998 resultados para test device
Resumo:
Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.
Resumo:
The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.
Resumo:
The present study intended to analyze the seroprevalence of Helicobacter pylori, IgG, and its relation to dyspepsia in a population from the western Amazon region. During the "Projeto Bandeira Científica", a University of São Paulo Medical School program, in Monte Negro's rural areas, state of Rondônia, 266 blood samples were collected from volunteers. The material was tested for IgG antibodies anti-Helicobacter pylori by ELISA method and the participants were also interviewed on dyspepsia, hygiene and social aspects. Participants aged between five and 81 years old (34 years on average), 149 (56%) were female and 117 (44%) male. We found 210 (78.9%) positive, 50 (18.8%) negative and six (2.3%) undetermined samples. Dyspeptic complaints were found in 226 cases (85.2%). There was no statistical association between dyspepsia and positive serology for H. pylori. We concluded that the seroprevalence in all age categories is similar to results found in other studies conducted in developing countries, including those from Brazil. On the other hand, the seroprevalence found in Monte Negro was higher than that reported in developed countries. As expected, there was a progressive increase in the positivity for H. pylori in older age groups.
Resumo:
This study was aimed to evaluate and compare the pathogenicity of rabies virus isolated from bats and dogs, and to verify the efficacy of a commercial rabies vaccine against these isolates. For evaluation of pathogenicity, mice were inoculated by the intramuscular route (IM) with 500MICLD50/0.03mL of the viruses. The cross-protection test was performed by vaccinating groups of mice by the subcutaneous route and challenged through the intracerebral (IC) route. Isolates were fully pathogenic when inoculated by the IC route. When inoculated intramuscularly, the pathogenicity observed showed different death rates: 60.0% for the Desmodus rotundus isolate; 50.0% for dog and Nyctinomops laticaudatus isolates; 40.0% for Artibeus lituratus isolate; 9.5% Molossus molossus isolate; and 5.2% for the Eptesicus furinalis isolate. Mice receiving two doses of the vaccine and challenged by the IC route with the isolates were fully protected. Mice receiving only one dose of vaccine were partially protected against the dog isolate. The isolates from bats were pathogenic by the IC route in mice. However, when inoculated through the intramuscular route, the same isolates were found with different degrees of pathogenicity. The results of this work suggest that a commercial vaccine protects mice from infection with bat rabies virus isolates, in addition to a canine rabies virus isolate.
Resumo:
Introdução: O controlo postural do tronco é um fator preditivo de autonomia, sendo fundamental a existência de instrumentos válidos e fiáveis a fim da sua avaliação na população portuguesa. Objetivo: Traduzir e adaptar o Trunk Control Test (TCT) para a população portuguesa em indivíduos após AVE e avaliar as suas propriedades psicométricas. Métodos: O TCT foi sujeito aos processos de tradução e retroversão para a população portuguesa por dois tradutores bilingues e realizadas duas reuniões com painel de peritos na área. Avaliou-se a validade, a fiabilidade, a sensibilidade, a especificidade e o poder de resposta em 19 indivíduos com AVE. Para avaliar a validade de critério os indivíduos foram adicionalmente submetidos à Escala de Equilíbrio de Berg (EEB), à Avaliação Motora de Rivermead (AMR) e à Escala de Comprometimento do Tronco (ECT). A fiabilidade inter-observadores foi garantida por uma segunda amostra de 25 fisioterapeutas, através da avaliação do desempenho de um participante no TCT. Os dados foram analisados no programa SPSS 22.0. Resultados: O TCT apresentou baixa consistência interna ( =0,523) e fiabilidade inter-observadores substancial (k=0,662). Obteve-se forte correlação do TCT com a ECT (r=0,885) e AMR (r=0,864), e correlação moderada com a EEB (r=0,700). A validade de construção aponta para uma moderada correlação entre itens (KMO=0,755; Bartlett=0,001). Não foi possível obter os valores de sensibilidade, especificidade e poder de resposta do TCT. Conclusão: O estudo demonstrou que o TCT é um instrumento válido e fiável na avaliação da população portuguesa após AVE.
