904 resultados para frame beam
Resumo:
Cone beam computed tomography (CBCT) can be considered as a valuable imaging modality for improving diagnosis and treatment planning to achieve true guidance for several craniofacial surgical interventions. A new concept and perspective in medical informatics is the highlight discussion about the new imaging interactive workflow. The aim of this article was to present, in a short literature review, the usefulness of CBCT technology as an important alternative imaging modality, highlighting current practices and near-term future applications in cutting-edge thought-provoking perspectives for craniofacial surgical assessment. This article explains the state of the art of CBCT improvements, medical workstation, and perspectives of the dedicated unique hardware and software, which can be used from the CBCT source. In conclusion, CBCT technology is developing rapidly, and many advances are on the horizon. Further progress in medical workstations, engineering capabilities, and improvement in independent software-some open source-should be attempted with this new imaging method. The perspectives, challenges, and pitfalls in CBCT will be delineated and evaluated along with the technological developments.
Resumo:
Background: Owing to a lack of symptoms and difficult visualization in routine intraoral radiographs, diagnosis of external root resorptions can be challenging. Aim: The goal of this study was to compare two image acquisition methods, intraoral radiographs and cone beam computed tomography (CBCT), in the diagnosis of external resorption. Material and Methods: Thirty-four maxillary and mandibular bicuspids were divided into three groups. Perforations measuring 0.3 and 0.6 mm in diameter and 0.15 and 0.3 mm in depth, respectively, were made on the lingual root surfaces in thirty teeth, and four were used as controls. Next, teeth were mounted on an apparatus and radiographed at mesial, distal, and orthoradial angulations. CBCT images were also taken. The analysis of the intraoral radiographic and tomographic images was carried out by two experts using standardized scores. Data were then compared statistically. Results: A strong agreement between the examiners was observed in both diagnosis methods, the intraoral radiographic (r = 0.93) and the tomographic analysis (r = 1.0). Tomography had higher statistically significant detection values than intraoral radiography (P < 0.05). In intraoral radiographs, the detection was significantly greater (P < 0.05) in the mandibular bicuspids, compared with their maxillary counterparts. The ability to detect 0.6-mm perforations by intraoral radiography was significantly higher than that of 0.3-mm perforations (P < 0.05). Conclusion: Cone beam computed tomography showed better diagnostic ability compared with intraoral radiography, regardless of the tooth or the dimensions of the resorption evaluated.
Resumo:
The present article discusses an atrophic maxilla reconstruction with iliac crest bone block and particulate grafts and dental implants. Onlay block grafts were used to restore bone volume of the anterior maxilla, whereas bilateral sinus floor augmentation was performed using a particulate graft. Ten months after the grafting surgery, 9 dental implants were placed to rehabilitate the case. Results of a 7-year follow-up were obtained clinically and by cone beam computed tomographic images.
Resumo:
A semi-autonomous unmanned underwater vehicle (UUV), named LAURS, is being developed at the Laboratory of Sensors and Actuators at the University of Sao Paulo. The vehicle has been designed to provide inspection and intervention capabilities in specific missions of deep water oil fields. In this work, a method of modeling and identification of yaw motion dynamic system model of an open-frame underwater vehicle is presented. Using an on-board low cost magnetic compass sensor the method is based on the utilization of an uncoupled 1-DOF (degree of freedom) dynamic system equation and the application of the integral method which is the classical least squares algorithm applied to the integral form of the dynamic system equations. Experimental trials with the actual vehicle have been performed in a test tank and diving pool. During these experiments, thrusters responsible for yaw motion are driven by sinusoidal voltage signal profiles. An assessment of the feasibility of the method reveals that estimated dynamic system models are more reliable when considering slow and small sinusoidal voltage signal profiles, i.e. with larger periods and with relatively small amplitude and offset.
Resumo:
The yrast level structure of Rn-215 has been studied by means of in-beam spectroscopy alpha-gamma-gamma coincidence techniques through the Pb-207(O-18,2 alpha 2n) reaction at 93 MeV bombarding energy, using the 8 pi GASP-ISIS spectrometer at Legnaro. New spectroscopic information has been obtained. The deduced low-lying level scheme of Rn-215 does not exhibit the alternating parity structure observed in the heavier known isotones Fr-216, Ra-217, Ac-218, and Th-219. From this result, the lightest nucleus showing evidence for octupole collectivity is Fr-216, defining the lowest-mass corner for this kind of phenomenon as N >= 129 and Z >= 87.
