975 resultados para Total load
Resumo:
The application of decellularized extracellular matrices to aid tissue regeneration in reconstructive surgery and regenerative medicine has been promising. Several decellularization protocols for removing cellular materials from natural tissues such as heart valves are currently in use. This paper evaluates the feasibility of potential extension of this methodology relative to the desirable properties of load bearing joint tissues such as stiffness, porosity and ability to recover adequately after deformation to facilitate physiological function. Two decellularization protocols, namely: Trypsin and Triton X-100 were evaluated against their effects on bovine articular cartilage, using biomechanical, biochemical and microstructural techniques. These analyses revealed that decellularization with trypsin resulted in severe loss of mechanical stiffness including deleterious collapse of the collagen architecture which in turn significantly compromised the porosity of the construct. In contrast, triton X-100 detergent treatment yielded samples that retain mechanical stiffness relative to that of the normal intact cartilage sample, but the resulting construct contained ruminant cellular constituents. We conclude that both of these common decellularization protocols are inadequate for producing constructs that can serve as effective replacement and scaffolds to regenerate articular joint tissue.
Resumo:
The first total synthesis of (-)-4-thiocyanatoneopupukeanane starting from (R)-carvone has been achieved, establishing the relative as well as absolute structure of the natural product.
Resumo:
In this paper, we present an improved load distribution strategy, for arbitrarily divisible processing loads, to minimize the processing time in a distributed linear network of communicating processors by an efficient utilization of their front-ends. Closed-form solutions are derived, with the processing load originating at the boundary and at the interior of the network, under some important conditions on the arrangement of processors and links in the network. Asymptotic analysis is carried out to explore the ultimate performance limits of such networks. Two important theorems are stated regarding the optimal load sequence and the optimal load origination point. Comparative study of this new strategy with an earlier strategy is also presented.
Resumo:
The first stereoselective total synthesis of (+/-)-allo-cedrol 20, an enantiomer of khusiol and a complex sesquiterpene having a novel tricyclo[5.2.2.0(1,5)]undecane framework, is reported from 8-methoxytricyclo[6.2.2.0(1,6)]dodec-6-en-9-one 6c. The methodology involves preparation of 9-methoxytricyclo[7.2.1.0(1,6)]dodec-6-en-8-one 12 from 6c and its conversion through the compounds 8-benzyloxy-7,7-dimethyl-9-methoxytricyclo[7.2.1.0(1,6)]dodec-5-ene 38, 7-benzyloxy-8-methoxy-2,6,6-trimethyltricyclo[6.2.1.0(1,5)]undecane 48 into 8-methoxy-2,6,6-trimethyltricyclo[6.2.1.0(1,5)]undecan-7-one 49. Wittig reaction of 49 affords the olefin 50 which has been smoothly rearranged into khusione 51. Metal-ammonia reduction of khusione under specific conditions affords (+/-)-allo-cedrol. Thus, bridgehead substitution of a methoxy group by a methyl group is the key reaction in this synthesis. In an alternative strategy, attempted conversion of 8-methoxy-2-methyltricyclo[6.2.1.0(1,5)]undec-5-en-7-one 16 into khusione 37 results in an inseparable mixture of the isomers. A notable observation in this synthesis is the unusual formation of a gamma-alkylated product 27 during Woodward methylation of 16.
Resumo:
Diels-Alder reaction of the dienone 12, obtained by C-alkylation of sodium 2,6-dimethylphenoxide, with acrylonitrile and phenyl vinyl sulfones generate the enynes 14 and 17. Tributyltin radical addition to the terminal acetylene in 14 and 17 lead to the vinylstannanes 15 and 18 via 5-exo trig cyclisation of the resulting vinyl radical, which on oxidative cleavage furnishes the isotwistane-diones 16 and 19. Reductive desulfonylation of the diketosulfone 19 furnishes the dione 11, constituting a formal total synthesis of 2-pupukeanone 5 and 2-isocyanopupukeanone 3.
