970 resultados para side-effect


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the effect of mismatching abutments on implants with a wider platform on the peri-implant hard tissue remodeling and the soft tissue dimensions.Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, one tapered implant was installed on each side of the mandibular molar region with the implant shoulder placed at the level of the buccal alveolar bony crest. on the right side of the mandible, an abutment of reduced diameter in relation to the platform of the implant was used, creating a mismatch of 0.85 mm (test), whereas an abutment of the same diameter of the implant platform was affixed in the left side of the mandible (control). The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment.Results: All implants were completely osseo-integrated. Bone levels were superior at the test than at the control sites. However, statistically significant differences were found only at the buccal and proximal aspects. The soft tissue vertical dimension was higher at the control compared with the test sites. However, statistically significant differences were demonstrated only at the buccal aspects.Conclusions: A mismatch of 0.85 mm between the implant and the abutment yielded more coronal levels of bone-to-implant contact and a reduced height of the peri-implant soft tissue (biologic width), especially at the buccal aspect, if the implant shoulder was placed flush with the level of the buccal alveolar bony crest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work considers a problem of interest in several technological applications such as the thermal control of electronic equipment. It is also important to study the heat transfer performance of these components under off-normal conditions, such as during failure of cooling fans. The effect of natural convection on the flow and heat transfer in a cavity with two flush mounted heat sources on the left vertical wall, simulating electronic components, is studied numerically and experimentally. The influence of the power distribution, spacing between the heat sources and cavity aspect ratio have been investigated. An analysis of the average Nusselt number of the two heat sources was performed to investigate the behavior of the heat transfer coefficients. The results obtained numerically and experimentally, after an error analysis, showed a good agreement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this investigation was to evaluate the cleaning effect of CO 2 on surface topography and composition of failed dental implant surfaces. Ten failed dental implants were retrieved from nine patients (mean age, 46.33 ± 5.81 years) as a result of early or late failure. The implants were divided into two parts: one side of the implant was irradiated with a CO 2 laser (test side), while the other side did not receive irradiation (control side). The CO 2 laser was operated at 1.2 W in a continuous wave for 40 seconds (40 J energy). The handpiece of the CO 2 laser was kept at a distance of 30 mm from the implant surface, resulting in a spot area of 0.031415 cm 2 (38.20 W/cm 2; 1559 J/cm 2) in scanning mode (cervical-apical). One unused dental implant was used as a negative control for both groups. All implant surfaces were examined by scanning electron mi croscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) for element analysis. SEM showed that the surface of the test sides consisted of different degrees of organic residues, appearing mainly as dark stains similar to those observed on the control sides. None of the test surfaces presented alterations such as crater-like alterations, lava-like layers, or melting compared with the nonirradiated surfaces. Foreign elements such as carbon, oxygen, sodium, calcium, and aluminum were detected on both sides. These results suggest that CO 2 laser irradiation does not modify the implant surface, although the cleaning effect was not satisfactory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Patients with fixed orthodontic appliances often experience an absolute increase in the number of Streptococci mutans colony-forming units (cfu). The aim of this investigation was to study the development of biofilm and S. mutans cfu in connection with stainless steel ligatures and elastomeric rings in orthodontic patients treated with and without 0.4% stannous fluoride gel (SFG). Material: Forty-seven patients were divided into 2 groups: those treated with 0.4% SFG for 4 minutes (experimental) and those without 0.4% SFG (control). In each patient, elastomeric rings were used for ligation on 1 side of the dental arch midline, and stainless steel ligatures were used on the opposite side. Saliva samples were collected before and after appliance placement. At 15 and 30 days after appliance placement, biofilm samples from the stainless steel ligatures and the elastomeric rings were collected and subjected to microbiologic procedures and scanning electron microscopy (SEM) analysis. Results: The numbers of S. mutans cfu in the saliva and biofilm were not statistically different between the teeth fitted with elastomeric rings and stainless steel ligatures, or between the experimental and control groups. SEM analysis showed biofilm formation on both ligature ties. Conclusions: Topical application of 0.4% SFG in orthodontic patients with elastomeric rings or stainless steel ligatures does not cause a significant decrease in S. mutans cfu in the saliva and biofilm. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Brazil zinnias have good prospect for the flowering potted plant market, once consumers demand for new forms of products is stimulated by novelty. 