Resumo:
Objective: Cone-beam computed tomography (CBCT) is a reliable method of assessing the oral cavity and upper airways. We conducted this study to examine the changes introduced by rapid maxillary expansion in the nasal cavity, nasopharynx, and oropharynx as seen with images obtained by CBCT. Materials and Methods: We evaluated 15 patients with maxillary width deficiency treated with RME. Patients were subjected to CBCT at the beginning of RME and after the retention period of 4 months. Results: The nasal cavity presented a significant transverse increase in the lower third, in the anterior (1.08 mm +/- 0.15), medium (1.28 mm +/- 0.15), and posterior regions (0.77 mm +/- 0.12). No significant change occurred in the nasopharynx in volume (P = .11), median sagittal area (P = .33), or lower axial area (P = .29) resulting from the RME. A significant change was noted in the oropharynx in volume (P = .05), median sagittal area (P = .01), and lower axial area (P = .04) before and immediately after the RME. Conclusions: RME is able to increase the transverse width of the nasal cavity, but it does not have the same effect in the nasopharynx. Changes noted in the oropharynx may be due to the lack of a standardized position of the head and tongue at the time of image acquisition. (Angle Orthod. 2012;82:458-463.)
Resumo:
Objectives: To verify the thickness and level of alveolar bone around the teeth adjacent to the cleft by means of cone beam computed tomography (CBCT) in patients with complete bilateral cleft lip and palate prior to bone graft surgery and orthodontic intervention. Method: The sample comprised 10 patients with complete bilateral cleft lip and palate (five boys and five girls) in the mixed dentition. The mean age was 9.5 years, and all subjects showed a G3 interarch relationship according to the Bauru index. The thickness of alveolar bone surrounding the maxillary incisors and the maxillary canines was measured in CBCT axial section using the software iCAT Xoran System. The distance between the alveolar bone crest and the cement-enamel junction (CEJ) was measured in cross sections. Results: The tomography images showed a thin alveolar bone plate around teeth adjacent to clefts. No bone dehiscence was observed in teeth adjacent to clefts during the mixed dentition. A slight increase in the distance between the alveolar bone crest and the CEJ was observed in the mesial and lingual aspects of canines adjacent to cleft. Conclusion: In patients with BCLP in the mixed dentition, teeth adjacent to the alveolar cleft are covered by a thin alveolar bone plate. However, the level of alveolar bone crest around these teeth seems to be normal, and no bone dehiscence was identified at this age.
Resumo:
Background: Translational errors can result in bypassing of the main viral protein reading frames and the production of alternate reading frame (ARF) or cryptic peptides. Within HIV, there are many such ARFs in both sense and the antisense directions of transcription. These ARFs have the potential to generate immunogenic peptides called cryptic epitopes (CE). Both antiretroviral drug therapy and the immune system exert a mutational pressure on HIV-1. Immune pressure exerted by ARF CD8(+) T cells on the virus has already been observed in vitro. HAART has also been described to select HIV-1 variants for drug escape mutations. Since the mutational pressure exerted on one location of the HIV-1 genome can potentially affect the 3 reading frames, we hypothesized that ARF responses would be affected by this drug pressure in vivo. Methodology/Principal findings: In this study we identified new ARFs derived from sense and antisense transcription of HIV-1. Many of these ARFs are detectable in circulating viral proteins. They are predominantly found in the HIV-1 env nucleotide region. We measured T cell responses to 199 HIV-1 CE encoded within 13 sense and 34 antisense HIV-1 ARFs. We were able to observe that these ARF responses are more frequent and of greater magnitude in chronically infected individuals compared to acutely infected patients, and in patients on HAART, the breadth of ARF responses increased. Conclusions/Significance: These results have implications for vaccine design and unveil the existence of potential new epitopes that could be included as vaccine targets.
