927 resultados para passive intermodulation
Resumo:
In this paper we present a hybrid technique for correcting distortions that appear when projecting images onto geometrically complex, colored and textured surfaces. It analyzes the optical flow that results from perspective distortions during motions of the observer and tries to use this information for computing the correct image warping. If this fails due to an unreliable optical flow, an accurate -but slower and visiblestructured light projection is automatically triggered. Together with an appropriate radiometric compensation, view-dependent content can be projected onto arbitrary everyday surfaces. An implementation mainly on the GPU ensures fast frame rates.
Resumo:
This paper addresses the problem of service development based on GSM handset signaling. The aim is to achieve this goal without the participation of the users, which requires the use of a passive GSM receiver on the uplink. Since no tool for GSM uplink capturing was available, we developed a new method that can synchronize to multiple mobile devices by simply overhearing traffic between them and the network. Our work includes the implementation of modules for signal recovery, message reconstruction and parsing. The method has been validated against a benchmark solution on GSM downlink and independently evaluated on uplink channels. Initial evaluations show up to 99% success rate in message decoding, which is a very promising result. Moreover, we conducted measurements that reveal insights on the impact of signal power on the capturing performance and investigate possible reactive measures.
Resumo:
In this study, we compared direction detection thresholds of passive self-motion in the dark between artistic gymnasts and controls. Twenty-four professional female artistic gymnasts (ranging from 7 to 20 years) and age-matched controls were seated on a motion platform and asked to discriminate the direction of angular (yaw, pitch, roll) and linear (leftward–rightward) motion. Gymnasts showed lower thresholds for the linear leftward–rightward motion. Interestingly, there was no difference for the angular motions. These results show that the outstanding self-motion abilities in artistic gymnasts are not related to an overall higher sensitivity in self-motion perception. With respect to vestibular processing, our results suggest that gymnastic expertise is exclusively linked to superior interpretation of otolith signals when no change in canal signals is present. In addition, thresholds were overall lower for the older (14–20 years) than for the younger (7–13 years) participants, indicating the maturation of vestibular sensitivity from childhood to adolescence.
Resumo:
Anti-GM1 antibodies are present in some patients with autoimmune neurological disorders. These antibodies are most frequently associated with acute immune neuropathy called Guillain-Barré syndrome (GBS). Some clinical studies associate the presence of these antibodies with poor recovery in GBS. The patients with incomplete recovery have failure of nerve repair, particularly axon regeneration. Our previous work indicates that monoclonal antibodies can inhibit axon regeneration by engaging cell surface gangliosides (Lehmann et al., 2007). We asked whether passive transfer of human anti-GM1 antibodies from patients with GBS modulate axon regeneration in an animal model. Human anti-GM1 antibodies were compared with other GM1 ligands, cholera toxin B subunit and a monoclonal anti-GM1 antibody. Our results show that patient derived anti-GM1 antibodies and cholera toxin beta subunit impair axon regeneration/repair after PNS injury in mice. Comparative studies indicated that the antibody/ligand-mediated inhibition of axon regeneration is dependent on antibody/ligand characteristics such as affinity-avidity and fine specificity. These data indicate that circulating immune effectors such as human autoantibodies, which are exogenous to the nervous system, can modulate axon regeneration/nerve repair in autoimmune neurological disorders such as GBS.
Resumo:
This study deals with indoor positioning using GSM radio, which has the distinct advantage of wide coverage over other wireless technologies. In particular, we focus on passive localization systems that are able to achieve high localization accuracy without any prior knowledge of the indoor environment or the tracking device radio settings. In order to overcome these challenges, newly proposed localization algorithms based on the exploitation of the received signal strength (RSS) are proposed. We explore the effects of non-line-of-sight communication links, opening and closing of doors, and human mobility on RSS measurements and localization accuracy. We have implemented the proposed algorithms on top of software defined radio systems and carried out detailed empirical indoor experiments. The performance results show that the proposed solutions are accurate with average localization errors between 2.4 and 3.2 meters.