Resumo:
Total tRNAs isolated from chloroplasts and etioplasts of cucumber cotyledons were compared with respect toamino acid acceptance, isoacceptor distribution and extent of modification. Aminoacylation of the tRNAs with nine different amino acids studied indicated that the relative acceptor activities of chloroplast total tRNAs for four amino acids are significantly higher than etioplast total tRNAs. Two dimensional polyacrylamide gel electrophoresis(2D-PAGE) of chloroplast total tRNAs separated at least 32 spots, while approximately 41 spots were resolved from etioplast total tRNAs. Comparison of the reversed-phase chromatography (RPC-5) profiles of chloroplast and etioplast leucyl-, lysyl-, phenylalanyl-, and valyl-tRNA species showed no qualitative differences in the elution profiles. However, leucyl-, lysyl- and valyl-tRNA species showed quantitative differences in the relative amounts of the isoaccepting species present in chloroplasts and etioplasts. The analysis of modified nucleotides of total tRNAs from the two plastid types indicated that total tRNA from etioplasts was undermodified with respect to ribothymidine, isopentenyladenosine/hydroxy-isopentenyladenosine, 1 -methylguanosine and 2-o-methylguanosine. This indicates that illumination may cause de novo synthesis of chloroplast tRNAmodifying enzymes encoded for by nuclear genes leading to the formation of highly modified tRNAs in chloroplasts. Based on these results, we speculate that the observed decrease in levels of aminoacylation, variations in the relative amounts of certain isoacceptors, and differences in the electrophoretic mobilities of some extra tRNA spots in the etioplast total tRNAs as compared to chloroplast total tRNAs could be due to some partially undermodified etioplast tRNAs. Taken together, the data suggested that the light-induced transformation of etioplasts into chloroplasts is accompanied by increases in the relative levels of some functional chloroplast tRNAs by post transcriptional nucleotide modifications.
Resumo:
The present work focuses on simulation of nonlinear mechanical behaviors of adhesively bonded DLS (double lap shear) joints for variable extension rates and temperatures using the implicit ABAQUS solver. Load-displacement curves of DLS joints at nine combinations of extension rates and environmental temperatures are initially obtained by conducting tensile tests in a UTM. The joint specimens are made from dual phase (DP) steel coupons bonded with a rubber-toughened adhesive. It is shown that the shell-solid model of a DLS joint, in which substrates are modeled with shell elements and adhesive with solid elements, can effectively predict the mechanical behavior of the joint. Exponent Drucker-Prager or Von Mises yield criterion together with nonlinear isotropic hardening is used for the simulation of DLS joint tests. It has been found that at a low temperature (-20 degrees C), both Von Mises and exponent Drucker-Prager criteria give close prediction of experimental load-extension curves. However. at a high temperature (82 degrees C), Von Mises condition tends to yield a perceptibly softer joint behavior, while the corresponding response obtained using exponent Drucker-Prager criterion is much closer to the experimental load-displacement curve.
Resumo:
First enantiospecific total synthesis of optical antipode of the sesquiterpene 10,11-epoxythapsan-10-ol has been described. (R)-Carvone has been employed as the chiral starting material and a combination of intramolecular alkylation and Criegee fragmentation are employed for intramolecular stereospecific transfer of the chirality. An intramolecular diazoketone cyclopropanation and regioselective cyclopropane ring cleavage reactions have been employed for the creation of the three requisite contiguous quaternary carbon atoms.
Resumo:
Current source inverter (CSI) is an attractive solution in high-power drives. The conventional gate turn-off thyristor (GTO) based CSI-fed induction motor drives suffer from drawbacks such as low-frequency torque pulsation, harmonic heating, and unstable operation at low-speed ranges. These drawbacks can be overcome by connecting a current-controlled voltage source inverter (VSI) across the motor terminal replacing the bulky ac capacitors. The VSI provides the harmonic currents, which results in sinusoidal motor voltage and current even with the CSI switching at fundamental frequency. This paper proposes a CSI-fed induction motor drive scheme where GTOs are replaced by thyristors in the CSI without any external circuit to assist the turning off of the thyristors. Here, the current-controlled VSI, connected in shunt, is designed to supply the volt ampere reactive requirement of the induction motor, and the CSI is made to operate in leading power factor mode such that the thyristors in the CSI are autosequentially turned off. The resulting drive will be able to feed medium-voltage, high-power induction motors directly. A sensorless vector-controlled CSI drive based on the proposed configuration is developed. The experimental results from a 5 hp prototype are presented. Experimental results show that the proposed drive has stable operation throughout the operating range of speeds.