'Persian Carpet' is a highly ornamental plant, with fast growth, minimal labor requirements and low cost seeds. The present study evaluated the effect of growth regulators on development and quality of 'Persian Carpet' grown as a potted plant. Growth regulators are commonly used to control growth and produce short and compact plants. Paclobutrazol (0.5, 0.75 and 1.0 mg a.i./pot) and chlormequat (1.0, 2.0 and 3.0 g. L-1) were applied as a single drench, and daminozide (2.5, 3.75 and 5.0 g. L-1) as a single foliar spray to runoff. Regulators were applied at apical flower bud stage. Daminozide (5.0 g. L-1), paclobutrazol (0.5, 0.75 and 1.0 mg a.i./pot) and chlormequat (1.0 g. L-1) significantly reduced plant height and side branches length compared to the control. Plant height showed a negative linear response to the increasing concentration of daminozide or paclobutrazol. Paclobutrazol (1.0 mg a.i./pot) and chlormequat (1.0 g. L-1) increased foliage and flowers harvest index. Plant spread diameter and canopy shape were improved with paclobutrazol (0.75 mg a.i./pot). Chlormequat (2.0 and 3.0 g. L-1) caused phytotoxicity symptoms, turning plants unsuitable for commercialization. Studied regulators concentrations did not affect flower diameter and production cycle. Although regulators controlled height and side branches growth significantly, plants were not short and compact enough to attend market quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes the application of computational intelligence techniques to assist complex problems concerning lightning in transformers. In order to estimate the currents related to lightning in a transformer, a neural tool is presented. ATP has generated the training vectors. The input variables used in Artificial Neural Networks (ANN) were the wave front time, the wave tail time, the voltage variation rate and the output variable is the maximum current in the secondary of the transformer. These parameters can define the behavior and severity of lightning. Based on these concepts and from the results obtained, it can be verified that the overvoltages at the secondary of transformer are also affected by the discharge waveform in a similar way to the primary side. By using the tool developed, the high voltage process in the distribution transformers can be mapped and estimated with more precision aiding the transformer project process, minimizing empirics and evaluation errors, and contributing to minimize the failure rate of transformers. © 2009 The Berkeley Electronic Press. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: Compare the effect of three post designs on the fracture resistance and failure modes of composite core-fiber post-crownless tooth sets. Materials and Methods: Ninety bovine incisors were selected and divided into nine groups of 10 specimens. The teeth were assigned to three groups based on the post design: Cylindrical, tapered, and double-tapered. Each group was subdivided into three subgroups in accordance with the diameter of the post: Small (No.1), medium (No.2), and large (No.3). The Panavia F system was used for post cementation. The specimens were mounted in acrylic resin blocks with a layer of silicone rubber covering the roots. A universal testing machine compressively loaded the specimens from the palatal side at a crosshead speed of 1 mm/min and at an angle of 135I to the long axis of the teeth, until failure occurred. The failure mode was determined by a stereomicroscope inspection of all the specimens. Data were analyzed by one-way ANOVA and the Tukey test (P < 0.05). Results: The fracture resistance was affected by the type of post (P < 0.0001). A narrower diameter for all of the post systems allowed for higher resistance. The main failure mode in the large cylindrical group was catastrophic fractures, while the main failures in the other eight groups were favorable. Conclusion: Narrower diameter posts showed higher fracture resistance. The dominant failure pattern was repairable fracture, except for those with large cylindrical groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking reconstruction plate in the fixation of atrophic mandible fractures. Polyurethane mandibles with a simulated linear fracture at the midline were used as substratum. Results show that resistance of the fixation is poor when one and two screws are used on each side of the fracture. Three screws on each side of the fracture significantly increases the resistance to displacement. However, no additional strength is added to the construct when more than three screws per side are used. © 2013 International Association of Oral and Maxillofacial Surgeons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-level laser therapy (LLLT) has been used for the treatment of dentinal hypersensitivity. However, the specific LLL dose and the response mechanisms of these cells to transdentinal irradiation have not yet been demonstrated. Therefore, this study evaluated the transdentinal effects of different LLL doses on stressed odontoblast-like pulp cells MDPC-23 seeded onto the pulpal side of dentin discs obtained from human third molars. The discs were placed in devices simulating in vitro pulp chambers and the whole set was placed in 24-well plates containing plain culture medium (DMEM). After 24 h incubation, the culture medium was replaced by fresh DMEM supplemented with either 5% (simulating a nutritional stress condition) or 10% fetal bovine serum (FBS). The cells were irradiated with doses of 15 and 25 J cm-2 every 24 h, totaling three applications over three consecutive days. The cells in the control groups were removed from the incubator for the same times as used in their respective experimental groups for irradiation, though without activating the laser source (sham irradiation). After 72 h of the last active or sham irradiation, the cells were evaluated with respect to succinic dehydrogenase (SDH) enzyme production (MTT assay), total protein (TP) expression, alkaline phosphatase (ALP) synthesis, reverse transcriptase polymerase chain reaction (RT-PCR) for collagen type 1 (Col-I) and ALP, and morphology (SEM). For both tests, significantly higher values were obtained for the 25 J cm-2 dose. Regarding SDH production, supplementation of the culture medium with 5% FBS provided better results. For TP and ALP expression, the 25 J cm-2 presented higher values, especially for the 5% FBS concentration (Mann-Whitney p < 0.05). Under the tested conditions, near infrared laser irradiation at 25 J cm -2 caused transdentinal biostimulation of odontoblast-like MDPC-23 cells. © 2013 Astro Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This longitudinal clinic study evaluated the effect of a glass ionomer sealant (GIS) and a fluoride varnish (FV) in the prevention