959 resultados para mesh-free method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN]We present advances of the meccano method [1,2] for tetrahedral mesh generation and volumetric parameterization of solids. The method combines several former procedures: a mapping from the meccano boundary to the solid surface, a 3-D local refinement algorithm and a simultaneous mesh untangling and smoothing. The key of the method lies in defining a one-to-one volumetric transformation between the parametric and physical domains. Results with adaptive finite elements will be shown for several engineering problems. In addition, the application of the method to T-spline modelling and isogeometric analysis [3,4] of complex geometries will be introduced…

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN]We have recently introduced a new strategy, based on the meccano method [1, 2], to construct a T-spline parameterization of 2D and 3D geometries for the application of iso geometric analysis [3, 4]. The proposed method only demands a boundary representation of the geometry as input data. The algorithm obtains, as a result, high quality parametric transformation between the objects and the parametric domain, i.e. the meccano. The key of the method lies in de_ning an isomorphic transformation between the parametric and physical T-mesh _nding the optimal position of the interior nodes, once the meccano boundary nodes are mapped to the boundary of the physical domain…

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN]This work introduces a new technique for tetrahedral mesh optimization. The procedure relocates boundary and inner nodes without changing the mesh topology. In order to maintain the boundary approximation while boundary nodes are moved, a local refinement of tetrahedra with faces on the solid boundary is necessary in some cases. New nodes are projected on the boundary by using a surface parameterization. In this work, the proposed method is applied to tetrahedral meshes of genus-zero solids that are generated by the meccano method. In this case, the solid boundary is automatically decomposed into six surface patches which are parameterized into the six faces of a cube with the Floater parameterization...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN]This work presents a novel approach to solve a two dimensional problem by using an adaptive finite element approach. The most common strategy to deal with nested adaptivity is to generate a mesh that represents the geometry and the input parameters correctly, and to refine this mesh locally to obtain the most accurate solution. As opposed to this approach, the authors propose a technique using independent meshes : geometry, input data and the unknowns. Each particular mesh is obtained by a local nested refinement of the same coarse mesh at the parametric space…

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Antibody microarrays are of great research interest because of their potential application as biosensors for high-throughput protein and pathogen screening technologies. In this active area, there is still a need for novel structures and assemblies providing insight in binding interactions such as spherical and annulus-shaped protein structures, e.g. for the utilization of curved surfaces for the enhanced protein-protein interactions and detection of antigens. Therefore, the goal of the presented work was to establish a new technique for the label-free detection of bio-molecules and bacteria on topographically structured surfaces, suitable for antibody binding.rnIn the first part of the presented thesis, the fabrication of monolayers of inverse opals with 10 μm diameter and the immobilization of antibodies on their interior surface is described. For this purpose, several established methods for the linking of antibodies to glass, including Schiff bases, EDC/S-NHS chemistry and the biotin-streptavidin affinity system, were tested. The employed methods included immunofluorescence and image analysis by phase contrast microscopy. It could be shown that these methods were not successful in terms of antibody immobilization and adjacent bacteria binding. Hence, a method based on the application of an active-ester-silane was introduced. It showed promising results but also the need for further analysis. Especially the search for alternative antibodies addressing other antigens on the exterior of bacteria will be sought-after in the future.rnAs a consequence of the ability to control antibody-functionalized surfaces, a new technique employing colloidal templating to yield large scale (~cm2) 2D arrays of antibodies against E. coli K12, eGFP and human integrin αvβ3 on a versatile useful glass surface is presented. The antibodies were swept to reside around the templating microspheres during solution drying, and physisorbed on the glass. After removing the microspheres, the formation of annuli-shaped antibody structures was observed. The preserved antibody structure and functionality is shown by binding the specific antigens and secondary antibodies. The improved detection of specific bacteria from a crude solution compared to conventional “flat” antibody surfaces and the setting up of an integrin-binding