the cements was affected by the curing and storage variables and were material-dependent.
Resumo:
L. Antonangelo, F. S. Vargas, M. M. P. Acencio, A. P. Cora, L. R. Teixeira, E. H. Genofre and R. K. B. Sales Effect of temperature and storage time on cellular analysis of fresh pleural fluid samples Objective: Despite the methodological variability in preparation techniques for pleural fluid cytology, it is fundamental that the cells should be preserved, permitting adequate morphological classification. We evaluated numerical and morphological changes in pleural fluid specimens processed after storage at room temperature or under refrigeration. Methods: Aliquots of pleural fluid from 30 patients, collected in ethylenediaminetetraacetic acid-coated tubes and maintained at room temperature (21 degrees C) or refrigeration (4 degrees C) were evaluated after 2 and 6 hours and 1, 2, 3, 4, 7 and 14 days. Evaluation of cytomorphology and global and percentage counts of leucocytes, macrophages and mesothelial cells were included. Results: The samples had quantitative cellular variations from day 3 or 4 onwards, depending on the storage conditions. Morphological alterations occurred earlier in samples maintained at room temperature (day 2) than in those under refrigeration (day 4). Conclusions: This study confirms that storage time and temperature are potential pre-analytical causes of error in pleural fluid cytology.
Resumo:
Activity and behavior patterns are important components of a given species ecological strategy, as they have profound implications for its survival and reproduction. Here, we studied the activities, movements and secretive behavior of the thin-spined porcupine Chaetomys subspinosus (Rodentia: Erethizontidae), a threatened arboreal folivore in the Brazilian Atlantic rainforest. We aimed to ascertain the behavioral strategies used by this species as well as its responses to seasonal and daily climatic changes. Four radio-collared individuals were followed continuously for 72-h in the summer and winter, as well as during 146 half-night sessions conducted from April 2005 to September 2006 in forest remnants in southern Bahia. The thin-spined porcupines were nocturnally active (17:30-05:40 h), with peaks in activity and movement from 19:00 to 20:00 h and 03:00 to 04:00 h. Animals followed a circadian rhythm of activity during both the summer and winter. During the diel cycle, porcupines spent 74% of their time resting, 14% feeding, 11% traveling and 2% performing other activities. Distance traveled during the diel cycle averaged 277.5 +/- 117.9 m sd. The mean movement rate during the night was 21.6 +/- 30.1 m/h sd. No significant changes in activity budget or daily distance traveled were observed between seasons, most likely in response to the low fluctuations in climatic conditions and food availability throughout the year in the study region. However, rainfall reduced the time that the animals spent on feeding activities and explained day-to-day differences in activity budgets. We also provide details about intraspecific interactions and defecation behavior. Our observations confirmed that thin-spined porcupines, similar to other folivorous species, present low activity levels and short daily movements, and have adopted various cryptic habits, such as nocturnality, a solitary lifestyle, the tendency to leave offspring alone most of the time and defecation in concealed latrines.
Resumo:
OBJECTIVE: To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. METHODS: Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories were established for total tourniquet time: <60, 61 to 90, 91 to 120, and >120 minutes. Three categories were defined for operative time: <120, 121 to 150, and >150 minutes. Between 7 and 12 days after surgery, the patients underwent ascending venography to evaluate the presence of distal or proximal deep vein thrombosis. We evaluated the association between the tourniquet time and total operative time and the occurrence of deep vein thrombosis after total knee arthroplasty. RESULTS: In total, 33 cases (42.3%) were positive for deep vein thrombosis; 13 (16.7%) cases involved the proximal type. We found no statistically significant difference in tourniquet time or operative time between patients with or without deep vein thrombosis. We did observe a higher frequency of proximal deep vein thrombosis in patients who underwent surgery lasting longer than 120 minutes. The mean total operative time was also higher in patients with proximal deep vein thrombosis. The tourniquet time did not significantly differ in these patients. CONCLUSION: We concluded that surgery lasting longer than 120 minutes increases the risk of proximal deep vein thrombosis.
