991 resultados para Test facilities


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel way of testing exogeneity of an explanatory variable without any parametric assumptions in the presence of a "conditional" instrumental variable. A testable implication is derived that if an explanatory variable is endogenous, the conditional distribution of the outcome given the endogenous variable is not independent of its instrumental variable(s). The test rejects the null hypothesis with probability one if the explanatory variable is endogenous and it detects alternatives converging to the null at a rate n..1=2:We propose a consistent nonparametric bootstrap test to implement this testable implication. We show that the proposed bootstrap test can be asymptotically justi.ed in the sense that it produces asymptotically correct size under the null of exogeneity, and it has unit power asymptotically. Our nonparametric test can be applied to the cases in which the outcome is generated by an additively non-separable structural relation or in which the outcome is discrete, which has not been studied in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two published case reports showed that addition of risperidone (1 and 2 mg/d) to a clozapine treatment resulted in a strong increase of clozapine plasma levels. As clozapine is metabolized by cytochrome P450 isozymes, a study was initiated to assess the in vivo interaction potential of risperidone on various cytochrome P450 isozymes. Eight patients were phenotyped with dextromethorphan (CYP2D6), mephenytoin (CYP2C19), and caffeine (CYP1A2) before and after the introduction of risperidone. Before risperidone, all eight patients were phenotyped as being extensive metabolizers of CYP2D6 and CYP2C19. Risperidone at dosages between 2 and 6 mg/d does not appear to significantly inhibit CYP1A2 and CYP2C19 in vivo (median plasma paraxanthine/caffeine ratios before and after risperidone: 0.65, 0.69; p = 0.89; median urinary (S)/(R) mephenytoin ratios before and after risperidone:0.11, 0.12; p = 0.75). Although dextromethorphan metabolic ratio is significantly increased by risperidone (median urinary dextromethorphan/dextrorphan ratios before and after risperidone: 0.010, 0.018; p = 0.042), risperidone can be considered a weak in vivo CYP2D6 inhibitor, as this increase is modest and none of the eight patients was changed from an extensive to a poor metabolizer. The reported increase of clozapine concentrations by risperidone can therefore not be explained by an inhibition of CYP1A2, CYP2D6, CYP2C19 or by any combination of the three.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper considers the use of artificial regression in calculating different types of score test when the log

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An indirect haemagglutination (IH) test is described for the detection of Clostridium perfringens type A enterotoxin, produced by strains isolated from human cases of food poisoning and from contaminated food. Though no strict relationship could be observed between titers in the IH test and the time it took mice to die from the intravenous inoculation of mice (IIM), results of the supernatants examined by both methods demonstrated that the IH test was more sensitive than the ILM one. No unspecific reaction was obtanined int he IH wirh a negative control and the inhibitions of the IH and IIM tests by specific antiserum against C. perfringens enterotoxin showed that the IH test is very spcific. The IH assay is recommended for its sensitivity and easy performance by less-equipped laboratories, by these and other data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper develops a new test of true versus spurious long memory, based on log-periodogram estimation of the long memory parameter using skip-sampled data. A correction factor is derived to overcome the bias in this estimator due to aliasing. The procedure is designed to be used in the context of a conventional test of significance of the long memory parameter, and composite test procedure described that has the properties of known asymptotic size and consistency. The test is implemented using the bootstrap, with the distribution under the null hypothesis being approximated using a dependent-sample bootstrap technique to approximate short-run dependence following fractional differencing. The properties of the test are investigated in a set of Monte Carlo experiments. The procedure is illustrated by applications to exchange rate volatility and dividend growth series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: The dissemination of palliative care for patients presenting complex chronic diseases at various stages has become an important matter of public health. A death census in Swiss long-term care facilities (LTC) was set up with the aim of monitoring the frequency of selected indicators of palliative care. METHODS: The survey covered 150 LTC facilities (105 nursing homes and 45 home health services), each of which was asked to complete a questionnaire for every non-accidental death over a period of six months. The frequency of 4 selected indicators of palliative care (resort to a specialized palliative care service, the administration of opiates, use of any pain measurement scale or other symptom measurement scale) was monitored in respect of the stages of care and analysed based on gender, age, medical condition and place of residence. RESULTS: Overall, 1200 deaths were reported, 29.1% of which were related to cancer. The frequencies of each indicator varied according to the type of LTC, mostly regarding the administration of opiate. It appeared that the access to palliative care remained associated with cancer, terminal care and partly with age, whereas gender and the presence of mental disorders had no effect on the indicators. In addition, the use of drugs was much more frequent than the other indicators. CONCLUSION: The profile of patients with access to palliative care must become more diversified. Among other recommendations, equal access to opiates in nursing homes and in home health services, palliative care at an earlier stage and the systematic use of symptom management scales when resorting to opiates have to become of prime concern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recent study with 69 Japanese liver transplants treated with tacrolimus found that the MDR13435 C >T polymorphism, but not the MDR12677 G >T polymorphism, was associated with differences in the intestinal expression level of CYP3A4 mRNA. In the present study, over 6 h, we measured the kinetics of a 75 microg oral dose of midazolam, a CYP3A substrate, in 21 healthy subjects genotyped for the MDR13435 C >T and 2677 G >T polymorphism. No statistically significant differences were found in the calculated pharmacokinetic parameters between the three 3435 C >T genotypes (TT, CT and CC group, respectively: Cmax (mean +/- SD: 0.30 +/- 0.08 ng/ml, 0.31 +/- 0.09 ng/ml and 0.31 +/- 0.11 ng/ml; Apparent clearance: 122 +/- 29 l/h, 156 +/- 92 l/h and 111 +/- 35 l/h; t1/2: 1.9 +/- 1.1 h, 1.6 +/- 0.90 h and 1.7 +/- 0.7 h). In addition, the 30-min 1'OH midazolam to midazolam ratio, a marker of CYP3A activity, determined in 74 HIV-positive patients before the introduction of antiretroviral treatment, was not significantly different between the three 3435 C >T genotypes (mean ratio +/- SD: 3.65 +/- 2.24, 4.22 +/- 3.49 and 4.24 +/- 2.03, in the TT, CT and CC groups, respectively). Similarly, no association was found between the MDR12677 G >T polymorphism and CYP3A activity in the healthy subjects or in the HIV-positive patients. The existence of a strong association between the activity of CYP3A and MDR13435 C >T and 2677 G >T polymorphisms appears unlikely, at least in Caucasian populations and/or in the absence of specific environmental factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The latex of Euphorbia splendens var. hislopii, at concentrations between 5 to 12 mg/l, kills 100% of the population of Biomphalaria glabrata in a lentic habitat, after 24 h. The lyophilized latex, stocked for 18 months, killed only 34.2% of the snails, at the concentration of 5 mg/l, and 96.0% at 12 mg/l. No lethal effect was observed among Pomacea haustrum exposed to the same concentrations of the molluscicide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood sampling on filter paper is a current practice seroepidemiological studies by indirect fluorescent antibody test (IFAT). There is, however, scant comparative information about the use of bloodspot eluates for detection of malarial IgG antibodies simultaneously by IFAT and enzyme immunoassay (ELISA). Here we report data obtained by both serological methods done on 219 bloodspot eluate samples collected in a rural community in Brazilian Amazon Basin (Alto Paraíso, Ariquemes municipality) where malaria is endemic. Plasmodium falciparum and P. vivax thick smear antigens were used in the IFAT; a detergent-soluble P. falciparum antigen was prepared for ELISA. Substantial agreement of results (Kappa coefficient k = 0.686) was observed when P. falciparum antigen was used in both tests, and IFAT titers were found to be strongly correlated ELISA antibody units (Spearman correlation coeficient rs = 0.818, p < 0.0001). Only moderate agreement (k = 0.467) between IFAT with P. vivax antigen and ELISA with P. falciparum antigen was observed. Spearman correlation coefficient value between quantitative results (IFAT titers and ELISA antibody units) in this case was numerically lowe (rs = 0.540, p < 0.0001). Our results suggest that, with P. falciparum antigen, both IFAT and ELISA performed on bloodspot eluates are equivalent for seropidemiological purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: The difficulty of identifying the ownership of lost dentures when found is a common and expensive problem in long term care facilities (LTCFs) and hospitals. PURPOSE: The purpose of this study was to evaluate the reliability of using radiofrequency identification (RFID) in the identification of dentures for LTCF residents after 3 and 6 months. MATERIAL AND METHODS: Thirty-eight residents of 2 LTCFs in Switzerland agreed to participate after providing informed consent. The tag was programmed with the family and first names of the participants and then inserted in the dentures. After placement of the tag, the information was read. A second and third assessment to review the functioning of the tag occurred at 3 and 6 months, and defective tags (if present) were reported and replaced. The data were analyzed with descriptive statistics. RESULTS: At the 3-month assessment of 34 residents (63 tags) 1 tag was unreadable and 62 tags (98.2%) were operational. At 6 months, the tags of 27 of the enrolled residents (50 tags) were available for review. No examined tag was defective at this time period. CONCLUSIONS: Within