895 resultados para Variable head


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Meta-analyses are considered as an important pillar of evidence-based medicine. The aim of this review is to describe the main principles of a meta-analysis and to use examples of head and neck oncology to demonstrate their clinical impact and methodological interest. The major role of individual patient data is outlined, as well as the superiority of individual patient data over meta-analyses based on published summary data. The major clinical breakthrough of head and neck meta-analyses are summarized, regarding concomitant chemotherapy, altered fractionated chemotherapy, new regimens of induction chemotherapy or the use of radioprotectants. Recent methodological developments are described, including network meta-analyses, the validation of surrogate markers. Lastly, the future of meta-analyses is discussed in the context of personalized medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Evidence for the possible effect of vitamin E on head and neck cancers (HNCs) is limited. METHODS: We used individual-level pooled data from 10 case-control studies (5959 cases and 12 248 controls) participating in the International Head and Neck Cancer Epidemiology (INHANCE) consortium to assess the association between vitamin E intake from natural sources and cancer of the oral cavity/pharynx and larynx. Adjusted odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using unconditional logistic regression models applied to quintile categories of nonalcohol energy-adjusted vitamin E intake. RESULTS: Intake of vitamin E was inversely related to oral/pharyngeal cancer (OR for the fifth vs the first quintile category=0.59, 95% CI: 0.49-0.71; P for trend <0.001) and to laryngeal cancer (OR=0.67, 95% CI: 0.54-0.83, P for trend <0.001). There was, however, appreciable heterogeneity of the estimated effect across studies for oral/pharyngeal cancer. Inverse associations were generally observed for the anatomical subsites of oral and pharyngeal cancer and within covariate strata for both sites. CONCLUSION: Our findings suggest that greater vitamin E intake from foods may lower HNC risk, although we were not able to explain the heterogeneity observed across studies or rule out certain sources of bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La publicación en 1992 de Nubosidad variable supuso la reanudación de la actividad novelesca de Carmen Martín Gaite, después de catorce arios dedicados al ensayo y a la historia. En esta obra, el «credo» literario de la novelista no ha variado sustancialmente en relación a otras como Ritmo lento, Retahilas o El cuarto de atrás, pero se ha visto enriquecido con una técnica que acota y fija de forma maestra todo el mundo de significaciones que se proyecta, y que podemos conceptualizar como el flirteo de la autora con la introspección, el recuerdo, y los antojos frente al tiempo pasado de una memoria vulnerable y resbaladiza. La perspectiva narrativa se revela, en este sentido, como el apoyo básico del andamiaje material de la obra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suihku/viira-nopeussuhde on perälaatikon huulisuihkun ja viiran välinen nopeusero. Se vaikuttaa suuresti paperin ja kartongin loppuominaisuuksiin, kuten formaatioon sekä kuituorientaatioon ja näin ollen paperin lujuusominaisuuksiin. Tämän johdosta on erityisen tärkeää tietää todellinen suihku/viira-nopeussuhde paperin- ja kartonginvalmistuksessa. Perinteinen suihku/viira-nopeussuhteen määritysmenetelmä perustuu perälaatikon kokonaispaineeseen. Tällä menetelmällä kuitenkin todellinen huulisuihkun nopeus saattaa usein jäädä tietämättä johtuen mahdollisesta virheellisestä painemittarin kalibroinnista sekä laskuyhtälön epätarkkuuksista. Tämän johdosta on kehitetty useita reaaliaikaisia huulisuihkun mittausmenetelmiä. Perälaatikon parametrien optimaaliset asetukset ovat mahdollista määrittää ja ylläpitää huulisuihkun nopeuden “on-line” määrityksellä. Perälaatikon parametrejä ovat mm. huulisuihku, huuliaukon korkeusprofiili, reunavirtaukset ja syöttövirtauksen tasaisuus. Huulisuihkun nopeuden on-line mittauksella paljastuu myös muita perälaatikon ongelmakohtia, kuten mekaaniset viat, joita on perinteisesti tutkittu aikaa vievillä paperin ja kartongin lopputuoteanalyyseillä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SCOPE: Only a few studies analyzed the role of allium vegetables with reference to head and neck cancers (HNC), with mixed results. We investigated the potential favorable role of garlic and onion within the International Head and Neck Cancer Epidemiology (INHANCE) Consortium. METHODS AND RESULTS: We analyzed pooled individual-level data from eight case-control studies, including 4590 cases and 7082 controls. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between garlic and onion intakes and HNC risk. Compared with no or low garlic use, the ORs of HNC were 0.95 (95% CI 0.71-1.27) for intermediate and 0.74 (95% CI 0.55-0.99) for high garlic use (p for trend = 0.02). The ORs of HNC for increasing categories of onion intake were 0.91 (95% CI 0.68-1.21) for >1 to ≤3 portions per week, and 0.83 (95% CI 0.60-1.13) for >3 portions per week (p for trend = 0.02), as compared to <1 portion per week. We found an inverse association between high onion intake and laryngeal cancer risk (OR = 0.69; 95% CI 0.54-0.88), but no significant association for other subsites. CONCLUSIONS: The results of this pooled-analysis support a possible moderate inverse association between garlic and onion intake and HNC risk. This article is protected by copyright. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2008 the regional government of Catalonia (Spain) reduced the maximum speed limit on several stretches of congested urban motorway in the Barcelona metropolitan area to 80 km/h, while in 2009 it introduced a variable speed system on other stretches of its metropolitan motorways. We use the differences-in-differences method, which enables a policy impact to be measured under specific conditions, to assess the impact of these policies on emissions of NOx and PM10. Empirical estimation indicate that reducing the speed limit to 80 km h-1 causes a 1.7 to 3.2% increase in NOx and 5.3 to 5.9% in PM10. By contrast, the variable speed policy reduced NOx and PM10 pollution by 7.7 to 17.1% and 14.5 to 17.3%. As such, a variable speed policy appears to be a more effective environmental policy than reducing the speed limit to a maximum of 80 km/h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is growing interest in the association of radiotherapy and immunotherapy for the treatment of solid tumors. Here, we report an extremely effective combination of local irradiation (IR) and Shiga Toxin B (STxB)-based human papillomavirus (HPV) vaccination for the treatment of HPV-associated head and neck squamous cell carcinoma (HNSCC). The efficacy of the irradiation and vaccine association was tested using a model of HNSCC obtained by grafting TC-1/luciferase cells at a submucosal site of the inner lip of immunocompetent mice. Irradiation and the STxB-E7 vaccine acted synergistically with both single and fractionated irradiation schemes, resulting in complete tumor clearance in the majority of the treated mice. A dose threshold of 7.5 Gy was required to elicit the dramatic antitumor response. The combined treatment induced high levels of tumor-infiltrating, antigen-specific CD8(+) T cells, which were required to trigger the antitumor activity. Treatment with STxB-E7 and irradiation induced CD8(+) T-cell memory, which was sufficient to exert complete antitumor responses in both local recurrences and distant metastases. We also report for the first time that a combination therapy based on local irradiation and vaccination induces an increased pericyte coverage (as shown by αSMA and NG2 staining) and ICAM-1 expression on vessels. This was associated with enhanced intratumor vascular permeability that correlated with the antitumor response, suggesting that the combination therapy could also act through an increased accessibility for immune cells. The combination strategy proposed here offers a promising approach that could potentially be transferred into early-phase clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Epidemiological data on HNC are often reported aggregated despite their anatomical and histological heterogeneity. In Germany, few studies have analyzed incidence and mortality trends separately for specific anatomic sites. Furthermore, little is known about whether the incidence of HPV-associated tumour entities of the head and neck region has increased. METHODS: Based on cancer registry data from Rhineland-Palatinate from 2000 to 2009, age-standardized incidence and mortality rates were calculated for all HNC sites and localisation groups that might be HPV-associated according to the literature. Trends were analyzed by Joinpoint regression and reported as the annual percentage change (APC). RESULTS: Throughout the study period, 8 055 incident cases and 3 177 deaths were identified. The incidence rates of overall HNC increased among women (APC:+2.2%) and declined slightly among men (- 0.9%). Significantly increasing incidence rates among women were seen for tumours of the oral cavity (+2.7%) and the oropharynx (+3.6%). Among men, a significant decrease in incidence rates for tumours of the hypopharynx (-3.4%) and the larynx (-2.7%) are noteworthy. Cancers at HPV-associated sites showed increased incidence rates in men (+3.3%) and women (+4.3%). A decrease in mortality was found for tumours of the larynx in both sexes (-5.8% men,-9.1% women). CONCLUSIONS: A detailed analysis by localisation of HNC showed significant and often opposing trends for men and women regarding incidence and mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

UNLABELLED: We compared the HIV-1-specific cellular and humoral immune responses elicited in rhesus macaques immunized with two poxvirus vectors (NYVAC and ALVAC) expressing the same HIV-1 antigens from clade C, Env gp140 as a trimeric cell-released protein and a Gag-Pol-Nef polyprotein as Gag-induced virus-like particles (VLPs) (referred to as NYVAC-C and ALVAC-C). The immunization protocol consisted of two doses of the corresponding poxvirus vector plus two doses of a combination of the poxvirus vector and a purified HIV-1 gp120 protein from clade C. This immunogenicity profile was also compared to that elicited by vaccine regimens consisting of two doses of the ALVAC vector expressing HIV-1 antigens from clades B/E (ALVAC-vCP1521) plus two doses of a combination of ALVAC-vCP1521 and HIV-1 gp120 protein from clades B/E (similar to the RV144 trial regimen) or clade C. The results showed that immunization of macaques with NYVAC-C stimulated at different times more potent HIV-1-specific CD4(+) T-cell responses and induced a trend toward higher-magnitude HIV-1-specific CD8(+) T-cell immune responses than did ALVAC-C. Furthermore, NYVAC-C induced a trend toward higher levels of binding IgG antibodies against clade C HIV-1 gp140, gp120, or murine leukemia virus (MuLV) gp70-scaffolded V1/V2 and toward best cross-clade-binding IgG responses against HIV-1 gp140 from clades A, B, and group M consensus, than did ALVAC-C. Of the linear binding IgG responses, most were directed against the V3 loop