981 resultados para naphtalen acetic acid
Resumo:
The wet oxidation of organic compounds with CO2 and H2O has been demonstrated to be an efficient technique for effluent treatment. This work focuses on the synthesis, characterization and catalytic performance of Fe-MnO2/CeO2, K-MnO2/CeO2/ palygorskite and Fe/ palygorskite toward the wet oxidative degradation of phenol. The experiments were conducted in a sludge bed reactor with controlled temperature, pressure and stirring speed and sampling of the liquid phase. Experiments were performed on the following operating conditions: temperature 130 ° C, pressure 20.4 atm, catalyst mass concentration of 5 g / L initial concentration of phenol and 0.5 g / L. The catalytic tests were performed in a slurry agitated reactor provided with temperature, pressure and agitation control and reactor liquid sampling. The influences of iron loaded on the support (0.3; 7 and 10%, m/m) and the initial pH of the reactant medium (3.1; 6.8; 8.7) were studied. The iron dispersion on the palygorskite, the phase purity and the elemental composition of the catalyst were evaluated by X-Ray Difraction (XRD), Scanning Electron Microscopy (SEM) and X-Ray Flourescence (XRF). The use of palygorskite as support to increase the surface area was confirmed by the B.E.T. surface results. The phenol degradation curves showed that the Fe3+ over palygorskite when compared with the other materials tested has the best performance toward the (Total Organic carbonic) TOC conversion. The decrease in alkalinity of the reaction medium also favors the conversion of TOC. The maximum conversion obtained from the TOC with the catalyst 3% Fe / palygorskite was around 95% for a reaction time of 60 minutes, while reducing the formation of acids, especially acetic acid. With products obtained from wet oxidation of phenol, hydroquinone, p-benzoquinone, catechol and oxalic acid, identified and quantified by High Performance Liquid Chromatography was possible to propose a reaction mechanism of the process where the phenol is transformed into the homogeneous and heterogeneous phase in the other by applying a kinetic model, Langmuir-Hinshelwood type, with evaluation of kinetic constants of different reactions involved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Rationale: Mice exhibit antinociception after a single experience in the elevated plus maze (EPM), an animal model of anxiety. Objective: This study investigated the mechanisms involved in this form of anxiety-induced antinociception. Methods: Nociception was evaluated by means of the writhing test in mice confined either to the open or enclosed arms of the EPM. The effects of systemic (naloxone, midazolam and 8-OH-DPAT) or intra-amygdala (8-OH-DPAT. NAN-190 and midazolam) drug infusions were investigated in mice previously treated i.p. with 0.6% acetic acid, an algic stimulus that induces abdominal contortions. The effects of these drugs on conventional measures of anxiety (% entries and % time in open arms) in a standard EPM test were also independently investigated. Results: Open-arm confinement resulted in a high-magnitude antinociception (minimum 85%, maximum 450%) compared with enclosed arm confinement. The opiate antagonist naloxone (1 mg/kg and 10 mg/kg) neither blocked this open arm-induced antinociception (OAIA) nor modified indices of anxiety in EPM. Administration of midazolam (0.5-2 mg/kg, s.c.) increased OAIA and produced antinociception in enclosed confined animals, as well as attenuating anxiety in the EPM. The 5-HT(1A) receptor agonist 8-OH-DPAT (0.05-1 mg/kg, s.c.) had biphasic effects on OAIA, antagonising the response at the lowest dose and intensifying it at the highest dose. In addition, low doses of this agent reduced anxiety in the EPM. Although bilateral injections of 8-OH-DPAT (5.6 nmol/0.4 mu l) or NAN-190 (5.6 nmol and 10 nmol/0.4 mu l) into the amygdala did not alter OAIA, increased anxiety was observed in the EPM. In contrast, intra-amygdala administration of midazolam (10 nmol and 30 nmol/0.4 mu l) blocked both OAIA and anxiety. Conclusions: These results with systemic and intracerebral drug infusion suggest that 5-HT(1A) receptors localised in the amygdala are not involved in the pain inhibitory processes that are recruited during aversive situations. However, activation of these receptors does phasically increase anxiety. Although the intrinsic antinociceptive properties of systemically administered midazolam confounded interpretation of its effects on OAIA, intra-amygdala injections of this compound suggest that benzodiazepine receptors in this brain region modulate both the antinociceptive and behavioural (anxiety) responses to the EPM.
