422 resultados para stripping
Resumo:
Experimental tests have been completed for high-strength 8.8 bolts for studying their mechanical performance subjected to tensile loading. As observed from these tests, failure of structural bolts has been identified as in one of two ways: threads stripping and necking of the threaded portion of the bolt shank, which is possibly due to the degree of fit between internal and external threads. Following the experimental work, a numerical approach has been developed for demonstration of the tensile performance with proper consideration of tolerance class between bolts and nuts. The degree of fit between internal and external threads has been identified as a critical factor affecting failure mechanisms of high-strength structural bolts in tension, which is caused by the machining process. In addition, different constitutive material laws have been taken into account in the numerical simulation, demonstrating the entire failure mechanism for structural bolts with different tolerance classes in their threads. It is also observed that the bolt capacities are closely associated with their failure mechanisms.
Resumo:
The main objective of this R&D work is to simulate particle beam optics in CV-28 Cyclotron of Instituto de Engenharia Nuclear – IEN/CNEN, as a support for improvements or optimization of this particle accelerator. Besides 2D magnetostatic field computation results, the authors present an alternative method for charged particle trajectories computation in electrostatic or magnetostatic fields. This task is approached by analytical computation of trajectories, by parts, considering constant fields within each finite element. This method has some advantages over numerical integration ones: numerical miscomputation of trajectories is avoided; stability problem is also avoided, for the magnetostatic field case. Some examples are presented, including positive ion extraction from cyclotrons with strip-foil. This latter technique is an interesting alternative for upgrading positive ion cyclotrons, such as CV-28 Cyclotron. The particle trajectory computation method presented in this work is of interest not only for cyclotrons, but for accelerator and related technology, in general.
Resumo:
Introduction. Subfascial Endoscopic Perforator Surgery (SEPS) enables the direct visualization and section of perforating veins. Morbidity and duration of hospitalization are both less than with conventional open surgery (Linton’s or Felder’s techniques). Patients and methods. A total of 322 legs from 285 patients with a mean age of 56 years (range 23-90) were treated at our Department from May 1996 to January 2010. In 309 cases, an endoscope (ETM Endoskopische Technik GmbH, Berlin, Germany) was introduced through a transverse incision approximately 1.5 cm in length and 10 cm from the tibial tuberosity, as with Linton’s technique. A spacemaker balloon dissector for SEPS, involving a second incision 6 cm from the first, was used in only 13 cases. Results. The procedure used in each case was decided on the basis of preoperative evaluation. SEPS and stripping were performed in 238 limbs (73.91%), SEPS and short stripping in 7 limbs (2.17%), SEPS and crossectomy in 51 limbs (15.84%), and SEPS alone in 26 limbs (8.07%). 103 patients presented a total of 158 trophic ulcers; the healing time was between 1 and 3 months, with a healing rate of 82.91% after 1 month and 98.73% after 3 months. Conclusion. Subfascial ligature of perforating veins is superior to sclerotherapy and minimally invasive suprafascial treatment for the treatment of CVI. It is easy to execute, minimally invasive and has few complications.
Resumo:
The present study was aimed at assessing the experience of a single referral center with recurrent varicose veins of the legs (RVL) over the period 1993-2008. Among a total of 846 procedures for Leg Varices (LV), 74 procedures were for RVL (8.7%). The causes of recurrence were classified as classic: insufficient crossectomy (13); incompetent perforating veins (13); reticular phlebectasia (22); small saphenous vein insufficiency (9); accessory saphenous veins (4); and particular: post-hemodynamic treatment (5); incomplete stripping (1); Sapheno-Femoral Junction (SFJ) vascularization (5); post-thermal ablation (2). For the “classic” RVL the treatment consisted essentially of completing the previous treatment, both if the problem was linked to an insufficient earlier treatment and if it was due to a later onset. The most common cause in our series was reticular phlebectasia; when the simple sclerosing injections are not sufficient, this was treated by phlebectomy according to Mueller. The “particular” cases classified as 1, 2 and 4 were also treated by completing the traditional stripping procedure (+ crossectomy if this had not been done previously), considered to be the gold standard. In the presence of a SFJ neo-vascularization, with or without cavernoma, approximately 5 cm of femoral vein were explored, the afferent vessels ligated and, if cavernoma was present, it was removed. Although inguinal neo-angiogenesis is a possible mechanism, some doubt can be raised as to its importance as a primary factor in causing recurrent varicose veins, rather than their being due to a preexisting vein left in situ because it was ignored, regarded as insignificant, or poorly evident. In conclusion, we stress that LV is a progressive disease, so the treatment is unlikely to be confined to a single procedure. It is important to plan adequate monitoring during follow-up, and to be ready to reoperate when new problems present that, if left, could lead the patient to doubt the validity and efficacy of the original treatment.