Resumo:
In this paper, we consider the stochastic optimal control problem of discrete-time linear systems subject to Markov jumps and multiplicative noises under two criteria. The first one is an unconstrained mean-variance trade-off performance criterion along the time, and the second one is a minimum variance criterion along the time with constraints on the expected output. We present explicit conditions for the existence of an optimal control strategy for the problems, generalizing previous results in the literature. We conclude the paper by presenting a numerical example of a multi-period portfolio selection problem with regime switching in which it is desired to minimize the sum of the variances of the portfolio along the time under the restriction of keeping the expected value of the portfolio greater than some minimum values specified by the investor. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
To evaluate the biocompatibility and the setting time of Portland cement clinker with or without 2% or 5% calcium sulfate and MTA-CPM. Twenty-four mice (Rattus norvegicus) received subcutaneously polyethylene tubes filled with Portland cement clinker with or without 2% or 5% calcium sulfate and MTA. After 15, 30 and 60 days of implantation, the animals were killed and specimens were prepared for microscopic analysis. For evaluation of the setting time, each material was analyzed using Gilmore needles weighing 113.5 g and 456.5 g, according to the ASTM specification Number C266-08 guideline. Data were analyzed by ANOVA and Tukey's test for setting time and Kruskal-Wallis and Dunn test for biocompatibility at 5% significance level. Histologic observation showed no statistically significant difference of biocompatibility (p>0.05) among the materials in the subcutaneous tissues. For the setting time, clinker without calcium sulfate showed the shortest initial and final setting times (6.18 s/21.48 s), followed by clinker with 2% calcium sulfate (9.22 s/25.33 s), clinker with 5% calcium sulfate (10.06 s/42.46 s) and MTA (15.01 s/42.46 s). All the tested materials showed biocompatibility and the calcium sulfate absence shortened the initial and final setting times of the white Portland cement clinker
Resumo:
Organic electronics has grown enormously during the last decades driven by the encouraging results and the potentiality of these materials for allowing innovative applications, such as flexible-large-area displays, low-cost printable circuits, plastic solar cells and lab-on-a-chip devices. Moreover, their possible field of applications reaches from medicine, biotechnology, process control and environmental monitoring to defense and security requirements. However, a large number of questions regarding the mechanism of device operation remain unanswered. Along the most significant is the charge carrier transport in organic semiconductors, which is not yet well understood. Other example is the correlation between the morphology and the electrical response. Even if it is recognized that growth mode plays a crucial role into the performance of devices, it has not been exhaustively investigated. The main goal of this thesis was the finding of a correlation between growth modes, electrical properties and morphology in organic thin-film transistors (OTFTs). In order to study the thickness dependence of electrical performance in organic ultra-thin-film transistors, we have designed and developed a home-built experimental setup for performing real-time electrical monitoring and post-growth in situ electrical characterization techniques. We have grown pentacene TFTs under high vacuum conditions, varying systematically the deposition rate at a fixed room temperature. The drain source current IDS and the gate source current IGS were monitored in real-time; while a complete post-growth in situ electrical characterization was carried out. At the end, an ex situ morphological investigation was performed by using the atomic force microscope (AFM). In this work, we present the correlation for pentacene TFTs between growth conditions, Debye length and morphology (through the correlation length parameter). We have demonstrated that there is a layered charge carriers distribution, which is strongly dependent of the growth mode (i.e. rate deposition for a fixed temperature), leading to a variation of the conduction channel from 2 to 7 monolayers (MLs). We conciliate earlier reported results that were apparently contradictory. Our results made evident the necessity of reconsidering the concept of Debye length in a layered low-dimensional device. Additionally, we introduce by the first time a breakthrough technique. This technique makes evident the percolation of the first MLs on pentacene TFTs by monitoring the IGS in real-time, correlating morphological phenomena with the device electrical response. The present thesis is organized in the following five chapters. Chapter 1 makes an introduction to the organic electronics, illustrating the operation principle of TFTs. Chapter 2 presents the organic growth from theoretical and experimental points of view. The second part of this chapter presents the electrical characterization of OTFTs and the typical performance of pentacene devices is shown. In addition, we introduce a correcting technique for the reconstruction of measurements hampered by leakage current. In chapter 3, we describe in details the design and operation of our innovative home-built experimental setup for performing real-time and in situ electrical measurements. Some preliminary results and the breakthrough technique for correlating morphological and electrical changes are presented. Chapter 4 meets the most important results obtained in real-time and in situ conditions, which correlate growth conditions, electrical properties and morphology of pentacene TFTs. In chapter 5 we describe applicative experiments where the electrical performance of pentacene TFTs has been investigated in ambient conditions, in contact to water or aqueous solutions and, finally, in the detection of DNA concentration as label-free sensor, within the biosensing framework.