platform for targeted recognition and surface interactions of eukaryotic cells is demonstrated. The structures were investigated by atomic force, confocal and fluorescence microscopy. Operational parameters like drying time, temperature, humidity and surfactants were optimized to obtain a stable antibody structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The objective of this study was to link expression patterns of B-cell-specific Moloney murine leukemia virus integration site 1 (Bmi-1) and p16 to patient outcome (recurrence and survival) in a cohort of 252 patients with oral and oropharyngeal squamous cell cancer (OSCC). METHODS: Expression levels of Bmi-1 and p16 in samples from 252 patients with OSCC were evaluated immunohistochemically using the tissue microarray method. Staining intensity was determined by calculating an intensity reactivity score (IRS). Staining intensity and the localization of expression within tumor cells (nuclear or cytoplasmic) were correlated with overall, disease-specific, and recurrence-free survival. RESULTS: The majority of cancers were localized in the oropharynx (61.1%). In univariate analysis, patients who had OSCC and strong Bmi-1 expression (IRS >10) had worse outcomes compared with patients who had low and moderate Bmi-1 expression (P = .008; hazard ratio [HR], 1.82; 95% confidence interval [CI], 1.167-2.838); this correlation was also observed for atypical cytoplasmic Bmi-1 expression (P = .001; HR, 2.164; 95% CI, 1.389-3.371) and for negative p16 expression (P < .001; HR, 0.292; 95% CI, 0.178-0.477). The combination of both markers, as anticipated, had an even stronger correlation with overall survival (P < .001; HR, 8.485; 95% CI, 4.237-16.994). Multivariate analysis demonstrated significant results for patients with oropharyngeal cancers, but not for patients with oral cavity tumors: Tumor classification (P = .011; HR, 1.838; 95%CI, 1.146-2.947) and the combined marker expression patterns (P < .001; HR, 6.254; 95% CI, 2.869-13.635) were correlated with overall survival, disease-specific survival (tumor classification: P = .002; HR, 2.807; 95% CI, 1.477-5.334; combined markers: P = .002; HR, 5.386; 95% CI, 1.850-15.679), and the combined markers also were correlated with recurrence-free survival (P = .001; HR, 8.943; 95% CI, 2.562-31.220). CONCLUSIONS: Cytoplasmic Bmi-1 expression, an absence of p16 expression, and especially the combination of those 2 predictive markers were correlated negatively with disease-specific and recurrence-free survival in patients with oropharyngeal cancer. Therefore, the current results indicate that these may be applicable as predictive markers in combination with other factors to select patients for more aggressive treatment and follow-up. Cancer 2011;. © 2011 American Cancer Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new approach for the determination of free and total valproic acid in small samples of 140 μL human plasma based on capillary electrophoresis with contactless conductivity detection is proposed. A dispersive liquid-liquid microextraction technique was employed in order to remove biological matrices prior to instrumental analysis. The free valproic acid was determined by isolating free valproic acid from protein-bound valproic acid by ultrafiltration under centrifugation of 100 μL sample. The filtrate was acidified to turn valproic acid into its protonated neutral form and then extracted. The determination of total valproic acid was carried out by acidifying 40 μL untreated plasma to release the protein-bound valproic acid prior to extraction. A solution consisting of 10 mM histidine, 10 mM 3-(N-morpholino)propanesulfonic acid and 10 μM hexadecyltrimethylammonium bromide of pH 6.5 was used as background electrolyte for the electrophoretic separation. The method showed good linearity in the range of 0.4-300 μg/mL with a correlation coefficient of 0.9996. The limit of detection was 0.08 μg/mL, and the reproducibility of the peak area was excellent (RSD=0.7-3.5%, n=3, for the concentration range from 1 to 150 μg/mL). The results for the free and total valproic acid concentration in human plasma were found to be comparable to those obtained with a standard immunoassay. The corresponding correlation coefficients were 0.9847 for free and 0.9521 for total valproic acid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The final goal of mandibular reconstruction following ablative surgery for oral cancer is often considered to be dental implant-supported oral rehabilitation, for which bone grafts should ideally be placed in a suitable position taking subsequent prosthetic restoration into account. The aim of this study was to evaluate the efficacy of a standardized treatment strategy for mandibular reconstruction according to the size of the bony defect and planned subsequent dental prosthetic rehabilitation. Data of 56 patients, who had undergone such a systematic mandibular fibula free flap reconstruction, were retrospectively analyzed. Early complications were observed in 41.5% of the patients but only in those who had been irradiated. Late complications were found in 38.2%. Dental implant survival rate was 92%, and dental prosthetic treatment has been