899 resultados para air-lift pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid advection of extremely warm and dry air is studied during two events in the Mediterranean Basin. On 27 August 2010 a rapid advection of extremely warm and dry air affected the northeast Iberian Peninsula during a few hours. At the Barcelona city center, the temperature reached 39.3 ° C, which is the maximum temperature value recorded during 230 yr of daily data series. On 23 March 2008 a rapid increase of temperature and drop of relative humidity were recorded for a few hours in Heraklion (Crete). During the morning on that day, the recorded temperature reached 34 °C for several hours on the northern coastline of this island.According to the World Meteorological Organization none of these events can be classified as a heat wave, which requires at least two days of abnormally high temperatures; neither are they a heat burst as defined by the American Meteorological Society, where abnormal temperatures take place during a few minutes. For this reason, we suggest naming this type of event flash heat. By using data from automatic weather stations in the Barcelona and Heraklion area and WRF mesoscale numerical simulations, these events are analyzed. Additionally, the primary risks and possible impacts on several fields are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iowa's secondary roads contain nearly 15,000 bridges which are less than 40 feet (12 m) in length. Many of these bridges were built several decades ago and need to be replaced. Box culvert construction has proven to be an adequate bridge replacement technique. Recently a new bridge replacement alternative, called the Air-0-Form method, has emerged which has several potential advantages over box culvert construction. This new technique uses inflated balloons as the interior form in the construction of an arch culvert. The objective of research project HR-314 was to construct an air formed arch culvert to determine the applicability of the Air-O-Form technique as a county bridge replacement alternative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A noise wall was investigated to assess its effect on snow accumulation and air quality. Wind tunnel studies were undertaken to evaluate (a) possible snow accumulations and (b) the dispersion of particulate concentrations (dust, smoke, and lead particles) and carbon monoxide. Full-scale monitoring of particulate concentrations and carbon monoxide was performed both before and after the noise wall was constructed. The wind tunnel experiments for snow accumulation were conducted on a model wall located in a flat, unobstructed area. A separated flow zone existed upwind of the wall and snow immediately began to accumulate over most of the separated zone. Having the noise wall in an aerodynamically rough area, such as in an urban area as this one was, substantially decreased the amount of snow collected, compared with in the wind tunnel studies, because of turbulence reducing the separation zone. The snow accumulation has not been significantly greater with the noise wall in place than it was before construction and has proven to be of no concern to date. Monitoring for particulate concentrations has shown that the noise wall has had a beneficial effect because the amount of material collected was reduced. With the noise wall in place, monitoring for carbon monoxide has indicated that (a) for equivalent emissions under conditions of high atmospheric stability and low wind speeds, the carbon monoxide levels would be lower; and (b) under conditions of low atmospheric stability and high wind speeds, the carbon monoxide levels would be higher than expected without the wall in place.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Department of Public Health (IDPH), Hazardous Waste Site Health Assessment Program was asked by the US Environmental Protection Agency (EPA) to review a round of air sampling data. The air data was collected and analyzed during a removal action at the Le Mars Coal Gas Site in Le Mars, Iowa. EPA asked IDPH to determine from the air data if additional monitoring is necessary throughout the removal action to protect nearby residents from exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les collectivités d'enfants, comme les écoles, mettent en contact de nombreuses personnes dans un espace restreint. Cette proximité peut favoriser la transmission croisée de micro-organismes infectieux. Les épidémies de varicelle, conjonctivite virale, rougeole et gastro-entérite, et la transmission de parasites comme les poux sont fréquentes dans les établissements scolaires et affectent les enfants et le personnel encadrant dont les enseignants. Ce risque professionnel est souvent négligé car considéré comme inévitable. À côté des risques infectieux, d'autres risques liés à des micro-organismes environnementaux et à leurs constituants comme les endotoxines peuvent exister. Ainsi, des études ont montré que les concentrations aéroportées de particules à l'intérieur des classes d'école étaient plus élevées qu'à l'extérieur (1) et que leur composition chimique était différente (2). Plusieurs études épidémiologiques ont montré un lien clair entre l'exposition à des particules et différents problèmes de santé notamment des problèmes respiratoires et cardiaques. Cette exposition à des particules en suspension dans l'air peut avoir des effets toxiques sur les cellules épithéliales des voies respiratoires. Deux études récentes menées dans des écoles et portant sur les particules aéroportées sont analysées ci-dessous. La première étude a évalué les effets biologiques in vitro de particules collectées dans des classes d'écoles en Allemagne et la seconde étude a mesuré les concentrations aéroportées de différents indicateurs de la qualité de l'air dont les micro-organismes dans des écoles au Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Determining a specific death cause may facilitate individualized therapy in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) decreased mortality in the Cardiac Resynchronization in Heart Failure trial by reducing pump failure and sudden cardiac death (SCD). This study analyzes predictors of specific causes of death. METHODS AND RESULTS: Univariate and multivariate analyses used 8 baseline and 3-month post-randomization variables to predict pump failure and SCD (categorized as "definite," "probable," and "possible"). Of 255 deaths, 197 were cardiovascular. There were 71 SCDs with a risk reduction by CRT of 0.47 (95% confidence interval 