Resumo:
Coronary calcium scoring (CCS) has been a topic of great interest lately. In a large population-based study comprising 6,722 patients, Detrano et al. (1) have effectively shown that CCS can be a strong predictor of incident coronary heart disease among different racial groups. Henneman et al. (2) have, however, reported that CCS does not reliably exclude the presence of (significant) atherosclerosis. This topic is quite controversial as there is significant evidence from Detrano's work that higher CCS is associated with an increased risk of acute coronary events. We think that the location of calcium within the coronary arteries should also be considered. Li et al. (3,4) have shown that the position of the calcium in the plaque is a better determinant of plaque vulnerability than the total calcium load. Using a biomechanical model, predicted maximum stress was found to increase by 47.5% when calcium deposits were located in the thin fibrous cap. The presence of calcium deposits in the lipid core or remote from the fibrous cap resulted in no increase in maximum stress. It was also noted that the presence of calcification within the lipid core may even stabilize the plaque. Integration of calcium location in CCS will, therefore, enable better assessment of severity of atherosclerosis and prediction of future cardiovascular events.
Resumo:
The application of multilevel control strategies for load-frequency control of interconnected power systems is assuming importance. A large multiarea power system may be viewed as an interconnection of several lower-order subsystems, with possible change of interconnection pattern during operation. The solution of the control problem involves the design of a set of local optimal controllers for the individual areas, in a completely decentralised environment, plus a global controller to provide the corrective signal to account for interconnection effects. A global controller, based on the least-square-error principle suggested by Siljak and Sundareshan, has been applied for the LFC problem. A more recent work utilises certain possible beneficial aspects of interconnection to permit more desirable system performances. The paper reports the application of the latter strategy to LFC of a two-area power system. The power-system model studied includes the effects of excitation system and governor controls. A comparison of the two strategies is also made.
Resumo:
There are numerous load estimation methods available, some of which are captured in various online tools. However, most estimators are subject to large biases statistically, and their associated uncertainties are often not reported. This makes interpretation difficult and the estimation of trends or determination of optimal sampling regimes impossible to assess. In this paper, we first propose two indices for measuring the extent of sampling bias, and then provide steps for obtaining reliable load estimates by minimizing the biases and making use of possible predictive variables. The load estimation procedure can be summarized by the following four steps: - (i) output the flow rates at regular time intervals (e.g. 10 minutes) using a time series model that captures all the peak flows; - (ii) output the predicted flow rates as in (i) at the concentration sampling times, if the corresponding flow rates are not collected; - (iii) establish a predictive model for the concentration data, which incorporates all possible predictor variables and output the predicted concentrations at the regular time intervals as in (i), and; - (iv) obtain the sum of all the products of the predicted flow and the predicted concentration over the regular time intervals to represent an estimate of the load. The key step to this approach is in the development of an appropriate predictive model for concentration. This is achieved using a generalized regression (rating-curve) approach with additional predictors that capture unique features in the flow data, namely the concept of the first flush, the location of the event on the hydrograph (e.g. rise or fall) and cumulative discounted flow. The latter may be thought of as a measure of constituent exhaustion occurring during flood events. The model also has the capacity to accommodate autocorrelation in model errors which are the result of intensive sampling during floods. Incorporating this additional information can significantly improve the predictability of concentration, and ultimately the precision with which the pollutant load is estimated. We also provide a measure of the standard error of the load estimate which incorporates model, spatial and/or temporal errors. This method also has the capacity to incorporate measurement error incurred through the sampling of flow. We illustrate this approach using the concentrations of total suspended sediment (TSS) and nitrogen oxide (NOx) and gauged flow data from the Burdekin River, a catchment delivering to the Great Barrier Reef. The sampling biases for NOx concentrations range from 2 to 10 times indicating severe biases. As we expect, the traditional average and extrapolation methods produce much higher estimates than those when bias in sampling is taken into account.
