860 resultados para electronic configuration
Resumo:
One fundamental question about pulsars concerns the mechanism of their pulsed electromagnetic emission. Measuring the high-end region of a pulsar's spectrum would shed light on this question. By developing a new electronic trigger, we lowered the threshold of the Major Atmospheric γ-ray Imaging Cherenkov (MAGIC) telescope to 25 giga-electron volts. In this configuration, we detected pulsed γ-rays from the Crab pulsar that were greater than 25 giga-electron volts, revealing a relatively high cutoff energy in the phase-averaged spectrum. This indicates that the emission occurs far out in the magnetosphere, hence excluding the polar-cap scenario as a possible explanation of our measurement. The high cutoff energy also challenges the slot-gap scenario.
Resumo:
Local trajectories and arrangements play a significant role because the development of a research field, such as nanoscience and nanotechnology, requires substantial investments in human and instrumental resources. But why are there often concentrated in a limited number of places? What dynamics lead to such concentration? The hypothesis is that there is an assemblage of heterogeneous resources through the action of local actors. The chapter will explore, from an Actor Network Theory (ANT) perspective, how the local emergence of research dynamics from: the revival of local traditions, the local and national action of institutional entrepreneurs, controversial dynamics, and researchers' arrangements to involve other actors. It will examine how they connect up with each other and mutually commit themselves to the development of new technologies. It will focus on the role of narratives in this assembling: how were the local narratives of the past mobilized and to what effect.
Resumo:
La cigarette électronique produit de la vapeur à inhaler contenant du propylène-glycol, des arômes et de la nicotine libérée rapidement. 6,7% de la population suisse, surtout des fumeurs, ont essayé la cigarette électronique et 0,1% l'utilise quotidiennement. Malgré l'incertitude due au bas niveau de preuves, la cigarette électronique pourrait être efficace pour cesser ou réduire le tabagisme. La sécurité de la cigarette électronique est démontrée à court terme mais pas à long terme ; sa toxicité semble très inférieure à celle du tabac. Les non-fumeurs et les jeunes utilisent peu la cigarette électronique qui ne semble pas les amener au tabagisme. Les mesures de santé publique recommandées sont la régulation du produit avec contrôle de la qualité ainsi que l'interdiction d'usage dans les lieux publics, de publicité et de vente aux mineurs. Electronic cigarettes are devices producing vapour containing propylene-glycol, flavourings and quickly delivered nicotine. 6.7% of the Swiss population, mainly smokers, experimented the electronic cigarette while 0.1% use it daily. Despite uncertainty due to the low level of evidence, electronic cigarettes might be effective for smoking cessation and reduction. The safety of electronic cigarettes is demonstrated at short-term but not at long-term; however its eventual toxicity is likely to be much lower than tobacco. Use of electronic cigarettes by non-smokers and youth who do not smoke is low and seems unlikely to lead them to tobacco use. Recommended public health measures include product regulation with quality control, ban in public places, prohibition of advertising and sales to minors.
Resumo:
Les pistolets à impulsion électrique (PIE) sont de plus en plus fréquemment utilisés en Europe ces dernières années, le modèle le plus connu étant le Taser®. Les connaissances scientifiques concernant les PIE et leurs effets potentiels restent toutefois limitées. Nous avons conduit une revue de littérature afin d'évaluer les implications potentielles de leur utilisation en termes de sécurité, de morbidité et de mortalité. Une exposition unique chez un individu sain peut généralement être considérée comme peu dangereuse. Les sujets à risque de complications sont les individus exposés à de multiples décharges, les personnes sous l'influence de substances psychoactives, ceux qui montrent des signes d'agitation extrême, ou encore les individus présentant des comorbidités médicales. L'éventail des complications pouvant survenir lors de leur exposition est large et inclut les lésions provoquées par les impacts des électrodes, les traumatismes liés à la chute induite par la paralysie transitoire ou des complications cardiovasculaires. Dans ce contexte, les personnes exposées doivent être examinées attentivement, et les éventuelles lésions traumatiques doivent être exclues. The use of electronic control devices (ECD), such as the Taser®, has increased in Europe over the past decade. However, scientific data concerning the potential health impact of ECD usage remains limited. We reviewed the scientific literature in order to evaluate the safety, mortality, and morbidity associated with ECD use. Exposure of a healthy individual to a single ECD electroshock can be considered generally safe. Complications can, however, occur if the patient is subject to multiple electroshocks, if the patient has significant medical comorbidities, or when exposure is associated with drug abuse or agitated delirium. The broad spectrum of potential complications associated with ECD exposure includes direct trauma caused by the ECD electrodes, injuries caused by the transient paralysis-induced fall, and cardiovascular events. An ECD-exposed patient requires careful examination during which traumatic injuries are actively sought out.
