684 resultados para modifier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of sample preparation strategy of vegetables on the electrothermal behaviour of Se without and with chemical modifiers such as Pd(NO3)(2), Pd(NO3)(2) + Mg(NO3)(2), Pd(NO3)(2) + Cd(NO3)(2), pre-reduced Pd, Mg(NO3)(2), and Ni(NO3)(2) was investigated. Acid digestates and slurries of vegetables (0.1% m/v in 1% m/v HNO3 + 0.005% v/v of Triton X-100) were used to prepare reference solutions or slurries. For 10 mul of each modifier tested, pyrolysis and atomization temperatures were evaluated using pyrolysis and atomization curves, respectively. Best conditions, such as thermal stability, signal profile, repeatability and sensitivity were attained using Pd(NO3)(2) as chemical modifier. The following heating program (temperature, ramp/hold time) of the graphite tube of the Varian SpectrAA-800Z atomic absorption spectrometer was used: dry step (85 degreesC, 5/0 s; 95 degreesC, 40/0 s; 120 degreesC, 10/.5 s); pyrolysis step (1400 degreesC, 10/3s); atomization step (2200 degreesC, 1/2 s); clean step (2600 degreesC, 2/0 s). This pyrolysis temperature is 800 degreesC higher than when measuring without any modifier. For 20 muL sample volume and 10 mug Pd(NO3)(2), analytical curves in the 3.0-30 mug Se 1(-1) range were obtained. The method was applied for Se determination in acid digestates and slurries of 10 vegetable samples and one standard reference material (rice flower) and results were in agreement at 95% confidence level. Recoveries varied from 89 to 95% for spiked samples. The lifetime of the graphite tube was ca. 250 firings and the relative standard deviations (n = 12) for a typical acid digestate and slurry containing 20 mug Se 1(-1) were 3.8% and 8.3%, respectively. The limits of detection were 2.0 mug Se 1(-1) and 0.6 mug Se 1(-1) Se for digestates and slurries, respectively. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method has been developed for the direct and simultaneous determination of As, Cu, Mn, Sb, and Se in drinking water by electrothermal atomic absorption spectrometry (ETAAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect back- ground correction. The thermal behavior of analytes during the pyrolysis and atomization stages was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3 and 1 + 1 (v/v) diluted water using mixtures of Pd(NO3)(2) + Mg(NO3)(2) as the chemical modifier, With 5 mug Pd + 3 mug Mg as the modifier, the pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1400degreesC and 2100degreesC, respectively, and 20 muL of the water sample (sample + 0.28 mol L-1 HNO3, 1 + 1, v/v), dispensed into the graphite tube, analytical curves were established ranging from 5.00 - 50.0 mug L-1 for As, Sb, Se; 10.0 - 100 mug L-1 for Cu; and 20.0 - 200 mug L-1 for Mn. The characteristic masses were around 39 pg As, 17 pg Cu, 60 pg Mn, 43 pg Sb, and 45 pg Se, and the lifetime of the tube was around 500 firings. The limits of detection (LOD) based on integrated absorbance (0.7 mug L-1 As, 0.2 mug L-1 Cu, 0.6 mug L-1 Mn, 0.3 mug L-1 Sb, 0.9 mug L-1 Se) exceeded the requirements of the Brazilian Food Regulations (decree # 310-ANVS from the Health Department), which established the maximum permissible level for As, Cu, Mn, Sb, and Se at 50 mug L-1, 1000 mug L-1, 2000 mug L-1, 5 mug L-1, and 50 mug L-1, respectively. The relative standard deviations (n = 12) were typically < 5.3% for As, < 0.5% for Cu, < 2.1% for Mn, < 11.7% for Sb, and < 9.2% for Se. The recoveries of As, Cu, Mn, Sb, and Se added to the mineral water samples varied from 102-111%, 91-107%, 92-109%, 89-97%, and 101-109%, respectively. Accuracy for the determination of As, Cu, Mu Sb and Se was checked using standard reference materials NIST SRM 1640 - Trace Elements in Natural Water, NIST SRM 1643d - Trace Elements in Water, and 10 mineral water samples. A paired t-test showed that the results were in agreement with the certified values of the standard reference materials at the 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method has been developed for the simultaneous determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by graphite furnace atomic absorption spectrometry (GFAAS) using a transversely heated graphite atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of analytes during the pyrolysis and atomization stages using the mixture Pd(NO3)(2) + Mg(NO3)(2) as the chemical modifier was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3, and diluted ethanol (1 + 1, v/v) containing different nitric acid concentrations. With 5 rhog Pd + 3 mug Mg as the modifiers, pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1200 C and 2200degreesC respectively. For 20 muL of diluted sample (10 muL ethanol + 10 muL of 0.28 mol L-1 HNO3) dispensed into the graphite tube, analytical curves in the 2.0 - 50 mug L-1 Al, As, Cu, Fe, Mn, Ni ranges were established. The calculated characteristic masses were - 37 pg Al, 73 pg As, 31 pg Cu, 16 pg Fe, 9 pg Mn, and 44 pg Ni, and the lifetime of the tube was around 2 50 firings. The limits of detection (LOD) based on integrated absorbance were 1.2 mug L-1 Al, 2.5 mug L-1 As. 0.22 mug L-1 Cu, 1.6 L-1 Fe 0.20 mug L-1 Mn 1.1 mug L-1 Ni. The relatively standard deviations (n = 12) were less than or equal to 3%, less than or equal to 6%, less than or equal to 2%, less than or equal to 3.4%, less than or equal to 1.3%, and less than or equal to 2% for Al, As, Cu, Fe, Mn, and Ni, respectively, the recoveries of Al, As, Cu, Fe, Mn and Ni added to fuel ethanol samples varied from 77% to 112%, 92% to 114%, 104% to 113%, 73% to 116%, 91% to 122% and 93% to 116%, respectively. Accuracy was checked for Al, As, Cu, Fe, Mn, and Ni determination in 20 samples purchased at local gas stations in Araraquara city, Brazil. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained by single-element GFAAS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Iridium-, Ru-, and W-coated platforms were prepared by thermal treatment of the transversely heated graphite atomizer and investigated for the simultaneous determination of As, Bi, Pb, Sb, and Se in tap water by electrothermal atomic absorption spectrometry. The maximum pyrolysis temperature for As and Bi increased in a modifier sequence W < Ru < Ir. For Pb, Sb, and Se, this sequence was W < Ru, It. Calculated characteristic masses in the presence of It, Ru, and W were 35, 33, and 35 pg for As; 63, 51, and 52 pg for Bi; 50, 32, and 34 pg for Pb; 40, 35, and 31 pg for Sb; and 39, 39, and 93 pg for Se, respectively. Ruthenium was elected as the optimum modifier.Repeatability of the measurements was typically < 6%. Recoveries of As, Bi, Pb, Sb, and Se added to tap water samples varied from 79 to 109%. Accuracy was also checked by analysis of five certified reference materials (CRMs) from the National Institute of Standards and Technology (NIST1640 - Trace Elements in Natural Water; NIST 1643d Trace Elements in Water) and High Purity Standards (Trace Metals in Drinking Water Standards, lots #812708, #591107, and #710710). A paired t-test showed that the results for the CRMs were in agreement at the 95% confidence level with the certified values. The graphite tube lifetime was about 650 firings. multi-element determination is particularly challenging due to the necessity of carefully optimizing compromise conditions.Based on the considerations listed above, the aim of this paper was to evaluate the behavior of Ir, Ru, and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se. The performance of the proposed procedure was also verified after the ETAAS analysis of tap waters and reference materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vitreous samples were prepared in the (100 2 x) NaPO3-x WO3 (0 <= x <= 70) glass forming system using conventional melting-quenching methods. The structural evolution of the vitreous network was monitored as a function of composition by thermal analysis, Raman spectroscopy and high resolution one- and two-dimensional P-31 solid state NMR. Addition of WO3 to the NaPO3 glass melt leads to a pronounced increase in the glass transition temperatures, suggesting a significant increase in network connectivity. At the same time Raman