777 resultados para corneal
Resumo:
PURPOSE: Primary angle-closure glaucoma (PACG) is more prevalent among Chinese than whites. The authors tested the hypothesis that Chinese have shallower anterior chambers than do whites, a factor that may be related to PACG prevalence. METHODS: The authors compared anterior chamber depth, axial length, radius of corneal curvature, and refractive error among 531 Chinese, 170 whites, and 188 blacks older than 40 years of age using the same model of instruments and identical technique. RESULTS: Mean anterior chamber depth and axial length did not differ significantly for the three groups. Whites had a significantly higher prevalence of hyperopia > 2 diopters than did Chinese. Radius of corneal curvature was significantly smaller among Chinese than whites or blacks. CONCLUSIONS: These results suggest that Chinese do not differ on a population basis from other ethnic groups in many of the biometric risk factors known to be of importance for PACG. It will be necessary to identify other ocular biometric parameters to explain the excess burden of PACG among Chinese, which may improve the effectiveness of screening for this disease in all populations.
Resumo:
PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.
Resumo:
PURPOSE:
The purpose of this study was to report on Tsukamurella as a mimic of atypical mycobacterial infection.
METHODS:
We report a patient who had received repeated corneal grafts with culture-proven Tsukamurella keratitis.
RESULTS:
A slow-progressing corneal abscess that initially developed adjacent to a corneal stitch responded poorly to empiric antibiotic treatment. A preliminary culture report revealed fast-growing mycobacterial species. Treatment adjustments successfully controlled the disease. A final diagnosis of Tsukamurella was subsequently made on the basis of cultures.
CONCLUSIONS:
Tsukamurella exhibits laboratory similarities to mycobacteria and should be considered in the differential of atypical infection of the ocular surface.
Resumo:
PURPOSE:
To compare the outcomes of cataract surgery performed with 3 incision size-dependent phacoemulsification groups (1.8, 2.2, and 3.0 mm).
DESIGN:
Prospective randomized comparative study.
METHODS:
One hundred twenty eyes of 120 patients with age-related cataract (grades 2 to 4) were categorized according to the Lens Opacities Classification System III. Eligible subjects were randomly assigned to 3 surgical groups using coaxial phacoemulsification through 3 clear corneal incision sizes (1.8, 2.2, and 3.0 mm). Different intraoperative and postoperative outcome measures were obtained, with corneal incision size and surgically induced astigmatism as the main clinical outcomes.
RESULTS:
There were no statistically significant differences in most of the intraoperative and postoperative outcome measures among the 3 groups. However, the mean cord length of the clear corneal incision was increased in each group after surgery. The mean maximal clear corneal incision thickness in the 1.8-mm group was significantly greater than for the other groups at 1 month. The mean surgically induced astigmatism in the 1.8- and 2.2-mm groups was significantly less than that in the 3.0-mm group after 1 month, without significant difference between the 1.8- and 2.2-mm groups.
CONCLUSIONS:
With appropriate equipment, smaller incisions may result in less astigmatism, but the particular system used will influence incision stress and wound integrity, and may thus limit the reduction in incision size and astigmatism that is achievable.
Resumo:
PURPOSE: To evaluate the agreement between optical low-coherence reflectometry (OLCR) and anterior segment optical coherence tomography (AS-OCT) for biometry of the anterior segment. SETTING: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Evaluation of diagnostic technology. METHODS: A series of OLCR (Lenstar LS 900) and AS-OCT measurements of the anterior segment were taken for consecutive subjects aged 35 years and older in a population-based study. The differences and correlations between the 2 methods of ocular biometry were assessed. Agreement was calculated as the 95% limits of agreement (LoA). RESULTS: The mean age of the 776 subjects was 55.2 years ± 12.0 (SD); 54.6% were women. The mean central corneal thickness (CCT) was smaller with OLCR than with AS-OCT (537.84 ± 31.46 μm versus 559.39 ± 32.02 μm) as was anterior chamber depth (ACD) (2.60 ± 0.37 mm versus 2.72 ± 0.37 mm) and anterior chamber width (ACW) (11.76 ± 0.47 mm versus 12.04 ± 0.55 mm) (all P<.001). The 95% LoA between the 2 instruments were -44.80 to 1.71 μm for CCT, -0.17 to -0.06 mm for ACD, and -1.28 to 0.72 mm for ACW. CONCLUSION: Optical low-coherence reflectometry and AS-OCT yielded potentially interchangeable ACD measurements, while the CCT and ACW measurements acquired by the 2 devices showed clinically significant differences.