Resumo:
In this study, water and eight sanitizing solutions (vinegar at 6, 25, and 50%; acetic acid at 2 and 4%; peracetic acid at 80 ppm, sodium hypochlorite at 200 ppm, and sodium dichloroisocyanurate at 200 ppm) were compared in terms of their effectiveness against the natural microbiota of lettuce. All of the samples were kept in contact with the sanitizing solutions for 15 min, and the effectiveness of a sanitizing agent was evaluated on the basis of the number of decimal reductions of the total aerobic mesophilic count, the mold and yeast count, the total coliform count, and the Escherichia coli count. The average initial levels of these organisms in the samples were 6.94 log(10) CFU/g for aerobic mesophilic microorganisms, 5.62 log(10) CFU/g for molds and yeasts, and 3.25 log(10) CFU/g for total coliforms. of 10 samples analyzed, only 4 contained E. coli, and the average initial level of this microorganism in these 4 samples was 1.64 log(10) CFU/g. Salmonella was not detected in any of the samples tested. The decimal reductions of the populations of aerobic mesophilic microorganisms, molds and yeasts, total coliforms, and E. coli were 0.78, 0.87, 0.82, and >0.14 log(10) CFU/g, respectively, in water; 2.89, >3.41, >2.21, and >0.26 log(10) CFU/g, respectively, in 50% vinegar; 2.42, >3.20, >1.99, and >0.26 log(10) CFU/g, respectively, in 25% vinegar; 1.83, 2.57, 1.58, and >0.26 log(10) CFU/g, respectively, in 6% vinegar; 3.91, >3.58, >2.25, and >0.26 log(10) CFU/g, respectively, in 4% acetic acid; 3.37, >3.53, >2.25, and >0.26 log(10) CFU/g, respectively, in 2% acetic acid; 1.85, 2,32, 1.44, and >0.20 log(10) CFU/g, respectively, in 80 ppm of peracetic acid; 2.63, 2.75, 1.91, and >0.26 log(10) CFU/g, respectively, in 200 ppm of sodium hypochlorite; and 3.23, >3.08, >1.95, and >0.26 log(10) CFU/g, respectively, in 200 ppm of sodium dichloroisocyanurate. Statistical analysis of the results showed that the effectiveness levels for all of the sanitizing agents tested were equivalent to or higher than that for sodium hypochlorite at 200 ppm.
Resumo:
A sensitive, precise, and specific high-performance liquid chromatographic (HPLC) method was developed for the assay of gatifloxacin (GATX) in raw material and tablets. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was carried out by reversed-phase chromatography on a C18 absorbosphere column (250 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of acetic acid 50/o--acetonitrile-methanol (70 + 15 + 15, v/v/v) pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 287 nm. The calibration graph for GATX was linear from 4.0 to 14.0 mu g/mL. The interday and intraday precisions (relative standard deviation) were less than 1.05%.
Resumo:
A sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of 1% acetic acid-acetonitrile-methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of the current study was to develop and subsequently validate a simple, sensitive and precise reversed-phase LC method for the determination of ciprofloxacin hydrochloride in ophthalmic solution form. The chromatographic separation of ciprofloxacin hydrochloride was achieved on a Symmetry Waters C(18) column using UV detection at 275 nm. The optimized mobile phase consisted of 2.5% acetic acid solution: methanol:acetonitrile (70:15:15, v/v/v). The proposed method provided linear responses within the concentration range 1.0-6.0 mu g mL(-1) for ciprofloxacin hydrochloride. Correlation coefficient (r) for the ciprofloxacin hydrochloride was 0.9994. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 5% in all instances. No interference from any components of pharmaceutical dosage forms was observed.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)