Resumo:
How to recognize, announce and analyze incidents in internal medicine units is a daily challenge that is taught to all hospital staff. It allows suggesting useful improvements for patients, as well as for the medical department and the institution. Here is presented the assessment made in the CHUV internal medicine department one year after the beginning of the institutional procedure which promotes an open process regarding communication and risk management. The department of internal medicine underlines the importance of feedback to the reporters, ensures the staff of regular follow-up concerning the measures being taken and offers to external reporters such as general practioners the possibility of using this reporting system too.
Resumo:
Objectifs: Dans certains pays, les cigarettes électroniques contenant de la nicotine (e-cigarettes) sont considérées comme des produits de consommation courante, sans régulation spécifique. Dans d'autres (comme en Suisse), la vente d'e-cigarettes contenant de la nicotine est interdite, malgré l'importante demande de nombreux fumeurs de pouvoir les obtenir. Au vu du manque de données scientifiques sur l'efficacité et la sécurité à long-terme de ces produits, les spécialistes de la lutte contre le tabagisme se trouvent divisés sur la question de leur régulation. Afin d'obtenir un consensus parmi ces experts que nous puissions transmettre aux autorités sanitaires, nous avons réalisé une étude d'avis d'experts sur le plan national. Méthode : Nous avons utilisé une méthodologie Delphi, à l'aide de questionnaires électroniques, afin de synthétiser l'opinion d'experts suisses sur la question de la cigarette électronique. Participants : 40 experts suisses représentant l'ensemble de la Suisse. Mesures : Nous avons mesuré le degré de consensus entre les experts au sujet de recommandations touchant à la régulation, la vente et l'utilisation de l'e-cigarette contenant de la nicotine, ainsi que leur opinion générale sur le produit. De nouvelles recommandations et déclarations ont été formulées en tenant compte des réponses et des commentaires des participants. Résultats : Un consensus entre les experts a établi que l'e-cigarette contenant de la nicotine devrait être accessible en Suisse, mais seulement dans des conditions spécifiques. La vente devrait être réservée aux adultes, en utilisant des standards de qualité, une limite de concentration maximale de nicotine, et être accompagnée d'une liste d'ingrédients autorisés. La publicité devrait être restreinte et l'utilisation de l'e- cigarette devrait être interdite dans les lieux publics. Conclusions : Ces recommandations permettent de regrouper trois principes : 1) le principe de réalité, étant donné que le produit est déjà disponible sur le marché ; 2) le principe de prévention, puisque l'e- cigarette procure une alternative au tabac pour les fumeurs actuels, et 3) le principe de précaution, afin de protéger les mineurs et les non-fumeurs, étant donné que les effets à long-terme ne sont pas encore connus. Les autorités suisses devraient mettre en place une législation spécifique afin d'autoriser l'e- cigarette contenant de la nicotine.
Resumo:
This study was aimed to analyze and assess the use and perception of electronic health records (EHRs) by nurses. The study sample included 113 nurses from different shifts of primary health facilities in Catalonia, Spain, devoted to adult as well as pediatric outpatients using EHRs throughout the year 2010. A majority of the sample (87.5%) were women and 12.5% were men. The average age was 44.27 years and the average time working in primary healthcare was 47.15 months. A majority (80.4%) received specific training on the use of the EHR and 19.6% did not. The use of the application required side technical support (mean: 3.42) and it is considered necessary to learn more about the performance of the application (mean: 3.50). The relationship between the average ratings that nurses have about the EHR and age shows that there is no statistically significant linear relationship (r = - 0.002, p-value = 0.984). As to how long they have used the EHRs, there are significant differences (r= -0.304, p-value = 0.00), so the more time the nurse takes using the EHR, the greater degree of satisfaction is shown. In addition, there are significant differences between nurses" perceptions regarding the EHR and gender (t = - 0.421, p-value = 0.675). Nurses assessed as positive the contribution of the EHRs in their nursing care day work (average score: 2.55/5). Considering that the usability of the EHR device is assessed as satisfactory, the results of the perception of nurses show that we must also take into account the training and emphasize the need for a side technical support in the implementation process of the EHR. Doing so, the positive perception that nurses have in regard to information and communication technology in general and with respect to the EHR in particular may be increased.