Resumo:
This work compared the time at which negative seroconversion was detected by conventional serology (CS) and by the ELISA-F29 test on a cohort of chronic chagasic patients treated with nifurtimox or benznidazole. A retrospective study was performed using preserved serum from 66 asymptomatic chagasic adults under clinical supervision, and bi-annual serological examinations over a mean follow-up of 23 years. Twenty nine patients received trypanocide treatment and 37 remained untreated. The ELISA-F29 test used a recombinant antigen which was obtained by expressing the Trypanosoma cruzi flagellar calcium-binding protein gene in Escherichia coli. Among the untreated patients, 36 maintained CS titers. One patient showed a doubtful serology in some check-ups. ELISA-F29 showed constant reactivity in 35 out of 37 patients and was negative for the patient with fluctuating CS. The treated patients were divided into three groups according to the CS titers: in 13 they became negative; in 12 they decreased and in four they remained unchanged. ELISA-F29 was negative for the first two groups. The time at which negativization was detected was significantly lower for the ELISA-F29 test than for CS, 14.5 ± 5.7 and 22 ± 4.9 years respectively. Negative seroconversion was observed in treated patients only. The results obtained confirm that the ELISA-F29 test is useful as an early indicator of negative seroconversion in treated chronic patients.
Resumo:
Esta dissertação tem como principal objetivo a criação de uma interface humana, baseada na eletromiografia dos músculos orbicular do olho e frontalis. O algoritmo de programação do microcontrolador ATmega2560 deteta o piscar de olhos voluntário, conta o número de vezes que este acontece e verifica se preenche os requisitos necessários à execução de um comando. Para este efeito foram utilizados elétrodos para a captação do sinal eletromiográfico. O sinal analógico é condicionado pela Shield ECG/EMG da Olimex sendo enviado para o arduíno ATmega2560. Este microcontrolador administra todos os atuadores, dos quais o mais importante é um painel de comandos (quatro comandos diferentes), no qual existe um ponteiro motorizado que indica qual a ação a realizar. O código de execução é extremamente simples: se o utilizador piscar os olhos três vezes, o ponteiro movimenta-se para a secção do painel imediatamente à direita; e se o utilizador piscar os olhos quatro vezes, o ponteiro movimenta-se para a secção do painel imediatamente à esquerda. Os testes realizados com este dispositivo indicam que os utilizadores demoram menos de 10 minutos a aprender a utilizar e executar todos os comandos do painel. Apenas num dos testes realizados o dispositivo não funcionou. Dos utilizadores que realizaram o teste: vários usam óculos; um idoso com graves problemas auditivos, cegueira parcial e dificuldades locomotoras; nenhum foi incapaz de piscar, pelo menos, um dos olhos voluntariamente; e a maioria referiu que, com alguma concentração e principalmente se ouvirem o bip sonoro, a aprendizagem de utilização torna-se muito fácil. Apesar dos limites impostos à concretização de um projeto deste tipo (dos quais se evidenciam as dificuldades em conseguir voluntários com paralisia medular, bem como os limites orçamentais), pode-se afirmar que este dispositivo é eficaz e seria uma mais valia quando implementado num cenário de paralisia medular (total ou parcial). A melhoria de qualidade de vida de um utilizador com estes problemas físicos, ou outros que lhe comprometam a locomoção é garantida. O cenário em que vivem é tremendamente limitado sendo urgente criar soluções para tornar estas vidas mais cómodas. Com os devidos aplicativos, o utilizador poderia abrir portas ou janelas, acender ou apagar luzes, pedir ajuda, ajustar a posição da cama, controlar cadeiras de rodas, entre outros. É neste sentido que surge a minha motivação de criar algo que ajude estas pessoas.