Resumo:
Bien qu’ils soient exposés tous deux aux rayons ultraviolets (UVR) solaires, cette exposition génotoxique n’entraîne pas les mêmes conséquences dans l’oeil et la peau. Le rôle des rayons UV dans l’induction et la progression des cancers cutanés est bien démontré. Ces rayons génotoxiques sont absorbés par l’ADN. Ils y induisent ainsi des changements conformationnels pouvant mener à la formation de différents dommages. On retrouve de façon prédominante la liaison de pyrimidines adjacentes en dimères cyclobutyliques de pyrimidines (CPD). Ceux-ci causent les mutations signatures responsables des cancers de la peau induits par les UVR. Cependant, aucune évidence ne démontre l’existence de cancer induit par les UVR dans la cornée. Nous avons donc tenté de découvrir les mécanismes permettant à la cornée d’éviter la transformation tumorale induite par les UVR. L’irradiation d’yeux de lapins aux rayons UVB a permis de prouver la capacité de ces rayons à induire la formation de CPD, et ce, de la cornée jusqu’au cristallin. Par la suite, l’irradiation d’yeux humains aux trois types de rayons UV (UVA, B et C) a permis d’y établir leur patron d’induction de CPD. Nous avons ainsi démontré que l’épithélium cornéen est particulièrement sensible à l’induction de CPD, tous types de rayons UV confondus. Enfin, la comparaison de la quantité de dommages présents dans des échantillons de peaux et de cornées irradiées à la même dose d’UVB a permis de démontrer que l’épithélium cornéen est 3.4 fois plus sensible à l’induction de CPD que l’épiderme. Nous avons par la suite étudié les mécanismes de réponse à ce stress. L’analyse de la viabilité cellulaire à la suite d’irradiations à différentes doses d’UVB a révélé que les cellules de la cornée et de la peau ont la même sensibilité à la mort cellulaire induite par les UVR. Nous avons alors analysé la vitesse de réparation des dommages induits par les UVR. Nos résultats démontrent que les CPD sont réparés 4 fois plus rapidement dans les cellules de la cornée que de la peau. L’analyse des protéines de reconnaissance des dommages a révélé que les cellules de la cornée possèdent plus de protéines DDB2 que les cellules de la peau, et ce, surtout liées à la chromatine. Nous avons alors tenté d’identifier la cause de cette accumulation. Nos analyses révèlent que la cornée possède une moins grande quantité d’ARNm DDB2, mais que la demi-vie de la protéine y est plus longue. Enfin, nos résultats suggèrent que l’accumulation de DDB2 dans les cellules de la cornée est entre autres due à une demi-vie plus longue de la protéine. Cette forte présence de DDB2 dans les cellules de la cornée permettrait un meilleur balayage de l’ADN, faciliterait de ce fait la détection de CPD ainsi que leur réparation et contribuerait donc à la capacité de la cornée à éviter la transformation tumorale induite par les UVR.