Resumo:
This study was aimed to analyze and assess the use and perception of electronic health records (EHRs) by nurses. The study sample included 113 nurses from different shifts of primary health facilities in Catalonia, Spain, devoted to adult as well as pediatric outpatients using EHRs throughout the year 2010. A majority of the sample (87.5%) were women and 12.5% were men. The average age was 44.27 years and the average time working in primary healthcare was 47.15 months. A majority (80.4%) received specific training on the use of the EHR and 19.6% did not. The use of the application required side technical support (mean: 3.42) and it is considered necessary to learn more about the performance of the application (mean: 3.50). The relationship between the average ratings that nurses have about the EHR and age shows that there is no statistically significant linear relationship (r = - 0.002, p-value = 0.984). As to how long they have used the EHRs, there are significant differences (r= -0.304, p-value = 0.00), so the more time the nurse takes using the EHR, the greater degree of satisfaction is shown. In addition, there are significant differences between nurses" perceptions regarding the EHR and gender (t = - 0.421, p-value = 0.675). Nurses assessed as positive the contribution of the EHRs in their nursing care day work (average score: 2.55/5). Considering that the usability of the EHR device is assessed as satisfactory, the results of the perception of nurses show that we must also take into account the training and emphasize the need for a side technical support in the implementation process of the EHR. Doing so, the positive perception that nurses have in regard to information and communication technology in general and with respect to the EHR in particular may be increased.
Resumo:
Automation was introduced many years ago in several diagnostic disciplines such as chemistry, haematology and molecular biology. The first laboratory automation system for clinical bacteriology was released in 2006, and it rapidly proved its value by increasing productivity, allowing a continuous increase in sample volumes despite limited budgets and personnel shortages. Today, two major manufacturers, BD Kiestra and Copan, are commercializing partial or complete laboratory automation systems for bacteriology. The laboratory automation systems are rapidly evolving to provide improved hardware and software solutions to optimize laboratory efficiency. However, the complex parameters of the laboratory and automation systems must be considered to determine the best system for each given laboratory. We address several topics on laboratory automation that may help clinical bacteriologists to understand the particularities and operative modalities of the different systems. We present (a) a comparison of the engineering and technical features of the various elements composing the two different automated systems currently available, (b) the system workflows of partial and complete laboratory automation, which define the basis for laboratory reorganization required to optimize system efficiency, (c) the concept of digital imaging and telebacteriology, (d) the connectivity of laboratory automation to the laboratory information system, (e) the general advantages and disadvantages as well as the expected impacts provided by laboratory automation and (f) the laboratory data required to conduct a workflow assessment to determine the best configuration of an automated system for the laboratory activities and specificities.
Resumo:
Peer-reviewed
Resumo:
By using thermochemical data reported for a series of chelates of the type [Ln(thd)3], thd = 2, 2, 6, 6 tetramethyl- 3,5-heptanedione and Ln = La, Pr, Nd, Sm, Gd, Tb, Ho, Er, Tm and Yb, empirical correlations were found involving thermochemical parameters (e.g. dissociation enthalpy) and the thermodynamic temperatures of the beginning of thermal degradation of the chelates, t i. It is shown that t i values are of capital importance in the study of this all class of coordination compounds. Among others, the empirical equation is obtained: r3+ = (-0,013.Z + 1,36)/0,005, that relates the lanthanide cation radius (pm) with the atomic number of the element. The remarkable fact is that this equation is achieved by using thermogravimetric and calorimetric parameters. Is also shown that t i values are related with the P(M) function values, which are very close related with the energy difference, deltaE, between the lowest electronic energy level of the f n s²d¹ configuration and the lowest energy level of the f n+1s² configuration in the neutral gaseous atoms.
Resumo:
Keeping track of software assets and managing software installations in IT environments can be a hard endeavor, especially when the size and diversity of the environment grows. How to install and uninstall software efficiently and cost effectively? Are there too few or too many software licenses purchased? If installed, is the software actually in use? Software Asset Management (SAM) is a process that involves managing and optimizing the purchase, deployment, maintenance, utilization, and disposal of software applications within an organization. This master’s thesis describes a special Software Lifecycle Management Framework to provide solutions to the multitude of challenges within SAM. The main objectives when designing the framework was to provide a set of tools to control the software assets during their entire lifecycle while trying to minimize the costs related to owning and managing them.