840 resultados para shape coefficient
Resumo:
The model of development and evolution of complex morphological structures conceived by Atchley and Hall in 1991 (Biol. Rev. 66:101-157), which establishes that changes at the macroscopic, morphogenetic level can be statistically detected as variation in skeletal units at distinct scales, was applied in combination with the formalism of geometric morphometrics to study variation in mandible shape among populations of the rodent species Thrichomys apereoides. The thin-plate spline technique produced geometric descriptors of shape derived from anatomical landmarks in the mandible, which we used with graphical and inferential approaches to partition the contribution of global and localized components to the observed differentiation in mandible shape. A major pattern of morphological differentiation in T. apereoides is attributable to localized components of shape at smaller geometric scales associated with specific morphogenetic units of the mandible. On the other hand, a clinal trend of variation is associated primarily with localized components of shape at larger geometric scales. Morphogenetic mechanisms assumed to be operating to produce the observed differentiation in the specific units of the mandible include mesenchymal condensation differentiation, muscle hypertrophy, and tooth growth. Perspectives for the application of models of morphological evolution and geometric morphometrics to morphologically based systematic biology are considered.
Resumo:
A general form for ladder operators is used to construct a method to solve bound-state Schrödinger equations. The characteristics of supersymmetry and shape invariance of the system are the start point of the approach. To show the elegance and the utility of the method we use it to obtain energy spectra and eigenfunctions for the one-dimensional harmonic oscillator and Morse potentials and for the radial harmonic oscillator and Coulomb potentials.
Resumo:
The study of the association between two random variables that have a joint normal distribution is of interest in applied statistics; for example, in statistical genetics. This article, targeted to applied statisticians, addresses inferences about the coefficient of correlation (ρ) in the bivariate normal and standard bivariate normal distributions using likelihood, frequentist, and Baycsian perspectives. Some results are surprising. For instance, the maximum likelihood estimator and the posterior distribution of ρ in the standard bivariate normal distribution do not follow directly from results for a general bivariate normal distribution. An example employing bootstrap and rejection sampling procedures is used to illustrate some of the peculiarities.
Resumo:
Three types of raw materials including commercial waste from saltwater (SW), freshwater fish (FW) and tilapia fillet residue (FR) were used to produce fish silage by either acid digestion (2% formic acid and 2% sulfuric acid) or anaerobic fermentation (5% of Lactobacillus plantarum and 15% sugar cane molasses). Six test diets were used in digestibility trials prepared with 70% reference diet and 30% of each experimental silage. These diets were fed to juvenile pacu Piaractus mesopotamicus (146 g average weight) in triplicate. Fish were kept in 500-L tanks and feces collected by manual extrusion. It was observed for both processes that SW waste always had the highest moisture content and lowest fat and ash. Highest crude protein levels were found in silages from commercial fish waste (SW and FW) made from whole fish unfit for human consumption. However, apparent digestibility coefficients did not vary among diets (P > 0.05). Although values did not differ statistically, fermented silage consistently displayed higher digestibility coefficients compared to acid silage. The silages exhibited relatively high protein digestibility (72.5-80.0%), thus suggesting the feasibility of using fish industry by-products in aquaculture feeds.
Resumo:
This article presents a quantitative and objective approach to cat ganglion cell characterization and classification. The combination of several biologically relevant features such as diameter, eccentricity, fractal dimension, influence histogram, influence area, convex hull area, and convex hull diameter are derived from geometrical transforms and then processed by three different clustering methods (Ward's hierarchical scheme, K-means and genetic algorithm), whose results are then combined by a voting strategy. These experiments indicate the superiority of some features and also suggest some possible biological implications.
Resumo:
This comment criticizes the recently published approach of Alhaidari for solving relativistic problems. It is shown that his gauge considerations are inaccurate and that the class of exactly solvable relativistic problems is not as large as the author claims.
Resumo:
A very simple and robust method for ceramics grains quantitative image analysis is presented. Based on the use of optimal imaging conditions for reflective light microscopy of bulk samples, a digital image processing routine was developed for shading correction, noise suppressing and contours enhancement. Image analysis was done for grains selected according to their concavities, evaluated by perimeter ratio shape factor, to avoid consider the effects of breakouts and ghost boundaries due to ceramographic preparation limitations. As an example, the method was applied for two ceramics, to compare grain size and morphology distributions. In this case, most of artefacts introduced by ceramographic preparation could be discarded due to the use of perimeter ratio exclusion range.