Resumo:
Recent changes in regulatory requirements and social views on animal testing have incremented the development of reliable alternative tests for predicting skin and ocular irritation potential of products based on new raw materials. In this regard, botanical ingredients used in cosmetic products are among those materials, and should be carefully reviewed concerning the potential presence of irritant constituents. In particular, cosmetic products used on the face, in vicinity of the eyes or that may come in contact with mucous membranes, should avoid botanical ingredients that contain, or are suspected to contain, such ingredients. In this study, we aimed to evaluate the effect of a new cosmetic ingredient, namely, coffee silverskin (CS), with an in vitro skin and ocular irritation assay using reconstructed human epidermis, EpiSkin™, and human corneal epithelial model, SkinEthics™ HCE, and an in vivo assay. Three different extracts of CS were evaluated. The histology of the models after extracts applications was analysed. The in vitro results demonstrated that extracts were not classified as irritant and the histological analyses proved that extracts did not affect both models structure. The content of caffeine, 5-hydroxymethyl furfural and chlorogenic acid was quantified after the epidermal assay. The in vivo test carried out with the most promising extract (hydroalcoholic) showed that, with respect to irritant effects, these extracts can be regarded as safe for topical application.
Resumo:
Introduced in 2008, the femtosecond laser is a promising new technological advance which plays an ever increasing role in cataract surgery where it automates the three main surgical steps: corneal incision, capsulotomy and lens fragmentation. The proven advantages over manual surgery are: a better quality of incision with reduced induced astigmatism; increased reliability and reproducibility of the capsulotomy with increased stability of the implanted lens; a reduction in the use of ultrasound. Regarding refractive results or safety, however, no prospective randomized study to date has shown significant superiority compared with standard manual technique. The significant extra cost generated by this laser, undertaken by the patient, is a limiting factor for both its use and study. This review outlines the potential benefits of femtosecond-laser-assisted cataract surgery due to the automation of key steps and the safety of this new technology.
Resumo:
PURPOSE: The aim of the present study was the in vitro and in vivo evaluation of a novel aqueous formulation based on polymeric micelles for the topical delivery of cyclosporine A for dry eye treatment. METHODS: In vitro experiments were carried out on primary rabbit corneal cells, which were characterized by immunocytochemistry using fluorescein-labeled lectin I/isolectin B4 for the endothelial cells and mouse monoclonal antibody to cytokeratin 3+12 for the epithelial ones. Living cells were incubated for 1 hour or 24 hours with a fluorescently labeled micelle formulation and analyzed by fluorescence microscopy. In vivo evaluations were done by Schirmer test, osmolarity measurement, CyA kinetics in tears, and CyA ocular distribution after topical instillation. A 0.05% CyA micelle formulation was compared to a marketed emulsion (Restasis). RESULTS: The in vitro experiments showed the internalization of micelles in the living cells. The Schirmer test and osmolarity measurements demonstrated that micelles did not alter the ocular surface properties. The evaluation of the tear fluid gave similar CyA kinetics values: AUC = 2339 ± 1032 min*μg/mL and 2321 ± 881.63; Cmax = 478 ± 111 μg/mL and 451 ± 74; half-life = 36 ± 9 min and 28 ± 9 for the micelle formulation and Restasis, respectively. The ocular distribution investigation revealed that the novel formulation delivered 1540 ± 400 ng CyA/g tissue to the cornea. CONCLUSIONS: The micelle formulation delivered active CyA into the cornea without evident negative influence on the ocular surface properties. This formulation could be applied for immune-related ocular surface diseases.
