997 resultados para dano mecânico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Linguarum Vett. septentrionalium thesaurus grammatico-criticus et archaelogicus. 1705 : Linguarum Vett. septentrionalium thesauri ... pars prima[-tertia]. 1703 ; De antiquae litteraturae septentrionalis utilitate usu ... Dissertatio epistolaris ad Bartholomaeum Showere. 1703 ; Numismata Anglo-Saxonica & Anglo-Danica breviter illustrata ab Andrea Fountaine. 1705 ; Antiquae literaturae septentrionalis liber alter seu Humpredi Wanleii ... 1705 ; Indices totius operis. 1703.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to study and investigate the use of a hybrid composite polymer formed with blanket aramid (Kevlar 29) fiber blanket flax fiber and particulate dry endocarp of coconut (Cocos nucifera Linn), using as matrix an epoxy resin based thermoset for use in areas of protective equipment. Besides such material is used an aluminum plate, joined to the composite by means of glue based on epoxy and araldite commercial. The manufacturing process adopted was manual lamination (Hand Lay Up) to manufacture the hybrid composite. After the composite is prepared, an aluminum plate is subjected to pressure and glued to cure the adhesive. Layers of veil will also be used to separate the particulate from the linen blanket layer without disturbing the alignment of the fibers of the blankets. To characterize the mechanical and physical behavior was manufactured a plate of 800 x 600 mm of the hybrid composite, which were removed specimens for tests of water absorption to saturation; density; impact test (Charpy) and two test specimens for ballistic testing 220 mm x 200 mm to make a comparative study between the dry state and saturated water absorption and thus see the ballistic performance of these two conditions. The test was applied to make a comparative study of fracture in these two conditions, caused by penetrating ballistic missile (38 and 380). To test the impact (Charpy) will analyze the absorbed energy, fracture appearance and lateral contraction, also in dry condition and saturation of absorbed water, thereby analyzing situations where the impact load is relevant, such as bumps and shocks produced by stone, metal or wooden bars among others. The proposed configuration, along with the tests, has the purpose, application in the fields of equipment against ballistic impact, such as helmets; bullet proof vests; shields; protective packaging and other items to be identified in this research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The polymer matrix composite materials are being used on a large scale in the most different industrial fields such as aerospace, automotive, oil, among others, since the industrial perspectives is currently working with materials which have a good mechanical performance at high service life and cost / benefit. Thus, the determination of the mechanical properties is indispensable for the characterization of waste resulting in greater expansion of this type of material. Thus, this work will be obtained three plates laminated with tereftálica polymeric matrix reinforced by a bidirectional woven E-glass and kevlar both industrially made, where the plates are manufactured by manual lamination process (hand lay-up), all laminates have five enhancement layers, the first hybrid laminate will consist of bidirectional woven E-glass fiber, kevlar fiber interspersed with layers, is formed by the second bidirectional woven kevlar fiber at the ends of the laminate (two layers), and in the center the glass fiber fabric (three layers), the third plate is composed of only the bidirectional woven E-glass fiber. Then were prepared specimens (CP) by standard, to determine the mechanical properties of tensile and bending in three points. After fabrication of the specimens, they were immersed in oil and seawater. After that, there was a comparison of the mechanical properties for the test condition in the dry state. Showing that there was a considerable increase in the properties studied because the effect of hybridization in laminates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: analyze the effect of Kinesio Taping (KT) on the indirect clinical markers of muscle damage induced by eccentric exercises in the elbow flexors in healthy individuals. Materials and methods: It is a randomized controlled trial involving sixty volunteers at age group between 18 and 28 years randomly selected. The sample into three groups with twenty participants: control group (CG) – eccentric protocol without KT, KT group – eccentric with tensioned KT, placebo group – eccentric protocol KT with no tension. The evaluations took place at four moments; the first one was the basis line (AV1), after the second protocol (AV2) and the following two groups 24 (AV3) and 48 hours (AV4) after the intervention protocol. The muscle damage was induced by sixteen maximum eccentric contractions of the elbow flexors from the non-dominant limb, divided in two sets of eight repetitions, at 60º/s, with two minutes interval. The variables analyzed were: the joint amplitude in rest, the level of pain, the joint position sense (JPS) followed of isokinetic checking with electromyographic sign capitation. These data were analyzed in software SPSS 20.0. The normality was identified by Kolmogorov-Smimov examination and then, being used the ANOVA mixed model with significance of 5%. Outcomes: a decrease was observed at joint amplitude moreover, an immediate increase of pain wich increased after 24 and remained until 48 hours at all groups searched. There was not difference at the JPS. The variables peak torque, average peak torque, total work and mean power mean reduced until 48 hours after muscle lesion in all groups. Among the groups, there was no difference in EMG values and for any of the variables. Conclusion: The KT did not influence at the indirect clinical markers of muscle lesion induced by eccentric exercises in the elbow flexors in healthy people.