945 resultados para near-infrared Raman spectroscopy
Resumo:
Raman spectroscopy has been used by fluid inclusionists to: 1) identify and quantitatively determine the relative abundances of gaseous species within fluid inclusions; 2) identify solid phases precipitating from, or accidentally trapped, within fluid inclusions; and 3) determine the detection limits of the C-13/C-12 ratio in the CO2 bearing phase of fluid inclusions.
Resumo:
The aim of this work is to study the influence of several analytical parameters on the variability of Raman spectra of paint samples. In the present study, microtome thin section and direct (no preparation) analysis are considered as sample preparation. In order to evaluate their influence on the measures, an experimental design such as 'fractional full factorial' with seven factors (including the sampling process) is applied, for a total of 32 experiments representing 160 measures. Once the influence of sample preparation highlighted, a depth profile of a paint sample is carried out by changing the focusing plane in order to measure the colored layer under a clearcoat. This is undertaken in order to avoid sample preparation such a microtome sectioning. Finally, chemometric treatments such as principal component analysis are applied to the resulting spectra. The findings of this study indicate the importance of sample preparation, or more specifically, the surface roughness, on the variability of the measurements on a same sample. Moreover, the depth profile experiment highlights the influence of the refractive index of the upper layer (clearcoat) when measuring through a transparent layer.
Resumo:
Background: It is unknown whether cerebral perfusion in geriatric and younger patients under general anaesthesia differs. Methods: We compared 2 groups of patients undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Group 1: 18-40 yrs (n = 20), Group 2: >65 yrs (n = 37). Cerebral perfusion was investigated with transcranial Doppler and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Data are shown as mean } SD. Results: MAP (86 } 9.6 vs 79 } 10.9 mm Hg, p = 0.02), end-tidal concentration of sevoflurane (1.9 } 0.3 vs 1.6 } 0.3%, p <0.01), and the cerebral tissue oxygenation index measured by NIRS (72 } 4 vs 68 } 5%, p = 0.01), were significantly lower in Group 2. The end-tidal concentration of O2 was significantly higher in Group 2 (46 } 4 vs 48 } 4% p = 0.04). There were no significant differences between Group 1 and 2 for cerebral blood flow velocity (41 } 10 vs 43 } 18 cm/s), end tidal CO2 (4.7 } 0.3 vs 4.6 } 0.3 kPa) and cerebrovascular autoregulation (Mx 0.42 } 0.2 vs 0.48 } 0.2). In Group 1 35% and in Group 2 43% of the patients had an index of autoregulation suggesting disturbed cerebrovascular autoregulation (p = n.s.). Conclusions: In elderly patients under general anaesthesia with sevoflurane the cerebral tissue oxygenation index was significantly lower than in younger patients despite higher end-tidal oxygen concentrations. Our data suggest subtle differences in cerebral perfusion between geriatric and younger
Resumo:
This study examined the electromyographic, cerebral and muscle hemodynamic responses during intermittent isometric contractions of biceps brachii at 20, 40, and 60% of maximal voluntary contraction (MVC). Eleven volunteers completed 2 min of intermittent isometric contractions (12/min) at an elbow angle of 90° interspersed with 3 min rest between intensities in systematic order. Surface electromyography (EMG) was recorded from the right biceps brachii and near infrared spectroscopy (NIRS) was used to simultaneously measure left prefrontal and right biceps brachii oxyhemoglobin (HbO2), deoxyhemoglobin (HHb), and total hemoglobin (Hbtot). Transcranial Doppler ultrasound was used to measure middle cerebral artery velocity (MCAv) bilaterally. Finger photoplethysmography was used to record beat-to-beat blood pressure and heart rate. EMG increased with force output from 20 to 60% MVC (P < 0.05). Cerebral HbO2 and Hbtot increased while HHb decreased during contractions with differences observed between 60% vs. 40% and 20% MVC (P < 0.05). Muscle HbO2 decreased while HHb increased during contractions with differences being observed among intensities (P < 0.05). Muscle Hbtot increased from rest at 20% MVC (P < 0.05), while no further change was observed at 40 and 60% MVC (P > 0.05). MCAv increased from rest to exercise but was not different among intensities (P > 0.05). Force output correlated with the root mean square EMG and changes in muscle HbO2 (P < 0.05), but not changes in cerebral HbO2 (P > 0.05) at all three intensities. Force output declined by 8% from the 1st to the 24th contraction only at 60% MVC and was accompanied by systematic increases in RMS, cerebral HbO2 and Hbtot with a leveling off in muscle HbO2 and Hbtot. These changes were independent of alterations in mean arterial pressure. Since cerebral blood flow and oxygenation were elevated at 60% MVC, we attribute the development of fatigue to reduced muscle oxygen availability rather than impaired central neuronal activation.
