974 resultados para analogy calculation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, alpha) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although literature presents several alternatives, an approach based on the electronic analogy was still not considered for the implementation of an inductor-free realization of the double scroll Chua`s circuit. This paper presents a new inductor-free configuration of the Chua`s circuit based on the electronic analogy. This proposal results in a versatile and functional inductorless implementation of the Chua`s circuit that offers new and interesting features for several applications. The analogous circuit is implemented and used to perform an experimental mapping of a large variety of attractors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The protective shielding design of a mammography facility requires the knowledge of the scattered radiation by the patient and image receptor components. The shape and intensity of secondary x-ray beams depend on the kVp applied to the x-ray tube, target/filter combination, primary x-ray field size, and scattering angle. Currently, shielding calculations for mammography facilities are performed based on scatter fraction data for Mo/Mo target/filter, even though modern mammography equipment is designed with different anode/filter combinations. In this work we present scatter fraction data evaluated based on the x-ray spectra produced by a Mo/Mo, Mo/Rh and W/Rh target/filter, for 25, 30 and 35 kV tube voltages and scattering angles between 30 and 165 degrees. Three mammography phantoms were irradiated and the scattered radiation was measured with a CdZnTe detector. The primary x-ray spectra were computed with a semiempirical model based on the air kerma and HVL measured with an ionization chamber. The results point out that the scatter fraction values are higher for W/Rh than for Mo/Mo and Mo/Rh, although the primary and scattered air kerma are lower for W/Rh than for Mo/Mo and Mo/Rh target/filter combinations. The scatter fractions computed in this work were applied in a shielding design calculation in order to evaluate shielding requirements for each of these target/filter combinations. Besides, shielding requirements have been evaluated converting the scattered air kerma from mGy/week to mSv/week adopting initially a conversion coefficient from air kerma to effective dose as 1 Sv/Gy and then a mean conversion coefficient specific for the x-ray beam considered. Results show that the thickest barrier should be provided for Mo/Mo target/filter combination. They also point out that the use of the conversion coefficient from air kerma to effective dose as 1 Sv/Gy is conservatively high in the mammography energy range and overestimate the barrier thickness. (c) 2008 American Association of Physicists in Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Far-infrared transitions in polar semiconductors are known to be affected by the presence of shallow donor impurities, external magnetic fields and the electron-LO-phonon interaction. We calculate the magnetodonor states in indium phosphide by a diagonalization procedure, and introduce the electron-phonon interaction by the Frohlich term. The main effects of this perturbation are calculated by a multi-level version of the Wigner-Brillouin theory. We determine the transition energies, from the ground state to excited states, and find good qualitative agreement with recently reported absorption-spectroscopy measurements in the 100-800 cm(-1) range, with applied magnetic fields up to 30 T. Our calculations suggest that experimental peak splittings in the 400-450 cm(-1) range are due to the electron-phonon interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a new wavelet-based algorithm for low-cost computation of the cepstrum. It can be used for real time precise pitch determination in automatic speech and speaker recognition systems. Many wavelet families are examined to determine the one that works best. The results confirm the efficacy and accuracy of the proposed technique for pitch extraction. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to determine the influence of pedal rate on the precision and quantification of the accumulated oxygen deficit (AOD). Eight trained male triathletes completed a lactate threshold test, VO2 peak test, 10 x 3 min submaximal exercise bouts and a high-intensity exercise bout, all performed at 80 and 120 rev/min. For both pedal rates the intensities for the sub-maximal and high-intensity tests were relative to the lactate threshold and VO2 peak work rates. The VO2-power regressions were calculated using 5 intensities from above the lactate threshold combined with a y intercept value with VO2 measured after 3 min of exercise. For the 120 compared to the 80 rev/min tests, the lactate threshold work rate (255±13 versus 276±47 Watts) (p<0.01) and VO2 peak work rate (352±17 versus 382±20, Watts) (p<0.05) were lower at 120 rev/m. Conversely, the VO2 peak and the VO2 measured during the exhaustive exercise were the same for both pedal rates (p>0.05). Using linear regression modelling the slope of the VO2-power regression (0.0112 versus 0.010 L/Watt) (p<0.01), the estimated total energy demand (ETED) (5.13±0.75 versus 4.89±0.88 L/min) and the AOD (4.27±0.94 versus 3.66±1.25 L) (p<0.05) were greater at 120 rev/m. However, the 95% confidence interval for the ETED and the standard error of the predicted value were the same for both pedal rates (p>0.05). Our results demonstrate that pedal rate effects the size but not the precision of the calculated AOD and should therefore be considered when developing