959 resultados para perda de audição
Resumo:
Frontonasal dysplasia (FND) is a rare malformative complex affecting the frontal portion of the face, the eyes and the nose; it may occur singly or associated with other clinical signs. No systematic studies describing hearing in this condition were found. AIM: To evaluate hearing sensitivity and sound stimulus conduction from cochlea to brainstem in patients with clinical signs of FND. METHODS: 21 patients with isolated or syndromic FND were submitted to a clinical (otological/vestibular antecedents and otoscopy) and instrumental (pure tone and speech audiometry, tympanometry and brainstem auditory evoked response) hearing evaluation. DESIGN: A clinical, cross-sectional observational prospective study. RESULTS: Hearing thresholds were normal in 15 (70%) patients, abnormal in 5 (25%), mostly with conductive hearing loss; one patient did not cooperate with testing. The tympanometric curve was type A in 30 (72%) ears, type C in 5 (12%), type As in 4 (9%) and type B in 3 (7%). The auditory brainstem response (ABR) showed no abnormalities. CONCLUSION: Patients with FND showed no abnormalities in the auditory system from cochlea to brainstem in this study. Mild conductive hearing loss found in some is probably related to cleft palate. Further evaluation of hearing pathways at higher levels is recommended.
Resumo:
The purpose of this work was the inlay’s characterization from the water supply networks of Rio Claro-SP city; as well analyze the influence of network’s aging in the actual system. To do this, some samples of inlays were collected and made chemistry analysis and X-Ray Diffraction Spectrometry. The history of the source water quality was also analyzed, to make possible to known the origins of the inlays. To evaluate the performance of the network, some different scenarios have been simulated, varying the resistance coefficient of the water supply networks of Rio Claro-SP. The characterization results showed that there are basically oxide and hydroxide of iron (magnetite and goethite) and quartz in the inlays, which are materials of high hardness. The hydraulic simulations indicated that the simulated scenarios had a variation of ~2000% in terms of loss of energy
Resumo:
This work analyzed the loss of sensible heat from one fluid to be considered homogeneous heat distribution on a thermal reservoir with cylindrical geometries composite insulating layers. We studied two thermal reservoirs with a volume of 20 liters, and the first has a layer thickness of 75 mm of expanding polyurethane foam wrapped in the polycarbonate container and the second container has only layer thickness of 5 mm of polycarbonate, as insulation of fluid of the external environment. The experimental results are compared with theoretical results obtained through a calculation script, displayed and detailed during the work development, from the theory of energy balance. The maximum error introduced between the theoretical and experimental results were 3.5% and 1.4% respectively for the Boilers with or without a polyurethane coating
Resumo:
The teaching of hearing physiology requires an knowledge integration of Human Anatomy, Biophysics, more precisely Bioacoustics and Bioelectrogenesis, as well as Neurophysiology. Students present difficulty to build knowledge about functional mechanisms of sound conduction and sensory transduction, especially if the elements are not visible forms, as the middle and inner ear structures. To make the teaching about hearing physiology and sensory perception easier, was produced a set of didactical materials about the subject. At first, a resin model that faithfully describes the anatomical relationship of the ossicles with the tympanic membrane was developed. Subsequently, a second model that, besides illustrates the mechanism of acoustic impedance overcoming, also reveals how acoustic sensorial transduction occurs in inner ear, was designed and produced. In the third didactical model, are visualized, through students interaction, areas of the cerebral cortex that interpret the different sensory modalities. In addition, were created three educational videos about hearing problems and a site on Human Hearing Physiology, available on Institute of Biosciences website. The results of this course conclusion monograph are presented in the form of articles that were submitted to Journal Physics in the School and the Journal of the Nucleus of Teaching
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of this research is to present a study on a relationship between the local head loss in connection of emitters in pipes with different diameters used in drip irrigation, with the online geometry of the emitter connectors, that allows an easy quantification of such head loss regarding of the size of the connectors. The experiment was carried out according to the Reynolds Numbers at a turbulent flow interval, obtained by the variation of the pipe outflow at a constant temperature of water. The results indicated that the friction factor of the Darcy-Weisbach equation can be estimated by the Blasius equation with the coefficients b = 0.300 and m = 0.25, for the above mentioned pipes. The head losses produced by the connections of the emitters, in relation to the pipe without emitter, was of 62%. A relationship between the kinetic load coefficient (K) and the index of blockage (IO) provoked by the online connector is presented by an algebraic equation which shows a coefficient of adjustment of approximately 96%.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