Resumo:
In this work annealing and growth of CuInS2 thin films is investigated with quasireal-time in situ Raman spectroscopy. During the annealing a shift of the Raman A1 mode towards lower wave numbers with increasing temperature is observed. A linear temperature dependence of the phonon branch of ¿2 cm¿1/100 K is evaluated. The investigation of the growth process (sulfurization of metallic precursors) with high surface sensitivity reveals the occurrence of phases which are not detected with bulk sensitive methods. This allows a detailed insight in the formation of the CuInS2 phases. Independent from stoichiometry and doping of the starting precursors the CuAu ordering of CuInS2 initially forms as the dominating ordering. The transformation of the CuAu ordering into the chalcopyrite one is, in contrast, strongly dependent on the precursor composition and requires high temperatures.
Resumo:
Työn tavoitteena oli tutkia Raman-spektrometrin soveltuvuutta muovipäällystettyjen kartonkien syvyyssuuntaisiin mittauksiin. Lisäksi pyrittiin selvittämään voidaanko kiteisyyttä nähdä Raman-laitteistolla. Työn kirjallisessa osassa on selvitetty Raman-laitteiston teknisiä ominaisuuksia. Kokeellinen osa suoritettiin Lappeenrannan teknillisessä yliopistossa Membraanitekniikan ja teknillisen polymeerikemian laboratoriossa. Työssä käytettiin Horiban Jobin Yvon¿in valmistamaa konfokaalista Raman-spektrometri-laitteistoa (LabRam). Syvyyssuuntaisissa mittauksissa käytettiin apuna motorisoitua x-, y- ja z-suuntaan liikkuvaa tasoa. Mittaukset suoritettiin pistemäisesti tietyllä askelvälillä fokusoimalla näytteen pinnasta sisällepäin. Syvyysprofilointimittaukset aloitettiinmäärittelemällä laitteiston syvyysresoluutio eri konfokaalireikäkoolla. Lisäksityössä tehtiin syvyysprofilointimittauksia sekä läpinäkyvillä monikerrosmuoveilla että muovipäällystetyillä kartongeilla. Työssä mitatut muovipäällysteet sisälsivät pääasiassa polyeteeniä. Tulokset osoittivat, että Raman laitteistolla voidaan havainnoida Raman-aktiiviset ryhmät näytteen eri kerroksista. Lisäksi polyeteenin kiteisyysaste voidaan havaita tietyillä aallonpituuksilla.
Resumo:
Management of neurocritical care patients is focused on the prevention and treatment of secondary brain injury, i.e. the number of pathophysiological intracerebral (edema, ischemia, energy dysfunction, seizures) and systemic (hyperthermia, disorders of glucose homeostasis) events that occur following the initial insult (stroke, hemorrhage, head trauma, brain anoxia) that may aggravate patient outcome. The current therapeutic paradigm is based on multimodal neuromonitoring, including invasive (intracranial pressure, brain oxygen, cerebral microdialysis) and non-invasive (transcranial doppler, near-infrared spectroscopy, EEG) tools that allows targeted individualized management of acute coma in the early phase. The aim of this review is to describe the utility of multimodal neuromonitoring for the critical care management of acute coma.
