959 resultados para proton-proton scattering


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The X-ray crystal structure of [Pd(eta(3)-allyl)(dppn)]BF4 . CH2Cl2 (1) where dppn = 1,8-bis(diphenylphosphino)naphthalene is reported. Comparison of the conformation of the ligand in 1 with that in the free state shows that there is a relief of strain on complexation analogous to the relief of strain observed upon protonation of proton sponge.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The relationship between use of proton pump inhibitors (PPIs) and histamine-2-receptor antagonists (H2RAs) and pancreatic cancer risk has yet to be examined. Data from a range of studies suggest biologically plausible mechanisms, whereby these drugs (or the conditions for which they are prescribed) may affect pancreatic cancer risk. The objective of this study was to investigate the relationship between use of PPIs/H2RAs and pancreatic cancer risk.

Methods: A nested case – control study was conducted within the UK general practice research database (GPRD). Cases had a diagnosis of exocrine pancreatic cancer and controls were matched to cases on general practice site, sex and year of birth. Exposure to PPIs and to H2RAs since entry into GPRD until 2 years before the diagnosis date (corresponding date in controls) and in the 5 years before the diagnosis date were separately assessed. Conditional logistic regression analyses were used to generate odds ratios (ORs) and 95% confidence intervals (CIs) associated with PPI or H2RA use compared with nonuse.

Results: Ever use of PPIs since entry into the GPRD (excluding the 2 years prior to diagnosis) was not associated with risk of pancreatic cancer; OR (95% CI) 1.02 (0.85 – 1.22). Neither the dose nor the duration of PPI or H2RA use was associated with pancreatic cancer risk. No consistent patterns of association were seen when cumulative exposure (dose and duration) to these drugs was examined separately or together.