completed in all classes of bony defects with an overall success rate of 42.9%. The main reasons for failure of the complete dental reconstruction were patients' poor cooperation (30.4%) and tumour recurrence (14.3%) followed by surgery-related factors (10.8%) such as implant failure and an unfavourable intermaxillary relationship between the maxilla and the mandible. A comparison of our results with the literature findings revealed no marked differences in the complication rates and implant survival rates. However, a systematic concept for the reconstructive treatment like the method presented here, plays an important role in the successful completion of dental reconstruction. The success rate could still be improved by some technical progress in implant and bone graft positioning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A free-space optical (FSO) laser communication system with perfect fast-tracking experiences random power fading due to atmospheric turbulence. For a FSO communication system without fast-tracking or with imperfect fast-tracking, the fading probability density function (pdf) is also affected by the pointing error. In this thesis, the overall fading pdfs of FSO communication system with pointing errors are calculated using an analytical method based on the fast-tracked on-axis and off-axis fading pdfs and the fast-tracked beam profile of a turbulence channel. The overall fading pdf is firstly studied for the FSO communication system with collimated laser beam. Large-scale numerical wave-optics simulations are performed to verify the analytically calculated fading pdf with collimated beam under various turbulence channels and pointing errors. The calculated overall fading pdfs are almost identical to the directly simulated fading pdfs. The calculated overall fading pdfs are also compared with the gamma-gamma (GG) and the log-normal (LN) fading pdf models. They fit better than both the GG and LN fading pdf models under different receiver aperture sizes in all the studied cases. Further, the analytical method is expanded to the FSO communication system with beam diverging angle case. It is shown that the gamma pdf model is still valid for the fast-tracked on-axis and off-axis fading pdfs with point-like receiver aperture when the laser beam is propagated with beam diverging angle. Large-scale numerical wave-optics simulations prove that the analytically calculated fading pdfs perfectly fit the overall fading pdfs for both focused and diverged beam cases. The influence of the fast-tracked on-axis and off-axis fading pdfs, the fast-tracked beam profile, and the pointing error on the overall fading pdf is also discussed. At last, the analytical method is compared with the previous heuristic fading pdf models proposed since 1970s. Although some of previously proposed fading pdf models provide close fit to the experiment and simulation data, these close fits only exist under particular conditions. Only analytical method shows accurate fit to the directly simulated fading pdfs under different turbulence strength, propagation distances, receiver aperture sizes and pointing errors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The report reviews the technology of Free-space Optical Communication (FSO) and simulation methods for testing the performance of diverged beam in the technology. In addition to the introduction, the theory of turbulence and its effect over laser is also reviewed. In the simulation revision chapter, on-off keying (OOK) and diverged beam is assumed in the transmitter, and in the receiver, avalanche photodiode (APD) is utilized to convert the photon stream into electron stream. Phase screens are adopted to simulate the effect of turbulence over the phase of the optical beam. Apart from this, the method of data processing is introduced and retrospected. In the summary chapter, there is a general explanation of different beam divergence and their performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Turbulence affects traditional free space optical communication by causing speckle to appear in the received beam profile. This occurs due to changes in the refractive index of the atmosphere that are caused by fluctuations in temperature and pressure, resulting in an inhomogeneous medium. The Gaussian-Schell model of partial coherence has been suggested as a means of mitigating these atmospheric inhomogeneities on the transmission side. This dissertation analyzed the Gaussian-Schell model of partial coherence by verifying the Gaussian-Schell model in the far-field, investigated the number of independent phase control screens necessary to approach the ideal Gaussian-Schell model, and showed experimentally that the Gaussian-Schell model of partial coherence is achievable in the far-field using a liquid crystal spatial light modulator. A method for optimizing the statistical properties of the Gaussian-Schell model was developed to maximize the coherence of the field while ensuring that it does not exhibit the same statistics as a fully coherent source. Finally a technique to estimate the minimum spatial resolution necessary in a spatial light modulator was developed to effectively propagate the Gaussian-Schell model through