Resumo:
The objective of industrial crystallization is to obtain a crystalline product which has the desired crystal size distribution, mean crystal size, crystal shape, purity, polymorphic and pseudopolymorphic form. Effective control of the product quality requires an understanding of the thermodynamics of the crystallizing system and the effects of operation parameters on the crystalline product properties. Therefore, obtaining reliable in-line information about crystal properties and supersaturation, which is the driving force of crystallization, would be very advantageous. Advanced techniques, such asRaman spectroscopy, attenuated total reflection Fourier transform infrared (ATR FTIR) spectroscopy, and in-line imaging techniques, offer great potential for obtaining reliable information during crystallization, and thus giving a better understanding of the fundamental mechanisms (nucleation and crystal growth) involved. In the present work, the relative stability of anhydrate and dihydrate carbamazepine in mixed solvents containing water and ethanol were investigated. The kinetics of the solvent mediated phase transformation of the anhydrate to hydrate in the mixed solvents was studied using an in-line Raman immersion probe. The effects of the operation parameters in terms of solvent composition, temperature and the use of certain additives on the phase transformation kineticswere explored. Comparison of the off-line measured solute concentration and the solid-phase composition measured by in-line Raman spectroscopy allowedthe identification of the fundamental processes during the phase transformation. The effects of thermodynamic and kinetic factors on the anhydrate/hydrate phase of carbamazepine crystals during cooling crystallization were also investigated. The effect of certain additives on the batch cooling crystallization of potassium dihydrogen phosphate (KDP) wasinvestigated. The crystal growth rate of a certain crystal face was determined from images taken with an in-line video microscope. An in-line image processing method was developed to characterize the size and shape of thecrystals. An ATR FTIR and a laser reflection particle size analyzer were used to study the effects of cooling modes and seeding parameters onthe final crystal size distribution of an organic compound C15. Based on the obtained results, an operation condition was proposed which gives improved product property in terms of increased mean crystal size and narrowersize distribution.
Resumo:
Near-infrared spectroscopy (NIRS) was used to analyse the crude protein content of dried and milled samples of wheat and to discriminate samples according to their stage of growth. A calibration set of 72 samples from three growth stages of wheat (tillering, heading and harvest) and a validation set of 28 samples was collected for this purpose. Principal components analysis (PCA) of the calibration set discriminated groups of samples according to the growth stage of the wheat. Based on these differences, a classification procedure (SIMCA) showed a very accurate classification of the validation set samples : all of them were successfully classified in each group using this procedure when both the residual and the leverage were used in the classification criteria. Looking only at the residuals all the samples were also correctly classified except one of tillering stage that was assigned to both tillering and heading stages. Finally, the determination of the crude protein content of these samples was considered in two ways: building up a global model for all the growth stages, and building up local models for each stage, separately. The best prediction results for crude protein were obtained using a global model for samples in the two first growth stages (tillering and heading), and using a local model for the harvest stage samples.
Resumo:
PURPOSE: This study aimed to determine the neuro-mechanical and metabolic adjustments in the lower limbs induced by the running anaerobic sprint test (the so-called RAST). METHODS: Eight professional football players performed 6 × 35 m sprints interspersed with 10 s of active recovery on artificial turf with their football shoes. Sprinting mechanics (plantar pressure insoles), root mean square activity of the vastus lateralis (VL), rectus femoris (RF), and biceps femoris (BF) muscles (surface electromyography, EMG) and VL muscle oxygenation (near-infrared spectroscopy) were monitored continuously. RESULTS: Sprint time, contact time and total stride duration increased from the first to the last repetition (+17.4, +20.0 and +16.6 %; all P < 0.05), while flight time and stride length remained constant. Stride frequency (-13.9 %; P < 0.001) and vertical stiffness decreased (-27.2 %; P < 0.001) across trials. Root mean square EMG activities of RF and BF (-18.7 and -18.1 %; P < 0.01 and 0.001, respectively), but not VL (-1.2 %; P > 0.05), decreased over sprint repetitions and were correlated with the increase in running time (r = -0.82 and -0.90; both P < 0.05). Together with a better maintenance of RF and BF muscles activation levels over sprint repetitions, players with a better repeated-sprint performance (lower cumulated times) also displayed faster muscle de- (during sprints) and re-oxygenation (during recovery) rates (r = -0.74 and -0.84; P < 0.05 and 0.01, respectively). CONCLUSION: The repeated anaerobic sprint test leads to substantial alterations in stride mechanics and leg-spring behaviour. Our results also strengthen the link between repeated-sprint ability and the change in neuromuscular activation as well as in muscle de- and re-oxygenation rates.