Resumo:
Background. WATSU (WaterShiatsu) is a complementary therapeutic treatment method comprising passive stretches and massage techniques administered in 35°C warm water. Pregnant women claim safe methods to reduce pain, stress, and fatigue. Therefore, we conducted a pilot study evaluating the effects of WATSU on pregnancy-related complaints in third trimester pregnant women. Methods. Nine healthy pregnant women at gestational week ≥34 were included in an intervention group (receiving WATSU) and compared to eight women in a passive control group (receiving no treatment). WATSU was performed on days 1 and 4 of the study, accompanied by ultrasound examinations. Outcomes include physiological and psychometric as well as qualitative data. Participants in the control group completed questionnaires only. Results. WATSU was found to significantly lower participants’ levels of stress and pain and to improve their mental health-related quality of life and mood. In comparison to the passive control group, participants in the intervention group reported reduction in perceived stress from day 1 to day 8 (p = 0.036, Cohen’s f = 0.57). Qualitative data indicate that WATSU was appreciated as enjoyable and deeply relaxing. No negative side effects were reported. Conclusion. Our findings support the notion that WATSU yields therapeutic benefits for pregnant women and warrant further research. This study has been registered at ClinicalTrials.gov: NCT01708018.
Resumo:
Acoustic stimulation of the cochlea leads to a travelling wave in the cochlear fluids and on the basilar membrane (BM). It has long been suspected that this travelling wave leads to a steady streaming flow in the cochlea. Theoretical investigations suggested that the steady streaming might be of physiological relevance. Here, we present a quantitative study of the steady streaming in a computational model of a passive cochlea. The structure of the streaming flow is illustrated and the sources of streaming are closely investigated. We describe a source of streaming which has not been considered in the cochlea by previous authors. This source is also related to a steady axial displacement of the BM which leads to a local stretching of this compliant structure. We present theoretical predictions for the streaming intensity which account for these new phenomena. It is shown that these predictions compare well with our numerical results and that there may be steady streaming velocities of the order of millimetres per second. Our results indicate that steady streaming should be more relevant to low-frequency hearing because the strength of the streaming flow rapidly decreases for higher frequencies.
Resumo:
Various assays have been used as an aid to diagnose failure of passive transfer (FPT) of immunoglobulins in neonatal foals, but often lack sensitivity as screening tests, or are time consuming to perform and impractical as confirmatory tests. The aim of the present study was to evaluate whether measurement of serum total globulins (TG; i.e. total protein minus albumin) can be used to estimate the electrophoretic gamma globulin (EGG) fraction in hospitalised neonatal foals with suspected FPT. Sample data from 56 foals were evaluated retrospectively. The coefficient of rank correlation was 0.84. The area under the curve of ROC analysis was 0.887, 0.922 and 0.930 for EGG concentrations <2 g/L, < 4 g/L and <8 g/L, respectively. Cut-offs for TG achieved ≥90% sensitivity for detecting EGG <2 g/L, < 4 g/L and <8 g/L, with negative predictive values of >97% and >94%, using prevalence of 15% and 30%, respectively. These results suggest that measurement of TG can be used as a guide to predicting EGG, provided that appropriate cut-off values are selected, and this technique could be a useful initial screening test for FPT in foals.
Resumo:
BACKGROUND Knee pain is associated with radiographic knee osteoarthritis, but the relationships between physical examination, pain and radiographic features are unclear. OBJECTIVE To examine whether deficits in knee extension or flexion were associated with radiographic severity and pain during clinical examination in persons with knee pain or radiographic features of osteoarthritis. DESIGN Cross-sectional data of the Somerset and Avon Survey of Health (SASH) cohort study. METHODS Participants with knee pain or radiographic features of osteoarthritis were included. We assessed the range of passive knee flexion and extension, pain on movement and Kellgren and Lawrence (K/L) grades. Odds ratios were calculated for the association between range of motion and pain as well as radiographic severity. RESULTS/FINDINGS Of 1117 participants with a clinical assessment, 805 participants and 1530 knees had complete data and were used for this analysis. Pain and radiographic changes were associated with limited range of motion. In knees with pain on passive movement, extension and flexion were reduced per one grade of K/L by -1.4° (95% CI -2.2 to -0.5) and -1.6° (95% CI -2.8 to -0.4), while in knees without pain the reduction was -0.3° (95% CI -0.6 to -0.1) (extension) and -1.1° (-1.8 to -0.3) (flexion). The interaction of pain with K/L was significant (p = 0.021) for extension but not for flexion (p = 0.333). CONCLUSIONS Pain during passive movement, which may be an indicator of reversible soft-tissue changes, e.g., reversible through physical therapy, is independently associated with reduced flexion and extension of the knee.