Resumo:
Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics
Resumo:
Na sociedade atual, a preocupação com o ambiente, por um lado, e com o conforto e a segurança, por outro, faz com que a sustentabilidade energética se assuma como uma forma de intervenção adequada às exigências de qualidade de vida e à eficiência no âmbito da economia. Nesta conformidade, é incontornável a mais-valia do Smart Panel, um quadro elétrico inteligente criado com vista à consecução daqueles desideratos, o que motivou o tema do presente trabalho. Assim, pretende-se demonstrar as potencialidades do Smart Panel, um novo conceito de quadro elétrico que visa a otimização da sua funcionalidade na gestão dinâmica e pragmática das instalações elétricas, nomeadamente no que respeita ao controlo, monitorização e atuação sobre os dispositivos, quer in loco quer, sobretudo, à distância. Para a consecução deste objetivo, concorrem outros que o potenciam, designadamente a compreensão do funcionamento do quadro elétrico (QE) tradicional, a comparação deste com o Smart Panel e a demonstração das vantagens da utilização desta nova tecnologia. A grande finalidade do trabalho desenvolvido é, por um lado, colocar a formação académica ao serviço de um bom desempenho profissional futuro, por outro ir ao encontro da tendência tecnológica inerente às necessidades que o homem, hoje, tem de controlar. Deste modo, num primeiro momento, é feita uma abordagem geral ao quadro eléctrico tradicional a fim de ser compreendido o seu funcionamento, aplicações e potencialidades. Para tanto, a explanação inclui a apresentação de conceitos teóricos subjacentes à conceção, produção e montagem do QE. São explicitados os diversos componentes que o integram e funções que desempenham, bem como as interações que estabelecem entre si e os normativos a que devem obedecer, para conformidade. Houve a preocupação de incluir imagens coadjuvantes das explicações, descrições e procedimentos técnicos. No terceiro capítulo é abordada a tecnologia Smart Panel, introduzindo o conceito e objetivos que lhe subjazem. Explicita-se o modo de funcionamento deste sistema que agrupa proteção, supervisão, controlo, armazenamento e manutenção preventiva, e demonstra-se de que forma a capacidade de leitura de dados, de comunicação e de comando do quadro elétrico à distância se afigura uma revolução tecnológica facilitadora do cumprimento das necessidades de segurança, conforto e economia da vida moderna. Os capítulos quarto, quinto e sexto versam uma componente prática do trabalho. No capítulo quarto é explanado um suporte formativo e posterior demonstração do kit de ensaio, que servirá de apoio à apresentação da tecnologia Smart Panel aos clientes. Além deste suporte de formação, no quinto capítulo é elaborada uma lista de procedimentos de verificação a serem executados aos componentes de comunicação que integram o Smart Panel, para fornecimento ao quadrista. Por fim, no sexto capítulo incluem-se dois casos de estudo: o estudo A centra-se na aplicação da tecnologia Smart Panel ao projeto de um QE tradicional, que implica fazer o levantamento de toda a aparelhagem existente e, de seguida, proceder à transposição para a tecnologia Smart Panel por forma a cumprir os requisitos estabelecidos pelo cliente. O estudo de caso B consiste na elaboração de um projeto de um quadro eléctrico com a tecnologia Smart Panel em função de determinados requisitos e necessidades do cliente, por forma a garantir as funções desejadas.
Resumo:
The objective of this study is to report on the colonization of palm trees by Rhodnius neglectus, its invasion in an urban area, in Araçatuba - São Paulo, and the control and surveillance measures that have been put in place. Domiciliary triatomine searches occurred in apartments upon the inhabitants' notification. The collected insects were identified and examined for natural infection and food sources with a precipitin test. To search the palm trees, tarps were used to cover the floor, and a “Munck” truck equipped with a tree-pruning device was utilized. Chemical control was performed with the utilization of a manual compression. In 2009, 81 specimens of Rhodnius neglectus were collected from the domiciles by the population. The precipitin test revealed a presence of human blood in 2.7% of the samples. Entomological studies were carried out in these domiciles and in those located within a radius of 200 meters. The search performed in the palm trees resulted in the capture of 882 specimens of triatomines, negative for tripanosomatids. Mechanical and chemical controls were carried out. New searches conducted in the palm trees in the same year resulted in the capture of six specimens. The mechanical and chemical controls of the palm trees, together with the population's work, proved to be effective, therefore preventing these insects' colonization of the city's domiciles.