Resumo:
Abstract Background The ongoing efforts to sequence the honey bee genome require additional initiatives to define its transcriptome. Towards this end, we employed the Open Reading frame ESTs (ORESTES) strategy to generate profiles for the life cycle of Apis mellifera workers. Results Of the 5,021 ORESTES, 35.2% matched with previously deposited Apis ESTs. The analysis of the remaining sequences defined a set of putative orthologs whose majority had their best-match hits with Anopheles and Drosophila genes. CAP3 assembly of the Apis ORESTES with the already existing 15,500 Apis ESTs generated 3,408 contigs. BLASTX comparison of these contigs with protein sets of organisms representing distinct phylogenetic clades revealed a total of 1,629 contigs that Apis mellifera shares with different taxa. Most (41%) represent genes that are in common to all taxa, another 21% are shared between metazoans (Bilateria), and 16% are shared only within the Insecta clade. A set of 23 putative genes presented a best match with human genes, many of which encode factors related to cell signaling/signal transduction. 1,779 contigs (52%) did not match any known sequence. Applying a correction factor deduced from a parallel analysis performed with Drosophila melanogaster ORESTES, we estimate that approximately half of these no-match ESTs contigs (22%) should represent Apis-specific genes. Conclusions The versatile and cost-efficient ORESTES approach produced minilibraries for honey bee life cycle stages. Such information on central gene regions contributes to genome annotation and also lends itself to cross-transcriptome comparisons to reveal evolutionary trends in insect genomes.
Resumo:
Objectives The aim of this study was to determine the prevalence of apical periodontitis (AP) detected in cone beam CT (CBCT) images from a database. Methods CBCT images of 300 Brazilian patients were assessed. AP images were measured in three dimensions. Age, gender, number and location of total teeth in each patient were considered. AP location was considered according to tooth groups. The extent of AP was determined by the largest diameter in any of the three dimensions. Percentages and the X2 test were used for statistical analysis. Results AP was found in 51.4% of the patients and in 3.4% of the teeth. Higher prevalence of AP was found in 60- to 69-year-olds (73.1%) and in mandibular molars (5.9%) (p < 0.05). Inadequate endodontic treatment presented higher prevalence of AP (78.1%). Conclusions AP can be frequently found in CBCT examinations. The presence of AP has a significant association with patients' age, and tooth type and condition. CBCT databases are useful for cross-sectional studies about AP prevalence in a population.
Resumo:
Introduction: This study aimed to evaluate the close proximity established between the maxillary sinus floor and posterior teeth roots apices by using cone-beam computed tomographic scanning. Methods: The relationship of maxillary sinuses and posterior teeth roots, which were divided into 2 groups, was analyzed using i-CAT Vision software (Imaging Sciences, Hatfield, PA). Group 1 included all root apices found in close contact with the maxillary sinus floor without sinus floor elevation, whereas group 2 included all root apices that were protruded within the sinus producing an elevation of the bony cortical. Results: A total of 100 maxillary sinuses and 601 roots apices were evaluated. Group 1 presented 130 of 601 (21.6%) roots and group 2 presented 86 of 601 (14.3%) roots. Conclusions: The second molar mesiobuccal root apex is frequently found in close proximity with the sinus floor, and the relation between these anatomic structures should be considered in order to prevent an iatrogenic procedure and minimize the risks from an infectious disease within the sinus
Resumo:
Brazilian design code ABNT NBR6118:2003 - Design of Concrete Structures - Procedures - [1] proposes the use of simplified models for the consideration of non-linear material behavior in the evaluation of horizontal displacements in buildings. These models penalize stiffness of columns and beams, representing the effects of concrete cracking and avoiding costly physical non-linear analyses. The objectives of the present paper are to investigate the accuracy and uncertainty of these simplified models, as well as to evaluate the reliabilities of structures designed following ABNT NBR6118:2003[1&] in the service limit state for horizontal displacements. Model error statistics are obtained from 42 representative plane frames. The reliabilities of three typical (4, 8 and 12 floor) buildings are evaluated, using the simplified models and a rigorous, physical and geometrical non-linear analysis. Results show that the 70/70 (column/beam stiffness reduction) model is more accurate and less conservative than the 80/40 model. Results also show that ABNT NBR6118:2003 [1] design criteria for horizontal displacement limit states (masonry damage according to ACI 435.3R-68(1984) [10]) are conservative, and result in reliability indexes which are larger than those recommended in EUROCODE [2] for irreversible service limit states.