Resumo:
Os sedimentos podem atuar tanto como acumuladores quanto como fontes de poluentes. Em função das atividades portuárias locais estarem em ritmo de crescimento pela ampliação do porto de Rio Grande (RS), estudos que mostrem a situação do local investigado são importantes a fim de prever o aporte do ferro nesse ambiente. Neste trabalho, a especiação química do ferro e a determinação da concentração do metal total e dissolvido em amostras de águas intersticiais no sedimento do Saco do Mendanha (RS) foram avaliadas, utilizando a Voltametria Adsortiva de Redissolução Catódica com o ligante 2,3-Dihidroxinaftaleno. O objetivo principal desse trabalho foi validar a metodologia analítica para realizar a especiação química do ferro em águas intersticiais, o que englobou a faixa linear de trabalho, limites de detecção e de quantificação, a exatidão e precisão. O Limite de Detecção encontrado foi de 0,11 nmol L-1 . Foram determinadas as concentrações de ferro total, dissolvido e lábil em três frações distintas: na interface água/sedimento, entre 0 e -5 cm; e entre -15 e -20 cm de profundidade na coluna sedimentar. Nas amostras analisadas, a concentração de ferro lábil encontrada foi entre 4,64 – 135,37 µmol L-1 ; a concentração do metal dissolvido foi de 6,25 – 322,70 µmol L-1 e de ferro total entre 83,36 – 390,30 µmol L-1 . A concentração do metal lábil em comparação com a fração dissolvida e total indica a presença de complexos estáveis entre o metal e a matéria orgânica natural presente na água intersticial, tornando dessa forma, o metal menos biodisponível para a biota local. Durante os meses de amostragem do sedimento, foi observada variação da concentração do metal, onde no mês de abril ocorreu o maior aporte do metal da coluna d’água para o sedimento. Essa transferência do metal para o sedimento pode estar relacionada pela forte mudança na salinidade no local de amostragem, passando de 16 no mês de fevereiro para 33 no mês de abril e para próximo de zero nos meses de agosto e novembro de 2009.
Resumo:
Objectives: In contrast to other countries, surgery still represents the common invasive treatment for varicose veins in Germany. However, radiofrequency ablation, e.g. ClosureFast, becomes more and more popular in other countries due to potential better results and reduced side effects. This treatment option may cause less follow-up costs and is a more convenient procedure for patients, which could justify an introduction in the statutory benefits catalogue. Therefore, we aim at calculating the budget impact of a general reimbursement of ClosureFast in Germany. Methods: To assess the budget impact of including ClosureFast in the German statutory benefits catalogue, we developed a multi-cohort Markov model and compared the costs of a “World with ClosureFast” with a “World without ClosureFast” over a time horizon of five years. To address the uncertainty of input parameters, we conducted three different types of sensitivity analysis (one-way, scenario, probabilistic). Results: In the Base Case scenario, the introduction of the ClosureFast system for the treatment of varicose veins saves costs of about 19.1 Mio. € over a time horizon of five years in Germany. However, the results scatter in the sensitivity analyses due to limited evidence of some key input parameters. Conclusions: Results of the budget impact analysis indicate that a general reimbursement of ClosureFast has the potential to be cost-saving in the German Statutory Health Insurance.
Resumo:
A presença de metais traço no ambiente está associada às fontes naturais e antropogênicas. O aumento das concentrações desses elementos pode resultar em um desequilíbrio do ecossistema tornando-se um risco potencial para o meio. O metal cromo tem seus efeitos relacionados com sua concentração e com o estado de oxidação em que se apresenta, já que seu estado trivalente é considerando essencial, enquanto que seu estado hexavalente é considerado extremamente tóxico. O objetivo deste trabalho é realizar a especiação química do cromo após ter sido realizada a revalidação analítica, englobando faixa linear de trabalho, limites de detecção e quantificação, exatidão e precisão. Este estudo é essencial tanto pela questão ambiental quanto sanitária, já que a especiação foi realizada em cinco pontos do Estuário da Lagoa dos Patos - dois na Zona Portuária e três no Saco da Mangueira, entre os meses de março e setembro de 2008 e também na Estação de Tratamento de Água que ocorreram entre os meses de janeiro e setembro de 2008. Foram realizadas determinações das frações de Cr (III) ativo, Cr (VI) e Cr (III) não ativo, por Voltametria de Redissolução Catódica. A Fração de Cromo Total foi determinada por Espectrometria de Absorção Atômica. Também foram realizadas in situ determinações dos seguintes parâmetros físicoquímicos: salinidade, pH, Eh, oxigênio dissolvido e temperatura; além dos nutrientes nitrogenados. As determinações não identificaram o metal no estado de oxidação mais tóxico (cromo hexavalente), também não foi identificada a fração de Cr (III) ativo. O metal foi identificado na forma de Cr (III) não-ativo, ou seja, na forma trivalente e complexada por ligantes naturais estáveis. As concentrações de cromo total estiveram sempre abaixo do limite estabelecido pelos órgãos reguladores competentes. Portanto, mesmo com as atividades industriais e portuárias existentes na região, não foram identificadas concentrações ou espécies de cromo que caracterizam um ambiente impactado.