Resumo:
BIGH3 is a secreted protein, part of the extracellular matrix where it interacts with collagen and integrins on the cell surface. BIGH3 can play opposing roles in cancer, acting as either tumor suppressor or promoter, and its mutations lead to different forms of corneal dystrophy. Although many studies have been carried out, little is known about the physiological role of BIGH3. Using the cre-loxP system, we generated a mouse model with disruption of the Bigh3 genomic locus. Bigh3 silencing did not result in any apparent phenotype modifications, the mice remained viable and fertile. We were able to determine the presence of BIGH3 in the retinal pigment epithelium (RPE). In the absence of BIGH3, a transient decrease in the apoptotic process involved in retina maturation was observed, leading to a transient increase in the INL thickness at P15. This phenomenon was accompanied by an increased activity of the pro-survival ERK pathway.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Resumo:
Cette thèse porte sur l’étude de l’anatomie de la cornée après 3 techniques de greffe soient, la greffe totale traditionnelle (GTT) et des techniques de greffe lamellaire postérieur (GLP) telles que la greffe lamellaire endothéliale profonde (DLEK) et la greffe endothélium/membrane de Descemet (EDMG) pour le traitement des maladies de l’endothélium, telles que la dystrophie de Fuchs et de la kératopathie de l’aphaque et du pseudophaque. Dans ce contexte, cette thèse contribue également à démontrer l’utilité de la tomographie de cohérence optique (OCT) pour l’étude de l’anatomie des plaies chirurgicales la cornée post transplantation. Au cours de ce travail nous avons étudié l'anatomie de la DLEK, avant et 1, 6, 12 et 24 mois après la chirurgie. Nous avons utilisé le Stratus OCT (Version 3, Carl Zeiss, Meditec Inc.) pour documenter l’anatomie de la plaie. L'acquisition et la manipulation des images du Stratus OCT, instrument qui à été conçu originalement pour l’étude de la rétine et du nerf optique, ont été adaptées pour l'analyse du segment antérieur de l’oeil. Des images cornéennes centrales verticales et horizontales, ainsi que 4 mesures radiaires perpendiculaires à la plaie à 12, 3, 6 et 9 heures ont été obtenues. Les paramètres suivants ont été étudiés: (1) Les espaces (gap) entre les rebords du disque donneur et ceux du receveur, (2) les dénivelés de surface postérieure (step) entre le les rebords du disque donneur et ceux du receveur, (3) la compression tissulaire, (4) le décollement du greffon, 6) les élévations de la surface antérieure de la cornée et 7) la pachymétrie centrale de la cornée. Les mesures d’épaisseur totale de la cornée ont été comparées et corrélées avec celles obtenues avec un pachymètre à ultra-sons. Des mesures d’acuité visuelle, de réfraction manifeste et de topographie ont aussi été acquises afin d’évaluer les résultats fonctionnels. Enfin, nous avons comparé les données de DLEK à celles obtenues de l’EDMG et de la GTT, afin de caractériser les plaies et de cerner les avantages et inconvénients relatifs à chaque technique chirurgicale. Nos résultats anatomiques ont montré des différences importantes entre les trois techniques chirurgicales. Certains des paramètres étudiés, comme le sep et le gap, ont été plus prononcés dans la GTT que dans la DLEK et complètement absents dans l’EDMG. D’autres, comme la compression tissulaire et le décollement du greffon n’ont été observés que dans la DLEK. Ceci laisse entrevoir que la distorsion de la plaie varie proportionnellement à la profondeur de la découpe stromale du receveur, à partir de la face postérieure de la cornée. Moins la découpe s’avance vers la face antérieure (comme dans l’EDMG), moins elle affecte l’intégrité anatomique de la cornée, le pire cas étant la découpe totale comme dans la GTT. Cependant, tous les paramètres d’apposition postérieure sous-optimale et d’élévation de la surface antérieure (ce dernier observé uniquement dans la GTT) finissent par diminuer avec le temps, évoluant à des degrés variables vers un profil topographique plus semblable à celui d’une cornée normale. Ce processus paraît plus long et plus incomplet dans les cas de GTT à cause du type de plaie, de la présence de sutures et de la durée de la cicatrisation. Les valeurs moyennes d’épaisseur centrale se sont normalisées après la chirurgie. De plus, ces valeurs moyennes obtenues par OCT étaient fortement corrélées à celles obtenues par la pachymétrie à ultra-sons et nous n’avons remarqué aucune différence significative entre les valeurs moyennes des deux techniques de mesure. L’OCT s’est avéré un outil utile pour l’étude de l’anatomie microscopique des plaies chirurgicales. Les résultats d’acuité visuelle, de réfraction et de topographie des techniques de GLP ont montré qu’il existe une récupération visuelle rapide et sans changements significatifs de l’astigmatisme, contrairement à la GTT avec et sans suture. La GLP a permis une meilleure conservation de la morphologie de la cornée, et par conséquence des meilleurs résultats fonctionnels que la greffe de pleine épaisseur. Ceci nous permet d’avancer que la GLP pourrait être la technique chirurgicale à adopter comme traitement pour les maladies de l’endothélium cornéen.
