894 resultados para quantitative ultrasound
Resumo:
Human herpesvirus 6 (HHV-6) may cause severe complications after haematopoietic stem cell transplantation (HSCT). Monitoring this virus and providing precise, rapid and early diagnosis of related clinical diseases, constitute essential measures to improve outcomes. A prospective survey on the incidence and clinical features of HHV-6 infections after HSCT has not yet been conducted in Brazilian patients and the impact of this infection on HSCT outcome remains unclear. A rapid test based on real-time quantitative polymerase chain reaction (qPCR) has been optimised to screen and quantify clinical samples for HHV-6. The detection step was based on reaction with TaqMan® hydrolysis probes. A set of previously described primers and probes have been tested to evaluate efficiency, sensitivity and reproducibility. The target efficiency range was 91.4% with linearity ranging from 10-106 copies/reaction and a limit of detection of five copies/reaction or 250 copies/mL of plasma. The qPCR assay developed in the present study was simple, rapid and sensitive, allowing the detection of a wide range of HHV-6 loads. In conclusion, this test may be useful as a practical tool to help elucidate the clinical relevance of HHV-6 infection and reactivation in different scenarios and to determine the need for surveillance.
Resumo:
Malgrat la rellevància estratègica i el paper desestabilitzador de Corea del Nord a la regió econòmicament més dinàmica del món, la UE no compta amb cap estratègia clara per involucrar-se amb aquest país. Combinant tècniques d’anàlisi qualitatives i quantitatives, aquest treball pretén descobrir possibles contradiccions internes que impedeixin la definició d'una política exterior europea coherent i efectiva amb respecte a Corea del Nord, així com discrepàncies entre les percepcions d’actors interns de la UE i les d’actors externs. S'han detectat importants diferències d’expectatives i mancances en termes de coherència, tant entre les visions expressades pels actors interns com entre les opinions d’aquests actors i les dels futurs líders sudcoreans enquestats – diferències que fins i tot afecten la promoció dels drets humans
Resumo:
OBJECTIVES: The objective of this study is to describe the prenatal sonographic features and the results of DNA analysis on three fetuses with dyssegmental dysplasia, Silverman-Handmaker type (DD-SH). METHODS: A retrospective review of three fetuses with confirmed DD-SH was conducted. The fetal ultrasound findings, the radiological characteristics, and the results of the mutation analysis of the heparan sulphate perlecan gene 2 (HSPG2) were reviewed. RESULTS: There were three cases in two families with DD-SH diagnosed prenatally. The main prenatal ultrasound and the radiological features of DD-SH were severe limb shortening and vertebral segmentation and fusion defects (anisospondyly). The DNA analysis of the HSPG2 gene showed that the two affected fetuses in a nonconsanguineous family had a compound heterozygote for the c.646G > T transversion in exon 7 and a c.5788C > T transition in exon 46. The fetus born to the consanguineous couple had a homozygous mutation c.1356-27_1507 + 59del. CONCLUSION: DD-SH can be diagnosed prenatally using fetal ultrasound as early as 13 weeks. Xrays and DNA analysis of the HSPG2 gene are important for the confirmation of the diagnosis and for the preimplantation and prenatal diagnosis in pregnancies at risk. © 2013 John Wiley & Sons, Ltd.