Resumo:
451 p.
Resumo:
2-Aminothiazole covalently attached to a silica gel surface was prepared in order to obtain an adsorbent for Hg(II) ions having the following characteristics: good sorption capacity, chemical stability under conditions of use, and, especially, high selectivity. The accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2-aminothiazole (SIAMT-CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range -0.2 to + 0.6 V versus Ag/AgCl (0.02 mol L-1 KNO3; V = 20 mV s(-1)) show two peaks one at about 0.1 V and other at 0.205 V. The anodic wave peak at 0.205 V is well defined and does not change during the cycles and it was therefore further investigated for analytical purposes using differential pulse anodic stripping voltammetry in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. The precision for six determinations (n = 6) of 0.02 and 0.20 mg L-1 Hg(II) was 4.1 and 3.5% (relative standard deviation), respectively. The detection limit was estimated as 0.10 mu g L-1 mercury(II) by means of 3:1 current-to-noise ratio in connection with the optimization of the various parameters involved and using the highest-possible analyser sensitivity. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Partial funding for open access provided by the UMD Libraries' Open Access Publishing Fund.
Resumo:
Nacomposites of polymers and lamellar clayminerals, has generated high scientific and technological interest, for having mechanical properties and gas barriers differentiated of polymers and conventional composites. In this work, it was developed nanocomposites by single screw extruder and injection, utilizing commercial raw material, with the goal to investigate the quality of new developed materials. It was evaluated the influence of the content and the kind of clay in the structure and in the nanocomposites properties. It was used regular and elastomeric poly (methyl methacrylate) (Acrigel LEP 100 and Acrigel ECP800) and six montmorillonites (Cloisite 10A, 11B, 15A, 20A, 25A e 30B) at the concentration of 1% e 3% in weight. The nanocomposites were characterized by X-ray diffraction (XRD), thermal gravimetric analysis (TGA), transmission electron microscopy (TEM), colorimetric, optical transparency, flexural and tensile tests, Rockwell hardness and esclerometry. It was founded that is possible to obtain intercalated and exfoliated nanocomposites PMMA/MMT, and the top results was obtained in the materials with 1%in clay weight organophilizated with 2M2HT (Cloisite 15A and 20A) presented intercalate and hybrid morphology (exfoliated and flocullated). The ones that was produced with organophilizated clay with 2MHTL8 (Cloisite 30B) had excellent visual quality, but the majority presented hybrid morphology. In the materials processed with organophilizated clay with MT2ETOH (Cloisite 30B), there were color change and loss of transparency. It occurs improvement in a few mechanical properties, mainly in the materials produced with PMMA elastomeric (Acrigel ECP800), being more significant, the increase in the resistance to stripping in those nanocomposites
Resumo:
In order to deepen the knowledge about the origin of the CO preoxidation process and the intrinsic catalytic activity of Pt superficial steps toward CO oxidation, a series of CO stripping experiments were performed on stepped Pt electrodes in acidic medium. For the occurrence of CO preoxidation, it was found that it arises (reproducibly) whenever four interconnected conditions are simultaneously fulfilled: (1) CO adsorption at potentials lower than about 0.2 V; (2) on surfaces saturated with COads; (3) in the presence of traces of CO in solution; (4) in the presence of surface steps. If any of these four conditions is not satisfied, the CO preoxidation pathway does not appear, even though the steps on the electrode surface are completely covered by CO. By controlling the removal of the CO adlayer (voltammetrically), we show that once the CO adlayer has been partially oxidized, the (111) terrace sites of stepped surfaces are released earlier than the (110) step sites. Moreover, if (110) steps are selectively decorated with CO, its oxidation occurs only at potentials ∼150 mV higher than the CO preoxidation peak. Our results systematically demonstrate that step sites are less active to oxidize CO than those ones responsible for the CO preoxidation process. Once the sites responsible for the CO preoxidation are made free, there is no apparent motion of the remaining adsorbed CO layer, suggesting that the activation of the surface controls the whole process, rather than the diffusion of COads toward hypothetically “most active sites”. Voltammetric and chronoamperometric experiments performed on partially covered CO adlayers suggest that adsorbed CO behave as a motionless species during its oxidation, in which the CO adlayer is removed piece by piece. By means of in situ FTIR experiments, the stretching frequency of CO selectively adsorbed on (110) step sites was examined. Band frequency results confirm that those molecules adsorbed on steps are fully coupled with the adsorbed CO on (111) terraces when the surface reaches full coverage.