Resumo:
Le virus herpès simplex de type 1 (HSV 1) affecte la majorité de la population mondiale. HSV 1 cause de multiples symptômes délétères dont les plus communs sont les lésions orofaciales usuellement appelées feux sauvages. Le virus peut aussi causer des effets plus sérieux comme la cécité ou des troubles neurologiques. Le virus réside de façon permanente dans le corps de son hôte. Malgré l’existence de nombreux traitements pour atténuer les symptômes causés par HSV 1, aucun médicament ne peut éliminer le virus. Dans le but d’améliorer les connaissances concernant le cycle viral de HSV 1, ce projet cible l’étude du transport du virus dans la cellule hôte. Ce projet aura permis la collecte d’informations concernant le modus operandi de HSV 1 pour sortir des compartiments cellulaires où il séjourne. Les différentes expérimentations ont permis de publier 3 articles dont un article qui a été choisi parmi les meilleurs papiers par les éditeurs de « Journal of Virology » ainsi qu’un 4e article qui a été soumis. Premièrement, un essai in vitro reproduisant la sortie de HSV 1 du noyau a été mis sur pied, via l’isolation de noyaux issus de cellules infectées. Nous avons démontré que tout comme dans les cellules entières, les capsides s’évadent des noyaux isolés dans l’essai in vitro en bourgeonnant avec la membrane nucléaire interne, puis en s’accumulant sous forme de capsides enveloppées entre les deux membranes nucléaires pour finalement être relâchées dans le cytoplasme exclusivement sous une forme non enveloppée. Ces observations appuient le modèle de transport de dé-enveloppement/ré-enveloppement. Deuxièmement, dans le but d’identifier des joueurs clefs viraux impliqués dans la sortie nucléaire du virus, les protéines virales associées aux capsides relâchées par le noyau ont été examinées. La morphologie multicouche du virus HSV 1 comprend un génome d’ADN, une capside, le tégument et une enveloppe. Le tégument est un ensemble de protéines virales qui sont ajoutées séquentiellement sur la particule virale. La séquence d’ajout des téguments de même que les sites intracellulaires où a lieu la tégumentation sont l’objet d’intenses recherches. L’essai in vitro a été utilisé pour étudier cette tégumentation. Les données recueillies suggèrent un processus séquentiel qui implique l’acquisition des protéines UL36, UL37, ICP0, ICP8, UL41, UL42, US3 et possiblement ICP4 sur les capsides relâchées par le noyau. Troisièmement, pour obtenir davantage d’informations concernant la sortie de HSV 1 des compartiments membranaires de la cellule hôte, la sortie de HSV 1 du réseau trans golgien (TGN) a aussi été étudiée. L’étude a révélé l’implication de la protéine kinase D cellulaire (PKD) dans le transport post-TGN de HSV 1. PKD est connue pour réguler le transport de petits cargos et son implication dans le transport de HSV 1 met en lumière l’utilisation d’une machinerie commune pour le transport des petits et gros cargos en aval du TGN. Le TGN n’est donc pas seulement une station de triage, mais est aussi un point de rencontre pour différentes voies de transport intracellulaire. Tous ces résultats contribuent à une meilleure compréhension du processus complexe de maturation du virus HSV 1, ce qui pourrait mener au développement de meilleurs traitements pour combattre le virus. Les données amassées concernant le virus HSV 1 pourraient aussi être appliquées à d’autres virus. En plus de leur pertinence dans le domaine de la virologie, les découvertes issues de ce projet apportent également de nouveaux détails au niveau du transport intracellulaire.