Resumo:
Tämän työn tarkoituksena on koota yhteen selluprosessin mittausongelmat ja mahdolliset mittaustekniikat ongelmien ratkaisemiseksi. Pääpaino on online-mittaustekniikoissa. Työ koostuu kolmesta osasta. Ensimmäinen osa on kirjallisuustyö, jossa esitellään nykyaikaisen selluprosessin perusmittaukset ja säätötarpeet. Mukana on koko kuitulinja puunkäsittelystä valkaisuun ja kemikaalikierto: haihduttamo, soodakattila, kaustistamo ja meesauuni. Toisessa osassa mittausongelmat ja mahdolliset mittaustekniikat on koottu yhteen ”tiekartaksi”. Tiedot on koottu vierailemalla kolmella suomalaisella sellutehtaalla ja haastattelemalla laitetekniikka- ja mittaustekniikka-asiantuntijoita. Prosessikemian paremmalle ymmärtämiselle näyttää haastattelun perusteella olevan tarvetta, minkä vuoksi konsentraatiomittaukset on valittu jatkotutkimuskohteeksi. Viimeisessä osassa esitellään mahdollisia mittaustekniikoita konsentraatiomittausten ratkaisemiseksi. Valitut tekniikat ovat lähi-infrapunatekniikka (NIR), fourier-muunnosinfrapunatekniikka (FTIR), online-kapillaarielektroforeesi (CE) ja laserindusoitu plasmaemissiospektroskopia (LIPS). Kaikkia tekniikoita voi käyttää online-kytkettyinä prosessikehitystyökaluina. Kehityskustannukset on arvioitu säätöön kytketylle online-laitteelle. Kehityskustannukset vaihtelevat nollasta miestyövuodesta FTIR-tekniikalle viiteen miestyövuoteen CE-laitteelle; kehityskustannukset riippuvat tekniikan kehitysasteesta ja valmiusasteesta tietyn ongelman ratkaisuun. Työn viimeisessä osassa arvioidaan myös yhden mittausongelman – pesuhäviömittauksen – ratkaisemisen teknis-taloudellista kannattavuutta. Ligniinipitoisuus kuvaisi nykyisiä mittauksia paremmin todellista pesuhäviötä. Nykyään mitataan joko natrium- tai COD-pesuhäviötä. Ligniinipitoisuutta voidaan mitata UV-absorptiotekniikalla. Myös CE-laitetta voitaisiin käyttää pesuhäviön mittauksessa ainakin prosessikehitysvaiheessa. Taloudellinen tarkastelu pohjautuu moniin yksinkertaistuksiin ja se ei sovellu suoraan investointipäätösten tueksi. Parempi mittaus- ja säätöjärjestelmä voisi vakauttaa pesemön ajoa. Investointi ajoa vakauttavaan järjestelmään on kannattavaa, jos todellinen ajotilanne on tarpeeksi kaukana kustannusminimistä tai jos pesurin ajo heilahtelee eli pesuhäviön keskihajonta on suuri. 50 000 € maksavalle mittaus- ja säätöjärjestelmälle saadaan alle 0,5 vuoden takaisinmaksuaika epävakaassa ajossa, jos COD-pesuhäviön vaihteluväli on 5,2 – 11,6 kg/odt asetusarvon ollessa 8,4 kg/odt. Laimennuskerroin vaihtelee tällöin välillä 1,7 – 3,6 m3/odt asetusarvon ollessa 2,5 m3/odt.