Conclusion: PPI/H2RA use, in a UK population, was not associated with pancreatic cancer risk.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The transverse filamentation of beams of fast electrons transported in solid targets irradiated by ultraintense (5 x 10(20) W cm(-2)), picosecond laser pulses is investigated experimentally. Filamentation is diagnosed by measuring the uniformity of a beam of multi-MeV protons accelerated by the sheath field formed by the arrival of the fast electrons at the rear of the target, and is investigated for metallic and insulator targets ranging in thickness from 50 to 1200 mu m. By developing an analytical model, the effects of lateral expansion of electron beam filaments in the sheath during the proton acceleration process is shown to account for measured increases in proton beam nonuniformity with target thickness for the insulating targets.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Laser-driven proton and ion acceleration is an area of increasing research interest given the recent development of short pulse-high intensity lasers. Several groups have reported experiments to understand whether a laser-driven beam can be applied for radiobiological purposes and in each of these, the method to obtain dose and spectral analysis was slightly different. The difficulty with these studies is that the very large instantaneous dose rate is a challenge for commonly used dosimetry techniques, so that other more sophisticated procedures need to be explored. This paper aims to explain a method for obtaining the energetic spectrum and the dose of a laser-driven proton beam irradiating a cell dish used for radiobiology studies. The procedure includes the use of a magnet to have charge and energy separation of the laser-driven beam, Gafchromic films to have information on dose and partially on energy, and a Monte Carlo code to expand the measured data in order to obtain specific details of the proton spectrum on the cells. Two specific correction factors have to be calculated: one to take into account the variation of the dose response of the films as a function of the proton energy and the other to obtain the dose to the cell layer starting from the dose measured on the films. This method, particularly suited to irradiation delivered in a single laser shot, can be applied in any other radiobiological experiment performed with laser-driven proton beams, with the only condition that the initial proton spectrum has to be at least roughly known. The method was tested in an experiment conducted at Queen's University of Belfast using the TARANIS laser, where the mean energy of the protons crossing the cells was between 0.9 and 5 MeV, the instantaneous dose rate was estimated to be close to 10(9) Gy s(-1) and doses between 0.8 and 5 Gy were delivered to the cells in a single laser shot. The combination of the applied corrections modified the initial estimate of dose by up to 40%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of two separate ultraintense laser pulses in laser-proton acceleration was compared to the single pulse case employing the same total laser energy. A double pulse profile, with the temporal separation of the pulses varied between 0.75-2.5 ps, was shown to result in an increased maximum proton energy and an increase in conversion efficiency to fast protons by up to a factor of 3.3. Particle-in-cell simulations indicate the existence of a two stage acceleration process. The second phase, induced by the main pulse preferentially accelerates slower protons located deeper in the plasma, in contrast to conventional target normal sheath acceleration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thin Al foils (50 nm and 6 mu m) were irradiated at intensities of up to 2x10(19) W cm(-2) using high contrast (10(8)) laser pulses. Ion emission from the rear of the targets was measured using a scintillator-based Thomson parabola and beam sampling 'footprint' monitor. The variation of the ion spectra and beam profile with focal spot size was systematically studied. The results show that while the maximum proton energy is achieved around tight focus for both target thicknesses, as the spot size increases the ion flux at lower energies is seen to peak at significantly increased spot sizes. Measurements of the proton footprint, however, show that the off-axis proton flux is highest at tight focus, indicating that a previously identified proton deflection mechanism may alter the on-axis spectrum. One-dimensional particle-in-cell modelling of the experiment supports our hypothesis that the observed change in spectra with focal spot size is due to the competition of two effects: decrease in laser intensity and an increase in proton emission area.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Target normal measurements of proton energy spectra from ultrathin (50-200 nm) planar foil targets irradiated by 10(19) W cm(-2) 40 fs laser pulses exhibit broad maxima that are not present in the energy spectra from micron thickness targets (6 mu m). The proton flux in the peak is considerably greater than the proton flux observed in the same energy range in thicker targets. Numerical modelling of the experiment indicates that this spectral modification in thin targets is caused by magnetic fields that grow at the rear of the target during the laser-target interaction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The properties of beams of high energy protons accelerated during ultraintense, picosecond laser-irradiation of thin foil targets are investigated as a function of preplasma expansion at the target front surface. Significant enhancement in the maximum proton energy and laser-to-proton energy conversion efficiency is observed at optimum preplasma density gradients due, to self-focusing Of the incident laser pulse. For very long preplasma expansion, the propagating laser pulse is observed to filament, resulting in highly uniform proton beams, but with reduced flux and maximum energy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The possibility of using high-power lasers to generate high-quality beams of energetic ions is attracting large global interest. The prospect of using laser-accelerated protons in medicine attracts particular interest, as these schemes may lead to compact and relatively low-cost sources. Among the challenges remaining before these sources can be used in medicine is to increase the numbers and energies of the ions accelerated. Here, we extend the energy and intensity range over which proton scaling is experimentally investigated, up to 400 J and 6 x 10(20) W cm(-2) respectively, and find a slower proton scaling than previously predicted. With the aid of plasma-expansion simulation tools, our results suggest the importance of time-dependent and multidimensional effects in predicting the maximum proton energy in this ultrahigh-intensity regime. The implications of our new understanding of proton scaling for potential medical applications are discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Protons with energies up to 18 MeV have been measured from high density laser-plasma interactions at incident laser intensities of 5 X 10(19) W/cm(2). Up to 10(12) protons with energies greater than 2 MeV were observed to propagate through a 125 mu m thick aluminum target and measurements of their angular deflection were made. It is likely that the protons originate from the front surface of the target and are bent by large magnetic fields which exist in the target interior. To agree with our measurements these fields would be in excess of 30 MG and would be generated by the beam of fast electrons which is also observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The spatial energy distributions of beams of protons accelerated by ultrahigh intensity (> 10(19) W/cm(2)) picosecond laser pulse interactions with thin foil targets are investigated. Using separate, low intensity (