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: analyze the effect of Kinesio Taping (KT) on the indirect clinical markers of muscle damage induced by eccentric exercises in the elbow flexors in healthy individuals. Materials and methods: It is a randomized controlled trial involving sixty volunteers at age group between 18 and 28 years randomly selected. The sample into three groups with twenty participants: control group (CG) – eccentric protocol without KT, KT group – eccentric with tensioned KT, placebo group – eccentric protocol KT with no tension. The evaluations took place at four moments; the first one was the basis line (AV1), after the second protocol (AV2) and the following two groups 24 (AV3) and 48 hours (AV4) after the intervention protocol. The muscle damage was induced by sixteen maximum eccentric contractions of the elbow flexors from the non-dominant limb, divided in two sets of eight repetitions, at 60º/s, with two minutes interval. The variables analyzed were: the joint amplitude in rest, the level of pain, the joint position sense (JPS) followed of isokinetic checking with electromyographic sign capitation. These data were analyzed in software SPSS 20.0. The normality was identified by Kolmogorov-Smimov examination and then, being used the ANOVA mixed model with significance of 5%. Outcomes: a decrease was observed at joint amplitude moreover, an immediate increase of pain wich increased after 24 and remained until 48 hours at all groups searched. There was not difference at the JPS. The variables peak torque, average peak torque, total work and mean power mean reduced until 48 hours after muscle lesion in all groups. Among the groups, there was no difference in EMG values and for any of the variables. Conclusion: The KT did not influence at the indirect clinical markers of muscle lesion induced by eccentric exercises in the elbow flexors in healthy people.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The general aim of this study was to evaluate the conical interface of pilar/implant. The specific aims were to evaluate the influence of hexagonal internal index in the microleakage and mechanical strength of Morse taper implants; the effect of axial loading on the deformation in cervical region of Morse taper implants of different diameters through strain gauge; the effect of axial loading in cervical deformation and sliding of abutment into the implant by tridimensional measurements; the integrity of conical interface before and after dynamic loading by microscopy and microleakage; and the stress distribution in tridimensional finite element models of Morse taper implants assembled with 2 pieces abutment. According to the obtained results, could be concluded that the diameter had influence in the cervical deformation of Morse taper implants; the presence of internal hexagonal index in the end of internal cone of implant didn´t influenced the bacterial microleakage under static loading neither reduced the mechanical strength of implants; one million cycles of vertical and off-center load had no negative influence in Morse taper implant integrity.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LINS, Filipe C. A. et al. Modelagem dinâmica e simulação computacional de poços de petróleo verticais e direcionais com elevação por bombeio mecânico. In: CONGRESSO BRASILEIRO DE PESQUISA E DESENVOLVIMENTO EM PETRÓLEO E GÁS, 5. 2009, Fortaleza, CE. Anais... Fortaleza: CBPDPetro, 2009.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Programa de doctorado: Avances en Traumatología. La fecha de publicación es la fecha de lectura

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la actualidad casi la totalidad de los reactores nucleares necesitan, como combustible, uranio con una concentración de U"235 mayores a las naturales. En un marco de autoabastecimiento se impone la necesidad de dominar la tecnología necesaria para enriquecer uranio, siendo las centrifugas el método usado industrialmente hoy en día. Esta tecnología, por cuestiones de proliferación, es considerada sensitiva y en consecuencia la información sobre la misma se encuentra fuertemente limitada. En el presente trabajo se propone un modelo simplificado para diseñar y evaluar conceptualmente diseños mecánicos de rotores, proponiendo como figura de merito el trabajo separativo para centrifugas de gas. Con el mismo se pudo, evaluando distintos materiales para el rotor, encontrar radios y alturas óptimos para la capacidad separativa por unidad de masa para cada uno de ellos. Se evaluaron los parámetros que definen la recirculación interna del flujo dentro del rotor y los parámetros de diseño mecánico. Al comparar los resultados con los disponibles en bibliografía se vio que presentan buena concordancia mecánica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la actualidad casi la totalidad de los reactores nucleares necesitan, como combustible, uranio con una concentración de U"235 mayores a las naturales. En un marco de autoabastecimiento se impone la necesidad de dominar la tecnología necesaria para enriquecer uranio, siendo las centrifugas el método usado industrialmente hoy en día. Esta tecnología, por cuestiones de proliferación, es considerada sensitiva y en consecuencia la información sobre la misma se encuentra fuertemente limitada. En el presente trabajo se propone un modelo simplificado para diseñar y evaluar conceptualmente diseños mecánicos de rotores, proponiendo como figura de merito el trabajo separativo para centrifugas de gas. Con el mismo se pudo, evaluando distintos materiales para el rotor, encontrar radios y alturas óptimos para la capacidad separativa por unidad de masa para cada uno de ellos. Se evaluaron los parámetros que definen la recirculación interna del flujo dentro del rotor y los parámetros de diseño mecánico. Al comparar los resultados con los disponibles en bibliografía se vio que presentan buena concordancia mecánica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La aplicadora está basada en la utilización de un sistema autopropulsado de tracción mecánica, el cual dispone de un sistema de rodadura de cadenas. Sobre dicho equipo de tracción, se dispondrán de los diversos elementos necesarios para realizar la aplicación de productos fitosanitarios, como por ejemplo un equipo de pulverización, nebulización, etc. El equipo podrá ser utilizado como pulverizador, atomizador, nebulizador y sistema de distribución acoplado a una, instalación fija de productos fitosanitarios de un invernadero, controlando en todas las ocasiones la dosis aplicada sin depender del operario encargado de la aplicación. Este dispositivo presenta una alternativa más eficaz en lo referente a la uniformidad de la distribución, lo que genera una disminución en las dosis aplicadas beneficiando las condiciones de seguridad del operario y el impacto sobre el medio ambiente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LINS, Filipe C. A. et al. Modelagem dinâmica e simulação computacional de poços de petróleo verticais e direcionais com elevação por bombeio mecânico. In: CONGRESSO BRASILEIRO DE PESQUISA E DESENVOLVIMENTO EM PETRÓLEO E GÁS, 5. 2009, Fortaleza, CE. Anais... Fortaleza: CBPDPetro, 2009.