Resumo:
Visual search and oculomotor behaviour are believed to be very relevant for athlete performance, especially for sports requiring refined visuo-motor coordination skills. Modern coaches believe that a correct visuo-motor strategy may be part of advanced training programs. In this thesis two experiments are reported in which gaze behaviour of expert and novice athletes were investigated while they were doing a real sport specific task. The experiments concern two different sports: judo and soccer. In each experiment, number of fixations, fixation locations and mean fixation duration (ms) were considered. An observational analysis was done at the end of the paper to see perceptual differences between near and far space. Purpose: The aim of the judo study was to delineate differences in gaze behaviour characteristics between a population of athletes and one of non athletes. Aspects specifically investigated were: search rate, search order and viewing time across different conditions in a real-world task. The second study was aimed at identifying gaze behaviour in varsity soccer goalkeepers while facing a penalty kick executed with instep and inside foot. Then an attempt has been done to compare the gaze strategies of expert judoka and soccer goalkeepers in order to delineate possible differences related to the different conditions of reacting to events occurring in near (peripersonal) or far (extrapersonal) space. Judo Methods: A sample of 9 judoka (black belt) and 11 near judoka (white belt) were studied. Eye movements were recorded at 500Hz using a video based eye tracker (EyeLink II). Each subject participated in 40 sessions for about 40 minutes. Gaze behaviour was considered as average number of locations fixated per trial, the average number of fixations per trial, and mean fixation duration. Soccer Methods: Seven (n = 7) intermediate level male volunteered for the experiment. The kickers and goalkeepers, had at least varsity level soccer experience. The vision-in-action (VIA) system (Vickers 1996; Vickers 2007) was used to collect the coupled gaze and motor behaviours of the goalkeepers. This system integrated input from a mobile eye tracking system (Applied Sciences Laboratories) with an external video of the goalkeeper’s saving actions. The goalkeepers took 30 penalty kicks on a synthetic pitch in accordance with FIFA (2008) laws. Judo Results: Results indicate that experts group differed significantly from near expert for fixations duration, and number of fixations per trial. The expert judokas used a less exhaustive search strategy involving fewer fixations of longer duration than their novice counterparts and focused on central regions of the body. The results showed that in defence and attack situation expert group did a greater number of transitions with respect to their novice counterpart. Soccer Results: We found significant main effect for the number of locations fixated across outcome (goal/save) but not for foot contact (instep/inside). Participants spent more time fixating the areas in instep than inside kick and in goal than in save situation. Mean and standard error in search strategy as a result of foot contact and outcome indicate that the most gaze behaviour start and finish on ball interest areas. Conclusions: Expert goalkeepers tend to spend more time in inside-save than instep-save penalty, differences that was opposite in scored penalty kick. Judo results show that differences in visual behaviour related to the level of expertise appear mainly when the test presentation is continuous, last for a relatively long period of time and present a high level of uncertainty with regard to the chronology and the nature of events. Expert judoist performers “anchor” the fovea on central regions of the scene (lapel and face) while using peripheral vision to monitor opponents’ limb movements. The differences between judo and soccer gaze strategies are discussed on the light of physiological and neuropsychological differences between near and far space perception.
Resumo:
Among the experimental methods commonly used to define the behaviour of a full scale system, dynamic tests are the most complete and efficient procedures. A dynamic test is an experimental process, which would define a set of characteristic parameters of the dynamic behaviour of the system, such as natural frequencies of the structure, mode shapes and the corresponding modal damping values associated. An assessment of these modal characteristics can be used both to verify the theoretical assumptions of the project, to monitor the performance of the structural system during its operational use. The thesis is structured in the following chapters: The first introductive chapter recalls some basic notions of dynamics of structure, focusing the discussion on the problem of systems with multiply degrees of freedom (MDOF), which can represent a generic real system under study, when it is excited with harmonic force or in free vibration. The second chapter is entirely centred on to the problem of dynamic identification process of a structure, if it is subjected to an experimental test in forced vibrations. It first describes the construction of FRF through classical FFT of the recorded signal. A different method, also in the frequency domain, is subsequently introduced; it allows accurately to compute the FRF using the geometric characteristics of the ellipse that represents the direct input-output comparison. The two methods are compared and then the attention is focused on some advantages of the proposed methodology. The third chapter focuses on the study of real structures when they are subjected to experimental test, where the force is not known, like in an ambient or impact test. In this analysis we decided to use the CWT, which allows a simultaneous investigation in the time and frequency domain of a generic signal x(t). The CWT is first introduced to process free oscillations, with excellent results both in terms of frequencies, dampings and vibration modes. The application in the case of ambient vibrations defines accurate modal parameters of the system, although on the damping some important observations should be made. The fourth chapter is still on the problem of post processing data acquired after a vibration test, but this time through the application of discrete wavelet transform (DWT). In the first part the results obtained by the DWT are compared with those obtained by the application of CWT. Particular attention is given to the use of DWT as a tool for filtering the recorded signal, in fact in case of ambient vibrations the signals are often affected by the presence of a significant level of noise. The fifth chapter focuses on another important aspect of the identification process: the model updating. In this chapter, starting from the modal parameters obtained from some environmental vibration tests, performed by the University of Porto in 2008 and the University of Sheffild on the Humber Bridge in England, a FE model of the bridge is defined, in order to define what type of model is able to capture more accurately the real dynamic behaviour of the bridge. The sixth chapter outlines the necessary conclusions of the presented research. They concern the application of a method in the frequency domain in order to evaluate the modal parameters of a structure and its advantages, the advantages in applying a procedure based on the use of wavelet transforms in the process of identification in tests with unknown input and finally the problem of 3D modeling of systems with many degrees of freedom and with different types of uncertainty.