spectra indicate that up to about 30 mol% WO3 the tungsten atoms are linked to some non-bridging oxygen atoms (W-O- or W=O bonded species), suggesting that the network modifier sodium oxide is shared to some extent between both network formers. W-O- W bond formation occurs only at WO3 contents exceeding 30 mol%. P-31 magic angle spinning (MAS)-NMR spectra, supported by two-dimensional J-resolved spectroscopy, allow a clear distinction between species having two, one, and zero P-O-P linkages. The possible formation of some anionic tungsten sites suggested from the Raman data implies an average increase in the degree of polymerization for the phosphorus species, which would result in diminished P-31/Na-23 interactions. This prediction is indeed confirmed by P-31{Na-23} and Na-23{P-31} rotational echo double resonance (REDOR) NMR results, which indicate that successive addition of WO3 to NaPO3 glass significantly diminishes the strength of phosphorus-sodium dipole-dipole couplings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this in vitro study was to evaluate the surface and resin-dentine interface characteristics of permanent tooth dentine cut with diamond or carbide burs and treated with phosphoric acid (PA) or an acidic conditioner. Labial surfaces of permanent incisors were prepared into dentine with high-speed carbide or diamond burs and divided into two halves. Phosphoric acid 36% was applied on one half and non-rinse conditioner (NRC) was applied on the other half. Ten randomly selected scanning electron microscopy (SEM) fields from each specimen (n = 15) were evaluated. Occlusal surfaces of third molars were divided in two halves for evaluation of the resin-dentine interface. The halves were randomly assigned to one of each conditioner and restored with Prime & Bond NT/Spectrum. Ten specimens were analysed by SEM to evaluate hybrid layer formation and interfacial seal. We observed that surfaces prepared with carbide bur presented less residual smear plugs (P < 0.05) than surfaces prepared with diamond burs. Surfaces conditioned with NRC, which is a smear layer modifier, presented more residual smear plugs than surfaces conditioned with PA (P < 0.05). Treatment with PA resulted in more sealed interfaces than specimens treated with NRC. Within the limitations of this study the results showed that carbide burs leave a surface that is more conducive to bonding than diamond burs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Binary tellurite-based glasses in the TeO2-PbO system were prepared and its structure investigated by means of Raman Scattering and X-ray Absorption Spectroscopy. Both spectroscopies indicate strong modifications of the first coordination shell around tellurium atoms when the PbO content increases revealing for lead its glassy network modifier role. Also, Pb L-3-edge EXAFS measurements reveal this structural role played by lead atoms, but the presence of a medium range order contribution indicates that lead also participates to the glassy network formation. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A capillary zone electrophoresis method using indirect UV detection for the analysis of chloride and sulfate in alcohol fuel samples was developed. The anions were analyzed in less than 3 min using an electrolyte containing 10 mmol 1(-1) chromate and 0.75 mmol 1(-1) hexamethonium bromide (HMB) as electroosmotic flow modifier. Coefficients of variation were better than 0.6% for migration time (n = 10) and between 2.05 and 2.82% for peak area repeatabilities. Analytical curves of peak area versus concentration in the range of 0.065-0.65 mg kg(-1) for chloride and 0.25-4.0 mg kg(-1) for sulfate were linear with coefficients of correlation higher than 0.9996. The limits of detection for sulfate and chloride were 0.033 and 0.041 mg kg(-1), respectively. Recovery values ranged from 85 to 103%. The method was successfully applied for the quantification of sulfate and chloride in five alcohol fuel samples. The concentration of sulfate varied from 0.45 to 3.12 mg kg(-1). Chloride concentrations were below the method's LOD.