831 resultados para screening
Resumo:
To assess the value of conducting a glaucoma screening randomized controlled trial in the UK.
Resumo:
There is substantial international variation in human papillomavirus (HPV) prevalence; this study details the first report from Northern Ireland and additionally provides a systematic review and meta-analysis pooling the prevalence of high-risk (HR-HPV) subtypes among women with normal cytology in the UK and Ireland. Between February and December 2009, routine liquid based cytology (LBC) samples were collected for HPV detection (Roche Cobas® 4800 [PCR]) among unselected women attending for cervical cytology testing. Four electronic databases, including MEDLINE, were then searched from their inception till April 2011. A random effects meta-analysis was used to calculate a pooled HR-HPV prevalence and associated 95% confidence intervals (CI). 5,712 women, mean age 39 years (±SD 11.9 years; range 20-64 years), were included in the analysis, of which 5,068 (88.7%), 417 (7.3%) and 72 (1.3%) had normal, low, and high-grade cytological findings, respectively. Crude HR-HPV prevalence was 13.2% (95% CI, 12.7-13.7) among women with normal cytology and increased with cytological grade. In meta-analysis the pooled HR-HPV prevalence among those with normal cytology was 0.12 (95% CIs, 0.10-0.14; 21 studies) with the highest prevalence in younger women. HPV 16 and HPV 18 specific estimates were 0.03 (95% CI, 0.02-0.05) and 0.01 (95% CI, 0.01-0.02), respectively. The findings of this Northern Ireland study and meta-analysis verify the prevalent nature of HPV infection among younger women. Reporting of the type-specific prevalence of HPV infection is relevant for evaluating the impact of future HPV immunization initiatives, particularly against HR-HPV types other than HPV 16 and 18. J. Med. Virol. 85:295-308, 2013. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.
Resumo:
Obesity has consistently been linked to an increased risk of colorectal cancer, particularly among men. Whether body mass index (BMI) differentially influences the risk across the stages of colorectal cancer development remains unclear. We evaluated the associations of BMI with colorectal adenoma incidence, adenoma recurrence, and cancer in the context of a large screening trial, in which cases and controls had an equal chance for disease detection.
Resumo:
A lateral flow immunoassay (LFIA) has been developed and fully validated to detect the primary amnesic shellfish poisoning (ASP) toxin, domoic acid (DA). The performance characteristics of two versions of the test were investigated using spiked and naturally contaminated shellfish (mussels, scallops, oysters, clams, and cockles). The tests provide a qualitative result, to indicate the absence or presence of DA in extracts of shellfish tissues, at concentrations that are relevant to regulatory limits. The new rapid assay (LFIA version 2) was designed to overcome the performance limitations identified in the first version of the assay. The improved test uses an electronic reader to remove the subjective nature of the generated results, and the positive cut-off for screening of DA in shellfish was increased from 10 ppm (version 1) to 17.5 ppm (version 2). A simple extraction and test procedure was employed, which required minimal equipment and materials; results were available 15 min after sample preparation. Stability of the aqueous extracts at room temperature (22 C) at four time points (up to 245 min after extraction) and across a range of DA concentrations was 100.3±1.3% and 98.8±2.4% for pre- and post-buffered extracts, respectively. The assay can be used both within laboratory settings and in remote locations. The accuracy of the new assay, to indicate negative results at or below 10 ppm DA, and positive results at or above 17.5 ppm, was 99.5% (n=216 tests). Validation data were obtained from a 2-day, randomised, blind study consisting of multiple LFIA lots (n=3), readers (n=3) and operators (n=3), carrying out multiple extractions of mussel tissue (n=3) at each concentration (0, 10, 17.5, and 20 ppm). No matrix effects were observed on the performance of the assay with different species (mussels, scallops, oysters, clams, and cockles). There was no impact on accuracy or interference from other phycotoxins, glutamic acid or glutamine with various strip incubations (8, 10, and 12 min). The accuracy of the assay, using naturally contaminated samples to indicate negative results at or below 12.5 ppm and positive results at or above 17.5 ppm, was 100%. Variability between three LFIA lots across a range of DA concentrations, expressed as coefficient of variation (% CV), was 1.1±0.4% (n=2 days) based on quantitative readings from the electronic reader. During an 8 week stability study, accuracy of the method with test strips stored at various temperatures (6, 22, 37 and 50 C) was 100%. Validation for both versions included comparisons with results obtained using reference LC-UV methods. © 2013 Elsevier B.V.
Resumo:
Despite the significant burden of cervical cancer, Malaysia like many middle-income countries relies on opportunistic cervical screening as opposed to a more organized population-based program. The aim of this study was to ascertain the effectiveness of a worksite screening initiative upon Papanicolaou smear test (Pap test) uptake among educated working women in Malaysia.
Resumo:
The fundamental understanding of the activity in heterogeneous catalysis has long been the major subject in chemistry. This paper shows the development of a two-step model to understand this activity. Using the theory of chemical potential kinetics with Bronsted-Evans-Polanyi relations, the general adsorption energy window is determined from volcano curves, using which the best catalysts can be searched. Significant insights into the reasons for catalytic activity are obtained.
