974 resultados para prosthesis pigmentation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

C.difficle surveillance report quarter July-September 2015 .pdf C.difficle surveillance report quarter April-June 2015.pdf C.difficle surveillance report quarter January - March 2015.pdf C.difficle surveillance report quarter ending Oct - Dec 2014.pdf C.difficle surveillance report quarter ending July - Sept 2014.pdf C.difficle sureillance report quarter ending April - June 2014.pdf C.difficle surveillance report quarter endin January - March 2014.pdf C.difficle surveillance report quarter ending October to December 2013.pdf C.difficle surveillance report quarter ending 1st July 2013 to 30th September 2013.pdf C.difficle surveillance report quarter ending 1 April 2013 to 30 June 2013.pdf C.difficle Surveillance Report Quarter Ending 31st March 2013.pdf.pdf C.difficle Surveillance Report Quarter Ending 31st December 2012.pdf C.difficile Surveillance Report quarter ending 30 September 2012.pdf.pdf� C.difficile Surveillance Report quarter ending 30 June 2012.pdf C.difficile Surveillance Report quarter ending March 2012 C.difficile Surveillance Report quarter ending December 2011 C.difficile Surveillance Report quarter ending September 2011.pdf C. difficle Surveillance Report quarter ending June 2011.pdf C. difficile Surveillance Report quarter ending March 2011 (930KB).pdf CDI_Report Oct-Dec 2010_2.pdf Staphylococcus aureus S.aureus bacteraemia surveillance quart July-September 2015.pdf S.aureus surveillance report quarter April-June 2015.pdf S.aureus surveillance report quarter January - March 2015.pdf S.aureus surveillance report quarter Oct - Dec 2014.pdf S.aureus sureveillance report quarter July - Sept 2014.pdf S.aureus surveillance report quarter April - June 2014.pdf S. aureus surveillance report quarter January - March 2014.pdf S. aureus surveillance report quarter ending October to December 2013.pdf S. aureus surveillance report quarter ending 1st July 2013 to 30th September 2013.pdf S. aureus surveillance report quarter ending 1 April 2013 to 30 June 2013 S.aureus Surveillance Report Quarter Ending 31st March 2013.pdf.pdf S.aureus Surveillance Report Quarter Ending 31st December 2012.pdf S.aureus Surveillance Report quarter ending 30 September 2012.pdf.pdf S.aureus Surveillance Report quarter ending 30 June 2012.pdf S.aureus Surveillance Report quarter ending March 2012 S.aureus Surveillance Report quarter ending�December 2011 S.aureus Surveillance Report quarter ending September 2011.pdf S.aureus Surveillance Report quarter ending June 2011.pdf S.aureus Surveillance Report quarter ending March 2011 (999KB).pdf Surgical site infectionCumulative incidence of SSI within 30 days after Caesarean section, Reporting Year 2009 (post-discharge excluded) Cumulative incidence of SSI within 30 days after hip prosthesis, Reporting Year 2009 (post-discharge excluded) Cumulative incidence of SSI within 30 days after knee prosthesis, Reporting Year 2009 (post-discharge excluded) � �

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study intended to characterize the phenotypic and genetic diversity of Brazilian isolates of Chromobacterium violaceum from aquatic environments within the Amazon region. Nineteen isolates showed morphological properties of C. violaceum and the majority grew at 44°C. Low temperatures, in contrast, showed to be inhibitory to their growth, as eleven isolates did not grow at 10ºC and nine did not produce pigmentation, clearly indicating an inhibition of their metabolism. The largest variation among isolates was observed in the citrate test (Simmons), in which 12 isolates were positive, and in the oxidation/fermentation of sucrose, with six positives isolates. Chloramphenicol, gentamicin and sulfonamides efficiently inhibited bacterial growth. Amplified products of the recA gene were digested with HindII or PstI, which produced three or four restriction fragments patterns, respectively. The combined analysis arranged the isolates into six genospecies. The higher diversity observed in Belém (genotypes C, D, E and F) may be a consequence of intense human occupation, pollution of the aquatic environment or due to the higher diversity of the environments sampled in that region. In conclusion, a high level of genetic and phenotypic diversity was observed, and four new genospecies were described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXT: Primary pigmented nodular adrenocortical disease (PPNAD), a rare cause of corticotropin-independent Cushing syndrome, can be part of Carney complex (CNC), an autosomal dominant multiple neoplasia syndrome characterized by spotty skin pigmentation, cardiac myxomas, and endocrine tumors or be isolated (i). Germline PRKAR1A-inactivating mutations have been observed in both CNC and iPPNAD, but with no apparent genotype-phenotype correlation. OBJECTIVE:The objectives of the study were a detailed phenotyping for CNC manifestations in 12 kindreds bearing the same PRKAR1A mutation and a study of the consequences of the mutation and a potential founder effect. DESIGN: The study consisted of descriptive case reports. SETTING: The study was conducted at two referral centers. PATIENTS: The patients described in this study were referred for PRKAR1A gene mutation analysis because of a diagnosis of apparently iPPNAD. RESULTS: We describe a 6-bp polypyrimidine tract deletion [exon 7 IVS del (-7-->-2)] in 12 unrelated kindreds that were referred for Cushing syndrome due to PPNAD. Nine of the patients had no family history; in two, there was a family history of iPPNAD. Only one patient met the criteria for CNC. Relatives carrying the same mutation had no manifestations of CNC or PPNAD, suggesting a low penetrance of this PRKAR1A defect. A founder effect was excluded by extensive genotyping of chromosome 17 markers. CONCLUSIONS: In conclusion, a small intronic deletion of the PRKAR1A gene is a low-penetrance cause of mainly iPPNAD; it is the first PRKAR1A genetic defect to have an association with a specific phenotype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Congenital naevi of the melanocytic system include numerous types, which differ in their clinical appearance, pattern of distribution, and histopathological features (1). Examples are large congenital melanocytic naevus, macular naevus spilus, papular naevus spilus, café-au-lait macules of neurofibromatosis 1, café-au-lait macules arranged in broad bands as noted in McCune-Albright syndrome, partial unilateral lentiginosis, naevus achromicus (naevus depigmentosus), phylloid hypermelanosis, and phylloid hypomelanosis (1–3). We describe here two patients with a systematized pigmentary naevus that differed from all naevi reported so far.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND. Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. METHODS. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. RESULTS. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. CONCLUSIONS. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To date, myxoma on a mechanical valve annulus has not been reported. The case is reported of a 74-year-old woman who was admitted to hospital following the identification of an intracardiac tumor mass. Six years previously, the patient had received a mechanical valve implanted in the mitral position. Transesophageal echocardiography revealed a mobile hypoechogenic tumorous mass attached to the anterior annulus of the prosthesis. The tumor was successfully treated by surgical excision, and a diagnosis of myxoma was confirmed both clinically and pathologically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spatial variation in the pattern of natural selection can promote local adaptation and genetic differentiation between populations. Because heritable melanin-based ornaments can signal resistance to environmentally mediated elevation in glucocorticoids, to oxidative stress and parasites, populations may vary in the mean degree of melanic coloration if selection on these phenotypic aspects varies geographically. Within a population of Swiss barn owls (Tyto alba), the size of eumelanic spots is positively associated with survival, immunity and resistance to stress, but it is yet unknown whether Tyto species that face stressful environments evolved towards a darker eumelanic plumage. Because selection regimes vary along environmental gradients, we examined whether melanin-based traits vary clinally and are expressed to a larger extent in the tropics where parasites are more abundant than in temperate zones. To this end, we considered 39 barn owl species distributed worldwide. Barn owl species living in the tropics displayed larger eumelanic spots than those found in temperate zones. This was, however, verified in the northern hemisphere only. Parasites being particularly abundant in the tropics, they may promote the evolution of darker eumelanic ornaments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation is an expanding procedure thus far restricted to a target population of old and high-comorbidity patients with symptomatic aortic stenosis. The need for bulky devices (up to 24F) combined with the high prevalence of peripheral vascular disease in these patients explains the increased risk of vascular complications in transfemoral Edwards Sapien (Edwards Lifesciences, Irvine, Calif) transcatheter aortic valve implantation procedures, with a rate of 20% for the transfemoral arm of either the Placement of AoRTic traNscathetER valves in the European Union (PARTNER EU) trial or the SOURCE Registry.1,2

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hip or knee arthroplasty is proposed after osteoarthritis or an accident. It is decided after a long path of pain and decrease in the quality of life. This research explores the period of illness until surgery. Twenty-four semi-structured interviews were conducted one month before surgery and a thematic discourse analysis performed. The diversity and complexity of the patient experience, in a commonly performed surgical intervention underlines important topics, requiring attention in order to improve patient preparations and information prior to arthroplasty: information adapted to individual concerns, needs and representations. Psychological and physical acceptance is necessary for integration of the prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Publicado en la Sección Quiz de la revista.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.