Resumo:
In the months of January 2001 and 2002, female cachara Pseudoplatystoma fasciatum were selected during their first and second gonadal maturation (2 years and 7 months old and 3 years and 7 months old, respectively) with an of oocyte diameter of 937.5 mum (82.5% with central nuclei and 17.5% with peripheral nuclei). Nine females in first maturation received two doses of carp pituitary extract (CPE), 0.5 mg/kg and 5.0 mg/kg; seven received two doses of human chorionic gonadotropin (hCG), 5 and 10 IU/g; five received doses of 0.5 CPE mg/kg and 5 hCG IU/g (CPE+hCG); and four received 0.9% saline (saline). Nine females from CPE and seven from hCG presented oocytes with the same diameter at the moment of oocyte release (100% with germinal vesicle breakdown and fertilization rate of 53.44 +/- 18.3 and 54.81 +/- 11.8%; larvae number of 165,330 +/- 94.1 and 158,570 +/- 20.6, respectively). The five females from CPE+hCG did not respond to the hormonal treatment. The four females from the saline group did not ovulate. In January 2002, 6 of 15 selected females that were going through the second reproductive cycle received CPE (five received hCG and four received saline), showing oocyte diameters similar to the ones in the first maturation. At stripping, CPE females had an oocyte diameter of 1062.5 mum (the hCG females had oocyte diameters ranging from 937.5 to 1125.0 mum; fertilization rates of 56.08 +/- 30.9 and 81.90 +/- 17.3%; 364,547 +/- 244 and 633,129 +/- 190, larvae, respectively). The fertilization rates and larvae number were higher in the second gonad maturation, both for CPE and hCG. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
We quantify the evolution of the stellar mass functions (SMFs) of star-forming and quiescent galaxies as a function of morphology from z ∼ 3 to the present. Our sample consists of ∼50 000 galaxies in the CANDELS fields (∼880 arcmin^2), which we divide into four main morphological types, i.e. pure bulge-dominated systems, pure spiral disc-dominated, intermediate two-component bulge+disc systems and irregular disturbed galaxies. At z ∼ 2, 80 per cent of the stellar mass density of star-forming galaxies is in irregular systems. However, by z ∼ 0.5, irregular objects only dominate at stellar masses below 10^9 M_⊙. A majority of the star-forming irregulars present at z ∼ 2 undergo a gradual transformation from disturbed to normal spiral disc morphologies by z ∼ 1 without significant interruption to their star formation. Rejuvenation after a quenching event does not seem to be common except perhaps for the most massive objects, because the fraction of bulge-dominated star-forming galaxies with M^*/M_⊙ > 10^10.7 reaches 40 per cent at z < 1. Quenching implies the presence of a bulge: the abundance of massive red discs is negligible at all redshifts over 2 dex in stellar mass. However, the dominant quenching mechanism evolves. At z > 2, the SMF of quiescent galaxies above M^* is dominated by compact spheroids. Quenching at this early epoch destroys the disc and produces a compact remnant unless the star-forming progenitors at even higher redshifts are significantly more dense. At 1 < z < 2, the majority of newly quenched galaxies are discs with a significant central bulge. This suggests that mass quenching at this epoch starts from the inner parts and preserves the disc. At z < 1, the high-mass end of the passive SMF is globally in place and the evolution mostly happens at stellar masses below 10^10 M_⊙. These low-mass galaxies are compact, bulge-dominated systems, which were environmentally quenched: destruction of the disc through ram-pressure stripping is the likely process.
Resumo:
L'obiettivo del lavoro di tesi ha riguardato il confronto tra due soluzioni impiantistiche per la deodorazione di olio di semi di girasole e mais in uno specifico ambito aziendale (Tampieri S.P.A. Faenza). La nuova linea di deodorazione è stato progettata per abbattere il residuo di pesticida e di molecole tossiche quali 2/3 – MCPD e Ges, migliorando anche alcuni parametri di qualità degli oli di semi raffinati. Le prestazioni dell'impianto sono state valutate confrontando le differenze tra alcuni parametri di prodotto, con particolare riguardo ai glicerol esteri (GEs). Il nuovo deodoratore: - ha risolto il problema dei pesticidi (grazie al vuoto più spinto) e migliorato molti parametri di qualità degli oli di semi; - non ha abbassato la carica dei 2/3 MCPD, poiché l’aumento di questi ultimi è legato al livello di degradazione della materia prima da una parte, dall’acidità delle terre decoloranti dall’altra; – ha abbassato la carica dei GE, grazie al minor tempo di stazionamento dell’olio in colonna ed alla maggiore efficienza, dovuta in gran parte alla camera di post stripping. Si è passati da 880 ppb a 290 ppb per il mais (che comunque presenta un valore più alto perché maggiori sono i suoi valori iniziali di DAG) e da 120 ppb a <100 per il girasole.