Resumo:
This paper deals with the optimal load flow problem in a fixed-head hydrothermal electric power system. Equality constraints on the volume of water available for active power generation at the hydro plants as well as inequality constraints on the reactive power generation at the voltage controlled buses are imposed. Conditions for optimal load flow are derived and a successive approximation algorithm for solving the optimal generation schedule is developed. Computer implementation of the algorithm is discussed, and the results obtained from the computer solution of test systems are presented.
Resumo:
To further evaluate the nature of malnutrition, define at-risk groups, and confirm the efficacy of nutritional supplementation on body composition in cystic fibrosis (CF), we have conducted longitudinal and cross-sectional studies of total body potassium (TBK) in 161 unselected CF subjects aged 1 month to 17 years. TBK was determined by measurement of40K in a whole body counter, reflecting body cell mass (BCM), the vital work-performing and growing cellular component of the body. Compared with normal TBK data for age and sex from pooled measurements of 1,629 healthy children aged 1 week to 17 years, CF infants (n = 12) diagnosed by newborn screening were depleted in TBK at diagnosis and showed catch-up with therapy by 1 year; CF children aged 2-17 years (n = 140) showed a tendency for inadequate accretion of TBK (and thus BCM) with increasing age, although the normal correlation between TBK and weight and height was maintained in the majority suggesting a pattern of nutritional stunting of growth; and malnourished CF children (n = 9) showed significant catchup in TBK with long-term nutritional rehabilitation (85-98% of TBK predicted for weight and height). These studies suggest that potentially serious, but possibly correctable deficits, in the growth of the body cell mass as measured by TBK occur commonly in CF. These deficits may be established very early in life and if not corrected lead to progressive nutritional growth retardation with increasing age. © 1989 Raven Press, Ltd., New York.
Resumo:
Land application of piggery effluent (containing urine, faeces, water, and wasted feed) is under close scrutiny as a potential source of water resource contamination with phosphorus (P). This paper investigates two case studies of the impact of long-term piggery effluent-P application to soil. A Natrustalf (Sodosol) at P1 has received a net load of 3700 kg effluent P/ha over 19 years. The Haplustalf (Dermosol) selected (P2) has received a net load of 310 000 kg P/ha over 30 years. Total, bicarbonate extractable, and soluble P forms were determined throughout the soil profiles for paired (irrigated and unirrigated) sites at P1 and P2, as well as P sorption and desorption characteristics. Surface bicarbonate (PB, 0 - 0.05 m depth) and dilute CaCl2 extractable molybdate-reactive P (PC) have been significantly elevated by effluent irrigation (P1: PB unirrigated 23±1, irrigated 290±6; PC unirrigated 0.03±0.00, irrigated 23.9±0.2. P2: PB unirrigated 72±48, irrigated 3950±1960; PC unirrigated 0.7±0.0, irrigated 443±287 mg P/kg; mean±s.d.). Phosphorus enrichment to 1.5 m, detected as PB, was observed at P2. Elevated concentrations of CaCl2 extractable organic P forms (POC; estimated by non-molybdate reactive P in centrifuged supernatants) were observed from the soil surface of P1 to a depth of 0.4 m. Despite the extent of effluent application at both of these sites, only P1 displayed evidence of significant accumulation of POC. The increase in surface soil total P (0 - 0.05 m depth) due to effluent irrigation was much greater than laboratory P sorption (>25 times for P1; >57 times for P2) for a comparable range of final solution concentrations (desorption extracts ranged from 1-5 mg P/L for P1 and 50-80 mg P/L for P2). Precipitation of sparingly soluble P phases was evidenced in the soils of the P2 effluent application area.