the limits of this study (number of patients, 6-month time span) RFID appears to be a reliable method of tracking and identifying dentures, with only 1 of 65 devices being unreadable at 3 months and 100% of 50 initially placed tags being readable at the end of the trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest project es situa dins del marc del CNM-IMB (CSIC). Consisteix en el disseny d'un sistema de biòpsia mamaria en temps real. Per realitzar aquest sistema s’ha dissenyat una plataforma de lectura, test y caracterització pel ROIC Medipix2 que es basa en el microprocessador LEON3 i és programat sobre una FPGA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The WHO criterion of defering any donation of blood by a confirmed case of malaria for three years after cessation of therapy can not be applied in areas where malaria in endemic. For this reason we developed an immunoenzymatic assay for the detection of plasmodial antigens for blood screening in malararial endemic areas. So, we tested sera from 191 individuals. Among patients with active disease 100% of the cases of Plasmodium falciparum or mixed infections and 91.7% of those with P. vivax were positive for the presence of plasmodial antigens. The lower parasitaemia detected was 0.0003% for P. vivax malária. When the frequency of positive circulating malarial antigens was evaluated among asymptomatic and symptomatic individuals with negative TBS, positive results were found in respectively 38.7% and 17.7% of the individuals studied in the 30 days after confirmed malaria attack. Data provide by these assays have shown that ELISA seemed to be more sensitive than parasitological examination for malaria diagnosis. This test by virtue of its high sensivity and the facilities in processing a large number of specimens, can prove to be useful in endemic areas for the recognition of asymptomatic malaria and screening of blood donors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La dépression majeure est fréquente chez les patients qui consultent un cabinet de médecine générale. Elle reste toutefois difficile à diagnostiquer car elle est souvent masquée par une ou plusieurs plaintes physiques qui sont l'unique motif de consultation. Pour aider le médecin généraliste à démasquer ce trouble, un test de dépistage composé de deux questions a été développé et validé. Ce test indique une probabilité accrue de dépression si le patient répond positivement à au moins une des deux questions suivantes : « Est-ce que, durant le mois qui a précédé, vous vous êtes senti(e) triste, déprimé(e), désespéré(e) ? » et « Durant le mois qui a précédé, avez-vous ressenti un manque d'intérêt et de plaisir dans la plupart des activités que d'habitude vous appréciez ? ». Une troisième question, ajoutée aux deux questions ci-dessus, a été proposée récemment afin d'améliorer les performances de ce test de dépistage. Cette troisième question rend le test négatif si le patient répond négativement à la question suivante : « Souhaitez-vous de l'aide pour cela ? ». Une étude avait indiqué que l'ajout de la question supplémentaire améliorait la spécificité du test sans réduire sa sensibilité. Objectifs Il s'agissait de décrire la performance de deux tests de dépistage de la dépression majeure, composés, respectivement, de deux et de trois questions, dans une population de patients consultant dans un cabinet de médecine générale pour une plainte physique, et de les valider. Méthode Les réponses aux questions des tests de dépistage de la dépression dans la population de la cohorte SODA (Somatisation, Depression, Anxiety) ont été utilisées. Il s'agissait de patients de plus de 18 ans, sélectionnés aléatoirement, consultant pour au moins une plainte physique auprès de 24 médecins généralistes de Suisse Romande, réexaminés une année après l'inclusion dans la cohorte. Le questionnaire validé « Full Patient Health Questionnaire » a été utilisé, le même jour, pour diagnostiquer une dépression majeure. Ce résultat a été utilisé pour évaluer les performances des deux tests de dépistage en calculant la sensibilité et la spécificité, notamment. Résultats Les données de 724 / 937 patients inclus ont pu être utilisées. Un diagnostic de dépression majeure a été posé chez 9.5% des patients (n = 69). La sensibilité et la spécificité des deux questions de dépistage étaient de 91.3% (IC95% : 81.4-96.4%) et 65.0% (IC95% : 61.2-68.6%), respectivement. En ajoutant la troisième question, la sensibilité des deux questions de dépistage a diminué à 59.4% (IC95% : 47.0-70.9%) et la spécificité a augmenté à 88.2% (IC95% : 85.4-90.5%). Conclusions L'utilisation des deux questions pour le dépistage de la dépression majeure est associée à une haute sensibilité et à une basse spécificité chez des patients se présentant en cabinet de médecine générale pour une plainte physique. En ajoutant la troisième question, la spécificité augmente, mais la sensibilité diminue. Ainsi, en ajoutant la troisième question, quatre patients dépressifs majeurs sur dix ne sont pas détectés, alors que seulement un patient sur dix n'est pas détecté avec les deux questions de dépistage. Notre étude montre que le test composé de deux questions reste une méthode de choix pour le dépistage de la dépression majeure et que l'ajout de la troisième question n'est pas recommandée. Celle-ci reste toutefois pertinente dans l'incitation au dialogue sur le sujet de la dépression entre le médecin et son patient.