Resumo:
A case-control study was conducted to examine the association among the Montenegro skin test (MST), age of skin lesion and therapeutic response in patients with cutaneous leishmaniasis (CL) treated at Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro, Brazil. For each treatment failure (case), two controls showing skin lesion healing following treatment, paired by sex and age, were randomly selected. All patients were treated with 5 mg Sb5+/kg/day of intramuscular meglumine antimoniate (Sb5+) for 30 successive days. Patients with CL were approximately five times more likely to fail when lesions were less than two months old at the first appointment. Patients with treatment failure showed less intense MST reactions than patients progressing to clinical cure. For each 10 mm of increase in MST response, there was a 26% reduction in the chance of treatment failure. An early treatment - defined as a treatment applied for skin lesions, which starts when they are less than two months old at the first appointment -, as well as a poor cellular immune response, reflected by lower reactivity in MST, were associated with treatment failure in cutaneous leishmaniasis.
Resumo:
Candida albicans is often isolated from clinical samples, thus its presumptive differentiation from other species of the same genus can be based on its ability to form the germ tube in human serum. Nevertheless, there are two other species that share this characteristic: C. dubliniensis and C. africana. The aim of this study was to compare four different substrates to perform the germ tube (GT) test. The Candida spp. isolates were identified using a manual system (135 C. albicans, 24 C. tropicalis and one C. dubliniensis). The germ tube test was performed with fresh, previously frozen serum and Mueller-Hinton (MH) broth and agar. GT was observed in 96% (130/136) of the isolates through the fresh serum technique, 94% (128/136) through previously frozen serum, 92% (125/136) in MH agar, and 90% (122/136) in MH broth. The sensitivity of each test was higher than 90%, with 100% specificity. Both the MH agar and broth were able to identify the true positives, and false positives were not found. However, some C. albicans isolates were not identified. MH agar and broth may be used in laboratory for the rapid presumptive identification of C. albicans, as an alternative method for germ tube test.
Resumo:
Background: Allergic rhinitis and asthma (ARA) are chronic inflammatory diseases of the airways that often coexist in children. The only tool to assess the ARA control, the Control of Allergic Rhinitis and Asthma Test (CARAT) is to be used by adults. We aimed to develop the Pediatric version of Control of Allergic Rhinitis and Asthma Test (CARATkids) and to test its comprehensibility in children with 4 to 12 years of age. Methods: The questionnaire development included a literature review of pediatric questionnaires on asthma and/or rhinitis control and two consensus meetings of a multidisciplinary group. Cognitive testing was carried out in a cross-sectional qualitative study using cognitive interviews. Results: Four questionnaires to assess asthma and none to assess rhinitis control in children were identified. The multidisciplinary group produced a questionnaire version for children with 17 questions with illustrations and dichotomous (yes/no) response format. The version for caregivers had 4-points and dichotomous scales. Twenty-nine children, 4 to 12 years old, and their caregivers were interviewed. Only children over 6 years old could adequately answer the questionnaire. A few words/expressions were not fully understood by children of 6 to 8 years old. The drawings illustrating the questions were considered helpful by children and caregivers. Caregivers considered the questionnaire complete and clear and preferred dichotomous over the 4-points scales. The proportion of agreement between children and their caregivers was 61%. The words/expressions that were difficult to understand were amended. Conclusion: CARATkids, the first questionnaire to assess a child’s asthma and rhinitis control was developed and its content validity was assured. Cognitive testing showed that CARATKids is well-understood by children 6 to 12 years old. The questionnaire’s measurement properties can now be assessed in a validation study.
Resumo:
SUMMARYDuring recent decades, antifungal susceptibility testing has become standardized and nowadays has the same role of the antibacterial susceptibility testing in microbiology laboratories. American and European standards have been developed, as well as equivalent commercial systems which are more appropriate for clinical laboratories. The detection of resistant strains by means of these systems has allowed the study and understanding of the molecular basis and the mechanisms of resistance of fungal species to antifungal agents. In addition, many studies on the correlation of in vitro results with the outcome of patients have been performed, reaching the conclusion that infections caused by resistant strains have worse outcome than those caused by susceptible fungal isolates. These studies have allowed the development of interpretative breakpoints for Candida spp. and Aspergillus spp., the most frequent agents of fungal infections in the world. In summary, antifungal susceptibility tests have become essential tools to guide the treatment of fungal diseases, to know the local and global disease epidemiology, and to identify resistance to antifungals.
Resumo:
RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.