The aim of this study was to evaluate the mean of alveolar bone loss (%) in radiographies of patients referred to specialist for periodontal treatment. Full mouth series of periapical radiographies (paralelism technique) were used. A total of 9808 proximal surfaces in 4804 teeth of 213 patients (90 males and 123 females), mean age, 44.3 years, were assessed. The alveolar bone loss was measured in relation to root lenght expressed as an average similar to Schei 's technique (1959) without the use of ruler. The references used were the distances cement-enamel juntion (CEJ) - alveolar crest (AC) and CEJ- dental apex taken with a digimatic caliper. The results showed that the mean values of alveolar bone loss (%ABL) was 22.39%. Men showed higher mean values of %ABL than women; the %ABL increased with the age, but the difference among age groups was no statistical significant (p>0.05); the mean values of %ABL of distal surfaces was higher than mesial surfaces (p<0.01), ríght quadrants exhibited higher %ABL values than left quadrants (p<0.01); maxillary sites showed mean values of %ABL higher than mandibular sites; the highest mean values of %ABL was found in molar group, followed by incisor groups, and premolar group; the canine group exhibited lower mean values of %ABL; the differences among the groups was considered statitistically significant (p<0.01). lt was suggested the usage of this technique in the dentistry offices and radiological services for the patient 's documentation and assortment and for later comparison about alveolar bone level
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Introduction: A variety of hypotheses have been proposed to explain the association between temporomandibular disorders and hearing symptoms, including the many anatomical and/or neurological ways, as of a muscle or joint dysfunction, can cause such symptoms. Objective: The purpose of this study is to discuss, through a systematic review of literature, the interrelation between hearing symptoms and temporomandibular disorders. Material and Methods: We consulted the Medline/PubMed, ISI and Scielo in the period 1918 to 2008. The terms related to the research were: “temporomandibular disorders”, “signs and symptoms of temporomandibular disorders”, “otologic symptoms” and “aural symptoms”, where 19 papers were included using the pre-selected criteria for the manufacture of a meta-analysis. Results: According to the findings, the hearing symptoms most often associated with temporomandibular disorders were otalgia and tinnitus, followed by vertigo and hearing loss, respectively. Conclusions: It’s clear the correlation between hearing symptoms and temporomandibular disorders, however there is a need clinical and scientific research more complex to prove the specific cause-effect relationships between them.
Resumo:
One of the complications that concern prosthetists is bone loss peri-implant, because the success of dental implant treatment requires long-term maintenance of hard and soft tissues around the implant. Whereby the dental implants have not only the goal of restoring function, but also the aesthetics of the patient, the bone loss peri-implant can dramatically compromise the aesthetics of rehabilitation, particularly in anterior regions. The aim of this study was to analyze and reason, through literature review, the main factors that can cause bone loss in peri-implant and possible ways to prevent it.
Resumo:
Among the harmful health agents, it is given to the noise, one of the most present in urban and social environments. There are efficient measures to control the noise and the auricular Individual Protection Equipment (IPEa) is the most used. It has been observed the shortage in the comfortable and functional individual auditory protection products, related to durability, face to the efficiency right of the equipment. The main objective of this study was to recognize if there is effectiveness loss toward the used time on the Auditory Equipment, intra-auricular Individual Protection, of foam (3M), model 1110. It has been verified that the equipments suffer efficiency alteration according to the time of use, and the material consuming initiates reliable loss, mainly in audible frequencies going up to 100Hz, and from 16 days for sonorous pressure suffered started in 101dB 20Hz. For sonorous pressure suffered from 107dB to 20Hz, the reliable loss for the usage was of 8 days. The IPEas do not lose effectiveness on important attenuation by the daily use in frequencies from 1KHz until 20KHz. It has been concluded that there is effectiveness loss, according to the daily and frequent use of the IPEa studied.