918 resultados para side-pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A side-fed bifilar helix antenna can be integrated with a quadrifilar helix antenna in a piggy back configuration in order to achieve a dual-mode radiating structure. The overall length of the structure is 0.44 lambda at the resonant frequency (1.54 GHz) of the space mode antenna and 0.39 lambda at the resonant frequency (1.34 GHz) of the terrestrial mode antenna. The computed results are validated by experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A side-fed bifilar is shown to generate a similar radiation pattern as a dipole antenna, but the structure has a significantly reduced axial length. Simulated and measured results show that the helix turn angle can be used to control the ratio of the orthogonal linear field components and the input impedance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper summarises die main results obtained during the two experimental campaigns on TCE X-ray lasers that we have carried out since the last Kyoto X-ray laser Conference in 1998. A two-color (2 omega /1 omega) pumping configuration was tested and led to the observation of a strong lasing line at 16 nm, identified to a 4f-4d transition in Ni-like Ag. A strong x 300-400 enhancement of the 13.9 nm Ni-like 4d-4p lasing emission was obtained when a traveling wave short pulse pumping was applied. Finally the temporal history of the 13.9 nm laser pulse was measured with a high-resolution Streak camera, A very short 2 ps X-ray laser pulse was directly demonstrated for the first time.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a coordinated control of the rotor and grid side converters (RSC & GSC) of doubly-fed induction generator (DFIG) based wind generation systems under unbalanced voltage conditions. System behaviors and operations of the RSC and GSC under unbalanced voltage are illustrated. To provide enhanced operation, the RSC is controlled to eliminate the torque oscillations at double supply frequency under unbalanced stator supply. The oscillation of the stator output active power is then cancelled by the active power output from the GSC, to ensure constant active power output from the overall DFIG generation system. To provide the required positive and negative sequence currents control for the RSC and GSC, a current control strategy containing a main controller and an auxiliary controller is analyzed. The main controller is implemented in the positive (dq)+ frame without involving positive/negative sequence decomposition whereas the auxiliary controller is implemented in the negative sequence (dq)? frame with negative sequence current extracted. Simulation results using EMTDC/PSCAD are presented for a 2MW DFIG wind generation system to validate the proposed control scheme and to show the enhanced system operation during unbalanced voltage supply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The travel experience filled with personal trauma; the pilgrimage through a war-torn place; the journey with those suffering: these represent the darker sides of travel. What is their allure and how are they represented? This volume takes an ethnographic and interdisciplinary approach to explore the writings and texts of dark journeys and travels. In traveling over the dead, amongst the dying, and alongside the suffering, the authors give us a tour of humanity’s violence and misery. And yet, from this dark side, there comes great beauty and poignancy in the characterization of plight; creativity in the comic, graphic, and graffiti sketches and comments on life; and the sense of profound and spiritual journeys being undertaken, recorded, and memorialized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The relationship between use of proton pump inhibitors (PPIs) and histamine-2-receptor antagonists (H2RAs) and pancreatic cancer risk has yet to be examined. Data from a range of studies suggest biologically plausible mechanisms, whereby these drugs (or the conditions for which they are prescribed) may affect pancreatic cancer risk. The objective of this study was to investigate the relationship between use of PPIs/H2RAs and pancreatic cancer risk.

Methods: A nested case – control study was conducted within the UK general practice research database (GPRD). Cases had a diagnosis of exocrine pancreatic cancer and controls were matched to cases on general practice site, sex and year of birth. Exposure to PPIs and to H2RAs since entry into GPRD until 2 years before the diagnosis date (corresponding date in controls) and in the 5 years before the diagnosis date were separately assessed. Conditional logistic regression analyses were used to generate odds ratios (ORs) and 95% confidence intervals (CIs) associated with PPI or H2RA use compared with nonuse.

Results: Ever use of PPIs since entry into the GPRD (excluding the 2 years prior to diagnosis) was not associated with risk of pancreatic cancer; OR (95% CI) 1.02 (0.85 – 1.22). Neither the dose nor the duration of PPI or H2RA use was associated with pancreatic cancer risk. No consistent patterns of association were seen when cumulative exposure (dose and duration) to these drugs was examined separately or together.

Conclusion: PPI/H2RA use, in a UK population, was not associated with pancreatic cancer risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report what is to our knowledge the first demonstration of a transient x-ray laser pumped by a 350-fs pulse in a traveling-wave irradiation geometry. For a 500-fs pump pulse the traveling-wave irradiation was found to have a strong effect on enhancing the Ni-like silver 4d-4p lasing emission at 13.9 nm. The signal enhancement was significantly less when the pulse duration was lengthened to 1.7 ps. The experimental observations are well reproduced by a simple model when the duration of gain is taken of the order of 15-20 ps. For the 500-fs pulse a gain coefficient of 14.5 cm(-1) was measured for plasma lengths up to 7 mm. Refraction of the amplified photons is believed to be the main cause of the limitation of the effective amplification length. (C) 2000 Optical Society of America.