in all immunization groups. Additionally, NYVAC-C and ALVAC-C also induced similar levels of HIV-1-neutralizing antibodies and antibody-dependent cellular cytotoxicity (ADCC) responses. Interestingly, binding IgA antibody levels against HIV-1 gp120 or MuLV gp70-scaffolded V1/V2 were absent or very low in all immunization groups. Overall, these results provide a comprehensive survey of the immunogenicity of NYVAC versus ALVAC expressing HIV-1 antigens in nonhuman primates and indicate that NYVAC may represent an alternative candidate to ALVAC in the development of a future HIV-1 vaccine. IMPORTANCE: The finding of a safe and effective HIV/AIDS vaccine immunogen is one of the main research priorities. Here, we generated two poxvirus-based HIV vaccine candidates (NYVAC and ALVAC vectors) expressing the same clade C HIV-1 antigens in separate vectors, and we analyzed in nonhuman primates their immunogenicity profiles. The results showed that immunization with NYVAC-C induced a trend toward higher HIV-1-specific cellular and humoral immune responses than did ALVAC-C, indicating that this new NYVAC vector could be a novel optimized HIV/AIDS vaccine candidate for human clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the world’s energy demand is increasing, a durable solution to control it is to improve the energy efficiency of the processes. It has been estimated that pumping applications have a significant potential for energy savings trough equipment or control system changes. For many pumping application the use of a variable speed drive as a process control element is the most energy efficient solution. The main target of this study is to examine the energy efficiency of a drive system that moves the pump. In a larger scale the purpose of this study is to examine how the different manufacturers’ variable speed drives are functioning as a control device of a pumping process. The idea is to compare the drives from a normal pump user’s point of view. The things that are mattering for the pump user are the efficiency gained in the process and the easiness of the use of the VSD. So some thought is given also on valuating the user-friendliness of the VSDs. The VSDs are compared to each other also on the basis of their life cycle energy costs in different kind of pumping cases. The comparison is made between ACS800 from ABB, VLT AQUA Drive from Danfoss, NX-drive from Vacon and Micromaster 430 from Siemens. The efficiencies are measured in power electronics laboratory in the Lappeenranta University of Technology with a system that consists of a variable speed drive, an induction motor with dc-machine, two power analyzers and a torque transducer. The efficiencies are measured as a function of a load at different frequencies. According to measurement results the differences between the measured system efficiencies on the actual working area of pumping are on average few percent units. When examining efficiencies at the whole range of different loads and frequencies, the differences get bigger. At low frequencies and loads the differences between the most efficient and the least efficient systems are at the most about ten percent units. At the most of the tested points ABB’s drive seem to have slightly better efficiencies than the other drives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have identified the rivalry among technological platforms as one of the main driving forces of broadband services penetration. This paper draws on data from the Spanish market between 2005 and 2011 to estimate the main determinants of broadband prices. Controlling for broadband tariffs features and network variables, we examine the impact of the different modes of competition on prices. We find that inter-platform competition has no significant effects over prices, while intra-platform competition is a key driver of the prices charged in the broadband market. Our analysis suggests that the impact of different types of competition on prices is critically affected by the levels of development of the broadband market achieved by the considered country

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Second mitochondria-derived activator of caspase (SMAC)-mimetics are a new class of targeted drugs that specifically induce apoptotic cancer cell death and block pro-survival signaling by antagonizing selected members of the inhibitor of apoptosis protein (IAP) family. MATERIAL AND METHODS: The present study was designed to investigate the radiosensitizing effect and optimal sequence of administration of the novel SMAC-mimetic Debio 1143 in vitro and in vivo. Apoptosis, alteration of DNA damage repair (DDR), and tumor necrosis factor-alpha (TNF-α) signaling were examined. RESULTS: In vitro, Debio 1143 displayed anti-proliferative activity and enhanced intrinsic radiation sensitivity in 5/6 head and neck squamous cell carcinoma (HNSCC) cell lines in a synergistic manner. In vivo, Debio 1143 dose-dependently radio-sensitized FaDu and SQ20B xenografts, resulting in complete tumor regression in 8/10 FaDu-xenografted mice at the high dose level. At the molecular level, Debio 1143 combined with radiotherapy (RT) induced enhancement of caspase-3 activity, increase in Annexin V-positive cells and karyopyknosis, and increase in TNF-α mRNA levels. Finally, in a neutralization experiment using a TNF-α-blocking antibody and a caspase inhibitor, it was shown that the radiosensitizing effect of Debio 1143 is mediated by caspases and TNF-α. CONCLUSIONS: These results demonstrate that the novel SMAC-mimetic Debio 1143 is a radiosensitizing agent that is worthy of further investigation in clinical trials in combination with radiotherapy.