Resumo:
In recent years, there has been an increased attention towards the composition of feeding fats. In the aftermath of the BSE crisis all animal by-products utilised in animal nutrition have been subjected to close scrutiny. Regulation requires that the material belongs to the category of animal by-products fit for human consumption. This implies the use of reliable techniques in order to insure the safety of products. The feasibility of using rapid and non-destructive methods, to control the composition of feedstuffs on animal fats has been studied. Fourier Transform Raman spectroscopy has been chosen for its advantage to give detailed structural information. Data were treated using chemometric methods as PCA and PLS-DA which have permitted to separate well the different classes of animal fats. The same methodology was applied on fats from various types of feedstock and production technology processes. PLS-DA model for the discrimination of animal fats from the other categories presents a sensitivity and a specificity of 0.958 and 0.914, respectively. These results encourage the use of FT-Raman spectroscopy to discriminate animal fats.
Resumo:
Brain injury is frequently observed after sepsis and may be primarily related to the direct effects of the septic insult on the brain (e.g., brain edema, ischemia, seizures) or to secondary/indirect injuries (e.g., hypotension, hypoxemia, hypocapnia, hyperglycemia). Management of brain injury in septic patients is first focused to exclude structural intracranial complications (e.g., ischemic/hemorrhagic stroke) and possible confounders (e.g., electrolyte alterations or metabolic disorders, such as dysglycemia). Sepsis-associated brain dysfunction is frequently a heterogeneous syndrome. Despite increasing understanding of main pathophysiologic determinants, therapy is essentially limited to protect the brain against further cerebral damage, by way of "simple" therapeutic manipulations of cerebral perfusion and oxygenation and by avoiding over-sedation. Non-invasive monitoring of cerebral perfusion and oxygenation with transcranial Doppler (TCD) and near-infrared spectroscopy (NIRS) is feasible in septic patients. Electroencephalography (EEG) allows detection of sepsis-related seizures and holds promise also as sedation monitoring. Brain CT-scan detects intra-cerebral structural lesions, while magnetic resonance imaging (MRI) provides important insights into primary mechanisms of sepsis-related direct brain injury, (e.g., cytotoxic vs. vasogenic edema) and the development of posterior reversible encephalopathy. Together with EEG and evoked potentials (EP), MRI is also important for coma prognostication. Emerging clinical evidence suggests monitoring of the brain in septic patients can be implemented in the ICU. The objective of this review was to summarize recent clinical data about the role of brain monitoring - including TCD, NIRS, EEG, EP, CT, and MRI - in patients with sepsis and to illustrate its potential utility for the diagnosis, management and prognostication.
Resumo:
This paper presents a preliminary study on the degradation of spray paint samples, illustrated by Optical, FTIR and Raman measurements. As opposed to automotive paints which are specifically designed for improved outdoor exposure and protected using hindered amine light absorbers (HALS) and ultra-violet absorbers (UVA), the spray paints on their side are much simpler in composition and very likely to suffer more from joint effects of solar radiation, temperature and humidity. Six different spray paint were exposed to outdoor UV-radiation for a total period of three months and both FTIR and Raman measurements were taken systematically during this time. These results were later compared to an artificial degradation using a climate chamber. For infrared spectroscopy, degradation curves were plotted using the photo-oxidation index (POI), and could be successfully approximated with a logarithmic fitting (R2 > 0.8). The degradation can appear after the first few days of exposure and be important until 2 months, where it stabilizes and follow a more linear trend afterwards. One advantage is that the degradation products appeared almost exclusively at the far end (∼3000 cm−1) of mid-infrared spectra, and that the fingerprint region of the spectra remained stable over the studied period of time. Raman results suggest that the pigments on the other side, are much more stable and have not shown any sign of degradation over the time of this study. Considering the forensic implications of this environmental degradation, care should be taken when comparing samples if weathering is an option (e.g. an exposed graffiti compared to the paint from a fresh spray paint can). Degradation issues should be kept in mind as they may induce significant differences between paint samples of common origin.