Resumo:
During the Early Toarcian, major paleoenvironnemental and paleoceanographical changes occurred, leading to an oceanic anoxic event (OAE) and to a perturbation of the carbon isotope cycle. Although the standard biochronology of the Lower Jurassic is essentially based upon ammonites, in recent years biostratigraphy based on calcareous nannofossils and dinoflagellate cysts is increasingly used to date Jurassic rocks. However, the precise dating and correlation of the Early Toarcian OAE, and of the associated delta C-13 anomaly in different settings of the western Tethys, are still partly problematic, and it is still unclear whether these events are synchronous or not. In order to allow more accurate correlations of the organic rich levels recorded in the Lower Toarcian OAE, this account proposes a new biozonation based on a quantitative biochronology approach, the Unitary Associations (UA), applied to calcareous nannofossils. This study represents the first attempt to apply the UA method to Jurassic nannofossils. The study incorporates eighteen sections distributed across western Tethys and ranging from the Pliensbachian to Aalenian, comprising 1220 samples and 72 calcareous nannofossil taxa. The BioGraph [Savary, J., Guex, J., 1999. Discrete biochronological scales and unitary associations: description of the Biograph Computer program. Memoires de Geologie de Lausanne 34, 282 pp] and UA-Graph (Copyright Hammer O., Guex and Savary, 2002) softwares provide a discrete biochronological framework based upon multi-taxa concurrent range zones in the different sections. The optimized dataset generates nine UAs using the co-occurrences of 56 taxa. These UAs are grouped into six Unitary Association Zones (UA-Z), which constitute a robust biostratigraphic synthesis of all the observed or deduced biostratigraphic relationships between the analysed taxa. The UA zonation proposed here is compared to ``classic'' calcareous nannofossil biozonations, which are commonly used for the southern and the northern sides of Tethys. The biostratigraphic resolution of the UA-Zones varies from one nannofossil subzone or part of it to several subzones, and can be related to the pattern of calcareous nannoplankton originations and extinctions during the studied time interval. The Late Pliensbachian - Early Toarcian interval (corresponding to the UA-Z II) represents a major step in the Jurassic nannoplankton radiation. The recognized UA-Zones are also compared to the carbon isotopic negative excursion and TOC maximum in five sections of central Italy, Germany and England, with the aim of providing a more reliable correlation tool for the Early Toarcian OAE, and of the associated isotopic anomaly, between the southern and northern part of western Tethys. The results of this work show that the TOC maximum and delta C-13 negative excursion correspond to the upper part of the UA-Z II (i.e., UA 3) in the sections analysed. This suggests that the Early Toarcian OAE was a synchronous event within the western Tethys. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND We evaluated a newly designed electronic portfolio (e-Portfolio) that provided quantitative evaluation of surgical skills. Medical students at the University of Seville used the e-Portfolio on a voluntary basis for evaluation of their performance in undergraduate surgical subjects. METHODS Our new web-based e-Portfolio was designed to evaluate surgical practical knowledge and skills targets. Students recorded each activity on a form, attached evidence, and added their reflections. Students self-assessed their practical knowledge using qualitative criteria (yes/no), and graded their skills according to complexity (basic/advanced) and participation (observer/assistant/independent). A numerical value was assigned to each activity, and the values of all activities were summated to obtain the total score. The application automatically displayed quantitative feedback. We performed qualitative evaluation of the perceived usefulness of the e-Portfolio and quantitative evaluation of the targets achieved. RESULTS Thirty-seven of 112 students (33%) used the e-Portfolio, of which 87% reported that they understood the methodology of the portfolio. All students reported an improved understanding of their learning objectives resulting from the numerical visualization of progress, all students reported that the quantitative feedback encouraged their learning, and 79% of students felt that their teachers were more available because they were using the e-Portfolio. Only 51.3% of students reported that the reflective aspects of learning were useful. Individual students achieved a maximum of 65% of the total targets and 87% of the skills targets. The mean total score was 345 ± 38 points. For basic skills, 92% of students achieved the maximum score for participation as an independent operator, and all achieved the maximum scores for participation as an observer and assistant. For complex skills, 62% of students achieved the maximum score for participation as an independent operator, and 98% achieved the maximum scores for participation as an observer or assistant. CONCLUSIONS Medical students reported that use of an electronic portfolio that provided quantitative feedback on their progress was useful when the number and complexity of targets were appropriate, but not when the portfolio offered only formative evaluations based on reflection. Students felt that use of the e-Portfolio guided their learning process by indicating knowledge gaps to themselves and teachers.
Resumo:
Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV
Resumo:
BACKGROUND: Ultrasound Biomicroscopy (UBM) is a new ophthalmological imaging technique essentially designed for the study of the anterior eye segment. Over the last 10 months, we've evaluated its contribution to the conservative treatment of anterior uveal melanoma's by means of accelerated proton beam irradiation. MATERIAL: Using UBM, we have examined 55 cases of uveal melanoma's, whose anterior border was situated at 6 mm or less from the limbus and that were consequently treated by proton beam irradiation. RESULTS: The presumed tumoral origin was the ciliary body's pars plicata in 13 cases and the pars plana or the choroid in 42 cases, 17 of which presented a tumoral invasion of the pars plicata. A pars plana detachment anterior to or surrounding the anterior tumoral border, was present in 22 cases. The height of the tumor could only be measured by UBM if it was less than 2.5 mm. Information gathered using UBM have contributed to an improvement of the therapy plan in 32 cases. CONCLUSION: Because of the strong attenuation of the high frequency ultrasound signal, UBM can only be used for the examination of intra-ocular structures situated in direct neighbourhood to the global wall. Despite this technical limitation, ist contribution to the planning of the conservative treatment of anterior uveal melanoma's by proton beam irradiation has appeared to be considerable.