Resumo:
Reinforced concrete beam elements are submitted to applicable loads along their life cycle that cause shear and torsion. These elements may be subject to only shear, pure torsion or both, torsion and shear combined. The Brazilian Standard Code ABNT NBR 6118:2007 [1] fixes conditions to calculate the transverse reinforcement area in beam reinforced concrete elements, using two design models, based on the strut and tie analogy model, first studied by Mörsch [2]. The strut angle θ (theta) can be considered constant and equal to 45º (Model I), or varying between 30º and 45º (Model II). In the case of transversal ties (stirrups), the variation of angle α (alpha) is between 45º and 90º. When the equilibrium torsion is required, a resistant model based on space truss with hollow section is considered. The space truss admits an inclination angle θ between 30º and 45º, in accordance with beam elements subjected to shear. This paper presents a theoretical study of models I and II for combined shear and torsion, in which ranges the geometry and intensity of action in reinforced concrete beams, aimed to verify the consumption of transverse reinforcement in accordance with the calculation model adopted As the strut angle on model II ranges from 30º to 45º, transverse reinforcement area (Asw) decreases, and total reinforcement area, which includes longitudinal torsion reinforcement (Asℓ), increases. It appears that, when considering model II with strut angle above 40º, under shear only, transverse reinforcement area increases 22% compared to values obtained using model I.
Resumo:
Objetivo: Dente Duplo (“double tooth”) é uma anomalia de forma que ocorre pela fusão de dois ou mais dentes ou geminação de um único dente, geralmente durante a fase de morfodiferenciação do germe dentário. A incidência de dente duplo varia 0,14-5,0% da população mundial, sem predileção pelo gênero. Apresentação unilateral é mais comum do que a bilateral. No geral, as anomalias dentarias em pacientes com fissura labiopalatina ocorrem próximas à região da fissura. O objetivo deste trabalho é relatar o tratamento endodôntico não cirúrgico de um caso de dentes duplos em um paciente com fissura labiopalatina. Relato de Caso: Paciente de gênero feminino de 10 anos com fissura labiopalatina matriculado no Hospital de Reabilitação de Anomalias Craniofaciais (HRAC-USP), encaminhado ao setor de Endodontia do HRAC-USP para realizar o tratamento endodôntico dos dentes 11 e 12 para ser re-anatomizados. Pela superposição dos dentes 11, 12, e presença de uma cúspide acessória (“talon cusp”) além de um dente supranumerário, as radiografia panorâmica e a radiografia periapical não mostram claramente a anatomia externa do dente e a interna dos condutos radiculares, motivo pelo qual foi solicitada uma tomografia computadorizada Cone-Beam para determinar o comprimento de trabalho para preparo biomecânico e obturação dos condutos radiculares. Serão apresentadas as etapas de diagnóstico e tratamento realizados no caso. Conclusão: Pela morfologia anormal da coroa e complexidade dos canais radiculares, o tratamento endodôntico apresentaria dificuldades, por isso o exame clínico e radiográfico cuidadoso é essencial para o sucesso do tratamento endodôntico. Desta forma concluise que a imagem fornecida pela tomografia computadorizada Cone-Beam foi útil no planejamento e tratamento deste caso.
Resumo:
Diffusion is a common phenomenon in nature and generally is associated with a system trying to reach a local or a global equilibrium state, as a result of highly irregular individual particle motion. Therefore it is of fundamental importance in physics, chemistry and biology. Particle tracking in complex fluids can reveal important characteristics of its properties. In living cells, we coat the microbead with a peptide (RGD) that binds to integrin receptors at the plasma membrane, which connects to the CSK. This procedure is based on the hypothesis that the microsphere can move only if the structure where it is attached move as well. Then, the observed trajectory of microbeads is a probe of the cytoskeleton (CSK), which is governed by several factors, including thermal diffusion, pressure gradients, and molecular motors. The possibility of separating the trajectories into passive and active diffusion may give information about the viscoelasticity of the cell structure and molecular motors activity. And also we could analyze the motion via generalized Stokes-Einstein relation, avoiding the use of any active techniques. Usually a 12 to 16 Frames Per Second (FPS) system is used to track the microbeads in cell for about 5 minutes. Several factors make this FPS limitation: camera computer communication, light, computer speed for online analysis among others. Here we used a high quality camera and our own software, developed in C++ and Linux, to reach high FPS. Measurements were conducted with samples for 10£ and 20£ objectives. We performed sequentially images with different intervals, all with 2 ¹s exposure. The sequences of intervals are in milliseconds: 4 5 ms (maximum speed) 14, 25, 50 and 100 FPS. Our preliminary results highlight the difference between passive and active diffusion, since the passive diffusion is represented by a Gaussian in the distribution of displacements of the center of mass of individual beads between consecutive frames. However, the active process, or anomalous diffusion, shows as long tails in the distribution of displacements.