Resumo:
The presence of mobile ions complicates the implementation of voltage-modulated scanning probe microscopy techniques such as Kelvin probe force microscopy (KPFM). Overcoming this technical hurdle, however, provides a unique opportunity to probe ion dynamics and electrochemical processes in liquid environments and the possibility to unravel the underlying mechanisms behind important processes at the solid–liquid interface, including adsorption, electron transfer and electrocatalysis. Here we describe the development and implementation of electrochemical force microscopy (EcFM) to probe local bias- and time-resolved ion dynamics and electrochemical processes at the solid–liquid interface. Using EcFM, we demonstrate contact potential difference measurements, consistent with the principles of open-loop KPFM operation. We also demonstrate that EcFM can be used to investigate charge screening mechanisms and electrochemical reactions in the probe–sample junction. We further establish EcFM as a force-based imaging mode, allowing visualization of the spatial variability of sample-dependent local electrochemical properties.
Resumo:
A highly sensitive broad specificity monoclonal antibody was produced and characterised for microcystin detection through the development of a rapid surface plasmon resonance (SPR) optical biosensor based immunoassay. The antibody displayed the following cross-reactivity: MC-LR 100%; MC-RR 108%; MC-YR 68%; MC-LA 69%; MC-LW 71%; MC-LF 68%; and Nodularin 94%. Microcystin-LR was covalently attached to a CM5 chip and with the monoclonal antibody was employed in a competitive 4min injection assay to detect total microcystins in water samples below the WHO recommended limit (1µg/L). A 'total microcystin' level was determined by measuring free and intracellular concentrations in cyanobacterial culture samples as this toxin is an endotoxin. Glass bead beating was used to lyse the cells as a rapid extraction procedure. This method was validated according to European Commission Decision 96/23/EC criteria. The method was proven to measure intracellular microcystin levels, the main source of the toxin, which often goes undetected by other analytical procedures and is advantageous in that it can be used for the monitoring of blooms to provide an early warning of toxicity. It was shown to be repeatable and reproducible, with recoveries from spiked samples ranging from 74 to 123%, and had % CVs below 10% for intra-assay analysis and 15% for inter-assay analysis. The detection capability of the assay was calculated as 0.5ng/mL for extracellular toxins and 0.05ng/mL for intracellular microcystins. A comparison of the SPR method with LC-MS/MS was achieved by testing six Microcystis aeruginosa cultures and this study yielded a correlation R(2) value of 0.9989.
Resumo:
BACKGROUND: Family-based cardiac screening programmes for persons at risk for genetic cardiac diseases are now recommended. However, the psychological wellbeing and health related quality of life (QoL) of such screened patients is poorly understood, especially in younger patients. We sought to examine wellbeing and QoL in a representative group of adults aged 16 and over in a dedicated family cardiac screening clinic.
METHODS: Prospective survey of consecutive consenting patients attending a cardiac screening clinic, over a 12 month period. Data were collected using two health measurement tools: the Short Form 12 (version 2) and the Hospital Anxiety and Depression Scale (HADS), along with baseline demographic and screening visit-related data. The HADS and SF-12v.2 outcomes were compared by age group. Associations with a higher HADS score were examined using logistic regression, with multi-level modelling used to account for the family-based structure of the data.
RESULTS: There was a study response rate of 86.6%, with n=334 patients providing valid HADS data (valid response rate 79.5%), and data on n=316 retained for analysis. One-fifth of patients were aged under 25 (n=61). Younger patients were less likely than older to describe significant depression on their HADS scale (p<0.0001), although there were overall no difference between the prevalence of a significant HADS score between the younger and older age groups (18.0% vs 20.0%, p=0.73). Significant positive associates of a higher HADS score were having lower educational attainment, being single or separated, and being closely related to the family proband. Between-family variance in anxiety and depression scores was greater than within-family variance.
CONCLUSIONS: High levels of anxiety were seen amongst patients attending a family-based cardiac screening clinic.Younger patients also had high rates of clinically significant anxiety. Higher levels of anxiety and depression tends to run in families, and this has implications for family screening and intervention programmes.
Resumo:
Antimicrobial residues found to be present in milk can have both health and economic impacts. For these reasons, the widespread routine testing of milk is required. Due to delays with sample handling and test scheduling, laboratory-based tests are not always suited for making decisions about raw material intake and product release, especially when samples require shipping to a central testing facility. Therefore, rapid on-site screening tests that can produce results within a matter of minutes are required to facilitate rapid intake and product release processes. Such tests must be simple for use by non-technical staff. There is increasing momentum towards the development and implementation of multiplexing tests that can detect a range of important antimicrobial residues simultaneously. A simple in situ multiplexed planar waveguide device that can simultaneously detect chloramphenicol, streptomycin and desfuroylceftiofur in raw dairy milk, without sample preparation, has been developed. Samples are simply mixed with antibody prior to an aliquot being passed through the detection cartridge for 5 min before reading on a field-deployable portable instrument. Multiplexed calibration curves were produced in both buffer and raw milk. Buffer curves, for chloramphenicol, streptomycin and desfuroylceftiofur, showed linear ranges (inhibitory concentration (IC)20–IC80) of 0.1–0.9, 3–129 and 12–26 ng/ml, whilst linear range in milk was 0.13–0.74, 11–376 and 2–12 ng/ml, respectively, thus meeting European legislated concentration requirements for both chloramphenicol and streptomycin, in milk, without the need for any sample preparation. Desfuroylceftiofur-contaminated samples require only simple sample dilution to bring positive samples within the range of quantification. Assay repeatability and reproducibility were lower than 12 coefficient of variation (%CV), whilst blank raw milk samples (n = 9) showed repeatability ranging between 4.2 and 8.1 %CV when measured on all three calibration curves.