Resumo:
We improved, evaluated, and used Sanger sequencing for quantification of single nucleotide polymorphism (SNP) variants in transcripts and gDNA samples. This improved assay resulted in highly reproducible relative allele frequencies (e.g., for a heterozygous gDNA 50.0+/-1.4%, and for a missense mutation-bearing transcript 46.9+/-3.7%) with a lower detection limit of 3-9%. It provided excellent accuracy and linear correlation between expected and observed relative allele frequencies. This sequencing assay, which can also be used for the quantification of copy number variations (CNVs), methylations, mosaicisms, and DNA pools, enabled us to analyze transcripts of the FBN1 gene in fibroblasts and blood samples of patients with suspected Marfan syndrome not only qualitatively but also quantitatively. We report a total of 18 novel and 19 known FBN1 sequence variants leading to a premature termination codon (PTC), 26 of which we analyzed by quantitative sequencing both at gDNA and cDNA levels. The relative amounts of PTC-containing FBN1 transcripts in fresh and PAXgene-stabilized blood samples were significantly higher (33.0+/-3.9% to 80.0+/-7.2%) than those detected in affected fibroblasts with inhibition of nonsense-mediated mRNA decay (NMD) (11.0+/-2.1% to 25.0+/-1.8%), whereas in fibroblasts without NMD inhibition no mutant alleles could be detected. These results provide evidence for incomplete NMD in leukocytes and have particular importance for RNA-based analyses not only in FBN1 but also in other genes.
Resumo:
OBJECTIVE.: Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. INTERVENTIONS.: In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. RESULTS.: Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. CONCLUSIONS.: The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks.
Resumo:
This article describes the composition of fingermark residue as being a complex system with numerous compounds coming from different sources and evolving over time from the initial composition (corresponding to the composition right after deposition) to the aged composition (corresponding to the evolution of the initial composition over time). This complex system will additionally vary due to effects of numerous influence factors grouped in five different classes: the donor characteristics, the deposition conditions, the substrate nature, the environmental conditions and the applied enhancement techniques. The initial and aged compositions as well as the influence factors are thus considered in this article to provide a qualitative and quantitative review of all compounds identified in fingermark residue up to now. The analytical techniques used to obtain these data are also enumerated. This review highlights the fact that despite the numerous analytical processes that have already been proposed and tested to elucidate fingermark composition, advanced knowledge is still missing. Thus, there is a real need to conduct future research on the composition of fingermark residue, focusing particularly on quantitative measurements, aging kinetics and effects of influence factors. The results of future research are particularly important for advances in fingermark enhancement and dating technique developments.
Resumo:
PURPOSE: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. MATERIALS AND METHODS: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age ± standard deviation, 25 years ± 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test. RESULTS: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 ± 34 versus 52 ± 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 ± 47 versus 67 ± 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% ± 9 versus 50% ± 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference. CONCLUSION: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T.
Resumo:
Purpose: To describe low mechanical index grey scale contrast enhanced breast ultrasound in patients with intraductal echogenic material in the differentiation of papillomas from intraductal secretions. Methods and materials: In five patients with echographically detected ductal dilatation containing echogenic material low mechanical index grey scale contrast enhanced ultrasonography was performed. No patient had nipple discharge. The examination was performed with a 9 MHz linear transducer after injection of 4 ml of Sonovue. It was assessed if contrast enhancement was present or not. The results were correlated with histologic results after surgical resection or percutaneous biopsy when performed. Results: In 3 patients contrast enhancement was observed. These patients were operated and the papillomas confirmed by histology. In two patients no contrast enhancement was observed. In one of these two patients percutaneous biopsy was performed without evidence of a papillary lesion. The second patient presented with multiple dilated ducts containing echogenic material. No biopsy was performed but breast MRI showed no intraductal enhancement supporting the non papillary nature of the intraductal material. Conclusion: This pilot study shows that contrast enhanced ultrasound is able to detect the vascularisation of papillomas and that it may differentiate intraductal papillomas from secretions.