a range of atmospheric turbulence strengths. This work showed that regardless of turbulence strength or receiver aperture, transmitting the Gaussian-Schell model of partial coherence instead of a fully coherent source will yield a reduction in the intensity fluctuations of the received field. By measuring the variance of the intensity fluctuations and the received mean, it is shown through the scintillation index that using the Gaussian-Schell model of partial coherence is a simple and straight forward method to mitigate atmospheric turbulence instead of traditional adaptive optics in free space optical communications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Determining how an exhaust system will perform acoustically before a prototype muffler is built can save the designer both a substantial amount of time and resources. In order to effectively use the simulation tools available it is important to understand what is the most effective tool for the intended purpose of analysis as well as how typical elements in an exhaust system affect muffler performance. An in-depth look at the available tools and their most beneficial uses are presented in this thesis. A full parametric study was conducted using the FEM method for typical muffler elements which was also correlated to experimental results. This thesis lays out the overall ground work on how to accurately predict sound pressure levels in the free field for an exhaust system with the engine properties included. The accuracy of the model is heavily dependent on the correct temperature profile of the model in addition to the accuracy of the source properties. These factors will be discussed in detail and methods for determining them will be presented. The secondary effects of mean flow, which affects both the acoustical wave propagation and the flow noise generation, will be discussed. Effective ways for predicting these secondary effects will be described. Experimental models will be tested on a flow rig that showcases these phenomena.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To report our experience with the successful removal of visible tension-free vaginal tape (TVT) by standard transurethral electroresection, as intravesical tape erosion after TVT is a rare complication, and removal can be challenging, with few cases reported. PATIENTS AND METHODS: Five patients presenting with TVT erosion into the bladder were treated at our institutions from December 2004 to July 2007; all had standard transurethral electroresection. Their records were reviewed retrospectively to retrieve data on presenting symptoms, diagnostic tests, surgical procedures and outcomes. RESULTS: The median (range) interval between the TVT procedure and the onset of symptoms was 17 (1-32) months. The predominant symptoms were painful micturition, recurrent urinary tract infection (UTI), urgency and urge incontinence. There were no complications during surgery. The storage symptoms and UTI resolved completely after removing the eroded mesh in all but one patient. Cystoscopy at 1 month after surgery showed complete healing of the bladder mucosa. CONCLUSION: Although TVT erosion into the bladder is rare, persistent symptoms, particularly recurrent UTIs, must raise some suspicion for this condition. Standard transurethral electroresection seems to be a safe, simple, minimally invasive and successful treatment option for TVT removal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The coverage of recurrent pressure sores with unstable scar in the surrounding tissue is still an unsolved problem in the literature. Local and regional transfer of tissue often does not meet the requirements of the tissue deficit. Especially in recurrent pressure sores, the adjacent skin has already been consumed due to multiple surgeries. As a good alternative, the microsurgical transfer of flaps offers viable tissue to cover even large pressure sores. METHODS: We performed a total of six free flaps in five patients who suffered from intractable pressure sores in the hip region. The age of the patients was between 41 and 63 years. The defect size varied between 6 x 6 cm and 25 x 30 cm. Two combined myocutaneous scapula-latissimus dorsi, two myocutaneous latissimus dorsi, one anteromedial thigh, and one rectus femoris flap were used to cover the defects. RESULTS: The average follow-up time was 29 months. Flaps provided stable coverage in four of five patients at 12-month follow-up. There was one subtotal flap necrosis that was subsequently treated with split-thickness skin grafting. CONCLUSION: In this series of five patients with six free flaps, we were able to show that the microsurgical transfer of tissue is a valuable option in the treatment of difficult pressure sores. Even in older and debilitated patients, this method is a good alternative to conventional local flaps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A metallic filter effectively removes vapor from gas streams. The filter captures the mercury which then can be released and collected as a product. The metallic filter is a copper mesh sponge plated with a six micrometer thickness of gold. The filter removes up to 90% of mercury vapor from a mercury contaminated gas stream.