of dental decay on newly erupted permanent molars of children with and without caries experience. Materials and methods: Eighty children, aged 6-8 years, with all four newly erupted first permanent molars, were divided into two groups. Group 1 consisted of 53 children without caries experience and group 2 consisted of 27 children with dental caries experience. Permanent molars of the right side were sealed with GIS and the fluoride varnish was applied on the other two permanent first molars. Evaluation of GIS retention and the effectiveness of both materials in the prevention of dental caries were performed after 6, 12 and 18 months. Results: After 18 months, of the 299 teeth, 271 (91%) showed no caries lesions and 28 presented caries lesions (9%). Teeth sealed with GIS had more carious lesions (15) than teeth with fluoride varnish (13). Most of the teeth (70%) that presented carious lesions were in group 2. Of the 138 sealed teeth, only one showed GIS to be totally present, 95 were partially present and 42 teeth were absent. Conclusion: The caries-preventive effect was very similar between both treatments. The presence of dental caries prevailed in the children with caries experience. © 2013 Informa Healthcare.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the antimicrobial effect of antimicrobial photodynamic therapy (aPDT) in alveolar treatment of areas with induced periodontitis. Thirty male Wistar rats were subjected to ligature-induced periodontal disease (PD) in the first left inferior molars, while the right side molars did not receive ligatures. After 7 days of PD evolution, ligatures were removed from the left side, and the first left and right mandibular molars were extracted. Afterwards, animals were divided into groups according to the following treatments: control (C)-no treatment; mechanical debridement (MD)-mechanical debridement and irrigation with saline solution; and aPDT-mechanical debridement, irrigation with toluidine blue O (TBO), and 1 min of laser irradiation (GaAlAs, 660 nm, 30 mW, 32 J/cm2, 60 s). Ligatures were removed and samples of the alveolar content after extraction and after each treatment were collected for microbial processing by real-time polymerase chain reaction with specific primers for Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and Treponema denticola. Data were submitted to statistical analysis by multiple comparison tests (McNemar test; p < 0.05). T. denticola was not found in the collected samples. A. actinomycetemcomitans and P. gingivalis were found in ligature samples. Tooth socket samples without periodontitis induction presented lesser microbial charge than samples with induced periodontitis (p < 0.05). aPDT significantly reduced A. actinomycetemcomitans levels on the left side (p < 0.05). It was concluded that aPDT was an effective antimicrobial treatment for tooth sockets in areas affected by induced periodontitis. © 2013 Springer-Verlag London.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Individuals with facial paralysis of 6 months or more without evidence of clinical or electromyographic improvement have been successfully reanimated utilizing an orthodromic temporalis transfer in conjunction with end-to-side cross-face nerve grafts. The temporalis muscle insertion is released from the coronoid process of the mandible and sutured to a fascia lata graft that is secured distally to the commissure and paralyzed hemilip. The orthodromic transfer of the temporalis muscle overcomes the concave temporal deformity and zygomatic fullness produced by the turning down of the central third of the muscle (Gillies procedure) while yielding stronger muscle contraction and a more symmetric smile. The muscle flap is combined with cross-face sural nerve grafts utilizing end-to-side neurorrhaphies to import myelinated motor fibers to the paralyzed muscles of facial expression in the midface and perioral region. Cross-face nerve grafting provides the potential for true spontaneous facial motion. We feel that the synergy created by the combination of techniques can perhaps produce a more symmetrical and synchronized smile than either procedure in isolation.Nineteen patients underwent an orthodromic temporalis muscle flap in conjunction with cross-face (buccal-buccal with end-to-side neurorrhaphy) nerve grafts. To evaluate the symmetry of the smile, we measured the length of the two hemilips (normal and affected) using the CorelDRAW X3 software. Measurements were obtained in the pre- and postoperative period and compared for symmetry.There was significant improvement in smile symmetry in 89.5 % of patients.Orthodromic temporalis muscle transfer in conjunction with cross face nerve grafts creates a synergistic effect frequently producing an aesthetic, symmetric smile.This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.spinger.com/00266.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prophylactic effect of ondansetron on subarachnoid morphine-induced pruritus is controversial, while evidence suggests that droperidol prevents pruritus. The aim of this study is to compare the effects of droperidol and ondansetron on subarachnoid morphine-induced pruritus. 180 ASA I or II patients scheduled to undergo cesarean sections under subarachnoid anesthesia combined with morphine 0.2mg were randomized to receive, after the child's birth, metoclopramide 10mg (Group I - control), droperidol 2.5mg (Group II) or ondansetron 8mg (Group III). Postoperatively, the patients were assessed for pruritus (absent, mild, moderate or severe) or other side effects by blinded investigators. Patients were also blinded to their group allocation. The tendency to present more severe forms of pruritus was compared between groups. NNT was also determined. Patients assigned to receive droperidol [Proportional odds ratio: 0.45 (95% confidence interval 0.23-0.88)] reported less pruritus than those who received metoclopramide. Ondansetron effect was similar to metoclopramide [Proportional odds ratio: 0.95 (95% confidence interval 0.49-1.83)]. The NNT for droperidol and ondansetron was 4.0 and 14.7, respectively. Ondansetron does not inhibit subarachnoid morphine-induced pruritus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)