an AOD protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sporting terms have been used as metaphor and analogy to describe and prescribe life experiences. It has been suggested that the use of sport terminology can assist in the general understanding of complex terms and situations, however, the use of sport as metaphor and analogy for many aspects of social understanding can have negative consequences. The analogy of sport and war seems to be particularly prevalent within football, irrespective of the code or culture in which it is played. This article demonstrates the popular understanding of Australian Rules ‘football as war’ through two complementary studies. The first study investigates the representation of Australian Rules football as war, specifically through the analysis of both images and text on the front covers of the sport ‘lift-out’ sections of two prominent Melbourne newspapers, The Herald Sun and The Age. The second study examines whether people interpret non-war-like images of Australian Rules football in war-like terms. Forty-five undergraduate sport marketing and management students were asked to write about one of four different images of football players and coaches interacting, which revealed that football is understood as war. Further, when prompted by an image of football players and coaches interacting, people in this study interpreted the interactions as consistently war-like. Coaches were portrayed as militaristic generals and the athletes as soldiers. Implications for management, education and practice are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differential optical flow methods are widely used within the computer vision community. They are classified as being either local, as in the Lucas-Kanade method, or global, as in the Horn-Schunck technique. As the physical dynamics of an object is inherently coupled into the behavior of its image in the video stream, in this paper, we use such dynamic parameter information in calculating optical flow when tracking a moving object using a video stream. Indeed, we use a modified error function in the minimization that contains physical parameter information. Further, the refined estimates of optical flow is used for better estimation of the physical parameters of the object in the simultaneous estimation of optical flow and object state(SEOS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A feasibility study for handling the partial recrystallisation in multi-pass hot deformation where the heterogeneity of microstructure of deformed austenite is inherently accompanied is presented. The proposed model is based on modification of the conventional model in which the microstructure of deformed austenite at each pass is simply taken as being homogeneous during the multi-pass deformation. The usefulness of the modified model has been demonstrated by applying it to a four-pass oval–round (or round–oval) rod rolling sequence. The recrystallised fraction, austenite grain size (AGS) and mean flow stress at each pass computed from the modified model has been compared with those from the conventional model. The result showed that the recrystallisation behaviour and evolution of AGS at a given pass were dependent on the modelling method of the partial recrystallisation in the multi-pass rolling for the case studied. As the rolling speed increased, the difference between the mean flow stresses calculated by the conventional model and the proposed model was gradually larger in accordance with the contribution of partial recrystallisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an apparent gap between the LCA or other assessment's outcomes and its effective application in the decision making process. It is needed to provide to the decision makers a simple, less human interfered mechanism that integrates all the key criteria (environmental, economic, technical and safety etc.). The proposed index: Interlink Decision Making Index (IDMI) has all these features: simple, interlink (all criteria) and automatically and quantified influence of critical criteria (ie. no human weighting needed) and is able to assist the multi-criteria decision making for sustainability based on the outcomes of specific assessments (eg. LCA, BIA etc.). The index represents a pure numerical value and does not necessarily have any physical meanings, but it reflects the total merits of a particular option once the normal decision making criteria and (up to two) critical criteria (Ce) have been chosen. Then, without arbitrarily weighting process, the comparison and selection of the best possible option, ie. decision can be made based on the derived IDMI results. Two hypothetical examples are presented in the part 2 of the paper to demonstrate the application of the IDMI concept and it's differences with the traditional "tabular method" in the decision making process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to calculate drug dosages correctly is an essential skill for registered nurses to possess. Performing drug calculations accurately is not a skill that new graduates have the luxury of developing over time. Drug errors are in many instances directly related to either the administration of an incorrect dose or incorrect infusion rate (Gladstone, 1995) caused by calculation errors. A strategy for implementing drug calculation skills into our new under graduate nursing curriculum was initiated to assist students in developing proficiency in drug calculations. The aim of this program is to promote the development of calculation skills in undergraduate nursing students, rather than simply assessing their skills.