Resumo:
Le déficit familial de LCAT (FLD) est une maladie caractérisée par un défaut de l’activité de l’enzyme lecithin:cholesterol acyltransferase (LCAT). Ce défaut résulte en une concentration plasmatique de C-HDL extrêmement basse, des opacités cornéennes prématurées, la présence d’anémie, de protéinurie et d’insuffisance rénale. Nous avons identifié les premiers patients canadiens-français atteints de déficit familial de LCAT. Deux frères, présentant les signes classiques de FLD étaient homozygotes pour une nouvelle mutation du gène de la LCAT: la mutation c.102delG. Cette mutation se traduit au niveau protéique par un changement du cadre de lecture au niveau du codon His35 et l’insertion d’un codon stop en position 61 entraînant une abolition de l’activité LCAT in vitro et in vivo. La présence de cette mutation cause une réduction importante du C-HDL chez les hétérozygotes (22%) et les homozygotes (88%) ainsi qu’une baisse du C-LDL chez les hétérozygotes (35%) et les homozygotes (58%). De plus, le profil lipidique différait de manière importante entre les deux frères atteints de FLD qui présentaient des génotypes APOE différents. Nous suggérons que APOE est un gène qui modifie le phénotype du FLD et pourrait expliquer l’hétérogénéité des profils lipidiques chez les patients atteints de FLD. Nos résultats suggèrent également que l’association du génotype LCAT-/- a un allèle APOE ε2 est un nouveau mécanisme conduisant à la dysbétalipoproteinemie. Finalement nous avons montré des différences importantes dans les sous-populations des HDL chez les deux sujets atteints de FLD. Le porteur de l’allèle APOE ε2 présentait une proportion beaucoup plus importante de HDL immatures (preβ discoïdaux) par rapport a son frère (77.9% vs. 31.0%).
Resumo:
Sommaire L’oxygène fait partie intégrante de l’environnement et ceci jusqu’au fonctionnement même des structures cellulaires qui composent le corps humain. Deux systèmes sont intimement liés à la distribution de l’oxygène, ce sont les systèmes cardiovasculaire et respiratoire. La transparence du système optique de l’œil peut être exploitée afin de mesurer de façon non invasive la concentration en oxyhémoglobine du sang qui alimente le système nerveux central. L’oxygénation capillaire de l’œil a été mesurée par spectro-réflectométrie dans deux régions de l’œil: d’une part les capillaires de la zone du nerf optique qui représentent principalement la circulation rétinienne; d’autre part, les capillaires du limbe cornéen. Cinq sujets volontaires, non fumeurs, sains, âgés de 20 à 45 ans et cinq sujets volontaires, fumeurs, sains, âgés de 20 à 40 ans ont participé à cette étude. Tous ces sujets ont été exposés à des conditions d’hyper et d’hypo oxygénation. Une séance d’expérimentations était composée d’un enregistrement continu de 360 secondes. Durant la première étape de 60 secondes, le sujet respirait de l’air ambiant. Durant une deuxième étape de 180 secondes, le sujet était exposé soit à une condition d’hyper (60% O2) soit, à une condition d’hypo oxygénation (15% O2), tandis que les 120 dernières secondes de la séance de mesure permettait d’exposer le sujet, une fois de plus à l’air ambiant. Le rythme cardiaque et les changements d’oxygénation artérielle au niveau du doigt étaient mesurés pendant ce temps vec le sphygmo-oxymètre. Les variations du taux d’oxyhémoglobine du sang au niveau capillaire de l’œil (nerf optique ou sclérotique) étaient toujours en corrélation directe avec les variations du taux d’oxyhémoglobine artériel. Toutefois, les capillaires du nerf optique offrent plus de précision pour les mesures d’oxygénation, relativement aux mesures d’oxygénation du sang contenu dans les capillaires de la sclérotique. La précision de la mesure de la concentration d’oxyhémoglobine obtenue dans cette étude par spectro-réflectométrie de l’œil, en fait un instrument utile au diagnostic d’une grande partie des pathologies pulmonaires ou oculaires.