0.29-0.76; P = .002) with similar reductions in SCD classified as definite, probable, and possible. Univariate SCD predictors were 3-month HF status (mitral regurgitation [MR] severity, plasma brain natriuretic peptide [BNP], end-diastolic volume, and systolic blood pressure), whereas randomization to CRT decreased risk. Multivariate SCD predictors were randomization to CRT 0.56 (0.53-0.96, P = .035) and 3-month MR severity 1.82 (1.77-2.60, P = .0012). Univariate pump failure death predictors related to baseline HF state (quality of life score, interventricular mechanical delay, end-diastolic volume, plasma BNP, MR severity, and systolic pressure), whereas randomization to CRT and nonischemic cardiomyopathy decreased risk; multivariate predictors of pump failure death were baseline plasma BNP and systolic pressure and randomization to CRT. CONCLUSION: CRT decreased SCD in patients with systolic HF and ventricular dyssynchrony. SCD risk was increased with increased severity of MR (including the 3-month value for MR as a time-dependent covariate) and reduced by randomization to CRT. HF death was increased related to the level of systolic blood pressure, log BNP, and randomization to CRT. These results emphasize the importance and interdependence of HF severity to mortality from pump failure and SCD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Some patients with a phenotypic appearance of eosinophilic oesophagitis (EoE) respond histologically to PPI, and are described as having PPI-responsive oesophageal eosinophilia (PPI-REE). It is unclear if PPI-REE is a GERD-related phenomenon, a subtype of EoE, or a completely unique entity. AIM: To compare demographic, clinical and histological features of EoE and PPI-REE. METHODS: Two databases were reviewed from the Walter Reed and Swiss EoE databases. Patients were stratified into two groups, EoE and PPI-REE, based on recent EoE consensus guidelines. Response to PPI was defined as achieving less than 15 eos/hpf and a 50% decrease from baseline following at least a 6-week course of treatment. RESULTS: One hundred and three patients were identified (63 EoE and 40 PPI-REE; mean age 40.2 years, 75% male and 89% Caucasian). The two cohorts had similar dysphagia (97% vs. 100%, P = 0.520), food impaction (43% vs. 35%, P = 0.536), and heartburn (33% vs. 32%, P = 1.000) and a similar duration of symptoms (6.0 years vs. 5.8 years, P = 0.850). Endoscopic features were also similar between EoE and PPI-REE; rings (68% vs. 68%, P = 1.000), furrows (70% vs. 70%, P = 1.000), plaques (19% vs. 10%, P = 0.272), strictures (49% vs. 30%, P = 0.066). EoE and PPI-REE were similar in the number of proximal (39 eos/hpf vs. 38 eos/hpf, P = 0.919) and distal eosinophils (50 vs. 43 eos/hpf, P = 0.285). CONCLUSIONS: EoE and PPI-responsive oesophageal eosinophilia are similar in clinical, histological and endoscopic features and therefore are indistinguishable without a PPI trial. Further studies are needed to determine why a subset of patients with oesophageal eosinophilia respond to PPI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integration of electric motors and industrial appliances such as pumps, fans, and compressors is rapidly increasing. For instance, the integration of an electric motor and a centrifugal pump provides cost savings and improved performance characteristics. Material cost savings are achieved when an electric motor is integrated into the shaft of a centrifugal pump, and the motor utilizes the bearings of the pump. This arrangement leads to a smaller configuration that occupies less floor space. The performance characteristics of a pump drive can be improved by using the variable-speed technology. This enables the full speed control of the drive and the absence of a mechanical gearbox and couplers. When using rotational speeds higher than those that can be directly achieved by the network frequency the structure of the rotor has to be mechanically durable. In this thesis the performance characteristics of an axial-flux solid-rotor-core induction motor are determined. The motor studied is a one-rotor-one-stator axial-flux induction motor, and thus, there is only one air-gap between the rotor and the stator. The motor was designed for higher rotational speeds, and therefore a good mechanical strength of the solid-rotor-core rotor is required to withstand the mechanical stresses. The construction of the rotor and the high rotational speeds together produce a feature, which is not typical of traditional induction motors: the dominating loss component of the motor is the rotor eddy current loss. In the case of a typical industrial induction motor instead the dominating loss component is the stator copper loss. In this thesis, several methods to decrease the rotor eddy current losses in the case of axial-flux induction motors are presented. A prototype motor with 45 kW output power at 6000 min-1 was designed and constructed for ascertaining the results obtained from the numerical FEM calculations. In general, this thesis concentrates on the methods for improving the electromagnetic properties of an axial-flux solid-rotor-core induction motor and examines the methods for decreasing the harmonic eddy currents of the rotor. The target is to improve the efficiency of the motor and to reach the efficiency standard of the present-day industrial induction motors equipped with laminated rotors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integrated system of design for manufacturing and assembly (DFMA) and internet based collaborative design are presented to support product design, manufacturing process, and assembly planning for axial eccentric oil-pump design. The presented system manages and schedules group oriented collaborative activities. The design guidelines of internet based collaborative design & DFMA are expressed. The components and the manufacturing stages of axial eccentric oil-pump are expressed in detail. The file formats of the presented system include the data types of collaborative design of the product, assembly design, assembly planning and assembly system design. Product design and assembly planning can be operated synchronously and intelligently and they are integrated under the condition of internet based collaborative design and DFMA. The technologies of collaborative modelling, collaborative manufacturing, and internet based collaborative assembly for the specific pump construction are developed. A seven-security level is presented to ensure the security of the internet based collaborative design system.