Resumo:
Erbium activated SiO2 -HfO2 planar waveguides, doped with Er3+ concentrations ranging from 0.01 to 4 mol%, were prepared by sol-gel method. The films were deposited on v-SiO2 and silica-on-silicon substrates using dip-coating technique. The waveguides show high densification degree, effective intermingling of the two film components, and uniform surface morphology. The waveguide deposited on silica-on-silicon substrates shows one single propagation mode at 1.5μm, with a confinement coefficient of 0.81 and an attenuation coefficient of 0.8 dB/cm at 632.8nm. Emission in the C-telecommunication band was observed at room temperature for all the samples upon continuouswave excitation at 980 nm or 514.5 nm. The shape of the emission band corresponding to the 4I13/2 → 4I15/2 transition is found to be almost independent both on erbium content and excitation wavelength, with a FWHM between 44 and 48 nm. The 4I13/2 level decay curves presented a single-exponential profile, with a lifetime ranging between 1.1 - 6.6 ms, depending on the erbium concentration. Infrared to visible upconversion luminescence upon continuous-wave excitation at 980 nm was observed for all the samples. Channel waveguide in rib configuration was obtained by etching the active film in order to have a well confined mode at 1.5 μm.
Resumo:
This papers presents results on the variation of the PMD coefficient of optical links under influence of mechanical tests, such as tensile strength, bending and compression, and also during the application of a thermal cycle. Results revealed that the link coefficient is more influenced by the application of a tension load and also suffers significant variation under strong temperature changes. Copyrigth © SBMO.
Resumo:
This work presents the implementation of the ultrasonic shear reflectance method for viscosity measurement of Newtonian liquids using wave mode conversion from longitudinal to shear waves and vice-versa. The method is based on measuring the complex reflection coefficient (magnitude and phase) at a solid-liquid interface. Viscosity measurements were made in the range from 1 to 3.5MHz at 22.5°C for automotive oil (SAE40) and at 15°C for olive oil. Moreover, measurements of the olive oil were also conducted in the range from 15 to 30°C at 3.5MHz. The experimental results agree with those provided by a rotational viscometer. © 2006 IEEE.
Resumo:
This work describes a fabrication and test sequence of microvalves installed on micronozzles. The technique used to fabricate the micronozzles was powder blasting. The microvalves are actuators made from PVDF (polivinylidene fluoride), that is a piezoelectric polymer. The micronozzles have convergent-divergent shape with external diameter of 1mm and throat around 230μm. The polymer have low piezoelectric coefficient, for this reason a bimorph structure with dimensions of 2mm width and 4mm of length was build (two piezoelectric sheets were glued together with opposite polarization). Both sheets are recovered with a conductor thin film used as electrodes. Applying a voltage between the electrodes one sheet expands while the other contracts and this generate a vertical movement to the entire actuator. Appling +300V DC between the electrodes the volume flux rate, for a pressure ratio of 0.5, was 0.36 sccm. Applying -200V DC between the electrodes (that means it closed) the volume flux rate was 0.32 sccm, defining a possible range of flow between 0.32 and 0.36 sccm. The third measurement was performed using AC voltage (200V AC with frequency of 1Hz), where the actuator was oscillating. For pressure ratio of 0.5, the flow rate was 0.62 sccm. © 2008 IOP Publishing Ltd.
Resumo:
Includes bibliography
Resumo:
This paper focuses on the magnetoelectric coupling (ME) at room temperature in lanthanum modified bismuth ferrite thin film (BLFO) deposited on SrRuO 3-buffered Pt/TiO 2/SiO 2/Si(100) substrates by the soft chemical method. BLFO film was coherently grown at a temperature of 500 °C. The magnetoelectric coefficient measurement was performed to evidence magnetoelectric coupling behavior. Room temperature magnetic coercive field indicates that the film is magnetically soft. The maximum magnetoelectric coefficient in the longitudinal direction was close to 12 V/cmOe. Dielectric permittivity and dielectric loss demonstrated only slight dispersion with frequency due the less two-dimensional stress in the plane of the film. Polarization reversal was investigated by applying dc voltage through a conductive tip during the area scanning. We observed that various types of domain behavior such as 71 ° and 180° domain switching, and pinned domain formation occurred. Copyright © 2009 American Scientific Publishers All rights reserved.
Resumo:
The determination of the reflection coefficient of shear waves reflected from a solid-liquid interface is an important method in order to study the viscoelastic properties of liquids at high frequency. The reflection coefficient is a complex number. While the magnitude measurement is relatively easy and precise, the phase measurement is very difficult due to its strong temperature dependence. For that reason, most authors choose a simplified method in order to obtain the viscoelastic properties of liquids from the measured coefficient. In this simplified method, inconsistent viscosity results are obtained because pure viscous behavior is assumed and the phase is not measured. This work deals with an effort to improve the experimental technique required to measure both the magnitude and phase of the reflection coefficient and it intends to report realistic values for oils in a wide range of viscosity (0.092 - 6.7 Pa.s). Moreover, a device calibration process is investigated in order to monitor the dynamic viscosity of the liquid.